• 제목/요약/키워드: Cathodic Protection(CP)

검색결과 38건 처리시간 0.022초

무선 원격 부식모니터링용 TRS 단말기 (The TRS Terminal for Wireless Remote Corrosion Monitoring System)

  • 하태현;배정효;이현구;하윤철;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.544-547
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in odor to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. They need remote automatic corrosion monitoring system for easy maintenance. In this paper, The communication method was studied mainly. And the specifications of proposed TRS (Truncked Radio System ) terminal for corrosion monitoring are introduced briefly.

  • PDF

상수도 배관용 무선 원격 부식모니터링 시스템 (The Remote Wireless Corrosion Monitoring System for Water Pipeline)

  • 하태현;배정효;이현구;하윤철;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.637-640
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in oder to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. In this paper, results of development about remote wireless corrosion monitoring system for water pipe line are presented briefly.

  • PDF

딥러닝을 활용한 도시가스배관의 전기방식(Cathodic Protection) 정류기 제어에 관한 연구 (A Study on Cathodic Protection Rectifier Control of City Gas Pipes using Deep Learning)

  • 이형민;임근택;조규선
    • 한국가스학회지
    • /
    • 제27권2호
    • /
    • pp.49-56
    • /
    • 2023
  • 4차 산업혁명으로 인공지능(AI, Artificial Intelligence) 관련 기술이 고도로 성장함에 따라 여러 분야에서 AI를 접목하는 사례가 증가하고 있다. 주요 원인은 정보통신기술이 발달됨에 따라 기하급수적으로 증가하는 데이터를 사람이 직접 처리·분석하는데 현실적인 한계가 있고, 새로운 기술을 적용하여 휴먼 에러에 대한 리스크도 감소시킬 수 있기 때문이다. 이번 연구에서는 '원격 전위 측정용터미널(T/B, Test Box)'로부터 수신된 데이터와 해당시점의 '원격 정류기' 출력을 수집 후, AI가 학습하도록 하였다. AI의 학습 데이터는 최초 수집된 데이터의 회기분석을 통한 데이터 전처리로 확보하였고, 학습모델은 심층 강화학습(DRL, Deep Reinforce-ment Learning) 알고리즘 중(中) Value기반의 Q-Learning모델이 적용하였다. 데이터 학습이 완료된 AI는 실제 도시가스 공급지역에 투입하여, 수신된 원격T/B 데이터를 기반으로 AI가 적절하게 대응하는지 검증하고, 이를 통해 향후 AI가 전기방식 관리에 적합한 수단으로 활용될 수 있는지 검증하고자 한다.

A Study on the Coatings for CP System in the Environment in which Thin Layer of Extremely Acidic Fluids are Formed

  • Chang, H.Y.;So, I.S.;Jin, T.F.;Kim, Y.S.;Yoo, Y.R.;Kang, M.S.
    • Corrosion Science and Technology
    • /
    • 제5권1호
    • /
    • pp.5-14
    • /
    • 2006
  • A lot of parts in FGD (Flue Gas Desulphurization) systems of fossil-fuel power plants show the environments in which are highly changeable and extremely acidic corrosive medium according to time and locations, e.g. in duct works, coolers and re-heaters etc.. These conditions are formed when system materials are immersed in fluid that flows on them or when exhausted gas is condensed into thin layered medium to contact materials of the system walls and roofs. The environments make troublesome corrosion and air pollution problems that are occurred from the leakage of the condensed solution. The frequent shut-down and repairing works of FGD systems also demand costs and low efficiencies of those facilities. In general, high corrosion resistant materials have been used to solve this problem. However, even the super alloys and Teflon linings sometimes have not been good enough to preventing corrosion. Further more, they are expensive and not easily repairable in short periods of operation stops. In this work, new technology that is effective, economical and easily repairable has proposed to solve the corrosion problems in FGD facilities. This technology contains cathodic protection, coatings and remote monitoring-controlling systems.

3D FEM 모델링을 이용한 원전 매설배관의 방식성능 평가 및 결함탐지능 분석 (Evaluation of Corrosion Protection Efficiency and Analysis of Damage Detectability in Buried Pipes of a Nuclear Power Plant with 3D FEM)

  • 장현영;박흥배;김기태;김영식;장윤영
    • 한국압력기기공학회 논문집
    • /
    • 제11권2호
    • /
    • pp.61-67
    • /
    • 2015
  • 3D FEM modeling based on 3D CAD data has been performed to evaluate the efficiency of CP system in a real operating nuclear power plant. The results of it successfully produced sophisticated profiles of electrolytic potential and current distributions in the soil of an interested area. This technology is expected to be a breakthrough for detection technology of damages on buried pipes when it comes into combining with a brand of area potential earth current (APEC) and ground penetrated radar (GPR) technologies. 2D current distribution and 2D current vectors on the earth surface from the APEC survey will be used as boundary conditions with exact 3D geometry data resulting in visualization of locations and extents of corrosion damages on the buried pipes in nuclear power plants.

Corrosion Monitoring for Protected Systems using Thin-Film Electrical Resistance (TFER) Sensor

  • Lee, Seong-Min;Li, SeonYeob;Jung, Sung-Won;Kim, YoungGeun;Song, HongSeok;Won, Deok-Soo
    • Corrosion Science and Technology
    • /
    • 제5권3호
    • /
    • pp.112-116
    • /
    • 2006
  • This study has been conducted to monitor the corrosion rate of cathodically protected structure and corrosion inhibited system using multi-line thin-film electrical resistance (TFER) sensor in various environments. The field test data of TFER sensor for the corrosion monitoring of cathodically protected underground pipeline in soil environments and of corrosion inhibited gas heaters were also presented. The sensor was found to be a powerful method to commit the sensitive pick-up of small corrosion rate which can be observed in the cathodically protected and corrosion inhibited systems.

차량을 이용한 원격전위 측정방법 개발에 관한 연구 (A Study on the Development of Remotely CP Potential Measuring Method by using Vehicle)

  • 류영돈;조영도;김진준;서민성
    • 한국가스학회지
    • /
    • 제20권5호
    • /
    • pp.64-71
    • /
    • 2016
  • 도시가스사업법령에 따라 지하에 매설된 도시가스 배관에는 전기부식 방지조치를 하도록 하고 있으며, 테스트 박스에서 배관의 방식전위를 1년마다 측정하도록 하고 있다. 그런데, 도심에 설치된 테스트 박스(T/B)의 경우 대부분 차량이 통행하는 도로위에 설치되어 있어 전위를 측정할 때 어려움이 있다. 즉, 전위를 측정하기 위해서는 차량을 통제하거나, 교통량이 적은 심야에 실시해야 하는 등 어려움이 있다. 본 연구에서는 이러한 방식전위 측정의 문제점을 해결하기 위하여 차량을 타고 이동하면서 테스트박스의 전위를 측정하는 방법을 연구하였다. 도로위에 설치된 테스트박스 하부에 기준전극과 데이터로거를 설치하고, 차량이 이동하면서 데이터로거로부터 방식 전위를 수신하는 방법으로 시험 연구를 진행하였다. 테스트 박스가 도로위에 설치되어 있어 전파를 송수신하는 데 어려움이 있어 안테나 방식을 변경해 가면서 가장 효과적인 방법을 채택하기로 하였다. 개발한 방법을 도시가스사의 실제 테스트박스에 적용한 결과 이 방법은 기존의 측정방법보다 20배 이상 시간을 절약할 수 있었다.

혐기성 토양에 서식하는 황산염환원세균에 의한 가스배관의 미생물부식 (CORROSION OF STEEL GAS PIPELINE INDUCED BY SULFATE-REDUCING BACTERIA IN ANAEROBIC SOIL)

  • 이선엽;전경수;고영태;강탁
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 2001년도 추계학술발표회 논문집
    • /
    • pp.58-68
    • /
    • 2001
  • Microbiologically influenced corrosion (MIC) of carbon steel gas pipeline in soil environments was investigated at field and laboratory MIC is very severe corrosion and it is not easy to distinguish this corrosion from Inorganic corrosion because of its localized, pitting-type character Therefore, it is important to provide proper assessment techniques for the prediction, detection, monitoring and mitigation of MIC. It is possible to predict the MIC risk, i.e., the activity of sulfate-reducing bacteria (SRB) through the analysis of soil environments. Chemical, microbiological and surface analysis of corrosion products and metal attacked could reveal the possibility of the occurrence of MIC. Various electrochemical and surface analysis techniques could be used for the study of MIC. Among these techniques, thin-film electrical resistance (ER) type sensors are promising to obtain localized corrosion rate of MIC induced by SRB. It is also important to study the effect of cathodic protection (CP) on the MIC In case of coated pipeline, the relationship between coating disbondment and the activity of SRB beneath the disbanded coating is also important.

  • PDF