• 제목/요약/키워드: Cell-based sensor

검색결과 185건 처리시간 0.026초

광도전성저항을 이용한 열선유속계의 하드웨어적 온도보상에 관한 연구 (Hardware temperature compensation technique for hot-wire anemometer by using photoconductive cell)

  • 이신표;고상근
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3666-3675
    • /
    • 1996
  • A new hardware temperature compensation method for hot-wire anemometer is investigated and an analog compensating circuit is proposed in this article. A photoconductive cell is introduced here as a variable resistor in the anemometer bridge and the linearized output of a thermistor is used to monitor the input of the photoconductive cell. In contrast with the conventional method, any type of temperature sensor can be used for compensation if once the output of thermometer varies linearly with temperature. So the present technique can diversify the compensating means from a conventional passive compensating resistance to currently available thermometers. Because the resistance of a photoconductive cell can be set precisely by adopting a stabilizing circuit whose operation is based on the integration function of the operational amplifier, the accuracy of compensation can be enhanced. As an example of linearized thermometer, thermistor sensor whose output is linearized by a series resistor was used to monitor the fluid temperature variation. Validation experiment is conducted in the temperature ranged from 30 deg. C to 60 deg. C and the velocity up to 40 m/s. It is found that the present technique can be adopted as a compensating circuit for anemometer and hot-wire type airflow meter.

포켈스센서를 이용한 코로나방전 발생시의 전계변화 측정에 관한 연구 (A possible non-contact measuring technique for the variation of the electric field due to corona discharge by use of Pockels sensor)

  • 마지훈;강원종;임윤석;최재옥;장용무;구자윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.189-192
    • /
    • 2001
  • In this paper, an novel optical measuring system based on the electro-optic effect has been proposed and realized using Pockels cell with a view to detecting partial discharge taking place at the needle plane electrode. This system has the following advantages ; nonmetallic probe sensor, immune to external EMI noise and broad band response of the Pockels cell from DC to GHz. This system is constructed by He-Ne laser, Mach-Zehnder interferometer with Pockels sensor, balanced photo receiver, data acquisition board and PC. The response characteristics of the developed proto type sensor are examined for AC and corona discharge.

  • PDF

힘 피드백 기반의 세포조작을 위한 세포막 침습력 측정 (Cellular Force Sensing for Force Feedback-Based Biological Cell Injection)

  • 김덕호;윤석;강현재;김병규
    • 대한기계학회논문집A
    • /
    • 제27권12호
    • /
    • pp.2079-2084
    • /
    • 2003
  • In biological cell manipulation, manual thrust or penetration of an injection pipette into an embryo cell is currently performed by a skilled operator, relying on visual feedback information only. Accurately measuring cellular forces is a requirement for minimally invasive cell injections. Moreover, the cellular force sensing is essential in investigating the biophysical properties for cell injury and membrane modeling studies. This paper presents cellular force measurements for the force feedback-based biomanipulation. Cellular force measurement system using piezoelectric polymer sensor is implemented to measure the penetration force of a zebrafish egg cell. First, measurement system setup and calibration are described. Second, the force feedback-based biomanipulation is experimentally carried out. Experimental results show that it successfully supplies real-time cellular force feedback to the operator at tens of uN and thus plays a main role in improving the reliability of biological cell injection tasks.

부분방전 전계 측정용 $LiNbO_3$ 프루브 센서 제작 (A development of $LiNbO_3$ probe sensor for detecting partial discharge)

  • 강원종;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1041-1043
    • /
    • 1999
  • In this work, a possible new PD detection technique, based on the electro-optic effect, has been proposed. A proto-type probe sensor for detection partial discharge is made by $LiNbO_3$ Pockels cell, diachroic sheet polarizer and right-angle prism. The Mach-Zehnder interferometer system is proposed by using this sensor and this system is applied to detecting high electric field. we show the characteristic of the proto-type probe sensor and the design of a proposed probe type sensor.

  • PDF

힘반향 기반의 바이오매니퓰레이션을 위한 세포 조작력 측정 (Cellular Force Measurement for Force Feedback-Based Biomanipulation)

  • 김덕호;김병규;윤석;강현재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.237-240
    • /
    • 2003
  • In biological cell manipulation, manual thrust or penetration of an injection pipette into an embryo cell is currently performed by a skilled operator, relying on visual feedback information only. Accurately measuring cellular forces is a requirement for minimally invasive cell injections. Moreover, the cellular farce sensing is essential in investigating the biophysical properties for cell injury and membrane modeling studies. This paper presents cellular force measurements for the force feedback-based biomanipulation. Cellular force measurement system using piezoelectric polymer sensor is implemented to measure the penetration force of a zebrafish egg cell. First, measurement system setup and calibration are described. Second, the force feedback-based biomanipulation is experimentally carried out. Experimental results show that it successfully supplies real-time cellular force feedback to the operator at several tens of uN and thus plays a main role in improving the reliability of biological cell injection tasks.

  • PDF

Bluetooth Low-Energy Current Sensor Compensated Using Piecewise Linear Model

  • Shin, Jung-Won
    • 센서학회지
    • /
    • 제29권5호
    • /
    • pp.283-292
    • /
    • 2020
  • Current sensors that use a Hall element and Hall IC to measure the magnetic fields generated in steel silicon core gaps do not distinguish between direct and alternating currents. Thus, they are primarily used to measure direct current (DC) in industrial equipment. Although such sensors can measure the DC when installed in expensive equipment, ascertaining problems becomes difficult if the equipment is set up in an unexposed space. The control box is only opened during scheduled maintenance or when anomalies occur. Therefore, in this paper, a method is proposed for facilitating the safety management and maintenance of equipment when necessary, instead of waiting for anomalies or scheduled maintenance. A Bluetooth 4.0 low-energy current-sensor system based on near-field communication is used, which compensates for the nonlinearity of the current-sensor output signal using a piecewise linear model. The sensor is controlled using its generic attribute profile. Sensor nodes and cell phones used to check the signals obtained from the sensor at 50-A input currents showed an accuracy of ±1%, exhibiting linearity in all communications within the range of 0 to 50 A, with a stable output voltage for each communication segment.

Detecting User Activities with the Accelerometer on Android Smartphones

  • Wang, Xingfeng;Kim, Heecheol
    • Journal of Multimedia Information System
    • /
    • 제2권2호
    • /
    • pp.233-240
    • /
    • 2015
  • Mobile devices are becoming increasingly sophisticated and the latest generation of smartphones now incorporates many diverse and powerful sensors. These sensors include acceleration sensor, magnetic field sensor, light sensor, proximity sensor, gyroscope sensor, pressure sensor, rotation vector sensor, gravity sensor and orientation sensor. The availability of these sensors in mass-marketed communication devices creates exciting new opportunities for data mining and data mining applications. In this paper, we describe and evaluate a system that uses phone-based accelerometers to perform activity recognition, a task which involves identifying the physical activity that a user is performing. To implement our system, we collected labeled accelerometer data from 10 users as they performed daily activities such as "phone detached", "idle", "walking", "running", and "jumping", and then aggregated this time series data into examples that summarize the user activity 5-minute intervals. We then used the resulting training data to induce a predictive model for activity recognition. This work is significant because the activity recognition model permits us to gain useful knowledge about the habits of millions of users-just by having them carry cell phones in their pockets.

Bi-electrolyte Carbon Dioxide Gas Sensor Based on Paste Sodium-Beta Alumina and Yttria-stabilized Zirconia

  • Han, Hyeuk Jin;Park, Chong Ook
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.170-172
    • /
    • 2014
  • $CO_2$ sensor was used only one solid electrolyte in many cases. To improve the sensing characteristics of $CO_2$ sensors, solid electrolyte $CO_2$ sensor has been developed by bi-electrolyte type sensor using Na-Beta-alumina and YSZ. However, in many further studies, bi-electrolyte type sensor was made by pellet pressed by press machine and additional treatment for formation of interface. In the aspect of mass production, using thick film and additional treatment is not suitable. In this study, $CO_2$ sensor was fabricated by bi-electrolyte structure which was made by an NBA paste layer deposited on YSZ pellet and fired at $1650^{\circ}C$ for 2 hour. The formation of stable interface between YSZ and NBA were confirmed by SEM image. When the type IV electrochemical cell arrangement represented by $CO_2,O_2,Pt{\mid}Li_2CO_3-CaCO_3{\parallel}NBA{\parallel}YSZ{\mid}O_2,Pt$ is used to measure the $CO_2$ concentration in air. This sensor EMF should depend only on the concentration of $CO_2$ by logarithmic. Also, sensor shows $P_{CO_2}$ and EMF relationship like nerstian reaction at a temperature of $450^{\circ}C$.

모바일 환경에서 질의응답이 가능한 무선센서노드 라우팅 생체신호 모니터링 시스템 (Vital Sign Monitoring System with Routing and Query of Wireless Sensor Node on Mobile Environment)

  • 이승철;토싱후이;도경훈;정완영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 추계종합학술대회 B
    • /
    • pp.357-360
    • /
    • 2008
  • 본 논문에서는 모바일 환경에서 무선센서노드의 라우팅와 질의응답이 가능하도록 실시간 쿼리 기능, 자율구성 네트워크, 다양한 생체 신호 모니터링을 설계 및 구현하였다. 센서노드에 부착 가능한 any devices(심전도, 혈압, 혈당모듈)는 의사나 건강관리 전문가가 특정한 모듈을 선택적으로 사용할 수 있도록 쿼리 프로세서를 설계하였다. 또한 이 프로세서를 이용하여 모바일 환경에서 자율구성 네트워크 토폴로지가 형성되는 모습을 제어할 수 있도록 하였다. 무선의료 디바이스를 이용한 생체신호는 실시간 분석을 하기 위해 서버 PC에서 분석하는 게 아니라 모바일로 먼저 분석하게 된다. 이는 휴대폰의 데이터 통신 비용을 절약하기 위해서 심전도, 혈압, 혈당과 같은 생체신호는 모바일에서 비정상 생체신호를 검출 후 정밀한 신호처리를 하기 위해서 서버에 보내지도록 구현하였다.

  • PDF

Pockets 효과를 이용한 광전압센서에 관한 연구 (A study on optical voltage sensor using Pockels effect)

  • 박해수;김영수;김요희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.557-560
    • /
    • 1989
  • For the purpose of increasing supply reliabiity in power line, high reliable voltage and current sensors must be needed. This paper describes the principle and result of the only optical voltage sensor based on BSO pockels cell.

  • PDF