• Title/Summary/Keyword: Center Loss

Search Result 3,752, Processing Time 0.038 seconds

Loss Analysis and Validation of Laminated Core Joints

  • Du, Yong;Zhang, Xian;Zhang, Junjie;Liu, Lanrong;Jiao, Cuiping;Cheng, Zhiguang
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2008.12a
    • /
    • pp.178-178
    • /
    • 2008
  • This paper presents an efficient approach for simulating the loss of the laminated core joints in power transformers. Two laminated core models, with the same material and joint type but different leg length, are established for validating the specific total loss inside the joint region.

  • PDF

Application of Remotely Sensed Data and Geographic Information System in Watershed Management Planning in Imha, Korea

  • CHAE Hyo-Sok;LEE Geun-Sang;KIM Tae-Joon;KOH Deuk-Koo
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.361-364
    • /
    • 2005
  • The use of remotely sensed data and geographic information system (GIS) to develop conservation-oriented watershed management strategies on Imha Dam, Korea, is presented. The change of land use for study area was analyzed using multi-temporal Landsat imagery. A soil loss model was executed within a GIS environment to evaluate watershed management strategies in terms of soil loss. In general, remotely sensed data provide efficient means of generating the input data required for the soil loss model. Also, GIS allowed for easy assessment of the relative erosion hazard over the watershed under the different land use change options. The soil loss model predicted substantial declines in soil loss under conservation-oriented land management compared to current land management for Imha Dam. The results of this study indicate that soil loss potential (5,782,829 ton/yr) on Imha Dam in 2003 is approximately 1.27 times higher than that (4,557,151 ton/yr) in 1989. This study represents the first attempt in the application of GIS technology to watershed conservation planning for Imha Dam. The procedures developed will contribute to the evolution of a decision support system to guide the land planning and dam management in Imha Dam.

  • PDF

Analysis of Frequency Response Depending on Wire-bonding Length Variation (Wire-bonding의 길이 변화에 따른 주파수별 특성 분석)

  • Gwon, Eun-Jin;Mun, Jong-Won;Ryu, Jong-In;Park, Se-Hoon;Kim, Jun-Chul
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.551-552
    • /
    • 2008
  • This paper presets a results of frequency response in variation of wire bonding length. A gold ball bonding is used as a wire bonding process, and a DPDT(double pole double thru) switch is adapted as a device for test. Wire length is ranged from 442um to 833um and a measured frequency range is from 1 GHz to 6 GHz. Little difference are measured in insertion loss and return loss depending on wire length. Measured S21 and S11 are -0.58 dB and -17.7 dB, respectively. S21 insertion loss is rising up and S11 insertion loss is falling down as the frequency is increased.

  • PDF

Improved Magnetic Properties of Silicon-Iron Alloy Powder Core

  • Lee, Tae-Kyung;Kim, Gu-Hyun;Choi, Gwang-Bo;Jeong, In-Bum;Kim, Kwang-Youn;Jang, Pyung-Woo
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1191-1192
    • /
    • 2006
  • Eventhough Fe-6.5 wt.% Si alloy shows excellent magnetic properties, magnetic components made of the alloy are not totally because of its extremely low ductility. In order to overcome this demerit of alloy, 6.7 wt.% Si alloy powders were produced by gas atomization and then post-processed to form magnetic cores. By doing so, the total core loss could be minimized by reducing both hysteresis and eddy current loss. From our experiments, we were able to achive a core loss of $390mW/cm^3$ at 0.1 T and 50 kHz through proper processes and a permeability $\mu_{eff}$ of 68 at low frequency.

  • PDF

Introduction to the standard reference data of electron energy loss spectra and their database: eel.geri.re.kr

  • Jeong Eun Chae;Ji-Soo Kim;Sang-Yeol Nam;Min Su Kim;Jucheol Park
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.2.1-2.7
    • /
    • 2020
  • Electron energy loss spectroscopy (EELS) is an analytical technique that can provide the structural, physical and chemical information of materials. The EELS spectra can be obtained by combining with TEM at sub-nanometer spatial resolution. However, EELS spectral information can't be obtained easily because in order to interpret EELS spectra, we need to refer to and/or compare many reference data with each other. And in addition to that, we should consider the different experimental variables used to produce each data. Therefore, reliable and easily interpretable EELS standard reference data are needed. Our Electron Energy Loss Data Center (EELDC) has been designated as National Standard Electron Energy Loss Data Center No. 34 to develop EELS standard reference (SR) data and to play a role in dissemination and diffusion of the SR data to users. EELDC has developed and collected EEL SR data for the materials required by major industries and has a total of 82 EEL SR data. Also, we have created an online platform that provides a one-stop-place to help users interpret quickly EELS spectra and get various spectral information. In this paper, we introduce EEL SR data, the homepage of EELDC and how to use them.

Gamitaeeumjowee-tang for Weight Loss in Post-Menopausal Obese Women: A Retrospective Chart Review (폐경 후 비만 여성의 체중감량을 위한 가미태음조위탕의 임상적 활용: 후향적 차트 리뷰)

  • Yun-Jin Lee;Jeong-In Kang;Yun-Ha Kim;Eun-Chae Min;Young-Woo Lim;Eunjoo Kim
    • The Journal of Korean Medicine
    • /
    • v.45 no.1
    • /
    • pp.65-79
    • /
    • 2024
  • Objectives: The purpose of this study is to evaluate weight change and analyze adverse events in post-menopausal obese women with Gamitaeeumjowee-tang for weight loss. Methods: A retrospective chart review was conducted for medical records of 115 post-menopausal obese women (body mass index, BMI≥25 kg/m2) who were administered with Gamitaeeumjowee-tang for 12 weeks for the purpose of weight loss. Weight, skeletal muscle ratio and BMI changes were compared before and after the program. Adverse events were evaluated by causality, severity and system-organ classes. Results: A total of 115 patients were included in this study. The average total weight loss in post-menopausal women was 5.72±2.04kg(p<0.001) and the average weight loss rate was 8.06±2.70%(p<0.001). After the 12-week program, the body fat rate was significantly decreased(3.76±2.20%)(p<0.001) and the skeletal muscle ratio was significantly increased(2.07±1.24%)(p<0.001). There were no significant differences in weight loss, skeletal muscle ratio change and body fat rate change depending on the number of hospital visits. Insomnia was frequently reported throughout the period, and no serious adverse events were reported. Conclusions: This study showed the potential that weight management treatment with Gamitaeeumjowee-tang could be a good way to lose weight of post-menopausal obese women without serious adverse events. Continuous well designed clinical studies are needed.

Gamitaeeumjowee-tang for Weight Loss in Post-Menopausal Obese Women: A Retrospective Chart Review (폐경 후 비만 여성의 체중감량을 위한 가미태음조위탕의 임상적 활용: 후향적 차트 리뷰)

  • Yun-Jin Lee;Jeong-In Kang;Yun-Ha Kim;Eun-Chae Min;Young-Woo Lim;Eunjoo Kim
    • The Journal of Korean Medicine
    • /
    • v.45 no.2
    • /
    • pp.169-173
    • /
    • 2024
  • Objectives: The purpose of this study is to evaluate weight change and analyze adverse events in post-menopausal obese women with Gamitaeeumjowee-tang for weight loss. Methods: A retrospective chart review was conducted for medical records of 115 post-menopausal obese women (body mass index, BMI≥25 kg/m2) who were administered with Gamitaeeumjowee-tang for 12 weeks for the purpose of weight loss. Weight, skeletal muscle ratio and BMI changes were compared before and after the program. Adverse events were evaluated by causality, severity and system-organ classes. Results: A total of 115 patients were included in this study. The average total weight loss in post-menopausal women was 5.72±2.04kg(p<0.001) and the average weight loss rate was 8.06±2.70%(p<0.001). After the 12-week program, the body fat rate was significantly decreased(3.76±2.20%)(p<0.001) and the skeletal muscle ratio was significantly increased(2.07±1.24%)(p<0.001). There were no significant differences in weight loss, skeletal muscle ratio change and body fat rate change depending on the number of hospital visits. Insomnia was frequently reported throughout the period, and no serious adverse events were reported. Conclusions: This study showed the potential that weight management treatment with Gamitaeeumjowee-tang could be a good way to lose weight of post-menopausal obese women without serious adverse events. Continuous well designed clinical studies are needed.

Study on vibration energy characteristics of vehicle-track-viaduct coupling system considering partial contact loss beneath track slab

  • Liu, Linya;Zuo, Zhiyuan;Zhou, Qinyue;Qin, Jialiang;Liu, Quanmin
    • Structural Engineering and Mechanics
    • /
    • v.75 no.4
    • /
    • pp.497-506
    • /
    • 2020
  • CA mortar layer disengagement will give rise to the overall structural changes of the track and variation in the vibration form of the ballastless track. By establishing a vehicle-track-viaduct coupling analysis and calculation model, it is possible to analyze the CRTS-I type track structure vibration response while the track slab is disengaging with the power flow evaluation method, to compare the two disengaging types, namely partial contact loss at one edge beneath track slab and partial contact loss at midpoint beneath track slab. It can also study how the length of disengaging influences the track structures vibration power. It is showed that when the partial contact loss beneath track slab, and the relative vibration energy level between the rail and the track slab increases significantly within [10, 200]Hz with the same disengaging length, the partial contact loss at one edge beneath track slab has more prominent influence on the vibration power than the partial contact loss at midpoint beneath track slab. With the increase of disengaging length, the relative vibration energy level of the track slab grows sharply, but it will change significantly when it reaches 1.56 m. Little effect will be caused by the relative vibration energy level of the viaduct. The partial contact loss beneath the track slab will cause more power distribution and transmission between the trail and track slab, and will then affect the service life of the rail and track slab.

A Study on the Dynamic Loss Coefficients of Non-standard Fittings in Ship Exhaust Gas Pipes

  • Park, Seongjong;Park, Yonghwan;Kim, Bongjae;Choi, Jaewoong
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.479-485
    • /
    • 2019
  • As exhaust gas systems of ships become more complicated, it is necessary to calculate an accurate pressure loss at their design stage. If the dynamic loss coefficients of non-standard fittings mainly used in exhaust gas pipe (EGP) are well-documented, it would be possible to calculate precise pressure loss more readily than using the conventional method that analyzes the entire system. In the case of a ship's EGP, the flow rates and temperatures of exhaust gas are determined by engine specifications, and the range of the flow rate and temperature is limited according to operating conditions. In addition, as it is possible to define non-standard fittings frequently used in an EGP, a database can be easily constructed and effective. This paper illustrates effective parameters and analysis cases of several types of non-standard fittings mounted in ship EGPs. The analysis procedure proposed in this paper is verified using existing research results on HVAC fittings. The numerical procedure, which is minimally affected by manpower and grid, is established such that it can be applied at the industry level.

Experimental and Numerical Analysis of a Simple Core Loss Calculation for AC Filter Inductor in PWM DC-AC Inverters

  • Lee, Kyoung-Jun;Cha, Honnyong;Lee, Jong-Pil;Yoo, Dong-Wook;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.113-121
    • /
    • 2013
  • This paper introduces a simple core loss calculation method for output filter inductor in pulse width modulation (PWM) DC-AC inverter. Amorphous C-core (AMCC-320) is used to analyze the core loss. In order to measure core loss of the output filter inductor and validate the proposed method, a single-phase half-bridge inverter and a calorimeter are used. By changing switching frequency and modulation index (MI) of the inverter, core loss of the AMCC-320 is measured with the lab-made calorimeter and the results are compared with calculated core loss. The proposed method can be easily extended to other core loss calculation of various converters.