• Title/Summary/Keyword: Cause of fire

Search Result 819, Processing Time 0.031 seconds

Study on the strengthening of community safety Network through volunteer fire department training program reengineering (의용소방대 교육프로그램 재설계를 통한 지역사회 안전 Network기능 강화 방안에 관한 연구)

  • Park, Chan-Seok;Oh, Taek-Hum;Yoon, Myoung-Oh
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.21-30
    • /
    • 2013
  • Korean Volunteer Fire Departments are the representative disaster-related civilian organizations which are based on "Firefighting Framework Act Article 37"and ordinance for complementing the lack of fire-fighting personnel and volunteer and they play a part as community safety keepers. They are operated by the National funding, but cannot be defined as the organization in governmental sources completely or pure volunteer organization in terms of its founding purpose and activities. In these special characteristics, some Volunteer Fire Departments play an important role in Civilian Volunteer Disaster Prevention by being managed effectively, but the others do not. There can be many cause-analyses about this difference. They aren't profit-making organizations and are groups which have no compulsion. So it is important that who the leader is, and what type of leadership he has. By solving this bias by considering these characteristics, in this study we make them perform the center role of community safety network through analyzing the existing status and problems of volunteer fire department education and customized training program reengineering to meet class-specific and regional level.

A bibliographic Study about comparison of Eastern-Western medicine on impotence (양위(陽?)에 대한 동서의학적(東西醫學的) 고찰(考察))

  • Kim, Hyeong-Gyun;Kim, Seong-Jae
    • The Journal of Korean Medicine
    • /
    • v.17 no.2 s.32
    • /
    • pp.88-99
    • /
    • 1996
  • Impotence is defined as a consistent inability to achieve or maintain penile erection that is adequate for completion of sexual intercourse. In oriental midicine, the chief cause of impotence is the decline of the fire from the gate of life, and in western medicine that is psycogenic and organic. Because of the increase aging people and psycologic stress that modern people get, impotence became common. This bibliographic study on impotence in the oriental and western medicine books has come to the following conclusions. 1. The main cause of impotence in the oriental medicine is the decline of the fire from the gate of life(命門火衰), followed by the deficiency of both heart and spleen(心脾兩虛), the depression of Liver energy(肝氣鬱結), and attack of blended wetness and heat to the lower wanner(濕熱下注). 2. The theraphics of impotence in oriental medicine are warming and strenghthening Kidney. softness of Liver energy, tonifying the Kidney to relieve mental strain, clear away the wetness-heat, and infairment of Heart and Spleen. 3. The prescriptions of impotence are Yugyeyum, Gyibitang, Soyosan, Sunjitang, and Yongdamsagantang. 4. In the western medicine, psycotherapy, medical therapy and surgical therapy are the major way to treat impotence.

  • PDF

Safety Analysis of Hazmat Tank Foundation to Prevent Tank Fire (위험물탱크 화재방지를 위한 기초 안정성 분석연구)

  • Choi, Jeong-Soo;Lim, Jong-Jin;Choi, Young-Seok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.165-172
    • /
    • 2008
  • Leakage incidents due to the fault of hazmat tank foundations are likely to cause the tremendous fire disaster in the national industry cluster area. The proper design and construction of tank foundation should be required to prevent the tank fire. In the study, the types of typical tank foundations were classified and modeling the individual tank type for 3D FEM analysis was performed to suggest the guideline for the design and construction of tank foundations. Matters to be attended of the foundation design and construction are reviewed through the comparison assessment of the numerical analysis results of the foundation types.

  • PDF

Fire Cause Analysis on Electric Pad Due to Defect of Hot Wires (전기장판 열선 결함에 의한 전기화재 원인분석)

  • Song, J.Y.;Sa, S.H.;Nam, J.W.;Kim, J.P.;Cho, Y.J.;Oh, B.Y.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.2
    • /
    • pp.7-12
    • /
    • 2012
  • This paper describes electrical fire on electric pad caused by defect of hot wires. We analyzed two type electric pad using by carbon type hot wire and magnetic shielded type hot wire. First, a carbon type hot wires electric pad is virtually impossible to connect hot wire as a method of electrical welding or soldering. In order to connect between hot wires, that has to splice carbon type material connector. If junction of hot wires was occurrence of poor connection on electric pad, it increase contact resistance on this junction point. With increasing contact resistance, junction of hot wires on electric pad generates local heating and finally leads to electrical fire. An electric pad using by a magnetic shielded type hot wire happened local heating on signal wire for sensing temperature-rise caused by applying current for magnetic shielded. With increasing local heating of signal wire, insulated coating of hot wire was melted. Finally the magnetic shielded type hot wire electric pad lead to electrical fire with breakdown between signal wire and hot wire. In this paper, we analyzed shape of damage in hot wire caused by electrical local heating and investigated fire cause on electric pad due to defect of hot wires.

A Study on the Fire Risk of ESS through Fire Status and Field Investigation (화재현황 및 현장조사를 통한 ESS의 화재 위험성 연구)

  • Park, Kwang-Muk;Kim, Jae-Hyun;Park, Jin-Yeong;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.91-99
    • /
    • 2018
  • Recently, the spread of ESS in Korea has increased and a fire accident has also occurred. By July 2018, there were a total of 7 cases. All 7 cases were ESS systems consisting of lithium-ion batteries and were burned down. Both the automatic fire extinguisher and the fire department were not able to digest. In this paper, the characteristics of ESS fire are analyzed based on recent ESS fire situation and field investigation, and the cause of fire is divided into environmental, electrical and thermal factors. As a result, it was found that the ESS fire was correlated with the installation environment of the system. In the domestic and overseas lithium ion battery test standard and ESS facility standard survey, the trends and differences of domestic and overseas facilities standards were identified. Based on the fire status and field investigationy, and domestic and overseas facility standard survey, measures were suggested to prevent and prevent the spread of fire in ESS fire.

Study on the effective response method to reduce combustible metal fire (금속화재 위험감소 방안에 관한 이론적 연구)

  • Nam, Ki-Hun;Lee, Jun-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.600-606
    • /
    • 2018
  • A class D fire or combustible metal fire is characterized by the presence of burning metals. Only certain metals or metal compounds are flammable, including sodium and lithium. General fire extinguishing agents, such as dry chemical powder, water-based fire extinguish agents, and carbon dioxide, cannot be used in class D fires. This is because these agents cause adverse reactions or are ineffective. In addition, the amount of usage of combustible metals is increasing due to continuous development of the semiconductor and fuel cell industries. Despite this, Korea does not have standards and laws related to combustible metal fires. This paper suggests directions of the class D fire management policies to reduce the class D fire risk and impact by analyzing the standards and laws related to class D fires and combustible metal fire cases. The factors to make laws on class D fire prevention and response systems, and management system of dry sand were determined. These results may be used to help reduce the risk of class D fires and improve the response abilities.

Examination of the Cause of Damage to Capacitors for Home Appliances and Analysis of the Heat Generation Mechanism (가전용 커패시터의 소손원인 규명 및 발열 메커니즘 해석)

  • Park, Hyung-Ki;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.13-19
    • /
    • 2011
  • The purpose of this study is to examine the cause of damage to electrolytic capacitors and to present the heat generation mechanism in order to prevent the occurrence of similar problems. From the analysis results of electrolytic capacitors collected from accident sites, the fire causing area can be limited to the primary power supply for the initial accident. From the tests performed by applying overvoltage, surge, etc., it is thought that the fuse, varistor, etc., are not directly related to the accidents that occurred. The analysis of the characteristics using a switching regulator showed that the charge and discharge characteristics fell short of standard values. In addition, it is thought that heated electrolytic capacitors caused thermal stress to nearby resistances, elements, etc. It can be seen that the heat generation is governed by the over-ripple current, application of AC overvoltage, surge input, internal temperature increase, defective airtightness, etc. Therefore, when designing an electrolytic capacitor, it is necessary to comprehensively consider the correct polarity arrangement, appropriate voltage application, correct connection of equivalent series resistance(ESR) and equivalent series inductance(SEL), rapid charge and discharge control, sufficient margin of dielectric tangent, etc.

Analysis of Thermal Characteristics for the Fire Risk Assessment According to Partial Disconnection on the VCTF and IV Electric Wire (VCTF와 IV전선의 반단선에 의한 화재위험성 평가를 위한 열적특성 해석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Park, Jong-Young;Park, Young-Ho;Lee, Hyung-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.47-52
    • /
    • 2008
  • Many researches on fire risk for normal electric wiring have been pursued in advanced countries such as the USA and Japan, but comparative studies of the partial disconnection and normal state of electric wires have not been conducted. Detection system for the cause of partial disconnection is not developed and prevention countermeasure for electrical fire by the cause is not effective. Therefore, in this paper, partial disconnection characteristics on electric wires were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF(PVC insulated PVC sheathed Cap Tyre Flexible Cord, KS C 3304) and IV(lndoorwire PVC, KS C 3302). VCTF is used in wiring portable electric appliances and the IV is used indoors. Interrelationships between partial disconnection premonitory symptom and current were derived and analyzed by the characteristics based on experiments and thermal analysis for electric wire according to current under normal state and 200% overload state of rated current.

A Study on the Judgment of Fire Cause of Ballast for Fluorescent Lamp (형광등용 안정기의 화재원인 판정에 관한 연구)

  • 최충석;백동현
    • Fire Science and Engineering
    • /
    • v.14 no.3
    • /
    • pp.1-5
    • /
    • 2000
  • In this paper, we analyzed the fire hazard of the ballast for fluorescent lamp used as the indoor lighting. In the result of being analyzed the ballast wire by stereo microscope, many melting points were discovered, it was impossible to judge a cause with the naked eye. In the Thermal-deteriorated ballast wire, elongation structure disappeared at above $700^{\circ}$, and it only showed the enlarged appearance of the copper particle. On the metallurgical microscope of short wire, as it was confirmed the regulation of the columnar structure and the void growth at the center of boundary-face, we found that electrical short-circuit generated. Also, it was confirmed the melted part on the analysis using SEM(scanning electron microscope). Not only CuL and Cuk line that is composition factor of copper but also OK line was observed uniformly on the spectra analysis using EDX(energy dispersive x-ray spectroscopy). It means that oxygen took part in reaction at the recombination process.

  • PDF

Analysis of Actual State of Motor Vehicle Fires in Korea (자동차화재 실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.47-59
    • /
    • 2011
  • The actual state of motor vehicle fires was analyzed based on Annual Report on Fire Statistics and National Fire Data System and as a result, the followings were obtained. Motor vehicle fires occur over 16 cases every day with over 0.5 casualties and direct property loss of 50 million won. Most motor vehicle fires are caused by mechanical reasons, followed by electrical factors and arson. Arson accounts for 7.39% of all fires but 13.79% of all motor vehicle fires. Yearly fatalities and casualties per 100 motor vehicle fires were 0.9 and 2.4 on the average, respectively. Although fires which occur in the expressway account for 12.55% of all motor vehicle fires, fatalities, casualties, and property loss caused by motor vehicle fires in the expressway were 16.12%, 21.05%, and 20.65%, respectively.