• Title/Summary/Keyword: Ceiling unit

Search Result 58, Processing Time 0.022 seconds

Experimental Study of being vehicle cockpit module BSR Noise considering the deterioration condition of the module unit (모듈 단위 열화조건을 고려한 자동차용 칵핏 모듈 이음(BSR Noise)에 대한 시험적 고찰)

  • Yi, Chulhyun;Yang, Jeongmin;Cho, Jinho;Lee, Wonku;Woo, Changsu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.791-795
    • /
    • 2014
  • In this paper, in order to impart the aging condition of the parts, by configuring the cycle of temperature from low temperature was performed by applying the aging conditions for vehicle cockpit module. The reason for the selected modules of the cockpit vehicle parts, because the joint occurrence typical components of the room component is a first module and ceiling cockpit module. After setting the excitation profile using the BSR exciter only that this is for the module degradation after the initial and grasp the change in the dynamic characteristics of the modules based on the before and after deterioration may be made in the module, grasp the noise generating position I measured the noise and proximity. Was also visualized on the position of the joint is generated using a sound camera to objective results occurring where the joint is selected through subjective evaluation.

  • PDF

Development of Dome-Type Cold Storage Facility Using 3-D CFD Simulation (3차원 CFD 시뮬레이션을 이용한 돔형 저온저장고 개발)

  • 양길모;고학균;홍지향
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.35-44
    • /
    • 2003
  • This study was conducted to develop proper model for cold storage facility that could of for uniform heat movement and air movement f3r green grocery and improve improper design of the existing container-type cold storage facility. For that reason, new model(dome-type) cold storage facility was developed using 3-D CFD(computational fluid dynamics) simulation. The size was 6m${\times}$6m${\times}$5m. Its size and configuration were same to simulation model. Unit cooler was designed to send cold air in 4 side ways. A dome-type cold storage facility showed uniform distributions of air temperature and velocity because cold air was forced to move down along the ceiling and the wall and then circulated to the unit cooler from the central part of the floor. Dome-type cold storage facility also showed by low wind velocity, below 1 m/s that could minimized cold damage and quality deterioration.

CFD Based Shape Design of Guide Vane for Fan Filter Unit (전산유체해석을 이용한 Fan Filter Unit(FFU)의 가이드 베인 형상설계)

  • Jang, Jun Hwan;Ahn, Joon;Myong, Hyon Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.709-716
    • /
    • 2013
  • A fan filter unit (FFU) is a device which supplies clean air from the ceiling in a clean room. With an increase in its size, velocity variation occurs within the exhaust plane and this damage the product quality or productivity. Hence, a guide vane is installed inside the device to enhance the velocity uniformity. Because the vane reduces the flow rate for a given pumping power, an optimum design is required to achieve velocity uniformity while minimizing the flow rate reduction at the same time. To find a geometry that satisfies these requirements, a series of numerical simulations has been conducted while changing the angle and length of the guide vanes. By changing the geometry of the side guide vane, the velocity uniformity increased by 3.7% and the flow rate decreased by 1.5%. For the center guide vane, the velocity uniformity increased by 2.9% and the flow rate decreased by 0.7%.

Daylight Assessment of Venetian Blind by Shading Heights and Slat Angles (베네시안 블라인드의 높이와 슬랫각도 조절에 따른 계절별 실내주광분포 분석)

  • Shin, Hwa-Young;Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.105-111
    • /
    • 2011
  • Aims of this study is to investigate the daylighting control strategy of venetian blind system was performed as a function of ratio of shading height to window and slat angles in the preliminary stage of the parametric study. Floor-to-ceiling window walls of living spaces are used widely in apartment buildings since the Korean government has legally allowed elimination of the balcony area. Enlarging living area by balcony elimination, the larger glass area of window is exposed to the direct sunlight. As a common sunlight controlling device, blind system can be used in all orientations and all latitudes and it may obstruct, absorb, reflect and transmit solar radiation to building by proper adjusting. However, blind system can produce discomfort in occupant and less energy efficiency, if it has not been controlled optimally. The simulation model was based on the unit module of typical living space with balcony elimination. The room dimension was $6.0m(w){\times}6.9m(d){\times}2.7m(h)$ with floor to ceiling height of 2.5m. The blind system was simulated at five slat angles (horizontal, $30^{\circ}$, $45^{\circ}$ upward and downward tilted) and the four ratio of shading height to window (fully closed, partly opened, no-blind) using the Desktop RADIANCE 2.0 program. The series of simulation results indicates that the advantages of available daylight and outside of view can be improved by proper adjusting blind system.

Plan Composition Expressed in the Architecture of Art Gallery Designed by Louis I. Kahn - Focus on the Yale University Art Gallery Extension - (Louis I. Kahn의 미술관 건축에 나타난 평면구성에 관한 연구 - Yale University Art Gallery Extension을 중심으로 -)

  • Kim, Hong-Bae
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.3
    • /
    • pp.128-135
    • /
    • 2012
  • The purpose of this study is to investigate and analyze the compositional elements of plan of art museums by selecting architectural works, which have strong symbolic meaning when evaluating value, from architectural works by Louis Kahn. First, the centrality of artworks, which are being displayed at the Yale Art Gallery, is complex. It includes three patterns of Void (spatial) Centrality+Symbolic Centrality+Functional Centrality among the five patterns suggested in this study. Second, the ratio system of interior space, which is expressed in the extension of the Yale Art Gallery, can be classified into the floor and walls. The floor used the square 1:1 ratio system. The ceiling used the grid patterns of equilateral triangles (regular tetrahedrons). It was applying a geometric ratio system when creating forms by using one side as a beam and the other sides as decorations of the ceiling. Third, the contours of interior space, which were expressed in Kahn's works, used the method of forming separate space according to the contouring rule (structural unit) defined by columns, and they were used in constructing the entire space through the integration of separate spaces. Fourth, according to the characteristics that were expressed by artworks displayed within the Yale Art Gallery Extension, the concept of accessibility was not as clear as that of residential buildings, because an approach of respecting existing architecture and context was used, rather than the starting point of interior space, or differentiated circulation, which has the function of a determined position.

  • PDF

Interior Cost Estimating as a Design Marketing Tool - for Executive Office Interior (디자인 마케팅을 위한 인테리어 공사비 초기 예측기법- 일원공간의 인테리어 프로젝트를 중심으로 -)

  • 이혜연
    • Korean Institute of Interior Design Journal
    • /
    • no.23
    • /
    • pp.68-73
    • /
    • 2000
  • The purpose of this research is to develop interior construction cost-estimating system at the early stage of the project. Though general construction estimates are typically in quantitative, interior construction should be in rather qualitative. Therefore, design-concerned cost-estimating methods should be developed to manage interior projects from the early statge. 30 estimates of VIP-Zone interior projects, were examined to develop the general type of composition and material classification. The cost has been classified by construction parts such as wall, ceiling, floor, and doors & windows and their treatments. The composition and material related estimating system (CMRES) was consisted of the unit average costs of classification and the variation coefficients. The CMRESS was verified by the case study, and the results sowed that the difference between the actual estimate and the CMRES was competitively confident.

  • PDF

An Experimental Study on the Operating Characteristics with HVAC Type of Shopping Center in Underground Passage (지하도상가의 HVAC 구성방식에 따른 운전특성 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.76-81
    • /
    • 2007
  • The shopping center in underground passage increased for efficient space utilization in urban area. This study describes operation characteristics of all air type and hybrid type with local ventilation and fan coil unit fixed to ceiling. In order to compare energy saving, thermal environment and installation space, etc., integrated simulator with heat production and indoor distribution system is designed and constructed. Energy saving of the hybrid system is calculated as over 30% compared to conventional all air type. And also the results showed that humidity decreased about 6%, also indoor thermal distribution is improved as temperature variation of around $1^{\circ}C$.

  • PDF

Development of a Moving Monitor System for Growing Crops and Environmental Information in Green House (시설하우스 이동형 환경 및 생장 모니터링 시스템 개발)

  • Kim, Ho-Joon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.3
    • /
    • pp.285-290
    • /
    • 2016
  • In rural area, our farmers confront decreasing benefits owing to imported crops and increased cost. Recently, the government encourage the 6th Industry that merges farming, rural resources, and information and communication technology. Therefor the government makes an investment in supplying 'smart greenhouse' in which a farmer monitor growing crops and environment information to control growing condition. The objective of this study is developing an Moving Monitor and Control System for crops in green House. This system includes a movable sensing unit, a controlling unit, and a server PC unit. The movable sensing unit contains high resolution IP camera, temperature and humidity sensor and WiFi repeater. It rolls on a rail hanging beneath the ceiling of a green house. The controlling unit contains embedded PC, PLC module, WiFi router, and BLDC motor to drive the movable sensing unit. And the server PC unit contains a integrated farm management software and home pages and databases in which the images of crops and environment informations. The movable sensing unit moves widely in a green house and gathers lots of information. The server saves these informations and provides them to customers with the direct commercing web page. This system will help farmers to control house environment and sales their crops in online market. Eventually It will be helpful for farmers to increase their benefits.

Fire Alarm Sound Transmission in Apartment Units (공동주택에서의 화재경보음 전달)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.67-75
    • /
    • 2018
  • To reduce the number of casualties in the case of fire, an alarm sound needs to be delivered to the people who remain in the apartment unit. On the other hand, it was reported that the fire alarm sound generated in the elevator hall was not delivered sufficiently to the people staying in the apartment units. In this study, the background noise level and noise level generated in an apartment unit were measured during the day and night time. In addition, the transmission of the fire alarm sound into the each room of apartment units was simulated and compared with the background noise level. The fire alarm sound generated in the elevator halls was reduced by the fire door and doors, and was not transmitted sufficiently into the internal spaces of the apartment units. Starting evacuation action was difficult after hearing the fire alarm sound generated outside the apartment units. To improve the transmission of an alarm sound to the inner spaces of apartment units, an acoustic simulation was carried out for cases where the alarm sound generator was installed on a wall-pad in the living room and the alarm sound generator was installed on the ceiling of each rooms in apartment units. Background noise of + 15 dB and 75 dB (A) were satisfied when alarm sound generator was installed on the ceiling of each room.

Current Status of MRI Distribution, Prevailing Charges and Analysis of Its Performance (MRI 분포와 관행수가 현황 및 촬영실적 분석)

  • 문옥륜;장원기;이상이;김철웅;최경혜
    • Health Policy and Management
    • /
    • v.8 no.1
    • /
    • pp.155-182
    • /
    • 1998
  • There exists a remarkable differences in use of MRI scanning among income classes. The poor can hardly utilize it. This is because, among high cost technnologies, MRI is the only equipment not covered under health insurance benefits in Korea. This study was designed 1) to reveal the status of nation-wide MRI installation, customary charges and per unit annual scanning performance, and 2) to analyse factors influencing the above variables. The data for this study came from "MRI Prevalence Survey" conducted by the National Federation of Medcial Insurance(NFMI) in 1997, and were analyzed through SAS packages for T-test, analysis of variance and stepwise multiple regression. Data were collected from 188 hospitals equipped with MRI scanners. Major findings are summarized as follows : The number of MRI scanners has increased from 69 in 994 to 158 in 1996(2.3 times) while per unit annual scanning performance has risen by 11.2% from 2,173 cases in 1994 to 2,417 cases in 1996. Such a rapid increase was made possible mainly due to the inclusion of CT scanning under the health insurance benefit package. The customary charges for MRI scanning with or without contrast media, on average, amounted to 484,000 Won and 402,000 Won, respectively, with the percentile increase of 17.8% and 8.1% each during the same time. Korea ranks the third worldwidely in terms of number of MRI installations, 4.8 scanners per one million persons, only next to Japan and United States. Geographical variation of MRI, however, was rather high, 7.91 unit, in Cheju area compared to 1.82 in Kyongnam area. Variations of customary charges of MRI scanning can be explained as much as by 44.8% by both the total amount of claims to NFMI and geographical variable. The charges were more likely to be higher in metropolitan areas like Seoul and in hospitals with a bigger amount of claims. While those of per unit annual scanning performance can be explained as much as by 30.7% by both MRI installation cost and level of MRI-installed organizations. Per capital scannig performance was higher in tertiary hospitals and hospitals equipped with more expensive scanners than hospitals with less expensive scanners. Two measures are called for the remedying the existing excessive abundance in MRI units in korea : One is to set a ceiling of MRI units in an area like a province or a metropolitan district. The other is to establish a committee on introduction of high cost technologies for reviewing its effective use.ctive use.

  • PDF