• Title/Summary/Keyword: Cause of fire

Search Result 821, Processing Time 0.031 seconds

Development of Risk Assessment Index in Special Management Target Facilities According to the Fire Occurrence Factors (화재발생 요인에 따른 특정관리대상시설등의 위험도 평가 지수의 분석 및 개발)

  • Park, Mi Yun;Park, Jong Bok;Park, Jae Hak
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.2
    • /
    • pp.61-70
    • /
    • 2012
  • The range of special management target facilities is seperated by the building sector and the field of civil engineering. In the present study, the risk analysis was performed, related to fire occurred for the last five years, in the field of residential and non-residential facilities in buildings. Most of fire incidents occurred in residential and non-residential facilities was the cause of the electrical, and the resulting casualties were also very high. Therefore, based on the results, the risk evaluation index was developed, identifying the causes of fire occur and doing the fire vulnerability analysis for each facility. The result of this study can be utilized safety management to these facilities for the future, especially, inducing a more specialized and intensive safety management.

Study on Verification of Applicability for a Warehouse Construction Site using a Fire Risk Assessment Tool (화재위험도 평가 Tool에 의한 물류창고 공사장 적용성 검증에 관한 연구)

  • YongGoo Seo;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.673-688
    • /
    • 2023
  • Purpose: Fires that occur during construction are infrequent, but cause great damage. Recently, with the growth of the logistics and distribution industry, the number of construction sites for new logistics warehouses is increasing, so it was selected as a research subject and research was conducted to reduce accidents at construction sites through the development of a fire risk assessment tool to quantitatively approach fire prevention. Method: A comprehensive fire risk assessment tool was accumulated by classifying the work in progress, classifying combustibles and ignition sources by grade, excluding air (oxygen), which is difficult to control, and additionally substituting evacuation safety. Result: Using the developed and proposed fire risk evaluation tool, excavation work with low fire risk, facility construction with medium fire risk, and finishing work with high fire risk were sampled to derive the result (CGI). Conclusion: In this study, it was possible to establish specific preventive measures and evaluate evacuation safety by controlling physical conditions (combustibles) and energy conditions (ignition sources) according to the risk assessment by developing a tool that can evaluate the risk of 14fire occurrence at construction sites. It is expected that in the future, through the application of the fire risk evaluation tool at construction sites, it will be provided as a criterion for establishing a process plan that can reduce risk and evaluating the adaptability of firefighting equipment.14

A Study on the Delay Effect of Smoke Diffusion by the Installation Intervals and the Blockage Ratio of the Fire Smoke Diffusion Delay Device in a Great Depth Underground Double-Deck Tunnel (대심도 복층터널 화재연기 확산지연장치 설치간격 및 차폐율에 따른 화재연기 지연효과 연구)

  • Yang, Yongwon;Han, Jaehee;Lee, Yuntaek;Moon, Jungjoo;Shin, Taegyun
    • Journal of the Korean Society of Mineral and Energy Resources Engineers
    • /
    • v.55 no.6
    • /
    • pp.596-603
    • /
    • 2018
  • The traffic congestion is frequently occurring due to increasing demand for vehicles and development of subcenter in roads of domestic-downtown. The design of a Great depth underground double-deck tunnel planned for construction as a solution however it's mainly for a compact-car. Its low height and small section cause causalities when fire occurs. From this study, the delay system for fire smoke diffusion is developed to minimize the occurrence of casualties when fire occurs in the Great depth underground double-deck tunnel and the CFD(Computational Fluid Dynamics) is used to find the optimal installation interval and the blockage ratio to maximize the system effects. The study analyzed the shorter the installation interval of the system, the higher the smoke delay effect but the efficiency-change tends to be slight above a certain distance and the larger the blockage ratio, the higher the effect but the efficiency-difference is slight according to installation interval.

Fire Mechanism in Power Connection Points of Outlets and Suggestion of a New Identification Method (콘센트 전원 접속구 화재 발생 메커니즘 고찰과 새로운 감식 방법 제시)

  • Park, Jin-Young;Bang, Sun-Bae;Eun, Hee-Rim;Oh, Se-Hyeok;Lee, Yoo-Bin;Ko, Young-Ho
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.76-84
    • /
    • 2020
  • Most outlet fires occur around plug pins and plug pin receivers. However, no research has been conducted on ignitions at power connection points. This study confirms the possibility of ignition after incomplete connection, using a stranded wire, to the power connection point of an outlet. The experiment was divided into basic and reproducing experiments. The basic experiment confirmed the possibility of ignition according to the number of wire strands connected to the power connection point, and it identified the characteristics of the residue after the fire. In the reproducing experiment, lamps, vacuum cleaners, and heaters were connected to an outlet to check if the ignition at the connection advanced into a fire. The fire advanced due to the heat and arc generated at the connection point, and partial losses were identified in the U-type holder and clip. Accordingly, the results demonstrate that a fire may occur when the stranded wire is incompletely connected to the outlet. Moreover, it was confirmed that the cause of a fire can be determined based on the characteristics of the residue.

Effect of Absorbent Thickness on the Noise Level Reduction of Fire-Extinguishing Nozzle (흡음재 두께가 소화노즐 소음도 저감에 미치는 영향)

  • Kim, Hak-Sun;Hwang, In-Ju;Kim, Youn-Jea
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.99-104
    • /
    • 2019
  • In a gas system fire extinguishing system, extinguishing agents are usually stored with approximately 280 bar at $21^{\circ}C$ and are released at approximately 8 MPa through the decompression valve and orifice to quickly suppress the fire. When extinguishing agents are discharged, they cause a loud noise (approximately 140 dB), which can damage electronics, such as hard disk drives (HDDs). Therefore, the noise is becoming a serious issue in the gas extinguishing system. The method of the noise reduction by adding an absorbent is most general and in this study, the thickness of the absorbent was as a selected design variable. The noise level at the observation point and the flow characteristics inside the nozzle were numerically calculated and analyzed using the commercial code ANSYS CFX ver. 18.1.

Study on Fire.Explosion Accidents Prediction Model Development of LPG Vaporizer (LPG 기화기의 화재.폭발사고 예측모델개발에 관한 연구)

  • Ko, Jae-Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.28-36
    • /
    • 2010
  • We have garnered 3,593 data of gas accidents reported for 12 years from 1995, and then analyzed the LPG vaporizer accidents according to their types and causes based on the classified database. According to the results the gas rupture has been the most common accident followed by the release, explosion and then fire accidents, the most frequent accident-occurring sub-cause is LPG check floater faults. In addition, we have applied the Poisson Probability Functions to predict the most-likely probabilities of fire, explosion, release and rupture with the LPG vaporizer in the upcoming 5 years. In compliance with Poisson Probability Functions results, in the item which occurs below 3 "LPG-Vaporizer-Fire", in the item which occurs below 5 "LPG-Vaporizer-Products Faults-Check Floater" and the item which occurs below 10 appeared with "LPG-Vaporizer-Products Faults". From this research we have assured the successive database updating will highly improve the anticipating probability accuracy and thus it will play a key role as a significant safety- securing guideline against the gas disasters.

A Study on the Effect of Compressed Air Using Air-breathing Upon Human (공기호흡기용 압축공기가 인체에 미치는 영향에 대한 연구)

  • 이창우;이용재;현성호;성재만;최돈묵;윤명오
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.95-102
    • /
    • 2004
  • This paper has analyzed compressed air-breathing that fire fighters use in Korea. And the local and the foreign standards for compressed air have been compared. Through the survey, it has been found that over 75% of all the respondents have ever had simple abnormal symptoms after wearing air respirators, and among the abnormal symptoms, nausea and headache are most frequent. Maintenance and exchange of compressor filters were poor and it can be another cause of abnormal symptom of fire fighters. Korea does'nt have any particular standards for compressed air-breathing, and the compressed air that is used by fire fighters is not different from air for industrial use. However, advanced countries like Europe, Canada and America, they have special standards for compressed air-breathing that fire fighters use. Through the analysis of components of the compressed air used in Korea, it has been found that all the samples have more water than the international standards.

A Study on Combustion Experiments of Multi Type Air-Conditioner Outdoor Units by Large Scale Calorimeter (라지스케일 칼로리미터에 의한 멀티시스템형 에어컨실외기의 연소실험에 관한 연구)

  • Min, Se-Hong;Bae, Yeon-Jun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.168-177
    • /
    • 2011
  • The combustion test for real box of AC outdoor unit has been performed in this study in order to estimate the fire hazard in multi-system type of AC outdoor unit which is currently used for commercial use. The result showed that in test, there was explosion inside of AC outdoor unit, and flame erupted and fire spread through upper side grill. And then this fire burnt the combustibles such as wires, electronic control board, heat exchange copper plate and plastics etc inside the unit, refrigerant gas pipe was burst due to fire, and accelerated the explosion and flame eruption to outside while the refrigerant was erupting. It is found in this test that the maximum heat release rate of AC outdoor unit is 5,830 kW, the maximum internal temperature measured with infrared camera and thermocouple is $1,201^{\circ}C$, maximum ambient temperature is $881^{\circ}C$, and flame rose higher than about 5 m. It is concluded that the fire in AC outdoor unit cause fire to combustibles around the unit, and may give big damage by generating the secondary fire. It is expected that the result obtained from the test on the real object may be applied to fire realization of AC outdoor unit and estimation of fire spreading to the combustibles around in the future computer simulation.

Treatment of Numbness in Hyungsang Medicine (마목의 형상의학적 치료)

  • Kang Kyung Hwa;Son Jae Ik;Kim Kyung Chul;Lee Yong Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.4
    • /
    • pp.879-892
    • /
    • 2003
  • This thesis makes a review of symptoms and cause of the numbness in the literature. clinical case are studied and classified according to the Hyungsang of the patients. The followings are the conclusions: In case of Dam type persons, numbness is mainly caused by Fire with blood deficiency and so cured by tonifying the Jung and blood. In case of Bang Kwang type persons. it is generally caused by the deficiency of Ki and damp-phlegm and treated by reinforcing Ki and removing dampness. Persons of Jung and Hyal types are apt to be afflicted with numbness of deficiency symptoms which can be cured by tonifying the Jung and blood. Those of Ki and Shin types are inclined to get numb from the congestion and stagnancy and so treated by promotion the flow of Ki, dispelling stagnancy, resolving phlegm and promoting digestion. Numbness is common to the old people and women. The deficiency of blood and primordial energy is a cause of old people's numbness. Women get numb due to the pent-up feelings and emotional disturbance. The function disharmony of five Jang and six Bu makes the body lose the control of heat and cold or deficiency and excessiveness, which can be a cause of numbness. Especially the deficiency of the spleen results in numbness. When the special parts of the body become numb treatment must be decided after due consideration on which of the Jang and Bu or meridians is related to that affected area. In case of person with six meridian types. unbalance of Ki and blood leads the six atmospheric influences(wind, cold, heat, dampness, dryness and fire) get into the body through the most developed meridian and brings in numbness.

A study of methods for Acupuncture and moxibustional treatment to Insomnia (불면(不眠)에 대한 침구치료(鍼灸治療)의 접근 방법론 연구 - 경락생리(經絡生理) 및 혈성(穴性)을 중심으로 -)

  • Kim, Geun-Woo
    • Korean Journal of Acupuncture
    • /
    • v.21 no.3
    • /
    • pp.147-158
    • /
    • 2004
  • Objectives : This study was aimed to investigate the methods for acupuncture and moxibustional treatment to insomnia Methods : The insomnia is classified by seven cause at main subject. According to this, arrange the acupuncture and moxibustional treatment for classical books, and explain eight meridian related to insomnia. Results : 1. Insomnia means deficiency of sleeping and it is the word generally used when a short period of sleeping, difficulty for deep sleeping and difficulty for recovery of original vital energy comes out. In oriental medicine, they understand that uneasiness condition occurred by abnormal operation of the internal organs as heart, liver, gallbladder, spleen, stomach, kidney, etc. caused by external affection or internal injury becomes Insomnia. 2. Cause of insomnia can be classified majorly as fire-transformation of liver and gallbladder , inner shaking of phlegm-heat , insufficiency of both the heart and the spleen, disharmony between heat and kidney, the dysfunction of the stomach, timidity of heart and gallbladder, the deficiency of Qi of the lung. They make insomnia with bad influence upon body and spirit. 3. The meridian system such as Heart Meridian of Hand Soeum, Pericardium Meridian of Hand Gworeum, Stomach Meridian of Foot Yangmyeong, Spleen Meridian of Foot Taeeum, Bladder Meridian of Foot Taeyang, Kidney Meridian of Foot Soeum, Gallbladder Meridian of Foot Soyang, Liver Meridian of Foot Gworeum and Lung Meridian of Hand Taeeum are used to treat insomnia. Sinmun acupoint and Naegwan acupoint are often used in particular because the they are good for calmming the spirit, the heart and purging the heart of (pathogenic) fire. 4. Especialy, Back-Su points of Bladder Meridian of Foot Taeyang was used by each causes. The Back-su Points was mainly used for heal the insomnia because the Back-Su points has good competent to control the ability of internal organs by direct effect to it. It is because the vitality flows through around back-Su. Conclusions : It comes to a conclusion as follows with research for relevancy of the main cause of insomnia and meridian system includes meridian point.

  • PDF