• Title/Summary/Keyword: Cell Area

Search Result 3,142, Processing Time 0.03 seconds

Assessment of Phosphoric Acid Fuel Cell Technology (인산형 연료전지 발전 기술)

  • 고영태;이진홍
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.16-21
    • /
    • 1993
  • Power generation technology utilizing fuel cell becomes an area of technological interest due to its superior characteristics such as energy saving and environmental-friendliness. Major emphasis is put un phosphokric acid fuel cell technology in this paper. Current technological status and commercialization effort of phosphoric acid fuel cell are assessed along with the future developmental issues.

  • PDF

Factors Affecting the Development of Embryos Produced by Nuclear Transfer

  • Lee, Joon-Hee;Campbell, Keith H.S.
    • Journal of Embryo Transfer
    • /
    • v.27 no.4
    • /
    • pp.193-203
    • /
    • 2012
  • The development of embryos reconstructed by nuclear transfer is dependent upon numerous factors including the type of recipient cell, method of enucleation, the type of donor cell, method of reconstruction, activation, the cell cycle stage of both the donor nucleus and the recipient cytoplasm and the method of culture of the reconstructed embryos. Many of these points which have been reviewed extensively elsewhere (Sun and Moor, 1995; Colman, 1999; Oback and Wells, 2002; Renard et al., 2002; Galli et al., 2003b), here we will concentrate on main area, the production of suitable cytoplast and nuclear donor, nuclear-cytoplasmic coordination, oocyte activation, culture of reconstructed embryos, and the effects that this may have on development.

3-D Simulation of T-Shaped Electrode and Comparison of Results with Experiments

  • Shin, Yeong-Kyo;Hwang, Tae-Su;Kang, Seok-Dong;Park, Hun-Gun;Ryu, Jae-Hwa;Kim, Hyun-Chul;Shin, Seong-Won;Lee, Jae-Koo
    • Journal of Information Display
    • /
    • v.3 no.2
    • /
    • pp.13-18
    • /
    • 2002
  • Numerical simulation is one of the most useful tools to study gas discharge phenomena that occur in alternating current plasma display panel (AC-PDP) cell. Most PDP cell simulations have been performed for two-dimensional cell, is cross-section along the address electrode. We developed a three-dimensional PDP simulator and applied it to a T-shaped electrode cell in order to show the effects of sustain electrode shape that cannot be included in two-dimensional simulation. The dependence of power consumption on electrode shape and area in the simulation showed the same trend as experiment.

FOFIS : Forest Fire Information Systems (FOFIS: 산불 정보 시스템)

  • 지승도
    • Journal of the Korea Society for Simulation
    • /
    • v.8 no.2
    • /
    • pp.13-28
    • /
    • 1999
  • The main purpose of this paper is to design and implement forest fire information system (FOFIS) for effective prevention of forest fire using GIS, database, 3-D graphics, and simulation techniques. In contrast to conventional fire information systems that are mostly based on the 2-D graphics and analytic modeling approaches, we have proposed the cell-based modeling approaches, i.e., spatial, data, and simulation modeling approaches. The cell-based spatial modeling is proposed by eliminating the cliff effect of the typical elevation model so that it can provide realistic 3-D graphics of the forest fire. The cell-based data modeling of geography, meteorology, and forestry information is also proposed. The cell-based dynamic modeling for forecasting of the fire diffusion is developed using the variable structure modeling techniques. Several simulation tests of FOFIS performed on a sample forest area of Chungdo, Kyungsangbukdo will demonstrate our approaches.

  • PDF

Voltammetric Analysis on a Disposable Microfluidic Electrochemical Cell

  • Chand, Rohit;Han, Dawoon;Kim, Yong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1175-1180
    • /
    • 2013
  • A microfabricated electrochemical cell comprising PDMS-based microchannel and in-channel gold microelectrodes was fabricated as a sensitive and a miniature alternative to the conventional electroanalytical systems. A reproducible fabrication procedure enabled patterning of multiple microelectrodes integrated within a PDMS-based fluidic network. The active area of each electrode was $200{\mu}m{\times}200{\mu}m$ with a gap of $200{\mu}m$ between the electrodes which resulted in a higher signal to noise ratio. Also, the PDMS layer served the purpose of shielding the electrical interferences to the measurements. Analytes such as potassium ferrocyanide; amino acid: cysteine and nucleoside: guanosine were characterized using the fabricated cell. The microchip was comparable to bulk electrochemical systems and its applicability was also demonstrated with flow injection based rapid amperometric detection of DNA samples. The device so developed shall find use as a disposable electrochemical cell for rapid and sensitive analysis of electroactive species in various industrial and research applications.

Continuous Removal of Nitrate and Coliform using Bipolar ZVI Packed Bed Electrolytic Cell (영가철 충진 복극전해조를 이용한 질산성질소 및 대장균의 연속식 제거)

  • Jeong, Joo-Young;Park, Jeong-Ho;Choi, Won-Ho;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.651-658
    • /
    • 2011
  • Nitrate is a common contaminant in industrial wastewater and ground water. The maximum contaminant level set by EPA for nitrate of 10 mg/L as N. In this study, nitrate was removed using bipolar ZVI packed bed electrolytic cell that maximized the contact area between each electrode and contaminants under 600 V. Also this study investigates the simultaneously deals with removal of ammonia by operating air stripping tower. In addition to the air stripping also helped to precipitate iron ions to the form of iron oxides. Bipolar ZVI packed bed electrolytic cell was also effective in removing coliform by electrical power. In the continuous experiments for the simulated wastewater (initial nitrate for 25 mg/L as N), maximum 96.3% removal of nitrate was achieved in the applied 600 V at the flow rate of 6 mL/min.

Optimal cell structure of a wall-cathode and wall auxiliary anode for high performance plasma display panel (벽형의 음극 전극과 보조 전극을 갖는 고효율 플라즈마 표시기의 최적 전극 구조에 관한연구)

  • 신범제;정희섭;서정현;황기웅
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.6
    • /
    • pp.33-42
    • /
    • 1997
  • In this paper, a new structure for a dC plasma display pane(PDP) with a wall-catode and a wall-auxilizry anode has been suggested. The wall-cathode with a sufficient discharge area maximizes the discharge volume. The auxiliary anode surrounding the discharge region makes the effective control of the charged particles possible. We have investigated the cahracteristics of the new cell structure with a 2-dimensional computer simulation and a micro gap discharge system, and compared experimentally with those of previous cell structure. The new cell structure with the wall-cathode and auxiliary wall-anode turned out to have improved luminance, discharge forming time and sustain voltage.

  • PDF

An occurrence of mammary spindle cell carcinoma in a dog

  • Hong, Sunhwa;Lee, Hyun-A;Kim, Dong-Woo;Kim, Tae-Wan;Kim, Okjin
    • Korean Journal of Veterinary Service
    • /
    • v.37 no.4
    • /
    • pp.313-317
    • /
    • 2014
  • A bitch was presented for investigation of the mass in left 5th mammary gland. The partial mastectomy was performed and submitted for the histopathological diagnosis. The mammary mass was firm and white colored. The cut surface was separated with several lobules and developed vessels. The central area of the mass formed the cavity filled with inflammatory exudates. The dominant component of the tumor was the bundles of spindle-shaped cells. Some tumor cells possessed atypical nuclei and were arranged in a solid nest. Cysts were microscopically composed of hemorrhage, necrosis, and exudates, partially surrounded by tumor cells and granulation tissues. Histopathologically, the mammary mass revealed spindle cell carcinoma. The bitch made a complete recovery following the mastectomy. This case was a rare mammary spindle cell carcinoma in a dog.

Spindle Cell Lipoma: A Rare, Misunderstood Entity

  • Seo, Bommie Florence;Kang, In Sook;Oh, Deuk Young
    • Archives of Craniofacial Surgery
    • /
    • v.15 no.2
    • /
    • pp.102-104
    • /
    • 2014
  • Spindle cell lipoma, a rare variant of lipoma, is a benign tumor found in the posterior neck and shoulder. A 24-year-old man with a close family history of malignant lymphoma had presented with a large, firm, nodular mass found in the right supraclavicular area. Excision of the deeply located mass revealed a pale yellow, rubbery nodule which grossly resembled an enlarged lymph node, with a variant of lymphoma as a primary suspect. However, pathological studies revealed the lesion to be a spindle cell lipoma. Although atypical in location, spindle cell lipoma should always be kept in differential diagnosis of a newly-noted soft tissue mass, as this entity may be easily cured by simple excision.

Evaluation of Failure Mechanism of Flexible CIGS Solar Cell Exposed to High Temperature and Humid Atmosphere (플렉서블 CIGS 태양전지의 고온고습 환경 고장 기구 분석)

  • Kim, Hyeok-Soo;Byeon, Jai-Won
    • Journal of Applied Reliability
    • /
    • v.16 no.1
    • /
    • pp.41-47
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate electrical and structural degradation of flexible CIGS sollar cell exposed to high temperature and humid atmosphere. Method: Accelerated degradation was performed for various time under $85^{\circ}C/85%RH$ and then electrical and structural properties were analyzed by 4-point probe method, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray diffraction (XRD). Results: Sheet resistance of the top ITO layer increased with exposure time to the high temperature and humid atmosphere. Blunting of the protrusion morphology of ITO layer was observed for the degraded specimen, while no phase change was detected by XRD. Oxygen was detected at the edge area after 300 hours of exposure. Conclusion: Increase in electrical resistance of the degraded CIGS solar cell under high temperature and humid environment was attribute to the oxygen or water absorption.