• Title/Summary/Keyword: Cavity 유동

Search Result 408, Processing Time 0.023 seconds

Numerical Study on Flow and Heat Transfer Enhancement in a Cooling Passage with Protrusion-In-Dimples (돌출부를 포함한 딤플 표면을 가진 냉각 유로에서의 유동과 열전달 성능 향상에 관한 수치적 연구)

  • Kim, Jeong-Eun;Ha, Man-Yeong;Yoon, Hyun-Sik;Doo, Jeong-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.805-814
    • /
    • 2011
  • In the present study, the detailed flow structure and heat transfer characteristics in the newly-designed heat transfer surface geometry were investigated. The surface geometry proposed in the present study is a traditional dimple structure combining with a protrusion inside the dimple, which is named a protrusion-in-dimple in this study. The basic idea underlying the present surface geometry is to enhance the flow mixing and the corresponding heat transfer in the flow re-circulating region generated by a conventional dimple cavity. The present study was performed by the direct numerical simulation at a Reynolds number of 2800 based on mean velocity and channel height and Prandtl number of 0.71. Three different protrusion heights for protrusion-in-dimples were considered as the main design parameter of the present study. The calculated pressure drop and heat transfer capacity were assessed in terms of the Fanning friction factor and Colburn j factor. The overall performances estimated in terms of the volume and area goodness factor for protrusion-in-dimple cases were higher than the conventional dimple case.

A Study on the Determination System of Process Conditions for Moldability by Using Fuzzy Logic (퍼지논리에 의한 최적 성형조건 결정 시스템에 관한 연구)

  • 강성남;허용정
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.1
    • /
    • pp.1-4
    • /
    • 2002
  • A short shot is a molded part that is incomplete because insufficient material was injected into the mold. Any factors that increase the resistance of polymer melt to flow or prohibit delivery of sufficient material into the cavity can cause a short shot. Inappropriate injection pressure is one of the most common factors which cause a short shot. Conventionally, domain experts in injection molding decide and modify the pressure based on their experience. It is difficult for a non-expert to decide the pressure properly with the considerations such as a part dimension, shape, and other processing variables. In this study, fuzzy algorithm is proposed to standardize the empirical determination of the pressure so that not only the experts but also non-experts can find the appropriate injection pressure easily. To acquire the more accurate results. domain experts should be interviewed and then technical documents which are collected from the experts should be restored in the fuzzy rule base. But in this study, simulations have been done by using C-MOLD to settle the rule base because it takes much time and also it's difficult to meet and interview the experts.

  • PDF

System Performance Variation for Relative Location of Pre-swirl Nozzles and Receiver Holes in Radial On-Board Injection Type Pre-swirl System (반경방향 분사방식 프리스월 시스템의 프리스월 노즐과 리시버 홀의 상대적 위치에 따른 시스템 성능변화)

  • Lee, Jonggeon;Lee, Hyungyu;Cho, Geonhwan;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.1
    • /
    • pp.43-53
    • /
    • 2020
  • The effect of the relative location between pre-swirl nozzle and receiver hole on the performance of radial on-board injection type pre-swirl system was analyzed. In this study, tendency of the change of discharge coefficient and temperature drop efficiency were analyzed for 20 design points through the combination of 5 pre-swirl nozzle location and 4 receiver hole location. Discharge coefficient of system tended to be similar to the pressure ratio of the pre-swirl nozzle. System performance variation occurred as the flow structure in the cavity was affected by the surface, and the influence of the stationary surface is greater than that of the rotating surface. Discharge coefficient of system changed -1.39% to 1.25% and temperature drop efficiency changed -5.41% to 2.94% refer to reference design point.

The Microleakage in Class V Cavity Based on Different Kinds of Several Dentin Adhesive and Composite Resin (5급 와동에서 수종의 상아질 접착제와 복합레진의 종류에 따른 미세누출)

  • Choi, Yoo-Seok;Jeong, Soon-Jeong;Jeong, Moon-Jin;Ahn, Yong-Soon;Park, Seon-Nyeo;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.13 no.3
    • /
    • pp.330-338
    • /
    • 2013
  • In order to explore microleakage in class V cavity based on different kinds of several dentin adhesive and composite resin, 2 kinds of composite resin was restored and exposed after applying 4 kinds of dentin adhesives. Deposited in methylene blue solution for 4 hours and cut in parallel with tooth longitudinal axis. By observing dye penetration level of enamel and dentin margins of each restored resin following conclusion was obtained. 1. In composite resin Filtek Z350XT Universal (3M/ESPE Dental Products, USA) in enamel margin, Easy Bond (3M/ESPE Dental Products) showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2 (3M/ESPE Dental Products), Scotchbond Multi-Purpose (3M/ESPE Dental Products) and Cearfil SE Bond (Kuraray Medical Inc., Japan). In case of Filtek Z350XT Flowable (3M/ESPE Dental Products), Scotchbond Multi-Purpose showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2, Clearfil SE Bond and Easy Bond. 2. In case of Filtek Z350XT Universal in dentin margin, Easy Bond showed the lowest microleakage and this leakage was represented to be high in the order of Scotchbond Multi-Purpose, Single Bond 2 and Clearfil SE Bond. In case of Filtek Z350XT Flowable, Scotchbond Multi-Purpose and Single Bond showed the lowest microleakage and this leakage was represented to be high in the order of Clearfil SE Bond and Easy Bond. 3. In all the groups excepting S-U group (Single Bond 2+Filtek Z350XT Universal), enamel margin showed more higher microleakage than that of dentin margin. 4. There was a difference between enamel and dentin margin among each group but it was not significant statistically (p>0.05). When summarizing this result, it is considered that composite resin and dentin adhesive could be applied selectively and particularly in case of applying 1-step self-etching dentin adhesive, this method would be advantageous for manipulation convenience and shortening of operation time.

GET Imaging Evaluation of Patients with Esophageal Cancer (식도암 환자의 GET 영상 평가)

  • Moon, Jong Wun;Lee, Chung Wun;Seo, Young Deok;Yun, Sang Hyeok;Kim, Yong Keun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • Purpose: Measure gastric emptying time (GET: Gastric Emptying Time) is a non-invasive and quantitative evaluation methods, mainly by endoscopic or radiological examination confirmed no mechanical obstruction in patients with symptoms of congestion is checked. Such tests are not common gastric emptying time measured esophageal cancer patients (who underwent esophagectomy) patients after surgery for gastric emptying time was measured test. And the period of time for more than one year after the gastric emptying time measurement was performed. By comparing the two kinds of tests in the chest cavity after surgery as the evaluation of gastrointestinal function tests evaluate the usefulness of GET, and will evaluate the characteristics of the image. Materials and Methods: 93 patients who underwent esophagectomy with gastric emptying time measurement of subject tests immediately after surgery and after 1 year or longer were twice. Preparation of the patient before the test is more than 12 hours of overnight fasting is important, in addition to the medicine or to stop smoking, and diabetes insulin injections should be early in the morning is ideal to test. Generally labeled with $^{99m}Tc-DTPA$ resin which is used to make steamed egg, seaweed and fermented milk with a high viscosity after eating, three hours in the standing position was measured. Evaluation of gastric emptying curves on the way intragastric radioactivity level by 50% the time (half-time [T1/2]) was calculated, based on the half-life was divided into three steps: over 180 minutes was defined as delayed gastric emptying, within 180minutes was defined as intermediate gastric emptying and when all the radioisotopes were dumped into the jejunum as soon as swallowed, was defined as rapid gastric emptying. Results: Gastric emptying time of a typical images stomach of antrum and fundus additional images appear stronger over time move on to the small intestine. but esophageal cancer who underwent esophagectomy side of the thoracic cavity showed a strong image. Immediately after surgery, the half-time (T1/2) of rapid gastric emptying appeared to 12.9%, intermediate gastric emptying appeared to 52.7%, delay gastric emptying appeared to 34.4%. After more than a year the results of the half-life after surgery, 67% of rapid gastric emptying to intermediate gastric emptying was changed, 69% of delay gastric emptying to intermediate gastric emptying changed. Intermediate gastric emptying worse in patients rapid gastric emptying and the delay gastric emptying is 24% in the case. Conclusion: Esophagectomy for esophageal cancer who underwent half-time measurement test (T1/2) rapid gastric emptying and delay gastric emptying are the result of the comparison over time, changes were observed intermediate gastric emptying. Mainly seeing of gastric emptying time measurement in the esophagus instead of thoracic cavity to check the evaluation of gastrointestinal function can be useful even means. And segmentation criteria and narrow time interval of checking if more accurate information and analysis of the clinical diagnosis and evaluation seems to be done.

  • PDF

A CASE REPORT OF A DENTIGEROUS CYST TREATED BY MARSUPIALIZATION (조대술을 이용한 함치성 낭종의 치험례)

  • Jun, Eun-Min;Kim, Tae-Wan;Kim, Hyun-Jung;Nam, Soon-Hyeun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.473-480
    • /
    • 2007
  • The dentigerous cyst originates through alteration of stellate reticulum after amelogenesis has completed, with accumulation of fluid between the layers of the reduced enamel epithelium or between this epithelium and the tooth crown. Its incidence is relatively high on 10s or 20s of age and it is always related to the unerupted crown. Generally, it has no symptom, however, if the cyst is large or accompanied with pus formation, swelling and pain may occur. In radiographic findings, it shows impacted crown surrounded by well defined unilocular radiolucent lesion and occasionally displacement of adjacent teeth or root resorption. The goal of treatment is complete elimination of abnormal tissue preserving the tooth involved in the cyst. Enucleation and marsupialization are commonly used for the treatment. Marsupialization is the procedure which removes the partial portion of the cystic wall and connects with the oral mucosa. As the pressure in the cyst decreases, bone regeneration takes place in the defect area and cystic wall converts into normal mucosa. This procedure, however, is the most conservative procedure which allows the protection of adjacent important structures. If the eruption space is sufficient, then inducing the eruption of the permanent tooth in the cyst is also possible. In following cases, dentigerous cyst was diaganosed after clinical and radiographic examination. Marsupialazation was done to remove the cyst and induce the tooth, which was in the cyst, to erupt into the oral cavity.

  • PDF

Spawning Behavior and Early Life History of Endangered Cottus hangiongensis (멸종위기에 처한 한둑중개(Cottus hangiongensis)의 산란습성 및 초기생활사)

  • Seo, Won-Il;Yoo, Dong-Jae;Byun, Soon-Gyu;Kim, Yi-Cheong;Lee, Sung-Hun;Yeon, In-Ho;Han, Kyeong-Ho;Yim, Hu-Soon;Lee, Bae-Ik
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.43 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • Spawning behavior and early life history of the tuman river sculpin, Cottus hangiongensis were studied in the laboratory and in the field at Wangpi Stream, Gyeongsangbuk-do, Korea, from January to December, 2007. The spawning ground was in the lower Wangpi Stream, which is a shallow region about 40cm or less in depth. During the spawning period, from March to April, mature males made nest cavities under stone 10 which they led a gravid female. The male and female then turned upside down, and spawning and fertilization occurred onto the ceiling of the nest cavity. After spawning, the male chased the female from the nest and mated with several other females. Fertilized eggs were spherical in shape, demersal, adhesive, transparent and yellow in color, measuring 1.86 mm (1.79~1.93 mm) in diameter. A mean of 17(12~22) various-sized oil globules were counted in the yolk. Granular materials formed a mass in the yolk. Fertilized eggs hatched at 256 hrs, 10 minutes after the morula stage under water temperature of $15.0{\sim}18.0^{\circ}C$. Newly hatched larvae 9.34 mm (9.02~9.69 mm. n=10) in total length (TL) had a large yolk At 14 days after hatching, larvae 11.40 mm (11.07~11.72 mm, n=10) in TL transformed to the postlarval stage. At 41 days after hatching, postlarvae of 18.42 mm (17.31~18.62 mm, n=10) in TL had reached the juvenile stage. The result of this study indicate that Cottus hangiongensis has the spawning ground in the lower stream and the amphidromous life history which is the different from that of Cottus poecilopus.

Optimization Condition for Injection Molding of TV Speaker Grille Using CAE (CAE를 이용한 TV Speaker Grille 사출 성형의 최적화)

  • 김범호;장우진;김정훈;정지원;박영훈
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.855-865
    • /
    • 2001
  • The optimization condition of injection molding for a commercial product of TV speaker grille of A Company was induced using a CAE software of Moldflow. The flow and packing phase analysis was performed by using flow balance, runner balance, and the intermediate one by using the above two balances, which were used for controlling the amount of packing resins into the cavity, Later, the analysis performed by using the measured viscosity (local database) at various shear rates and the results were compared with the computer simulation using the standard database. Flow balance induced minimized weld line resulted in a better appearance and physical properties of the were line, but exhibited a disadvantage of large deformation and gas formation due to over-packing of the molten resin in the center of the speaker grille. Runner balance improved the disadvantage of the flow balance by controlling the amount of molten resin injected from the gate, however resulted reduced mechanical properties and poor appearance of the weld line. However, the modified method induced from the flow and runner balance improved the disadvantages by changing the runner size. In addition, the analyses based on the local database and the standard database were compared. Although the measured viscosity was slightly higher and the temperature distribution was broader than the standard database, no distinct difference was obtained from the analysis using the two different databases.

  • PDF