Analysis of Electrical Installation Survey at Conventional Markets (재래시장 전기설비 실태조사 분석)

  • Lee, Sang-Ick;Jeon, Hyun-Jae;Kim, Gi-Hyun;Bae, Seok-Myung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.186-191
    • /
    • 2008
  • The conventional markets is badly damaged by a big fire because of no proper fire fighting management system. The cause of electricity fire is the aging and contact badness of electric equipment. The supervisory detecting system is needed to develop because the electric equipment is located to non visible and non exposing place. In this paper, we investigated the receiving and distributing board, the panel board and the fire prevention system of 17 domestic conventional markets. As a result of survey, capacity of distributing boards is mainly 600A and materials of distributing boards are synthetic resins 49%, metal 44%. ELB is mainly used as branch circuit breaker.

An Empirical Study on the Sprinkler Operational Characteristics and Escape Time Estimation (스프링클러 작동특성(作動特性)과 피난평가(避難評價)에 관한 실증적(實證的) 연구(硏究))

  • Jin, Bok-Kweon
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.3
    • /
    • pp.37-50
    • /
    • 2006
  • The trends in building construction these days are moving towards having better work spaces and greater suitability for the use of information technology. Therefore people can work in a more relaxed delightful and pleasant environment. Accident such as like fire could cause the mass destruction of human beings. This paper aims to evaluate the path of the spread of a fire and the suitability of fire fighting appliances for maximum egress time. General advanced phase of compartment. Aswell, we analyzed and verified the path of the flame in compartment fires. Also we conducted an analysis of the adaptation of sprinkler systems concerned with sprinkler RTI. Moreover those evaluation is made more earlier by the development and use of computer simulation program and rapid progress to apply PBFD (Performance Based Fire Design).

Mechanical and Electrical Properties of Overhead Conductor due to Forest Fire (산불에 노출된 가공송전선의 기계적 및 전기적 특성 거동)

  • Kim, Byung-Geol;Jang, Young-Ho;Kim, Shang-Shu;Han, Se-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.11
    • /
    • pp.1042-1048
    • /
    • 2008
  • Forest Fire can cause a serious damage to overhead conductors. Therefore, the detailed investigation for the changes of mechanical and electrical properties of damaged conductors should be carried out to understand the effect of forest fires on conductors. This is very much important to maintain transmission line safely. Especially, this paper describes the changes of mechanical and electrical properties of flame exposed conductor. Overhead conductors temperature were almostly 55$\sim$65% of ambient temperature. Tensile Strength decreased according to incerase of Forest Fire temperature. The detailed will be given in the text.

Structural Design Guide Line of Composite Beam (내화피복이 생략된 합성보의 구조설계지침 제정을 위한 고찰)

  • Hong, Won-Kee;Kim, Jin-Min;Lee, Kyoung-Hun;Park, Seon-Chee;Kim, Jeom-Han
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.93-98
    • /
    • 2008
  • As high rise buildings and large span spatial structures are constructed, new composite members and construction techniques are continuously developed. Wide flange steel beam can be easily constructed but the fire proofing protection is necessary and the cost is high. Nowadays environmental pollution of structures is becoming a big issue. The material of fire proofing protection is not allowed to use for structural members in several countries because it cab be a cause of environment pollution. Composite beam is a new hybrid beam system which is not needed a fire proofing protection process. Composite beam has better construction capacity than that of RC system and has more economic advantages than that of wide flange steel beam. In this paper, structural design guide lines of composite beam were provided to apply design and construction.

A Study on Fire and Explosion Accident Cause in Regenerated Thermal Oxidizer (축열식 소각로의 화재.폭발 사고원인 규명 연구)

  • Lee, Keun-Won;Ma, Byung-Chol;Hwang, Soon-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.7-11
    • /
    • 2007
  • There has been a report of fire and explosion accident in regenerated thermal oxidizer (RTO). This paper was to investigate accident causes of RTO in the resin re-treatment process. The experiments carried out physicochemical properties and thermal stability analyses by using flash point tester, flammable range apparatus, autoignition tester, GC/MSD and thermal screening unit. We inferred causes of fire and explosion from the regenerated thermal oxidizer to prevent an accident of its process.

  • PDF

A Study on the Design of Microcomputer Processor Algorithm for Electrical Fire Prediction (전기화재 예측을 위한 마이컴 프로세서 알고리즘 설계에 관한 연구)

  • Kwak, Dong-kurl;Choi, Jung-Kyu;Lee, Bong-Seob;Choi, Shin-Hyeong
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.11-12
    • /
    • 2015
  • This study has looked into ways to cut the power supply by predicting electrical fire that may occur in low-voltage cable, which is most frequently used in industrial settings and households. In addition, we have designed a system that cuts off electricity to prevent the fire upon occurrence of events that may cause electrical fire, including short circuit, tracking and contact failure. A lot of previous researches have designed arc suppressors built in analog circuit, which left much to be desired such as difficulty in remote control and inability to identify the location of arc suppressor when it is activated. To address these issues, the study seeks to develop an arc suppressor using micom and to verify its performance through simulations designed to detect arc faults.

  • PDF

Fire Prevention Systems for Photovoltaic Connection Panel (태양광 접속반의 화재 방지 시스템)

  • Han, Man Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.137-138
    • /
    • 2019
  • The photovoltaic module connects the voltage generated by the solar cell to the inverter. In the photovoltaic module, a diode is used to block the reverse voltage from the inverter to the solar cell. The heat generation of this diode is the main cause of the solar connection fire. In this paper, we propose a method to monitor the heat generation of diodes and prevent fire by using IoT devices.

  • PDF

Study of Structural Stability for H-section Beams Made of Fire Resistant Steels (FR 490) at High Temperatures by Analytical Method (건축용 내화강재(FR 490) 적용 H형강 보부재의 고온내력 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.52-57
    • /
    • 2014
  • When structural elements of steel framed structures are exposed to fire situations, the structural stability begins to decrease due to dislocation of substantial. The increase of the beam length causes an additional stress and deflection. These can be serious factors to cause a severe failure of structures. To improve the fire resistance of beams, prevention of the heat from a fire by coating with fire protection material is essential for beams. The FR 490 was developed to enhance fire resistance compared with SM 490 steel. However, the fire resistance of FR 490 H-beams has not been evaluated by analysis method since it was developed. In this paper, materials properties in high temperature and a heat transfer and thermal stress theory were used in the evaluation of the fire resistance of FR490 H-beams. The fire resistance of FR490 steel beams was compared with that of SM490 beams. The comparison verified that the structural stability of FR490 beams at high temperature was superior to that of SM490 beams.

Research and Analysis of the Causes and Preventive Measures of Fires Caused by a Disposable Gas Lighter (1회용 가스라이터로 인한 화재 원인과 예방대책의 조사·분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • This study analyzed the regulatory actions of disposal gas lighters as well as the situations, causes, and preventive measures of fires, and accidents caused by disposal gas lighters. Since child-resistant lighters became mandatory, the percentage of fires caused by playing with fire has decreased in Korea as it did in America and Japan. Fires caused by disposal gas lighters can occur by afterburning, unintentional lighting, large flames, or explosion or bursting as well as by arson and playing with fire. This study suggests the preventive measures of fires caused by disposal gas lighters as follows: Taking a step not to be used as child's tool for playing with fire, the warning of fire cases caused by afterburning, warning of the dangers of leaving disposal gas lighters on the car dashboard or high temperature places, improving the protective synthetic resin cover of the stop part of a vehicle seat rail, and providing information on precautions for keeping in drawers or disposition methods.

A Study on the Establishment of the Framework Apportion Ratio in Calculating Damages due to Accidental Fires (화재의 실화배상책임액 산정을 위한 프레임워크 수립에 관한 연구)

  • Song, Kwang-Suk;Park, Chung-Hwa
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.190-203
    • /
    • 2019
  • Since the amendment of the Accidental Fire Liability Act in 2009, interested parties in accidental fire liability contracts have settled issues associated with the estimation of each other's liability amounts through lawsuits. As fire accidents are complex in nature, it is difficult to distinguish between direct and additional damages caused by extended combustion while calculating liability amounts for accidental fires. Additionally, there is an increasing need for establishing and using a framework that includes validity and reliability. To establish such a framework for estimating the liability amounts in case of an accidental fire, this study suggests a novel categorization of fires to be applied to the framework. This will be organized by the subjects of the liability of accidental fires, and quantified and probabilistic processed qualitative items through the methods applied to quantification (AMEA/FTA) based on the fire statistics data published by the government and the previous researchers' research application data and results.