• 제목/요약/키워드: Cause of fire

검색결과 819건 처리시간 0.024초

성시(聲嘶)의 원인(原因)에 대(對)한 문헌적(文獻的) 고찰(考察) (A Bibliographic Study on the Cause of Hoarse Voice)

  • 한대길
    • 대한한방내과학회지
    • /
    • 제12권1호
    • /
    • pp.98-104
    • /
    • 1991
  • I studied some important medical Literatures in order to examine the cause of Hoarse Voice and found out some facts of follows ; 1. The exogenous cause of disease in wind. 2. Wind-cold, Wind-fire, Wind-heat, Summer-heat, Heat. 3. The endogenous cause of disease is deficiency of Yin and dificiency of blood leads fire-evil was lung-dry stool dificiency of body fluid. 4. The non-exo-endogenous causes of disease is sing ballads and call out.

  • PDF

화재감식평가 자격개발에 관한 연구 (Study on the Development of Qualification for Fire Identification and Estimation)

  • 이수경;김영철;오형술;정기신;송동우;김태훈
    • 한국화재소방학회논문지
    • /
    • 제24권3호
    • /
    • pp.78-85
    • /
    • 2010
  • 현재 화재조사 및 감식을 하는 기관은 소방, 경찰을 비롯하여 화재안전관련 기관 등으로 다양하며 이에 종사하는 인력들도 상당수에 이르고 있으나 이들의 전문성에 대한 어떠한 객관적인 지표가 없는 것이 현실이다. 본 연구에서는 직무분석을 통하여 검정기준을 마련, 시험제도의 시행방안을 제시하였고, 화재감식 평가 자격에 적합한 검정과목과 출제기준을 개발하여 화재현장에서 발화원인, 연소상황, 피난상황, 소방시설 등의 상황을 조사하고, 화재피해조사, 화재 분석 및 평가 등의 업무를 수행할 수 있는 공신력 있는 화재감식평가기사 국가기술자격 종목을 개발하고자 한다.

매연포집필터 과열로 발생한 디젤승용차화재 원인의 분석 (Analysis of a Car Fire Case Caused by the Overheating of a Diesel Particulate Filter)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제31권1호
    • /
    • pp.89-97
    • /
    • 2017
  • 본 연구에서는 서비스센터에서 정비를 받고 출고한 날로부터 5일 후 터널 주행 중에 발생한 디젤승용차 화재 사례를 조사분석하였다. 조사분석한 결과, 배기구 내부에 흰색 이물질이 다량 부착되어 있었고, 배기관의 중간에 설치된 diesel particulate filter (DPF) 위쪽의 차열재가 용융 및 소실되어 있었고, DPF 위쪽의 차실 내부 금속재 바닥이 천공되어 금속재 바닥 위에 놓인 고무매트가 연소된 케이스이었다. 그리고 DPF 앞쪽의 배기관에는 과열흔적이 없고 DPF부터 배기구까지의 배기관에 과열흔적이 있는 특이점이 있었다. 이러한 특이점들은 DPF가 과열되고 DPF에서 발화된 경우에만 나타나므로 이 승용차화재는 DPF 내부 과열에 의해 발생한 것으로 분석할 수 있었다. 그리고 이 승용차화재조사를 통해 디젤승용차 화재원인조사 과정에서 배기구 내부에서 흰색 이물질이 확인되는 경우에는 DPF를 분리하여 DPF 내부의 손상을 조사하여 화재원인을 판정하여야 함을 알 수 있었다.

우리나라의 화재조사제도 개선에 관한 연구 (A Study on the Improvement of the Fire Investigation System In Korea)

  • 고기봉;최돈묵
    • 한국화재조사학회지
    • /
    • 제11권1호
    • /
    • pp.155-166
    • /
    • 2007
  • 본 연구에서는 현행 우리나라의 화재조사 제도에 관한 전반적인 운영실태를 살펴봄으로써 문제점을 도출하고 그 해결방안을 모색하고자 한다. 문제점으로는 화재조사 법률의 기능별 분산 적용, 각 기관별 독자적인 화재조사 실시, 민간 화재조사전문가 제도 전무, 화재조사 전문 연구기관 미비, 화재조사 정보공유 시스템 취약, 방화 원인조사 시스템 취약을 들 수 있으며, 개선방안으로는 화재조사 법률 통합, 유관기관 합동조사, 민간 화재조사전문가 제도 조기 도입, 화재조사 전문 연구기관 확충, 화재조사 정보 공유를 위한 제도 도입, 방화 원인조사를 위한 화재조사팀 운영을 들 수 있다.

  • PDF

과부하 및 물리적 손상(반단선)에 의한 전선의 열적특성 해석 (Analysis for the Thermal Properties of the Electrical Wire according to Overload and Disconnection)

  • 김성철;김두현
    • 한국안전학회지
    • /
    • 제22권4호
    • /
    • pp.26-31
    • /
    • 2007
  • According to the statistical analysis on the electrical fire of 2005 years, most of electrical fire is generated from short circuit(4,985 cases), overcurrent(755 cases) leakage current(391 cases), poor contact(378 cases), disconnection(36 cases) on the electrical wiring device. The researches for the fire hazard about normal electric wiring have already been progressing in the advanced country such as USA and Japan, but Comparative study of the disconnection has not been conducted. Therefore, in this paper, we have simulated the thermal analysis for electrical wire according to deteriorating time in a normal state and disconnection with electrical wire using the electrical-thermal finite element method(Flux 3D). This paper acquire basis data of electricity fire signal by disconnection and wish to help for electrical fire cause diagnosis business.

제조결함이 법원에서 인정된 차량화재 사례의 분석 (Analysis of a Car Fire Case Deciding at Courts that a Fire Broke Out due to Manufacture Defect)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.94-103
    • /
    • 2016
  • 이 논문에서는 1년 전에 구입하여 8,500 km를 주행한 차량에서 발생한 화재사례를 분석하였다. 이 차량은 차량이 적색교통신호로 멈추었다가 파란불로 바뀌어 출발할 때 옆 차량이 경음기를 울려서 차량을 세워 확인해보니 엔진 쪽에 불이 붙어 있었다. 이 차량 화재는 배터리 + 단자에 삽입하여 나사로 조이는 고리의 전기적인 스파크로 인해 발생하였을 가능성이 높은 것으로 분석하였다. 그리고 그 고리의 전기적인 스파크는 제조결함으로 인해 발생한 것이므로 화재발생책임은 소유자나 운전자와 관련이 없이 제조자에게 있는 것으로 분석하였다. 이 차량화재의 화재발생책임과 관련하여 법원에서 제조자의 제조결함을 인정하였다.

금원시대(金元時代)의 의서(醫書)에 나타난 신경정신질환(神經精神疾患)에 대한 고찰(考察) (The literatural study of investigating the contents associated with the neuropsychosis in the medical books published in the times of Chinese dynasty of Jin and Yuan)

  • 채종걸;이상용
    • 혜화의학회지
    • /
    • 제9권1호
    • /
    • pp.725-743
    • /
    • 2000
  • This study was intended to investigate the contents associated with the neuropsychosis in the medical books published in the times of Chinese dynasty of Jin and Yuan. As a result, the following findings were drawn. 1. As for palpitation from fright and severe palpitation, the medical schools in the times of Chinese Jin and Yuan dynasties viewed their causes as heart-fire, shuiqichengxin, blood vacuity, phlegm and so on and presented a prescription for each cause for them. 2. As for psychosis, medical books published in the times of Chinese Jin and Yuan dynasties accurately divided and discussed epilepsy and viewed their causes largely as Yangming heat, phlegm of chest and heart-fire. And a number of medical schools made use of such therapeutics as sweating, vomiting and diarrhea therapies. 3. As for headache, medical books published in the times of Chinese Jin and Yuan dynasties presented their causes as fire and heat, phlegm heat, phlegm and so on and classified the aspect of headache in detail. As for vacuity rexation and dysphoria, medical books at that time saw their causes as fire and heat, heart-fire, blood vacuity and so forth and presented a prescription for them accordingly. 4. Liu Wan Su was the Hanliang school. He viewed the etiological cause for psychopathy as fire and heat and prescribed largely the medication of cold nature for it. 5. Zhang Cong Zheng belonged to the Gongxia School. He viewed the etiological cause for psychopathy as fire, phlegm and so forth and made use of sweating, vomiting and diarrhea therapies. Especially, he used the 'Jingzhepingzhe' therapy as a method to treat the symptom of fright. 6. Li Gao did not any specific mention of psychopathy and divided headache due to internal injury and headache due to external contraction. 7. Zhu Zhen Heng viewed most of the etiological causes for psychopathy as phlegm, fire and deficiency of blood and attached importance to such its therapeutics as resolving phlegm, cleaning away fire and nourishing Yin. 8. Wang Hao Gu did not present the specifically common etiological cause and prescription for psychopathy but described the cause and prescription for headache, dysphoria, maniac speech, palpitation and so forth. Luo Tian Yi presented the process of psychosis due to abnormal therapy for cold demage and prescription of it. 9. Wang Lu made a detailed explanation about the therapeutics of five types of stagnated syndrome and said that stagnated syndrome became the major cause for them in the occurrence of such psychopathy. Wei Yi Lin presented the prescription and medication for comparatively diverse mental diseases such zhong-qi, severe palpitation, palpitation for fright, impaired memory, vacuity rexation, headache, psychosis.

  • PDF

전력릴레이 고장사고 사례분석 및 고장예측 알고리즘 연구 (A Study on Fault Prediction Algorithm and Failure Instance Analysis of Electric Power Relay)

  • 김용규;곽동걸;이승철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.15-16
    • /
    • 2015
  • According to 2014 fire statistical yearbook in the National Fire Data System, a main cause of fire is electrical fire except carelessness fire. Joint/contact badness is the one of the main cause of electrical fire. Furthermore, power relays which are used in electric panel board, motor control center and automation controller, are main element of automation system in the industry field. Overload, voltage unbalance and open-phase due to joint/contact badness of terminal make electric accidents or electrical fires. In order to prevent joint/contact badness of terminal, this paper proposes a sensing circuit of chattering, tracking, arc current, voltage unbalance and open-phase etc. Some experimental tests of the proposed apparatus confirm practicality and validity of the theoretical results.

  • PDF

부천 LPG 충전소 사고 원인에 대한 연구 (Discussions on the Cause of Bucheon LPG Station Accident)

  • 윤재건
    • 한국안전학회지
    • /
    • 제16권3호
    • /
    • pp.31-34
    • /
    • 2001
  • Cause of Bucheon LPG refueling station accident could not be clearly verified because of opposite talking of men reponsible for the accident the accident, damaged by BLEVE and fire, and no systematic fire investigation. After two and half years, recently first judgement has been carried out. But competitive arguement is going on and first leak point of massive LPG will not be clearly identified with evidences acquired by now. This accident gave us many instructions and advices. Specially, massive LPG leak can result in pool fire and safety of underground-installed storage tank is proved by no damage in the strong BLEVE.

  • PDF

스프링클러 소방설비의 부식에 관한 연구 (A Study on Corrosion of Sprinklers System Fire Protection)

  • 김동준;고흥;남궁승태
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.41-48
    • /
    • 2008
  • We studied on corrosion of sprinklers system fire protection, a cause on corrosion of fire installations and a source of the problem. We investigated the influence of fluid mechanics on the corrosion shape of sprinklers system fire protection installations. And we known a problem of early fire extinguishing in fire protection with corrosion.

  • PDF