• 제목/요약/키워드: Cavity temperature

검색결과 603건 처리시간 0.027초

A 4-Channel Multi-Rate VCSEL Driver with Automatic Power, Magnitude Calibration using High-Speed Time-Interleaved Flash-SAR ADC in 0.13 ㎛ CMOS

  • Cho, Sunghun;Lee, DongSoo;Lee, Juri;Park, Hyung-Gu;Pu, YoungGun;Yoo, Sang-Sun;Hwang, Keum Cheol;Yang, Youngoo;Park, Cheon-Seok;Lee, Kang-Yoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권3호
    • /
    • pp.274-286
    • /
    • 2016
  • This paper presents a 4-channel multi-rate vertical-cavity surface-emitting laser (VCSEL) driver. In order to keep the output power constant with respect to the process, voltage, temperature (PVT) variations, this research proposes automatic power and magnitude. For the fast settling time, the high-speed 10-bit time-interleaved Flash-successive approximation analog to digital converter (Flash-SAR ADC) is proposed and shared for automatic power and magnitude calibration to reduce the die area and power consumption. This chip is fabricated using $0.13-{\mu}m$ CMOS technology and the die area is $4.2mm^2$. The power consumption is 117.84 mW per channel from a 3.3 V supply voltage at 10 Gbps. The measured resolution of bias /modulation current for APC/AMC is 0.015 mA.

PCS 대역 세포실험용 전자파 노출 장치 개발 (Development of A Electromagnetic Exposure System for In Vitro Experiments at PCS Band)

  • 박민영;고채옥;성미진;김정란;백정기
    • 한국전자파학회논문지
    • /
    • 제17권4호
    • /
    • pp.335-340
    • /
    • 2006
  • 본 논문에서는 국내 PCS 대역인 1,762.5 MHz의 세포실험용 전자파 노출 장치를 설계 및 제작하였다. 노출 장치는 도파관의 ${\lambda}_g/4$ 지점에 위치한 ${\lambda}_g/8$ 모노폴 안테나에 의해 $TE_{102}$ 모드로 동작되며, 노출 장치 내부에 내부 직경이 8.5 cm인 petri dish 1개를 노출시킬 수 있다. 세포실험용 전자파 노출 장치는 구형 공진기형으로 수치 해석 기법 중 하나인 FDTD 방법을 사용하여 SAR을 해석하였고 온도 프로브(model 790, Luxtron Corp)를 이용해 측정하였다.

세라믹 단열 게이트를 이용한 블로우성형용 PET 프리폼의 백화현상 저감 기술 (Improving the Whitening Phenomenon Technology for Preform PET Injection Molding by Using a Ceramic Insulation Gate)

  • 곽태수;황덕상;강병욱;김태규
    • 한국기계가공학회지
    • /
    • 제16권6호
    • /
    • pp.63-68
    • /
    • 2017
  • The purpose of this study is to improve the whitening phenomenon around the PET preform gate for blow molding. CAE analysis of plastic injection molding has been applied to design of preform shape and select the injection molding conditions. A ceramic insulation gate with lower thermal conductivity than metal is applied to improve the whitening phenomenon created around the gate in the injection molding process. According to the results of CAE analysis, the warpage deformation at the square corner was estimated to be about 0.34 mm at the bottom. From the results of the temperature history analysis, it was confirmed that the resin near the gate cooled more rapidly than the cavity. Ceramic insulated gates were fabricated to reduce the cooling rate and experiments were conducted to confirm the effectiveness of the whitening phenomenon improvement. As a result of the ceramic insulation gate experiment, it was confirmed that the whitening phenomenon was significantly reduced around the gate.

Development of Respiration Sensors Using Plastic Optical Fiber for Respiratory Monitoring Inside MRI System

  • Yoo, Wook-Jae;Jang, Kyoung-Won;Seo, Jeong-Ki;Heo, Ji-Yeon;Moon, Jin-Soo;Park, Jang-Yeon;Lee, Bong-Soo
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.235-239
    • /
    • 2010
  • In this study, we have fabricated two types of non-invasive fiber-optic respiration sensors that can measure respiratory signals during magnetic resonance (MR) image acquisition. One is a nasal-cavity attached sensor that can measure the temperature variation of air-flow using a thermochromic pigment. The other is an abdomen attached sensor that can measure the abdominal circumference change using a sensing part composed of polymethyl-methacrylate (PMMA) tubes, a mirror and a spring. We have measured modulated light guided to detectors in the MRI control room via optical fibers due to the respiratory movements of the patient in the MR room, and the respiratory signals of the fiber-optic respiration sensors are compared with those of the BIOPAC$^{(R)}$ system. We have verified that respiratory signals can be obtained without deteriorating the MR image. It is anticipated that the proposed fiber-optic respiration sensors would be highly suitable for respiratory monitoring during surgical procedures performed inside an MRI system.

비개착식 지반공동 긴급복구를 위한 충전재료 개발에 관한 기초 연구 (Fundamental study on the development of Filling materials for Trenchless Emergency Restoration of Ground cavity)

  • 유남재;한중근;이강일
    • 한국지반신소재학회논문집
    • /
    • 제16권2호
    • /
    • pp.97-107
    • /
    • 2017
  • 최근 도심지에서 지반함몰이 많이 발생하고 있으며 복구작업시 현장 주변 통제로 매우 복잡하고 불편하고 복구대책 공법으로 그라우팅 및 흙메우기 공법이 적용되고 있지만 지반 내 지하수위의 존재 및 공동상태에 따라 재료분리 현상이 발생하거나 많은 양의 복구재료가 요구되는 경우가 많고 지하수의 흐름에 따라 지반 내에서 유실되는 경우도 발생하고 있어 본 연구는 도심지에서 지반함몰이 발생하고 신속하게 복구하는 것을 목표로 지반공동의 긴급보강을 위해 비개착식 공법에 적용할 파우치형 충전재를 개발하는 것으로 지하수의 온도에 따라 충전재의 압축강도 및 팽창비가 다른 것과, 알루미나 파우더의 혼합을 통해 압축강도와 팽창률을 조절할 수 있음을 확인했다.

Crystallographic Analysis of Ar Encapsulate within Cs3-A Zeolite

  • Lim, Woo Taik;Kim, Bok Jo;Park, Jong Sam;Chang, Chang Hwan;Jung, Sung Wook;Heo, Nam Ho
    • 분석과학
    • /
    • 제15권6호
    • /
    • pp.540-549
    • /
    • 2002
  • The arrangement of encapsulated Ar atoms in the molecular-dimensioned cavities of fully dehydrated zeolite A of unit-cell composition $Cs_3Na_8HSi_{12}Al_{12}O_{48}$ ($Cs_3$-A) has been studied crystallographically to probe the confinement effect of guest species in microporous environment. Atoms of Ar were encapsulated in the cavities of $Cs_3$-A by treatment with 410 atm of Ar at $400^{\circ}C$ for two days, followed by cooling at room temperature. The crystal structure of $Cs_3Na_8H$-A(4Ar) ($P_e$ = 410 atm, $a=12.245(2){\AA}$, $R_1=0.0543$, and $R_2=0.0552$) has been determined by single crystal X-ray diffraction technique in the cubic space group $Pm\bar{3}m$ at 21 (1) $^{\circ}C$ and 1 atm. Encapsulated Ar atoms are distributed in three crystallographic distinct positions: 1.5 Ar atoms per unit cell opposite 6-rings, 1.5 opposite four-rings in the large cavity, and finally 1.0 in the sodalite-unit. The possible structures of argon clusters, such as $Ar_2$, $Ar_3$, and $Ar_4$, are proposed.

543 nm 헬륨네온 레이저의 주파수 안정화를 위한 I2 포화흡수분광 (I2-Saturated Absorption Spectroscopy for Frequency-Stabilization of He-Ne Laser at 543 nm)

  • 김경찬;엄년식;홍주현;서호성
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.859-865
    • /
    • 2010
  • 본 연구는 543 nm 헬륨네온 레이저의 주파수 안정화를 위한 $^{127}I_2$ 포화흡수분광 장치의 설계와 제작에 관한 것이다. 온도와 PZT 변화에 의한 레이저관 길이 가변을 이용하여 543 nm 헬륨네온 레이저의 주파수를 주사시켰다. 3차 고조파 신호을 얻기 위해 PZT 변조 가능한 레이저 출력경을 이용하여 주파수 변조를 하였다. 그 결과, $^{127}I_2$용 B-X 시스템의 R(12) 26-0에서 R(106) 28-0의 천이를 가지는 초미세구조 분광은 포화흡수분광기를 사용한 3차 미분신호에서 관찰되었다. 또한, 전형적인 초미세구조 분광 신호의 신호대 잡음비는 약 30:1 로 얻어졌다.

Stimulated Emission with 349-nm Wavelength in GaN/AlGaN MQWs by Optical Pumping

  • Kim, Sung-Bock;Bae, Sung-Bum;Ko, Young-Ho;Kim, Dong Churl;Nam, Eun-Soo
    • Applied Science and Convergence Technology
    • /
    • 제26권4호
    • /
    • pp.79-85
    • /
    • 2017
  • The crack-free AlGaN template has been successfully grown by using selective area growth with triangular GaN facet. The triangular GaN stripe structure was obtained by vertical growth rate enhanced mode with low growth temperature of $950^{\circ}C$ and high growth pressure of 500 torr. The lateral growth rate enhanced mode of AlGaN for crack-free and flat surface was also investigated. Low pressure of 30 torr and high V/III ratio of 4400 were favorable for lateral growth of AlGaN. It was confirmed that the $4{\mu}m$ -thick $Al_{0.2}Ga_{0.8}N$ was crack-free over entire 2-inch wafer. The dislocation density of $Al_{0.2}Ga_{0.8}N$ was as low as ${\sim}7.6{\times}10^8/cm^2$ measured by cathodoluminescence. Based on the high quality AlGaN with low dislocation density, the ultraviolet laser diode epitaxy with cladding, waveguide and GaN/AlGaN multiple quantum well (MQW) was grown by metalorganic chemical vapor deposition. The stimulated emission at 349 nm with full width at half maximum of 1.8 nm from the MQW was observed through optical pumping experiment with 193 nm KrF laser. We also have fabricated the deep ridge type ultraviolet laser diode (UV-LD) with $5{\mu}m-wide$ and $700{\mu}m-long$ cavity for electrical properties. The turn on voltage was below 5 V and the resistance was ${\sim}55{\Omega}$ at applied voltage of 10 V. The amplified spontaneous emission spectrum of UV-LD was also observed from pulsed current injection.

다이오드 여기 Nd:YVO4 단일모드 녹색광 레이저의 출력 특성 연구 (A study on the lasing characteristics of diode-pumped, single-mode Nd:YVO4 green laser)

  • 이용우;이종훈
    • 한국광학회지
    • /
    • 제14권3호
    • /
    • pp.292-297
    • /
    • 2003
  • 최대 1.9 W의 레이저 다이오드 출력을 Nd:YV $O_4$결정 단면에 집속시키고 공진기 내부에 KTP 결정을 두어서 제2고조파 변환시켜 녹색광(532 nm) 레이저를 발생시켰다. 다이오드 레이저 스퍽트럼과 레이저 결정의 흡수 스펙트럼을 비교하여 최적의 다이오드 작동 온도를 찾았다. 공진기 길이와 출력경의 곡률을 변화시키면서 출력의 변화를 관측한 결과, 최대 80 ㎽의 녹색광 레이저 출력을 얻었으며 최대 출력을 내는 공진기 조건에서는 집속된 여기광의 직경과 TE $M_{00}$ 모드의 직경이 일치함을 알았다. 발생된 녹색광 레이저는 다중모드로 발진하였으며 출력 요동이 심하였다. 단일모드 발진을 시키기 위하여 브루스터 판과 에탈론 등을 사용하는 여러 가지 형태의 공진기를 시도하여 보았다. 실험 결과, 에탈론을 사용한 공진기에서 가장 큰 출력인 60 ㎽ 의 단일 종모드 출력을 얻었다. 단일모드로 발진하는 레이저의 출력 요동은 다중 모드에 비하여 1/10이하로 감소하였다.

자동차 반도체의 신뢰성 테스트 표준: AEC-Q100 (Test Standard for Reliability of Automotive Semiconductors: AEC-Q100)

  • 이성수
    • 전기전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.578-583
    • /
    • 2021
  • 본 논문에서는 반도체의 신뢰성을 테스트하기 위한 가속 시험에 대해 설명하고 자동차 반도체의 신뢰성 테스트 국제 표준인 AEC-Q100에 대해 다룬다. 반도체는 수십년 동안 사용할 수 있기 때문에 수명 전주기에서 발생하는 잠재적인 문제점을 테스트하기 위해서는 집중적으로 스트레스를 가하여 테스트 시간을 최소화하는 가속 시험이 필수적이다. 자동차 반도체에서 사용하는 대표적인 가속 시험인 AEC-Q100은 반도체에서 발생하는 각종 불량과 그 원인을 분석할 수 있도록 설계되었기 때문에 반도체의 수명과 신뢰성을 예측할 수 있을 뿐만 아니라 설계상, 제조상의 문제도 쉽게 찾아낼 수 있다. AEC-Q100은 가속 스트레스 시험, 가속 수명 시험, 패키지 적합성 시험, 공정 신뢰성 시험, 전기적 특성 시험, 결함 검출 시험, 기계적 특성 시험의 7개 테스트 그룹으로 구성되며 동작 온도에 따라 Grade 0에서 Grade 3까지 4개의 등급이 존재한다. 반도체 소자, 광전자 반도체, 센서 반도체, 멀티 칩 모듈, 수동 소자 분야에서는 각각 AEC-Q101, Q102, Q103, Q104, Q200이 사용된다.