• Title/Summary/Keyword: Cathodic Polarization

Search Result 148, Processing Time 0.023 seconds

Evaluation on Damage Behavior of Al-4.5%Mg-0.6%Mn Al Alloy with Potentiostatic Experiment Time (Al-4.5%Mg-0.6%Mn 알루미늄 합금의 정전위 시간 변수에 따른 손상거동 평가)

  • Kim, Seong-Jong;Woo, Yong-Bin;Han, Min-Su;Jang, Seok-Ki
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.6
    • /
    • pp.569-576
    • /
    • 2012
  • In general, aluminum alloys forms the passive film($Al_2O_3$, $Al_2O_3{\cdot}3H_2O$) in neutral solution. However, the passive film created on the surface will be destroyed by chloride ions contained in sea water so the corrosion will occur. In this study, in order to solve the problem of corrosion under a seawater environment, potentiostatic protection techniques were applied to Al-4.5%Mg-0.6%Mn aluminum alloy in seawater. At polarization experiments, active state were observed at anodic polarization and concentration polarization by reduction of dissolves oxygen and activation polarization were found at anodic polarization. As a results of potentiostatic experiment, calcareous deposit were created much more as applying time increase from the turning point of the concentration polarization and activation polarization and crevice corrosion was partially observed between calcareous deposit and surface of base metal. Overall potentiostatic anodic polarization experiment was difficult to apply potentiostatic corrosion protection technology by occurrence of active state, whereas potentiostatic cathodic polarization experiment examined optimum corrosion protection condition of -1.1 V~-0.75 V within the range of concentration polarization considered various applying time.

The Study on the Corrosion Characteristics of Cr Plating in Marine Environment (해양환경 중에서 Cr도금의 부식 특성에 관한 연구)

  • 임우조;곽남인;윤병두
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.211-217
    • /
    • 2003
  • Recently, with rapid development in marine and shipbuilding industries such as marine structures, ships and chemical plants for ship, there occurs much interest in the study on corrosion characteristics played an important role in mechanical design. This paper was studies on the corrosion characteristics of chromium plating in the marine environment. Under the various specific resistance, the electrochemical polarization test of chromium plating was carried out. And thus corrosion potential, polarization resistance, corrosion current density, control efficiency of corrosion and polarization control behavior of chromium plating are investigated. The main results are as the followed : 1. The polarization resistance of Cr plating and Ni become higher than that of base metal, also and these material become low with decrease of the specific resistance. 2. As the specific resistance decreases, the corrosion current density of Cr and Ni plating is lower than that of base metal. 3. The corrosion reaction of Cr plating, Ni plating and base metal vs. specific resistance is cathodic control.

The Study on the Electrochemical Polarization Characteristics of Hydrogen Embrittlement for Ferrite Stainless Steel with Welding Conditions (용접조건에 따른 페라이트 스테인리스강에 대한 수소취성의 전기화학적 분극특성에 관한 연구)

  • Choi, Byung-Il;Lim, Uh-Joh
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.4 s.29
    • /
    • pp.30-35
    • /
    • 2005
  • In order to examine the electrochemical polarization characteristics of hydrogen embrittlement far STS444 with welding conditions, this paper carried out the accelerated hydrogen osmosis test and the electrochemical polarization test. That is, in $0.5M\; H_2SO_4+0.001M\;As_2O_3$ solution, the hydrogen embrittlement behavior of STS444 added to load of $1,400kg/cm^2$ together with hydrogen osmosis by current of $30mA/cm^2$ far 60 min. was considered. In researching the electrochemical polarization characteristics of hydrogen embrittlement for STS444 with welding conditions, the previous study clarified that tensile strength or elongation became low influenced by absorption of oil or water before welding. In this paper, we proposed the advanced mechanism of hydrogen embrittlement that integrated electrochemical corrosion with the existing mechanism of hydrogen embrirtlement.

  • PDF

Electrochemical Activity of a Blue Anatase TiO2 Nanotube Array for the Oxygen Evolution Reaction in Alkaline Water Electrolysis

  • Han, Junhyeok;Choi, Hyejin;Lee, Gibaek;Tak, Yongsug;Yoon, Jeyong
    • Journal of Electrochemical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.76-81
    • /
    • 2016
  • An anatase TiO2 nanotube array (NTA) was fabricated by anodization and successive heat treatments. When the anatase TiO2 NTA was cathodically polarized, its color changed to blue, and it could be used as an electrochemically active anode for an oxygen evolution reaction (OER) in alkaline water electrolysis. The structure of the blue anatase TiO2 NTA was controlled by the anodization conditions and its catalytic activity increased with an increase of the surface area. The activity of the blue anatase TiO2 NTA gradually reduced with the continued OER because of the partial oxidation of Ti3+ to Ti4+. However, an intermittent cathodic regeneration process could significantly slow its reduction rate. The blue anatase TiO2 NTA could be an alternative anode for alkaline water electrolysis.

Oxygen Reduction Mechanism and Electrode Properties of (La,Sr)$MnO_3$-YSZ Composite Cathode for Solid Oxide Fuel Cell (Part II: Electrode Properties) (고체산화물 연료전지용 (La,Sr)$MnO_3$-YSZ 복합체 양극의 산소환원 반응기구 및 전극 특성 (Part II: 전극 특성))

  • 김재동;김구대;이기태
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.1
    • /
    • pp.93-99
    • /
    • 2001
  • (La,Sr)MnO$_3$(LSM)-YSZ 복합체 양극에 있어서 소결온도 및 전극두께와 cathodic potential이 전극 특성에 미치는 영향을 고찰하였다. 양극의 소결은 삼상계면의 양을 결정하는 중요한 변수로 LSM 단미 양극과 YSZ가 40 wt% 포함된 LSM-YSZ 복합체 양극 모두 120$0^{\circ}C$에 소결했을 때 가장 낮은 분극저항을 나타내었다. 또한 양극 후막의 두께가 얇아지면 양극의 in-plane 저항이 증가하여 ohmic 저항이 증가하였는데, LSM-YSZ 복합체 양극의 경우 약 30$mu extrm{m}$ 정도의 전극두께가 가장 효과적인 전극 특성을 나타내었다. 한편, LSM-YSZ 복합체 양극에 -0.5 V의 cathodic potential을 인가함에 따라 양극에서 일어나는 산소환원반응의 활성이 증가하였는데, 1가 산소이온의 표면확산반응의 분극저항은 감소하였으나, 고주파수 영역에서 나타나는 산소이온전달반응의 저항은 거의 변화하지 않았다. 이것은 Mn의 환원에 의한 양극표면에 생성된 산소공공에 기인한다.

  • PDF

Cathodic Polarization Measurements on La0.9Sr0.1MnO3 Electrode for Solid Oxide Fuel Cells

  • Lee, H.Y.;Oh, S.M.
    • Applied Chemistry for Engineering
    • /
    • v.4 no.1
    • /
    • pp.153-161
    • /
    • 1993
  • Cathodic oxygen reduction kinetics on $La_{0.9}Sr_{0.1}MnO_3$ electrode have been examined at $700-900^{\circ}C$ under various oxygen partial pressures. AC impedance and current interruption techniques were employed for the determination of charge transfer resistances for electrochemical oxygen reduction. The $R_{ct}$ values obtained from two different methods were very close each other for $La_{0.9}Sr_{0.1}MnO_3$ electrode. Activation energy for the electrochemical oxygen reduction was found to be 174kJ/mol under atmospheric oxygen pressure. $R_{ct}$ measurements as a function of oxygen partial pressure indicate that the rate-determining step for the electrochemical oxygen reduction on $La_{0.9}Sr_{0.1}MnO_3$ electrode is the charge transfer process.

  • PDF

Electrochemical Characteristics of Arc Zn Thermal Spray Coating Layer in Sea Water (해수 내 아크 아연 용사코팅 층의 전기화학적 특성)

  • Park, Il-Cho;Seo, Gwang-Cheol;Lee, Gyeong-Woo;Kim, Seong-Jong
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.6
    • /
    • pp.343-348
    • /
    • 2015
  • In this paper, arc Zn thermal spray coating was carried out on the SS400 steel, and then various electrochemical characteristics and surface damage behavior of Zn thermal spray coating layer were analyzed. As the results, the potential of Zn thermal spray coating layer presented driving voltage above 300 mV compare to that of SS400 steel. The passivity characteristic in anodic polarization curve was not presented. It was adequate to as sacrificial anode material. In the surface damage after galvanostatic experiments, uniform corrosion tendency of Zn thermal spray coating layer was clearly observed with acceleration of the dissolution reaction. In conclusion, Zn thermal spray coating could be determined to represent the corrosion protection effect by stable sacrificial anodic cathodic protection method in seawater because it had sufficient driving voltage and uniform corrosion damage tendency for the SS400 steel.

Cathodic Reduction of Dichromate Ion (중크롬산이온의 음극 환원반응)

  • Lee Ju-Seong
    • Journal of the Korean Chemical Society
    • /
    • v.21 no.4
    • /
    • pp.276-283
    • /
    • 1977
  • Reduction of dichromate at a platinum cathode in acid solution was studied by cyclic voltammetry and controlled potential electrolysis. Cathodic polarization curve consisted of three waves in unbuffered solution of potassium dichromate having initial pH ranges 1.5∼4.0, with sodium sulfate as the supporting electrolyte. Relative heights of the first and the second waves were, respectively, a function of chromium (Ⅵ) concentration and activity of hydrogen ion, but that of the third wave was not proportional to both of them. The current of the first two peaks were proportional to the sweep rate of potential (${\nu}$), while that of the last peak vs. ${\nu}^{1/2}$ was linear at the sweep rate of less than 50mV/sec. By the controlled potential electrolysis, the reduction of chromium (Ⅵ) was almost completely suppressed at potentials more negative than the last peak and at initial pH's above ca. 2.3 of unbuffered solution. Therefore, these peaks represented, respectively, $Cr_2O_7^{2-}{\to}Cr^{3+},\;2H^+{\to}H_2$ and the formation of a cathodic film.

  • PDF

Investigation on the Effects of Hydrogen Charging on Oxidation Behavior of Ultrahigh-Strength Automotive Steels (초고강도 자동차용 강의 환원정전류인가에 따른 산화 거동 변화 연구)

  • Ha, Heon-Young;Kim, Hye-Jin;Moon, Joonoh;Lee, Tae-Ho;Jo, Hyo-Haeng;Lee, Chang-Geun;Yoo, Byung-Kil;Yang, Won-Seog
    • Corrosion Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.317-327
    • /
    • 2017
  • The change in the oxidation behavior of three types of B-added ultrahigh strength martensitic steels containing Ti and Nb induced by applying constant cathodic current was investigated. In a 3% NaCl+0.3% $NH_4SCN$ solution, the overall polarization behavior of the three alloys was similar, and degradation of the oxide film was observed in the three alloys after applying constant cathodic current. A significant increase in the anodic current density was observed in the Nb-added alloy, while it was diminished in the Ti-added alloy. Both Ti and Nb alloying decreased the hydrogen overpotential by forming NbC and TiC particles. In addition, the thickest oxide film was formed on the Ti-added alloy, but the addition of Nb decreased the film thickness. Therefore, it was concluded that the remarkable increase in the anodic current density of Nb-added alloy induced by applying constant cathodic current density was attributed to the formation of the thinnest oxide film less protective to hydrogen absorption, and the addition of Ti effectively blocked the hydrogen absorption by forming TiC particles and a relatively thick oxide film.

Formation of Calcareous Deposit on Steel Plate by using Waste Oyster Shell (강판상에 굴 패각을 이용한 탄산칼슘 피막의 형성)

  • Kim, Beomsoo;Kwon, Jaesung;Kim, Yeonwon;Lee, Myeonghoon;Yang, Jeonghyeon
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.6
    • /
    • pp.531-535
    • /
    • 2017
  • Enormous amount of waste oyster-shell (OS) has a major disposal problem in coastal regions. OSs have attracted much attention for recycling, because these are mainly composed of calcium carbonate with rare impurities. In this study, we demonstrate the calcareous deposit films on steel plate by using OSs on the basic of cathodic protection technique. The composition of the OSs was analyzed by wavelength dispersive X-ray fluorescence spectrometer. Carbon dioxide gas was pumped into distilled water to make carbonic acid solution for dissolution of OS. The calcareous deposit was characterized by second electron microscope (SEM), energy dispersive X-ray analysis (EDX) and X-ray diffraction. Corrosion rates were estimated by measurements of anodic polarization and immersion test. It is confirmed that calcareous deposits on steel plate are formed under all condition of cathodic protection by using waste OS from the SEM and EDX results. Calcareous deposits on steel by OS provide good corrosion resistance by acting as a barrier to oxygen supply to the steel surface.