• Title/Summary/Keyword: Center Loss

Search Result 3,752, Processing Time 0.038 seconds

Tunneling Effect on Sound Transmission Loss Measurement (차음성능 계측시 터널링 효과에 관한 해석적 연구)

  • 김봉기;김재승;김현실;강현주;김상렬
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1228-1233
    • /
    • 2002
  • This study is aimed to evaluate a tunneling effect in association with the measurement of sound transmission loss. Based on the formulation for sound transmission loss of a finite panel in the presence of tunnel, variations of the sound transmission loss with parameters such as the location of panel and tunnel depth are investigated. It can be seen that differences in the sound transmission loss are quite evident below coincidence frequency and the sound transmission loss greatly depends on panel location in the tunnel. In comparison with the case without a tunnel, maximum difference occurs in the case where the panel is placed on the center of the tunnel and the flushing with the end of the tunnel gives the better estimation of transmission loss.

  • PDF

Improved Design to reduce Eddy Current Loss in Retain Ring in Superconducting Machines

  • Lee, Sang-Ho;Jung, Jae-Woo;Sun, Tao;Hong, Jung-Pyo;Kim, Yeong-Chun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.2
    • /
    • pp.13-16
    • /
    • 2011
  • This paper describes the reduction method of eddy current loss generated into a retaining ring installed in wound-field superconducting machine. In order to suggest the reduction method of eddy current loss of the retaining ring, this paper is divided into three parts. Firstly, eddy current loss of prototype model is calculated. Secondly, eddy current loss versus material and shape of the retaining ring is compared. Finally, the material and the shape of the retaining ring to reduce coupling loss generated by a time-varying magnetic field are proposed. In this paper, eddy current loss is calculated by 3-dimensional transient analysis.

Measurement of Stator Core Loss of an Induction Motor at Each Manufacturing Process

  • Jeong, Kwangyoung;Ren, Ziyan;Yoon, Heesung;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1309-1314
    • /
    • 2014
  • The measurement of stator core loss for an induction motor at each manufacturing process is carried out in this paper. Iron loss in the stator core of induction motor changes after each manufacturing process due to the mechanical stress, which can cause the deterioration of the magnetic performances. This paper proposes a new iron loss measuring system of the stator core in an induction motor, which can be applied to the case when the distribution of magnetic flux density is not uniform along the magnetic flux path. In the system, the iron loss is calculated based on the induced voltage of the B-search coil and exciting current.

The Fabrication and Characterization of Embedded Switch Chip in Board for WiFi Application (WiFi용 스위치 칩 내장형 기판 기술에 관한 연구)

  • Park, Se-Hoon;Ryu, Jong-In;Kim, Jun-Chul;Youn, Je-Hyun;Kang, Nam-Kee;Park, Jong-Chul
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.3
    • /
    • pp.53-58
    • /
    • 2008
  • In this study, we fabricated embedded IC (Double Pole Double throw switch chip) polymer substrate and evaluate it for 2.4 GHz WiFi application. The switch chips were laminated using FR4 and ABF(Ajinomoto build up film) as dielectric layer. The embedded DPDT chip substrate were interconnected by laser via and Cu pattern plating process. DSC(Differenntial Scanning Calorimetry) analysis and SEM image was employed to calculate the amount of curing and examine surface roughness for optimization of chip embedding process. ABF showed maximum peel strength with Cu layer when the procuring was $80\sim90%$ completed and DPDT chip was laminated in a polymer substrate without void. An embedded chip substrate and wire-bonded chip on substrate were designed and fabricated. The characteristics of two modules were measured by s-parameters (S11; return loss and S21; insertion loss). Insertion loss is less than 0.55 dB in two presented embedded chip board and wire-bonded chip board. Return loss of an embedded chip board is better than 25 dB up to 6 GHz frequency range, whereas return loss of wire-bonding chip board is worse than 20 dB above 2.4 GHz frequency.

  • PDF

THREE-DIMENSIONAL SPACE CHANGES AFTER PREMATURE LOSS OF THE PRIMARY FIRST MOLAR: A LONGITUDINAL STUDY (제1유구치의 조기 상실로 인한 공간 변화에 대한 3차원적 분석)

  • Kim, Ji-Yeon;Jung, Da-Woon;Kwak, So-Youn;Yoo, Seung-Eun;Park, Ki-Tae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.297-304
    • /
    • 2008
  • The purpose of this study was to evaluate a 3-Dimensional laser scanner for the space analysis after loss of a primary first molar. Six children with premature loss of a primary first molar were examined using study models taken before and after the extraction. The results were as follows: 1. There was no change in primary molar space after the extraction of a maxillary primary first molar However, 2 out of 3 children experienced primary molar space loss in extraction side of a mandibular primary first molar. 2. Arch width and arch perimeter showed no difference between initial and final model. 3. All primary canines did not show any changes in inclination. Maxillary primary second molars had similar changes in both extraction and control side. However, 2 out of 3 mandibular primary second molars in extraction side showed more lingual tipping compared to control side. Mandibular permanent first molars tipped more lingually in extraction side. 4. In angulation, primary canines showed nothing of significance. Mandibular primary second molars tipped more mesially in extraction side than in control side. Maxillary permanent first molars have increased distal angulation after extraction of primary first molars in both side.

  • PDF

Low Conversion Loss and High Isolation 94 GHz MHEMT Mixer Using Micro-machined Ring Coupler (마이크로 머시닝 링 커플러를 사용한 낮은 변환 손실 및 높은 격리 특성의 94 GHz MHEMT 믹서)

  • An Dan;Kim Sung-Chan;Park Jung-Dong;Lee Mun-Kyo;Lee Bok-Hyung;Park Hyun-Chang;Shin Dong-Hoong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.6 s.348
    • /
    • pp.46-52
    • /
    • 2006
  • We report on a high performance 94 GHz MMIC resistive mixer using 70-nm metamorphic high electron mobility transistor (MHEMT) and micro-machined W-band ring coupler. A novel 3-dimensional structure of resistive mixer was proposed in this work, and the ring coupler with the surface micro-machined dielectric-supported air-gap microstrip line (DAMLs) structure was used for high LO-RF isolation. The fabricated mixer showed an excellent LO-RF isolation of -29.3 dB and a low conversion loss of 8.9 dB at 94 GHz. To our knowledge, compared to previously reported W-band mixers, the proposed MHEMT-based resistive mixer using micro-machined ring coupler has shown superior LO-RF isolation as well as similar conversion loss.

Diagnostic Significance of Brainstem Auditory Evoked Potentials in Microvascular Decompression of Patients with Hemifacial Spasm or Trigeminal Neuralgia

  • Park, Sang-Koo;Lim, Sung-Hyuk;Park, Chan-Woo;Park, Jin-Woo;Chang, Sung-Ho;Park, Keun-Hye;Park, Hae-Ja;Song, Ji-Hye;Uhm, Dong-Ok;Kim, Ki-Bong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.43 no.1
    • /
    • pp.19-25
    • /
    • 2011
  • The purpose of this study was to analyse brainstem auditory evoked potentials (BAEP) wave change data during microvascular decompression (MVD). The nerve function of Cranial Nerve VIII is at risk during MVD. Intraoperative monitoring of BAEP can be a useful tool to decrease the danger of hearing loss. Between January and December 2009, 242 patients had MVD for hemifacial spasm (HFS) and trigeminal neuralgia (TN). Among intraoperative BAEP changes, amplitude of V-V' was the most frequently observed during cerebellar retraction and decompression step of the MVD procedure. 138 patients (57%) had no BAEP change while 104 patients (42.98%) had BAEP change. 69 patients (28.5%) had Type A-I, 16 patients (6.6%) had Type A-II, 5 patients (2.1%) had Type B, and 13 patients (5.37%) had Type C. MVD is a surgical procedure to relieve the symptoms (e.g. pain, muscle twitching) caused by compression of a nerve by an artery or vein. During BAEP intraoperative monitoring, the surgical step is important in interpreting the changes of wave V. Several potential mechanisms of injury may affect the cochlear nerve, and complete loss of BAEP is often associated with postoperative hearing loss. Intraoperative BAEP monitoring may provide an early warning of hearing disturbance after MVD.

  • PDF

Secondary Phase and Defects in Cu2ZnSnSe4 Solar Cells with Decreasing Absorber Layer Thickness

  • Kim, Young-Ill;Son, Dae-Ho;Lee, Jaebaek;Sung, Shi-Joon;Kang, Jin-Kyu;Kim, Dae-Hwan;Yang, Kee-Jeong
    • Current Photovoltaic Research
    • /
    • v.9 no.3
    • /
    • pp.84-95
    • /
    • 2021
  • The power conversion efficiency of Cu2ZnSnSe4 (CZTSe) solar cells depends on the absorber layer thickness; however, changes in the characteristics of the cells with varying absorber layer thickness are unclear. In this study, we investigated the changes in the characteristics of CZTSe solar cells for varying absorber layer thickness. Five absorber thicknesses were employed: CZTSe1 2.78 ㎛, CZTSe2 1.01 ㎛, CZTSe3 0.55 ㎛, CZTSe4 0.29 ㎛, and CZTSe5 0.15-0.23 ㎛. The efficiency of the CZTSe solar cells decreased as the absorber thickness decreased, resulting in power conversion efficiencies of 10.45% (CZTSe1), 8.67% (CZTSe2), 7.14% (CZTSe3), 3.44% (CZTSe4), and 1.54% (CZTSe5). As the thickness of the CZTSe absorber layer decreased, the electron-hole recombination at the grain boundaries and the absorber-back-contact interface increased. This caused an increase in the current loss, owing to light loss in the long-wavelength region. In addition, as the thickness of the CZTSe absorber layer decreased, more ZnSe was produced, and the resulting defects and defect clusters led to an open-circuit voltage loss.

Effect of Temperature Abuse on Quality and Metabolites of Frozen/Thawed Beef Loins

  • Kwon, Jeong A;Yim, Dong-Gyun;Kim, Hyun-Jun;Ismail, Azfar;Kim, Sung-Su;Lee, Hag Ju;Jo, Cheorun
    • Food Science of Animal Resources
    • /
    • v.42 no.2
    • /
    • pp.341-349
    • /
    • 2022
  • The objective of this study was to examine the effect of temperature abuse prior to cold storage on changes in quality and metabolites of frozen/thawed beef loin. The aerobic packaged samples were assigned to three groups: refrigeration (4℃) (CR); freezing (-18℃ for 6 d) and thawing (20±1℃ for 1 d), followed by refrigeration (4℃) (FT); temperature abuse (20℃ for 6 h) prior to freezing (-18℃ for 6 d) and thawing (20±1℃ for 1 d), followed by refrigeration (4℃) (AFT). FT and AFT resulted in higher volatile basic nitrogen (VBN) values than CR (p<0.05), and these values rapidly increased in the final 15 d. Cooking loss decreased significantly with an increase in the storage period (p<0.05). In addition, cooking loss was lower in the FT and AFT groups than in the CR owing to water loss after storage (p<0.05). A scanning electron microscope (SEM) revealed that frozen/thawed beef samples were influenced by temperature abuse in the structure of the fiber at 15 d. Metabolomic analysis showed differences among CR, FT, and AFT from partial least square discriminant analysis (PLS-DA) based on proton nuclear magnetic resonance (1H NMR) profiling. The treatments differed slightly, with higher FT than AFT values in several metabolites (phenylalanine, isoleucine, valine, betaine, and tyrosine). Overall, temperature abuse prior to freezing and during thawing of beef loin resulted in accelerated quality changes.

Sketch-based 3D object retrieval using Wasserstein Center Loss (Wasserstein Center 손실을 이용한 스케치 기반 3차원 물체 검색)

  • Ji, Myunggeun;Chun, Junchul;Kim, Namgi
    • Journal of Internet Computing and Services
    • /
    • v.19 no.6
    • /
    • pp.91-99
    • /
    • 2018
  • Sketch-based 3D object retrieval is a convenient way to search for various 3D data using human-drawn sketches as query. In this paper, we propose a new method of using Sketch CNN, Wasserstein CNN and Wasserstein center loss for sketch-based 3D object search. Specifically, Wasserstein center loss is a method of learning the center of each object category and reducing the Wasserstein distance between center and features of the same category. To do this, the proposed 3D object retrieval is performed as follows. Firstly, Wasserstein CNN extracts 2D images taken from various directions of 3D object using CNN, and extracts features of 3D data by computing the Wasserstein barycenters of features of each image. Secondly, the features of the sketch are extracted using a separate Sketch CNN. Finally, we learn the features of the extracted 3D object and the features of the sketch using the proposed Wasserstein center loss. In order to demonstrate the superiority of the proposed method, we evaluated two sets of benchmark data sets, SHREC 13 and SHREC 14, and the proposed method shows better performance in all conventional metrics compared to the state of the art methods.