• Title/Summary/Keyword: Center Loss

Search Result 3,752, Processing Time 0.043 seconds

A Gap Coupled NRD-Guide Filter Designed with an Equivalent Circuir Model of Evanescent Waveguide (차단주파수 영역 도파관 등가회로 모델을 이용한 Gap-Coupled NRD Guide 대역통과 여파기의 설계)

  • 김소영;이정해
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.6
    • /
    • pp.990-995
    • /
    • 2000
  • As the interest in the millimeter wave frequency (30 ~300 GHz) increases, Nonradiative Dielectric (NRD) guide is being more attractive due to its low loss characteristics. Most of millimeter wave components, which can be realized with waveguide, can also be realized with NRD guide since NRD guide has similar dispersion characteristics and field patterns to waveguide. Previously, Variational Method was applied to the gap discontinuity problem to design a gap-coupled NRD bandpass filter. In this paper, the design procedure was simplified by replacing the air gap region with an equivalent circuit model of an evanescent waveguide using the fact that the NRD guide has a similar structure with a dielectric-filled metal waveguide. Prior to applying this design method to the bandpass filter of millimeter wave frequency range, a bandpass filter of which center frequency is 10 GHz(3-Pole, 0.1 dB ripple, 2% fractional bandwidth) was designed and fabricated. The measured result agrees with one simulated with HFSS within an error range of a fabrication.

  • PDF

Wideband Slot Antenna with Corrugated Structure (물결모양 구조를 갖는 광대역 슬롯 안테나)

  • Kim, Taewon;Yoon, Sungjoon;Lee, Heejae;Choi, Jae-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.1
    • /
    • pp.14-19
    • /
    • 2016
  • In this paper, a wideband slot antenna with corrugated structure antenna is proposed. The proposed antenna consists of a ground plane with corrugated slot and microstrip feed-line. Even with a limited dimension of $70{\times}70{\times}1.6mm$, the proposed antenna has wide bandwidth due to the longer current path formed by the corrugated slot structure. Measured bandwidth(10 dB return loss) and fractional bandwidth of the proposed antenna are 2,180 MHz(2.5~4.68 GHz) and 60.7 % at the center frequency of 3.59 GHz. The proposed antenna has an omni-directional radiation pattern and measured gains and average efficiency were 3.48~5.83 and dBi, 81.55 %, respectively.

A Study on the 4-bit Microwave Phase Shiftter with PIN Diode (PIN 다이오드를 이용한 초고주파 4-비트 위상기에 관한 연구)

  • Cho, Young-Song;Kweon, Heag-Joong;Lee, Young-Chul;Shin, Chull-Chai
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.2
    • /
    • pp.47-54
    • /
    • 1990
  • In this paper, we design the 4-bit phase shifter which have $22.5^{\circ},45^{\circ},90^{\circ}$ and $180^{\circ}$ phase shift by applying the loaded line and switched network phase shifter. Its phase shift is variable with changing of the stub and passive device parameters. The experiments show the 6.5 dB average insertion loss and $10^{\circ}$ average phase error at center frequency, 6GHz. The results of experiment agree well with the theories except $180^{\circ}$ phase shifter.

  • PDF

Cyclic testing of chevron braced steel frames with IPE shear panels

  • Zahrai, Seyed Mehdi
    • Steel and Composite Structures
    • /
    • v.19 no.5
    • /
    • pp.1167-1184
    • /
    • 2015
  • Despite considerable life casualty and financial loss resulting from past earthquakes, many existing steel buildings are still seismically vulnerable as they have no lateral resistance or at least need some sort of retrofitting. Passive control methods with decreasing seismic demand and increasing ductility reduce rate of vulnerability of structures against earthquakes. One of the most effective and practical passive control methods is to use a shear panel system working as a ductile fuse in the structure. The shear Panel System, SPS, is located vertically between apex of two chevron braces and the flange of the floor beam. Seismic energy is highly dissipated through shear yielding of shear panel web while other elements of the structure remain almost elastic. In this paper, lateral behavior and related benefits of this system with narrow-flange link beams is experimentally investigated in chevron braced simple steel frames. For this purpose, five specimens with IPE (narrow-flange I section) shear panels were examined. All of the specimens showed high ductility and dissipated almost all input energy imposed to the structure. For example, maximum SPS shear distortion of 0.128-0.156 rad, overall ductility of 5.3-7.2, response modification factor of 7.1-11.2, and finally maximum equivalent viscous damping ratio of 35.5-40.2% in the last loading cycle corresponding to an average damping ratio of 26.7-30.6% were obtained. It was also shown that the beam, columns and braces remained elastic as expected. Considering this fact, by just changing the probably damaged shear panel pieces after earthquake, the structure can still be continuously used as another benefit of this proposed retrofitting system without the need to change the floor beam.

Chemorheological Behavior of Cyanate Ester Resin and Properties of Carbon Fiber Reinforced Polymer Composites (시아네이트 에스터 수지의 화학유변학적 거동 및 탄소섬유강화 고분자 복합재료의 물성)

  • Na, Hyo Yeol;Yoon, Byung Chul;Kim, Seung Hwan;Lee, Seong Jae
    • Elastomers and Composites
    • /
    • v.48 no.2
    • /
    • pp.133-140
    • /
    • 2013
  • Carbon fiber reinforced polymer (CFRP) composites consist of carbon fibers in a polymer matrix. Recently, CFRP composites having high thermal stability and low outgassing are finding their use in high performance materials for aerospace and electronics applications under high temperature and high vacuum conditions. Cyanate ester resin is one of the most suitable matrix resins for this purpose. In this study, proper combination of cyanate ester and catalyst, curing behavior, and cure cycle were determined by chemorheology. Optimum condition was found to be catalyst content of 100 ppm and curing temperature of $150^{\circ}C$. Thermal stability and outgassing of cured resin composition were analyzed and the results showed thermal decomposition temperature of $385^{\circ}C$ and total mass loss of 0.29%. The CFRP prepregs and subsequent composites were fabricated by predetermined resin composition and the cure condition. Tensile moduli of the composites were compared with theoretical models and the results were very consistent.

Synthesis of Gd2O3 : (Li, Eu) Films using Phosphor Powders Coated with SiO2 Nano Particles (SiO2 나노 입자로 코팅된 형광체 분말을 이용한 Gd2O3 : (Li, Eu) 필름 제조)

  • Park, Jung-Chul
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.6
    • /
    • pp.619-624
    • /
    • 2003
  • The $Gd_{1.9-x}Li_{0.1}Eu_xO_3$ (x=0.02, 0.05, 0.08, and 0.12) powders (${\thickapprox}1{\mu}m$) synthesized by sol-gel method, whose surfaces are modified in a colloidal silica suspension (size of $SiO_2$ particles: ${\sim}30$ nm), have been fabricated to highly stable and effective luminescent films on the glass substrates. Thanks to the fused $SiO_2$ nano particles in the vicinity of the glass softening temperature (at around $700^{\circ}C$), $Gd_{1.9-x}Li_{0.1}Eu_xO_3$ powders are strongly attached onto the surface of glass substrate (>9H, pencil hardness tester). This simple and low-cost method to get $Gd_{1.9-x}Li_{0.1}Eu_xO_3$ phosphor films without any loss of luminescence brightness would promise for applications to display devices.

Clinical Outcomes and Complications after Pedicle Subtraction Osteotomy for Fixed Sagittal Imbalance Patients : A Long-Term Follow-Up Data

  • Hyun, Seung-Jae;Rhim, Seung-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.2
    • /
    • pp.95-101
    • /
    • 2010
  • Objective : Clinical, radiographic, and outcomes assessments, focusing on complications, were performed in patients who underwent pedicle subtraction osteotomy (PSO) to assess correction effectiveness, fusion stability, procedural safety, neurological outcomes, complication rates, and overall patient outcomes. Methods : We analyzed data obtained from 13 consecutive PSO-treated patients presenting with fixed sagittal imbalances from 1999 to 2006. A single spine surgeon performed all operations. The median follow-up period was 73 months (range 41-114 months). Events during peri operative course and complications were closely monitored and carefully reviewed. Radiographs were obtained and measurements were done before surgery, immediately after surgery, and at the most recent follow-up examinations. Clinical outcomes were assessed using the Oswestry Disability Index and subjective satisfaction evaluation. Results : Following surgery, lumbar lordosis increased from $-14.1^{\circ}{\pm}20.5^{\circ}$ to $-46.3^{\circ}{\pm}12.8^{\circ}$ (p<0.0001). and the C7 plumb line improved from $115{\pm}43\;mm$ to $32{\pm}38\;mm$ (p<0.0001). There were 16 surgery-related complications in 8 patients; 3 intraoperative, 3 perioperative, and 10 late-onset postoperative. The prevalence of proximal junctional kyphosis (PJK) was 23% (3 of 13 patients). However, clinical outcomes were not adversely affected by PJK. Intraoperative blood loss averaged 2,984 mL. The C7 plumb line values and postoperative complications were closely correlated with clinical results. Conclusion : Intraoperative or postoperative complications are relatively common following PSO. Most late-onset complications in PSO patients were related to PJK and instrumentation failure. Correcting the C7 plumb line value with minimal operative complications seemed to lead to better clinical results.

Tailoring the properties of spray deposited V2O5 thin films using swift heavy ion beam irradiation

  • Rathika, R.;Kovendhan, M.;Joseph, D. Paul;Pachaiappan, Rekha;Kumar, A. Sendil;Vijayarangamuthu, K.;Venkateswaran, C.;Asokan, K.;Jeyakumar, S. Johnson
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2585-2593
    • /
    • 2020
  • Swift heavy ion (SHI) beam irradiation can generate desirable defects in materials by transferring sufficient energy to the lattice that favours huge possibilities in tailoring of materials. The effect of Ag15+ ion irradiation with energy 200 MeV on spray deposited V2O5 thin films of thickness 253 nm is studied at various ion doses from 5 × 1011 to 1 × 1013 ions/㎠. The XRD results of pristine film confirmed orthorhombic structure of V2O5 and its average crystallite size was found to be 20 nm. The peak at 394 cm-1 in Raman spectra confirmed O-V-O bonding of V2O5, whereas 917 cm-1 arise because of distortion in stoichiometry by a loss of oxygen atoms. Raman peaks vanished completely above the ion fluence of 5 × 1012 ions/㎠. Optical studies by UV-Vis spectroscopy shows decrement in transmittance with an increase in ion fluence up to 5 × 1012 ions/㎠. The red shift is observed both in the direct and indirect band gaps until 5 × 1012 ions/㎠. The surface topography of the pristine film revealed sheath like structure with randomly distributed spherical nano-particles. The roughness of film decreased and the density of spherical nanoparticles increased upon irradiation. Irradiation improved the conductivity significantly for fluence 5 × 1011 ions/㎠ due to band gap reduction and grain growth.

Development of the Large-area Au/Pd Transfer-printing Process Applying Both the Anti-Adhesion and Adhesion Layers (접착방지막과 접착막을 동시에 적용한 대면적 Au/Pd 트랜스퍼 프린팅 공정 개발)

  • Cha, Nam-Goo
    • Korean Journal of Materials Research
    • /
    • v.19 no.8
    • /
    • pp.437-442
    • /
    • 2009
  • This paper describes an improved strategy for controlling the adhesion force using both the antiadhesion and adhesion layers for a successful large-area transfer process. An MPTMS (3-mercaptopropyltrimethoxysilane) monolayer as an adhesion layer for Au/Pd thin films was deposited on Si substrates by vapor self assembly monolayer (VSAM) method. Contact angle, surface energy, film thickness, friction force, and roughness were considered for finding the optimized conditions. The sputtered Au/Pd ($\sim$17 nm) layer on the PDMS stamp without the anti-adhesion layer showed poor transfer results due to the high adhesion between sputtered Au/Pd and PDMS. In order to reduce the adhesion between Au/Pd and PDMS, an anti-adhesion monolayer was coated on the PDMS stamp using FOTS (perfluorooctyltrichlorosilane) after $O_2$ plasma treatment. The transfer process with the anti-adhesion layer gave good transfer results over a large area (20 mm $\times$ 20 mm) without pattern loss or distortion. To investigate the applied pressure effect, the PDMS stamp was sandwiched after 90$^{\circ}$ rotation on the MPTMS-coated patterned Si substrate with 1-${\mu}m$ depth. The sputtered Au/Pd was transferred onto the contact area, making square metal patterns on the top of the patterned Si structures. Applying low pressure helped to remove voids and to make conformal contact; however, high pressure yielded irregular transfer results due to PDMS stamp deformation. One of key parameters to success of this transfer process is the controllability of the adhesion force between the stamp and the target substrate. This technique offers high reliability during the transfer process, which suggests a potential building method for future functional structures.

Numerical Study for the Improvement of Tapered-hole Clinching Joint Strength of Fiber Metal Laminates and Aluminum 5052 using the Taguchi Method (다구찌 기법을 이용한 섬유금속적층판과 Al 5052 합금의 경사 홀 클린칭 접합력 향상을 위한 수치적 연구)

  • Kang, D.S.;Lee, B.E.;Park, E.T.;Kim, J.;Kang, B.S.;Song, W.J.
    • Transactions of Materials Processing
    • /
    • v.24 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • The purpose of the current study is to improve the clinching joint strength of aluminum and fiber metal laminates (FMLs) comprised of three layers. The joining of FML and Al 5052 by a conventional clinching joint has some disadvantages such as necking of the upper sheet, lack of interlocking, defects caused by the vertical load, and especially loss of strength of the composite material due to the low ductility. In the current study, a tapered-hole clinching method is proposed as an alternative for the joining of Al 5052 and FMLs. A hole with a tapered shape is formed before the joining process. The design parameters were evaluated using the Taguchi method for the geometry of the tapered hole in order to determine the maximum separation load. The diameter of the punch corner, clearance, punch stroke and the tapered length were used as the main variables in the Taguchi method. In conclusion, the contribution ratio for each of the fours variable examined was 35.07%, 22.44%, 21.32% and 14.11%, respectively. In addition, the appropriate combination of the design parameters can make a 5% improvement in the vertical direction joint strength.