• Title/Summary/Keyword: Center Loss

Search Result 3,752, Processing Time 0.065 seconds

Full mouth rehabilitation accompanied by phonetic analysis of a patient with reduction of vertical dimension of occlusion, and inaccurate pronunciation due to numerous tooth loss: a case report (다수의 치아 상실로 인해 교합수직고경의 감소와 부정확한 발음을 가진 환자의 발음평가를 동반한 전악 수복 증례)

  • Ji-Young Park;Jong-Jin Kim;Jin Baik;Hyun-Suk Cha;Joo-Hee Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.119-132
    • /
    • 2023
  • The loss of posterior occlusal support due to tooth loss is likely to lead to compensatory protrusion and labial tilt of the anterior teeth, which may be accompanied by a deep bite and a decrease in vertical dimension. The patient may suffer from a decrease in masticatory efficiency, inaccurate pronunciation, facial appearance changes, and temporomandibular joint disorder, so stable occlusal formation with support of posterior occlusion and restoration of vertical dimension is necessary. We report the case of a patient with reduction of vertical dimension, and inaccurate pronunciation due to multiple tooth loss who underwent full mouth rehabilitation with increased vertical dimension accompanied by phonetic analysis and achieved satisfactory functional and aesthetic results.

Dexamethasone-induced muscle atrophy and bone loss in six genetically diverse collaborative cross founder strains demonstrates phenotypic variability by Rg3 treatment

  • Bao Ngoc Nguyen;Soyeon Hong;Sowoon Choi;Choong-Gu Lee;GyHye Yoo;Myungsuk Kim
    • Journal of Ginseng Research
    • /
    • v.48 no.3
    • /
    • pp.310-322
    • /
    • 2024
  • Background: Osteosarcopenia is a common condition characterized by the loss of both bone and muscle mass, which can lead to an increased risk of fractures and disability in older adults. The study aimed to elucidate the response of various mouse strains to treatment with Rg3, one of the leading ginsenosides, on musculoskeletal traits and immune function, and their correlation. Methods: Six Collaborative Cross (CC) founder strains induced muscle atrophy and bone loss with dexamethasone (15 mg/kg) treatment for 1 month, and half of the mice for each strain were orally administered Rg3 (20 mg/kg). Different responses were observed depending on genetic background and Rg3 treatment. Results: Rg3 significantly increased grip strength, running performance, and expression of muscle and bone health-related genes in a two-way analysis of variance considering the genetic backgrounds and Rg3 treatment. Significant improvements in grip strength, running performance, bone area, and muscle mass, and the increased gene expression were observed in specific strains of PWK/PhJ. For traits related to muscle, bone, and immune functions, significant correlations between traits were confirmed following Rg3 administration compared with control mice. The phenotyping analysis was compiled into a public web resource called Rg3-OsteoSarco. Conclusion: This highlights the complex interplay between genetic determinants, pathogenesis of muscle atrophy and bone loss, and phytochemical bioactivity and the need to move away from single inbred mouse models to improve their translatability to genetically diverse humans. Rg3-OsteoSarco highlights the use of CC founder strains as a valuable tool in the field of personalized nutrition.

A gas display device with electron emitter

  • Son, Seung-Hyun;Nam, Mun-Ho;Kim, Jung-Min;Cho, Sung-Hee;Jang, Sang-Hun;Kim, Gi-Young;Han, In-Su;Kim, Dae-Hyun;Cho, Young-Mi;Kim, Chang-Wook;Park, Hyoung-Bin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1253-1256
    • /
    • 2007
  • A display device combining plasma display panel (PDP) and field emission display (FED) is proposed to achieve high luminous efficiency. The device can avoid the main energy loss channels of both PDP (ion loss) and FED (low CL efficiency). $2{\sim}6$”-diagonal test panels with carbon nano-tube (CNT) electron emitter and Xenon ambient gas showed the luminous efficiency of 4.14lm/W and brightness of $263cd/m^2$ at 35V (1kHz, 1% duty), indicating that it is a good candidate for the low voltage driven, highly efficient next generation display.

  • PDF

A study on Permanent Magnet Synchronous Servo Motor Control (영구자석 동기 서보 전동기의 제어에 관한 연구)

  • Kim, J.K.;Choi, U.D.;Jung, M.K.;Lee, H.S.;Kim, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.543-547
    • /
    • 1991
  • This paper illustrates maximum torque per ampare radio operation and efficiency operation, which are prevalently applied to the control of permanent magnet synchronous motor(PMSM). Maximum torque per ampare ratio operation minimizes the copper loss of PMSM and maximum efficiency operation minimizes the total loss of PMSM. To verify the difference of these method, simulation and experiment results applied to IPMSM(Interior type PMSM) and SPMSM(Surface mounted PMSM) are presented.

  • PDF

Development of Characteristics Analysis Program (FEMCAD) for IPMSMs (매입형 영구자석 동기전동기 (IPMSMs) 특성해석 프로그램 (FEMCAD) 개발)

  • Kim, Young-Kyoun;Rhyu, Se-Hyun;Jung, In-Soung;Hur, Jin;Sung, Ha-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1035-1036
    • /
    • 2007
  • This paper presents the characteristics analysis of Interior Permanent Magnet Synchronous Motors(IPMSMs). The development of this program is based on Matlab. In oder to achieve the development of the program, basis algorithm for IPMSMs analysis took advantage of equivalent magnetic circuit analysis technique. The equivalent magnetic circuit analysis for IPMSMs are based on a rotate synchronous d-q reference frame. The mathematical model of the d-q frame voltage equations is used frequently for the analysis of IPMSMs. This program can consider a cross saturation effect and a iron loss and mechanical loss, and provide fast analysis results of IPMSMs characteristics.

  • PDF

Color and Water Holding Capacity of PSE, RSE, RFN and DFD Pork (PSE, RSE, RFN, DFD 돈육의 육색과 보수력에 관한 연구)

  • Kim, Cheon-Jei;Park, Hong-Yang;Jung, Young-Chul;Kang, Jong-Ok;Lee, Chang-Hyun;Lee, Eui-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.1138-1143
    • /
    • 1997
  • This study was carried out to investigate the meat color and water holding capacity (WHC) characteristics of PSE, RSE (reddish-pink, soft, exudative), RFN (reddish-pink, firm, non-exudative) and DFD pork quality, also the relationship of lightness $(L^*-value)$ and WHC to drip loss were examined. When WHC in M. longissimus dorsi muscle by filter paper press method was measured at 45 min postmortem (45 min p.m.), DFD meat indicated the highest WHC, RSE and RFN pork were significantly different (p<0.05). WHC measured at 24 hr postmortem were not significantly different between RSE and RFN pork (p.0.05). Drip loss (%) were significantly different among the four quality group, but cooking loss (%) of PSE, RSE and RFN pork were not significantly different, except DFD. PSE pork indicated the lowest salt soluble protein solubility. The correlation between drip loss and $L^*-value$ was r=0.61, drip loss increased with increasing $L^*-value$. Also drip loss were moderately correlated with $WHC_{4.5\;min\;p.m.}$ (r=-0.47), with $WHC_{24\;hr\;p.m.}$ (r=-0.52). When drip loss was predictable from $L^*-value$ and WHC, $L^*-value$ was superior to evaluation by WHC.

  • PDF

Primary angle-closure glaucoma, a rare but severe complication after blepharoplasty: Case report and review of the literature

  • Maria Kappen, Isabelle Francisca Petronella;Nguyen, Duy Thuan;Vos, Albert;van Tits, Hermanus Wilhelmus Hendricus Joseph
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.384-387
    • /
    • 2018
  • Blepharoplasty is one of the most commonly performed aesthetic procedures. Surgical complications are rare, but can have severe consequences, such as permanent vision loss. In this report, we describe a patient who developed primary angle-closure glaucoma (ACG) with associated vision loss after a oculoplastic procedure using local anesthesia. So far, six similar cases have been described in the literature. It is believed that acute ACG is triggered by the surgical procedure in patients with predisposing risk factors such as a cataract. Surgical triggering factors include the use of buffered lidocaine/xylocaine with adrenaline/epinephrine, stress, and coverage of the eyes postoperatively. Due to postoperative analgesic use, the clinical presentation can be mild and atypical, leading to a significant diagnostic delay. Acute ACG should therefore be excluded in each patient with postoperative complaints by assessing pupillary reactions. If a fixed mid-wide pupil is observed in an ophthalmologic examination, an immediate ophthalmology referral is warranted. Surgeons should be aware of this rare complication in order to offer treatment at an early stage and to minimize the chance of irreversible vision loss.

Does apical root resection in endodontic microsurgery jeopardize the prosthodontic prognosis?

  • Cho, Sin-Yeon;Kim, Euiseong
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.2
    • /
    • pp.59-64
    • /
    • 2013
  • Apical surgery cuts off the apical root and the crown-to-root ratio becomes unfavorable. Crown-to-root ratio has been applied to periodontally compromised teeth. Apical root resection is a different matter from periodontal bone loss. The purpose of this paper is to review the validity of crown-to-root ratio in the apically resected teeth. Most roots have conical shape and the root surface area of coronal part is wider than apical part of the same length. Therefore loss of alveolar bone support from apical resection is much less than its linear length.The maximum stress from mastication concentrates on the cervical area and the minimum stress was found on the apical 1/3 area. Therefore apical root resection is not so harmful as periodontal bone loss. Osteotomy for apical resection reduces longitudinal width of the buccal bone and increases the risk of endo-perio communication which leads to failure. Endodontic microsurgery is able to realize 0 degree or shallow bevel and precise length of root resection, and minimize the longitudinal width of osteotomy. The crown-to-root ratio is not valid in evaluating the prosthodontic prognosis of the apically resected teeth. Accurate execution of endodontic microsurgery to preserve the buccal bone is essential to avoid endo-perio communication.

Design and Efficiency Analysis 48V-12V Converter using Gate Driver Integrated GaN Module (게이트 드라이버가 집적된 GaN 모듈을 이용한 48V-12V 컨버터의 설계 및 효율 분석)

  • Kim, Jongwan;Choe, Jung-Muk;Alabdrabalnabi, Yousef;Lai, Jih-Sheng Jason
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.201-206
    • /
    • 2019
  • This study presents the design and experimental result of a GaN-based DC-DC converter with an integrated gate driver. The GaN device is attractive to power electronic applications due to its superior device performance. However, the switching loss of a GaN-based power converter is susceptible to the common source inductance, and converter efficiency is severely degraded with a large loop inductance. The objective of this study is to achieve high-efficiency power conversion and the highest power density using a multiphase integrated half-bridge GaN solution with minimized loop inductance. Before designing the converter, several GaN and Si devices were compared and loss analysis was conducted. Moreover, the impact of common source inductance from layout parasitic inductance was carefully investigated. Experimental test was conducted in buck mode operation at 48 -12 V, and results showed a peak efficiency of 97.8%.

Low Conversion Loss 94 GHz MHEMT MIMIC Resistive Mixer (낮은 변환손실 특성의 94 GHz MHEMT MIMIC Resistive 믹서)

  • An Dan;Lee Bok-Hyung;Lim Byeong-Ok;Lee Mun-Kyo;Oh Jung-Hun;Baek Yong-Hyun;Kim Sung-Chan;Park Jung-Dong;Shin Dong-Hoon;Park Hyung-Moo;Park Hyun-Chang;Kim Sam-Dong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.5 s.335
    • /
    • pp.61-68
    • /
    • 2005
  • In this paper, low conversion loss 94 GHz MIMIC resistive mixer was designed and fabricated. The $0.1{\mu}m$ InGaAs/InAlAs/GaAs Metamorphic HEMT, which is applicable to MIMIC's, was fabricated. The DC characteristics of MHEMT are 665 mA/mm of drain current density, 691 mS/mm of maximum transconductance. The current gain cut-off frequency(fT) is 189 GHz and the maximum oscillation frequency(fmax) is 334 GHz. A 94 GHz resistive mixer was fabricated using $0.1{\mu}m$ MHEMT MIMIC process. From the measurement, the conversion loss of the 94 GHz resistive mixer was 8.2 dB at an LO power of 10 dBm. P1 dB(1 dB compression point) of input and output were 9 dBm and 0 dBm, respectively. LO-RF isolations of resistive mixer was obtained 15.6 dB at 94.03 GHz. We obtained in this study a lower conversion loss compared to some other resistive mixers in W-band frequencies.