• 제목/요약/키워드: Cavity temperature

검색결과 605건 처리시간 0.024초

Dependence of superconductivity on the crystallinity of Nb films on Si wafers

  • Choi, Joonyoung;Kim, Chang-Duk;Jo, Younjung
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.1-5
    • /
    • 2021
  • Among elemental metals, niobium (Nb) has the highest superconducting transition temperature (Tc) at ambient pressure. Thus, Nb films have been used in superconducting electronics and radio frequency cavity applications. In this study, the depositional factors determining the crystallinity and Tc of Nb films were investigated. An Nb film grown at a sputtering temperature of 240℃ exhibited the maximum crystallinity of Nb and the minimum crystallinity of niobium oxide. X-ray photoelectron spectroscopy confirmed a maximum atomic percent of niobium and a minimum atomic percent of oxygen. A sputtering power of 210 W and a sputtering time of 50 min were the optimal conditions for Nb deposition, and the Tc of the optimized film (9.08 K) was close to that of bulk Nb (9.25 K). Transmission electron microscopy images of the thick film directly confirmed the removal of the typical in-plane compressive strain in the (110) plane caused by residual stress.

A Vapor Sensor Based on a Porous Silicon Microcavity for the Determination of Solvent Solutions

  • Bui, Huy;Nguyen, Thuy Van;Nguyen, The Anh;Pham, Thanh Binh;Dang, Quoc Trung;Do, Thuy Chi;Ngo, Quang Minh;Coisson, Roberto;Pham, Van Hoi
    • Journal of the Optical Society of Korea
    • /
    • 제18권4호
    • /
    • pp.301-306
    • /
    • 2014
  • A porous silicon microcavity (PSMC) sensor has been made for vapors of solvent solutions, and a method has been developed in order to obtain simultaneous determination of two volatile substances with different concentrations. In our work, the temperature of the solution and the velocity of the air stream flowing through the solution have been used to control the response of the sensor for ethanol and acetone solutions. We study the dependence of the cavity-resonant wavelength shift on solvent concentration, velocity of the airflow and solution temperature. The wavelength shift depends linearly on concentration and increases with solution temperature and velocity of the airflow. The dependence of the wavelength shift on the solution temperature in the measurement contains properties of the temperature dependence of the solvent vapor pressure, which characterizes each solvent. As a result, the dependence of the wavelength shift on the solution temperature discriminates between solutions of ethanol and acetone with different concentrations. This suggests a possibility for the simultaneous determination of the volatile substances and their concentrations.

상온-저온 RF 커플러 유한요소해석 (Finite Element Analysis of RF Coupler in Normal-Low Temperature)

  • 김한솔;이학용;박찬;이재열;임동열;유정훈;현명욱
    • 대한기계학회논문집A
    • /
    • 제38권10호
    • /
    • pp.1101-1107
    • /
    • 2014
  • 중이온 입자가속기는 중이온을 radio frequency (RF) 주파수로 가속하는 장치이다. RF 공동부에 인가된 전기장은 입력된 RF 파에 의해 전자기파의 위상에 맞춰 중이온을 연속적으로 가속한다. 이를 위해서는 안정적으로 RF 파를 공동부 내부에 전달할 수 있는 커플러의 형상설계가 요구된다. 중이온 가속기에서의 RF 커플러는 입력부와 RF 주파수의 파를 방출하는 커플러 양 끝단 간의 온도차이가 매우 크다. 이 온도차를 극복하기 위해선 초저온(약 0K)부터 상온 간(약 300K)의 열 변형을 고려한 해석 및 설계기술이 필요하다. 본 연구는 RF 커플러의 구조에 따른 출력 전기장의 세기와 온도 분포, 열 손실과 열 변형을 고려한 내구도 분석을 통해 성능 향상을 위한 방안들을 도출하는 것을 목적으로 하였다.

In vivo verification of regional hyperthermia in the liver

  • Noh, Jae Myoung;Kim, Hye Young;Park, Hee Chul;Lee, So Hyang;Kim, Young-Sun;Hong, Saet-Byul;Park, Ji Hyun;Jung, Sang Hoon;Han, Youngyih
    • Radiation Oncology Journal
    • /
    • 제32권4호
    • /
    • pp.256-261
    • /
    • 2014
  • Purpose: We performed invasive thermometry to verify the elevation of local temperature in the liver during hyperthermia. Materials and Methods: Three 40-kg pigs were used for the experiments. Under general anesthesia with ultrasonography guidance, two glass fiber-optic sensors were placed in the liver, and one was placed in the peritoneal cavity in front of the liver. Another sensor was placed on the skin surface to assess superficial cooling. Six sessions of hyperthermia were delivered using the Celsius TCS electro-hyperthermia system. The energy delivered was increased from 240 kJ to 507 kJ during the 60-minute sessions. The inter-session cooling periods were at least 30 minutes. The temperature was recorded every 5 minutes by the four sensors during hyperthermia, and the increased temperatures recorded during the consecutive sessions were analyzed. Results: As the animals were anesthetized, the baseline temperature at the start of each session decreased by $1.3^{\circ}C$ to $2.8^{\circ}C$ (median, $2.1^{\circ}C$). The mean increases in temperature measured by the intrahepatic sensors were $2.42^{\circ}C$ (95% confidence interval [CI], 1.70-3.13) and $2.67^{\circ}C$ (95% CI, 2.05-3.28) during the fifth and sixth sessions, respectively. The corresponding values for the intraperitoneal sensor were $2.10^{\circ}C$ (95% CI, 0.71-3.49) and $2.87^{\circ}C$ (1.13-4.43), respectively. Conversely, the skin temperature was not increased but rather decreased according to application of the cooling system. Conclusion: We observed mean $2.67^{\circ}C$ and $2.87^{\circ}C$ increases in temperature at the liver and peritoneal cavity, respectively, during hyperthermia. In vivo real-time thermometry is useful for directly measuring internal temperature during hyperthermia.

Vapor Bubble Nucleation : A Microscopic Phenomenon

  • Kwak, Ho-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제18권8호
    • /
    • pp.1271-1287
    • /
    • 2004
  • In this article, vapor bubble nucleation in liquid and the evaporation process of a liquid droplet at its superheat limit were discussed from the viewpoint of molecular clustering (molecular cluster model for bubble nucleation). For the vapor bubble formation, the energy barrier against bubble nucleation was estimated by the molecular interaction due to the London dispersion force. Bubble nucleation by quantum tunneling in liquid helium under negative pressure near the absolute zero temperature and bubble nucleation on cavity free micro heaters were also presented as the homogenous nucleation processes.

$YBa_2Cu_3O_{7-x}$초전도 단결정 성장 (Crystal Growth of Superconducting $YBa_2Cu_3O_{7-x}$ Single Crystals)

  • 정광철;오근호;최종건
    • 한국세라믹학회지
    • /
    • 제27권4호
    • /
    • pp.536-542
    • /
    • 1990
  • Single crystals of YBa2Cu3O7-x have been grown in BaCuO2 flux at temperature of 125$0^{\circ}C$ and examined using XRD, EDAX and light microscopy. The YBCO crystals were grown in a cavity which was formed by the reduction of CuO and became large by the directional solidification in the crucible. The observed crystal growth habit is square planar with the c-axis normal to the plane. The surface morphology of grown crystals were growth ledges and growth sprial paterns on a (001) face.

  • PDF

임상가를 위한 특집 2 - 심미수복용 레진 (Tooth-colored Restorative Resin Composites)

  • 권태엽
    • 대한치과의사협회지
    • /
    • 제51권1호
    • /
    • pp.12-17
    • /
    • 2013
  • Curing methods for denial resin-based materials are limited because of the need to polymerize quickly in the oral cavity at an ambient temperature. At present, most dental restorative composites use a camphorquinone-amine complex initiation, visible light-cure, one-component systems. Clinically, it is important to try to optimize the degree of conversion of res in composites using proper manipulation and adequate light-curing techniques to ensure the best outcome.

Microwave Sintering of FLY Ash Substituted Body and Numerical Analysis

  • Kim, S. B.;J. W. Han;Kim, Y.
    • 한국결정성장학회:학술대회논문집
    • /
    • 한국결정성장학회 1998년도 PROCEEDINGS OF THE 14TH KACG TECHNICAL MEETING AND THE 5TH KOREA-JAPAN EMGS (ELECTRONIC MATERIALS GROWTH SYMPOSIUM)
    • /
    • pp.75-76
    • /
    • 1998
  • Fly ash 70wt% contained green bodies were sintered by using a 2.45 Ghz microwave oven and their properties were investigated. Samples were sintered at 1,150$^{\circ}C$ and kept at that temperature up 50 minutes by 10 minutes intervals. Numerical analysis on the microwave heated system was carried out in order to figure out the heat transfer phenomena in the cavity.

  • PDF

고온용 히트파이프형 태양열 흡수기 (High-Temperature Heat-Pipe Type Solar Thermal Receiver)

  • 부준홍;정의국
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.668-671
    • /
    • 2007
  • A numerical study was conducted on a simplified model of a high-temperature solar receiver which incorporates liquid-metal heat pipe. The objective of this paper is to compare the isothermal characteristics of the heat pipe receiver with the conventional receiver utilizing convection of molten salt as heat carrier. The solar receiver was assumed to be subject to a concentration ratio between 50 and 1,000 to supply high-temperature heat to a stirling engine for electric power generation. For simplicity of the analysis, a cylindrical geometry was assumed and typical dimensions were used based on available literature. The heat pipe had a shape of double-walled cavity and the working fluid was a sodium. The analysis was performed assuming that the radiation heat flux on the inner walls of the receiver was uniform, since the focus of this study was laid on the comparison of the conventional type and heat pipe type receiver. The results showed that the heat pipe type exhibited superior performance when the operating temperature becomes higher. In addition, to explore the advantage of the heat pipe receiver, the channel shape and dimensions should be adjusted to increase the heat transfer area between the wall and the heat trnasfer medium.

  • PDF

무전지 SAW 기반 마이크로 통합센서 및 무선 측정기술 개발 (Development of Batteryless SAW-based Integrated Microsensor and Wireless Measurement Technique)

  • 오해관;김태현;왕웬;양상식;이기근
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1430-1435
    • /
    • 2007
  • We developed a 440MHz surface acoustic wave (SAW) microsensor integrated with pressure-temperature sensors and ID tag. Two piezoelectric substrates were bonded, in which ${\sim}150\;{\mu}m$ cavity was structured. Four sides were completely sealed by JSR photoresist (PR). Pressure sensor was placed on the top substrate, whereas ill tag and temperature sensor were placed on the bottom substrate. Using network analyzer, the developed microsensor was wirelessly tested. Sharp reflection peaks with high S/N ratio, small signal attenuation, and small spurious peaks were observed. All the reflection peaks were well matched with the coupling of mode (COM) simulation results. With a 10mW RF power from the network analyzer, a ${\sim}1$ meter readout distance was observed. Eight sharp ON reflection peaks were observed for ID tag. Temperature sensor was characterized from $20^{\circ}C$ to $200^{\circ}C$. A large phase shift per unit temperature change was observed. The evaluated sensitivity was ${\sim}10^{\circ}/^{\circ}C$.