• Title/Summary/Keyword: Cement thickness

Search Result 270, Processing Time 0.024 seconds

An Experimental Study on Cement Film Thickness Between Casting Restorations and Preparation Walls. (주조물(鑄造物) 접착후(接着後) Cement층(層) 후경측정(厚徑測定)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Park, Ui-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.25-29
    • /
    • 1968
  • The purposes of this study were to measure the film thickness of zinc phosphate cement between the casting restorations and preparation walls. In addition, the differences between finger press and non press techniques after the castings were seated completely on the preparation by an automatic mallet until the cement set were studied. The results were as follows : 1) In full cast crown, the cement film thickness on the side wall was thinner than that on the other walls. 2) In 3/4 crown and inlay, the cement thickness was thinner than that in cast crowns. 3) The cement of great W/P ratio showed thinner thickness than that of little W/P ratio. 4) The continuous finger press after the castings were seated completely on the preparations had few influence on the cement film thickness.

  • PDF

Change of the Cement Mantle Thickness According to the Movement of the Femoral Stem in THRA (인공고관절 치환술에서 대퇴주대 회전에 따른 시멘트막 두께 변화)

  • Park, Yong-Kuk;Kim, Jin-Gon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.2 s.191
    • /
    • pp.140-148
    • /
    • 2007
  • THRA(Total Hip Replacement Arthroplasty) has been widely used for several decades as a viable treatment of otherwise-unsolved hip problems. In THRA surgery, cement mantle thickness is critical to long-term implant survival of femoral stem fixed with cement. Numerous studies reported thin or incomplete cement mantle causes osteolysis, loosening, and the failure of implant. To analyze the effect of femoral stem rotation on cement thickness, in this study, we select two most popular stems used in THRA. Using CAD models obtained from a 3D scanner, we measure the cement mantle thickness developed by the rotation of a femoral stem in the virtual space created by broaching. The study shows that as the femoral stem deviates from the target coordinates, the minimum thickness of cement decreases. Therefore, we recommend development of a new methodology for accurate insertion of a femoral stem along the broached space. Also, modification of the stem design robust to the unintentional movement of a femoral stem in the broached space, can alleviate the problem.

GINGIVAL MARGIAL LEAKAGE AND BONDING PATTERN OF THE COMPOSITE RESIN INLAY ACCORDING TO VARIOUS THICKNESS OF DIE SPACER (Die spacer의 두께에 따른 복합레진 inlay의 치은 변연부 미세누출 및 접착양태에 관한 연구)

  • Park, Tae-Il;Shin, Dong-Hoon;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.152-163
    • /
    • 1995
  • This experiment was performed to observe the adhesion pattern and microleakage in the gingival margin according to variation in the resin cement thickness which results from thickness of Die spacer. which is considered to effect the adaptability of the composite resin inlays. Clearfil CR inlays were fabricated on stone models with CR Sep applicated once and Nice fit twice, 4 times, and 6 times each. After 2nd curing within the CRC-100 oven, CR inlays were cemented with CR inlay cement. Dye(2% methylene blue) penetration and adhesion pattern were evaluated after sectioning of gingival margin into :3 pieces. The results were as follows ; 1. The thickness of resin cement showed unevenchanging pattern with that of die spacer, namely, it was increased until 4 times' application of Nice-Fit but was decreased with 6 times' application of that. 2. The degree of dye penetration wasn't affected by cement thickness within a limited value. 3. Most of dye penetration was shown through the interface between cement and enamel rather than the interface between cement and CR inlay. This shows that the affinity of resin cement for CR inlay was superior to the adhesive strength with tooth structure. 4. No gap was found at the interface between enamel and cement but some showed separation between dentin and cement. It is concidered that the contraction force of cement was less than the bond strength with the enamel. 5. Lots of voids were found in the CR inlay and resin cement. There was a pooling tendency of bonding agent and cement in the axiogingival line angle portion. 6. In some specimens, cracks were shown in enamel margin. From this it could be considered that cavity preparation and surface treatment weakened the tooth structure.

  • PDF

The effects of cement thickness and cement shade on the final color of lithium disilicate crowns

  • Yigit Yamali;Merve Bankoglu Gungor;Secil Karakoca Nemli;Bilge Turhan Bal
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.2
    • /
    • pp.93-100
    • /
    • 2023
  • PURPOSE. The aim of this study is to evaluate the effect of resin cement color, cement thickness, and thermocycling on the final color of monolithic lithium disilicate crowns. MATERIALS AND METHODS. A total of ninety prepared central incisors of typodont teeth were restored with lithium disilicate crowns which have different cement thicknesses (40 ㎛, 80 ㎛, and 120 ㎛) and cement shades (clear, yellow, and white). Color parameters of restorations were measured with a spectrophotometer in three different steps 1) before cementing 2) after cementing and 3) after thermocycling with 10000 cycles. Color differences (ΔE00) were calculated with the CIEDE2000 formula and evaluated according to perceptibility (0.8) and acceptability (1.8) thresholds. The ΔE00 data were analyzed by using two-way ANOVA before and after thermocycling (α = .05). RESULTS. There was no interaction between the cement shade and the cement thickness factors. After cementation, the mean ΔE00 was under the perceptibility threshold in the group of 40 ㎛ cement thickness and clear cement while it was between the perceptibility and acceptability thresholds (0.8 < ΔE00 < 1.8) for all other groups. After thermocycling, the ΔE00 values were between the perceptibility and acceptability thresholds for all experimental groups. Although there were no significant differences among the groups, thermocycling increased the color difference values. CONCLUSION. The cementation of restorations with clear, yellow, and white resin cements resulted in color differences with uncemented restorations except for the group cemented with clear cement in 40 ㎛ cement thickness. All study groups revealed perceptible color change after thermocycling.

Influence of cement thickness on resin-zirconia microtensile bond strength

  • Lee, Tae-Hoon;Ahn, Jin-Soo;Shim, June-Sung;Han, Chong-Hyun;Kim, Sun-Jai
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.3
    • /
    • pp.119-125
    • /
    • 2011
  • PURPOSE. The aim of this study was to evaluate the influence of resin cement thickness on the microtensile bond strength between zirconium-oxide ceramic and resin cement. MATERIALS AND METHODS. Thirty-two freshly extracted molars were transversely sectioned at the deep dentin level and bonded to air-abraded zirconium oxide ceramic disks. The specimens were divided into 8 groups based on the experimental conditions (cement type: Rely X UniCem or Panavia F 2.0, cement thickness: 40 or 160 ${\mu}m$, storage: thermocycled or not). They were cut into microbeams and stored in $37^{\circ}C$ distilled water for 24 h. Microbeams of non-thermocycled specimens were submitted to a microtensile test, whereas those of thermocycled groups were thermally cycled for 18,000 times immediately before the microtensile test. Three-way ANOVA and Sheffe's post hoc tests were used for statistical analysis (${\alpha}$=95%). RESULTS. All failures occurred at the resin-zirconia interface. Thermocycled groups showed lower microtensile bond strength than non-thermocycled groups (P<.001). Differences in cement thickness did not influence the resin-zirconia microtensile bond strength given the same resin cement or storage conditions (P>.05). The number of adhesive failures increased after thermocycling in all experimental conditions. No cohesive failure was observed in any experimental group. CONCLUSION. When resin cements of adhesive monomers are applied over air-abraded zirconia restorations, the degree of fit does not influence the resin-zirconia microtensile bond strength.

THE STUDY ON THE COLOR STABILITY OF RESIN CEMENT USED IN ALL CERAMIC CROWN (전부도재관에 사용되는 레진시멘트의 색안정성에 관한 연구)

  • Lee Tae-Hee;Lee Young-Soo;Park Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.41-48
    • /
    • 2004
  • Statement of problem : The Cement as well as restoration required esthetics for making natural color restoration. Purpose : The purpose of this research is to evaluate color stability of restoration intermediated by resin cement which is used for cementation of all ceramic crown. Material and method : After making Empress 2 ingot into the size of $10mm{\times}10mm{\times}1mm$ according to indication, it glazed and made 48 Empress 2 blocks. Three kinds of resin cement(Rely-X, Variolink 2, Choice) having same shade cemented between Empress 2 blocks and Ivory shade tiles and made 48 specimens in the thickness of $30{\mu}m$ and $80{\mu}m$. After measureing color difference using spectorphotomenter, the result of this study were as follows. Results : The color difference of resin cement used in experiment increased in the order Rely-X, Variolink 2. As the thickness of cement increases, the color difference of all kinds of cement found statistically sifnificant difference but, this result is clinically acceptable. Conclusion : More resarch would have to be done in order to decrease the color difference as cement's thickness.

THE SURFACE HARDNESS OF RESIN CEMENT BY THICKNESS OF PORCELAIN LAMINATE (도재 라미네이트의 두께의 따른 레진 시멘트의 표면경도에 관한 연구)

  • Kang Seok-Koo;Dong Jin-Keun;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.506-514
    • /
    • 1993
  • The purpose of this study was to evaluate the effect of porcelain laminate thickness on polymerization of resin cement. G-Cera resin bonding system(G-C int., Japan) was used in this study and Heliolux II (Vivadent, Austria) was used for polymerization of resin cement. The thickness of porcelain laminates used in this study were 0.5mm, 1.0mm and 1.5mm and the degree of polymerization of resin cement was measured by microhardness theater(Matsuzawa, Model MXT-70, Japan). The obtained results were as follows : 1. The surface hardness of resin cements increaing the thickness of poreclain laminate was decreased. 2. The surface hardness of resin cements increasing the curing time was decreased.

  • PDF

The degree of conversion of dual-cured resin cement as a function of transmittance and thickness (지르코니아 투명도 및 두께에 따른 레진 시멘트의 중합률)

  • Noh, Hyeong-Rok;Joo, Kyu-Ji;Sun, Gum-Ju
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.193-199
    • /
    • 2016
  • Purpose: The purpose of this study was to know of photopolymerization effect of self-etch dual-cured resin cement on different transmittance and thickness of zirconia disks. Methods: The two types of transparent and opaque zirconia speciments were prepared. The five speciments of each groups were seperated with 0.5mm and 1.0mm thickness. Degree of conversion(DC) were studied by FT-IR spectroscopy using ATR method before and after irradidaion for 40 sec. Results: The relative DC was showed the higher results of ZS5 as compared with ZS10 (p < 0.05). And OP5 and OP10 were lower results than ZS10 (p < 0.05). Conclusion: The photopolymerization effect of dual-cured resin cement were affected by the transmittance and thickness of zirconia.

Biomechanical Finite Element Analysis of Bone Cemented Hip Crack Initiation According to Stem Design

  • Kim, Byeong-Soo;Moon, Byung-Young;Park, Jung-Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2168-2177
    • /
    • 2006
  • The purpose of this investigation was to determine the specific fracture mechanics response of cracks that initiate at the stem-cement interface and propagate into the cement mantle. Two-dimensional finite element models of idealized stem-cement-bone cross-sections from the proximal femur were developed for this study. Two general stem types were considered; Rectangular shape and Charnley type stem designs. The FE results showed that the highest principal stress in the cement mantle for each case occurred in the upper left and lower right regions adjacent to the stem-cement interface. There was also a general decrease in maximum tensile stress with increasing cement mantle thickness for both Rectangular and Charnley-type stem designs. The cement thickness is found to be one of the important fatigue failure parameters which affect the longevity of cemented femoral components, in which the thinner cement was significantly associated with early mechanical failure for shot-time period.

A mortar mix proportion design algorithm based on artificial neural networks

  • Ji, Tao;Lin, Xu Jian
    • Computers and Concrete
    • /
    • v.3 no.5
    • /
    • pp.357-373
    • /
    • 2006
  • The concepts of four parameters of nominal water-cement ratio, equivalent water-cement ratio, average paste thickness, fly ash-binder ratio were introduced. It was verified that the four parameters and the mix proportion of mortar can be transformed each other. The behaviors (strength, workability, et al.) of mortar primarily determined by the mix proportion of mortar now depend on the four parameters. The prediction models of strength and workability of mortar were built based on artificial neural networks (ANNs). The calculation models of average paste thickness and equivalent water-cement ratio of mortar can be obtained by the reversal deduction of the two prediction models, respectively. A mortar mix proportion design algorithm was proposed. The proposed mortar mix proportion design algorithm is expected to reduce the number of trial and error, save cost, laborers and time.