• 제목/요약/키워드: Cathode Power

검색결과 544건 처리시간 0.026초

5kW 용융탄산염 연료전지(MCFC) 이젝터 설계 및 시험 (The Ejector Design and Test for 5kW MCFC System)

  • 김범주;김도형;이정현;이성윤;김진열;강승원;임희천
    • 한국수소및신에너지학회논문집
    • /
    • 제20권1호
    • /
    • pp.31-37
    • /
    • 2009
  • An ejector is a machine utilized for mixing fluid, maintaining a vacuum, and transporting fluid. The Ejector enhances system efficiency, are easily operated, have a mechnically simple structure, and do not require a power supply. Because of these advantages, the ejector has been applied to a variety of industrial fields such as refrigerators, power plants and oil plants. In this work, an ejector was used to safely recycle anode tail gas in a 5 kW Molten Carbonate Fuel Cell system at KEPRI(Korea Electric Power Research Institute). In this system, the ejector is placed at mixing point between the anode tail gas and the cathode tail gas or the fresh air. Commercial ejectors are not designed for the actual operating conditions for our fuel cell system. A new ejector was therefore designed for use beyond conventional operating limits. In this study, the entrainment ratio is measured according to the diametrical ratio of nozzle to throat in the designed ejector. This helps to define important criteria of ejectors for MCFC recycling.

Integrated Thyristor Switch Structures for Capacitor Discharge Application

  • 김은동;장창리;김상철;백도현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 반도체재료
    • /
    • pp.22-25
    • /
    • 2001
  • A thyristor switch circuit for capacitor discharge application, of which the equivalent circuit includes a resistor between cathode and gate of a reverse-conducting thyristor and an avalanche diode anti-parallel between its anode and gate to set thyristor tum-on voltage, is monolithically integrated by planar process with AVE double-implantation method. To ensure a lower breakdown voltage of the avalanche diode for thyristor tum-on than the break-over voltage of the thyristor, $p^+$ wells on thyristor p base layer are made by boron implantation/drive-in for a steeper doping profile with higher concentrations while rest p layers of thyristor and free-wheeling diode parts are formed with Al implantation/drive-in for a doping profile of lower steepness. The free-wheeling diode part is isolated from the thyristor part by formation of separated p-well emitter for suppressing commutation between them, which is achieved during the formation of thyristor p-base layer.

  • PDF

KIST와 FZ-Julich SOFC간의 출력성능 비교 (Comparison of the Power Generating Characteristics of KIST- and FZ-Julich SOFCs)

  • 정화영;이상철;;김혜령;이해원;이종호
    • 한국세라믹학회지
    • /
    • 제44권12호
    • /
    • pp.703-709
    • /
    • 2007
  • We evaluate and compare the power generating characteristics of the anode supported SOFCs which have been fabricated from KIST and FZ-Julich in Germany. The performance and electrochemical property of each unit cell was characterized at the temperature range of $650-850^{\circ}C$ under same operating conditions and its microstructural property was thoroughly investigated via SEM after the performance test. According to the investigation, KIST- and FZJ SOFC showed different power generating characteristics in their temperature dependances due to their different design of electrode microstructure, especially the cathode microstructure. FZJ SOFC showed better performance at high temperature while showed lower performance at lower temperature. From the investigation about the correlation between microstructure and electrochemical property, we found that the superior performance of FZJ SOFC at high temperature was mainly due to its lower cathodic polarization resistance whereas better performance of KIST SOFC at lower temperature was mostly attributed to the lower ohmic resistance.

Monitoring Ion Energy Distribution in Capacitively Coupled Plasmas Using Non-invasive Radio-Frequency Voltage Measurements

  • Choi, Myung-Sun;Lee, Seok-Hwan;Jang, Yunchang;Ryu, Sangwon;Kim, Gon-Ho
    • Applied Science and Convergence Technology
    • /
    • 제23권6호
    • /
    • pp.357-365
    • /
    • 2014
  • A non-invasive method for ion energy distribution measurement at a RF biased surface is proposed for monitoring the property of ion bombardments in capacitively coupled plasma sources. To obtain the ion energy distribution, the measured electrode voltage is analyzed based on the circuit model which is developed with the linearized sheath capacitance on the assumption that the RF driven sheath behaves like a simple diode for a bias power whose frequency is much lower than the ion plasma frequency. The method is verified by comparing the ion energy distribution function obtained from the proposed model with the experimental result taken from the ion energy analyzer in a dual cathode capacitively coupled plasma source driven by a 100 MHz source power and a 400 kHz bias power.

Characteristics of Al Doped ZnO Thin Film by Modulated Pulsed Power Magnetron Sputtering

  • 양원균;주정훈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.430-430
    • /
    • 2012
  • Modulated pulsed power (MPP) 스퍼터링은 펄스 전압 shape, amplitude, duration의 modulation을 통해 증착율 손실을 극복하는 고출력 펄스 마그네트론 스퍼터링의 한 종류이다. Micro second 범위에서 on/off 시간을 다중 세트 형태로 자유롭게 프로그램 할 수 있어서 아킹 없이 고전류 영역의 마그네트론 동작을 할 수 있으므로, 고주파 유도 결합 플라즈마원이나 마이크로웨이브 투입 등의 부가적인 플라즈마 없이도 스퍼터링 재료의 이온화 정도를 획기적으로 높일 수 있는 장점을 가지고 있다. 본 연구에서는 $2{\times}1{\times}0.2$의 sputtering system에서 기판 캐리어를 이용해서 $400{\times}400mm$ 기판을 $272{\times}500mm$ 크기의 AZO target (Al 2 wt%)이 설치되어 있는 moving magnet cathode (MMC)을 이용하여 MPP로 증착했다. 두 종류의 micro pulse set을 하나의 macro pulse에 사용함으로서 weakly ionized plasma와 strongly ionized plasma를 만들 수 있다. 다양한 micro pulse set을 이용하여 평균 전력 2 kW에서 peak 전력을 4 kW에서 45 kW까지 상승 시킬 수 있으며, 이 때 타겟-기판 거리 80 mm에서 이온전류밀도는 $5mA/cm^2$에서 $20mA/cm^2$까지 상승했다. MPP는 같은 평균 전력에서 repetition frequency가 증가할 때, 증착 속도가 증가했으며, 같은 repetition frequency에서 macro pulse length가 증가할 때도, 증착 속도가 증가했다. 최적화된 marco, micro pulse set에서 증착 속도는 평균 전력 2 kW에서 110 nm/min이었고, 700 nm의 박막에서 비저항은 $1-2{\times}10^{-3}ohm{\cdot}cm$였다. 표면거칠기 Rrms는 약 3 nm였고, 400-700 nm 영역의 평균 투과도는 72-76%였다.

  • PDF

A High-efficiency Method to Suppress Transformer Core Imbalance in Digitally Controlled Phase-shifted Full-bridge Converter

  • Yu, Juzheng;Qian, Qinsong;Sun, Weifeng;Zhang, Taizhi;Lu, Shengli
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.823-831
    • /
    • 2016
  • A high-efficiency method is proposed to suppress magnetic core imbalance in phase-shifted full-bridge (PSFB) converters. Compared with conventional solutions, such as controlling peak current mode (PCM) or adding DC blocking capacitance, the proposed method has several advantages, such as lower power loss and smaller size, because the additional current sensor or blocking capacitor is removed. A time domain model of the secondary side is built to analyze the relationship between transformer core imbalance and cathode voltage of secondary side rectifiers. An approximate control algorithm is designed to achieve asymmetric phase control, which reduces the effects of imbalance. A 60 V/15 A prototype is built to verify the proposed method. Experimental results show that the numerical difference of primary side peak currents between two adjacent cycles is suppressed from 2 A to approximately 0 A. Meanwhile, compared with the PCM solution, the efficiency of the PSFB converter is slightly improved from 93% to 93.2%.

원통형 고체산화물 연료전지와 마이크로 가스터빈 하이브리드 시스템의 성능해석을 위한 모델링 (Modeling for the Performance Analysis of a Tubular SOFC/MGT Hybrid Power System)

  • 송태원;손정락;김재환;김동섭;노승탁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2070-2075
    • /
    • 2004
  • Performance of a solid oxide fuel cell (SOFC) can be enhanced by converting thermal energy of its high temperature exhaust gas to mechanical power using a micro gas turbine (MGT). A MGT plays also an important role to pressurize and warm up inlet gas streams of the SOFC. In this study, the influence of performance characteristics of the tubular SOFC on the hybrid power system is discussed. For this purpose, detailed heat and mass transfer with reforming and electrochemical reactions in the SOFC are mathematically modeled, and their results are reflected to the performance analysis. The analysis target is 220kWe SOFC/MGT hybrid system based on the tubular SOFC developed by Siemens-Westinghouse. Special attention is paid to the ohmic losses in the tubular SOFC counting not only current flow in radial direction, but also current flow in circumferential direction through the anode and cathode.

  • PDF

유전 및 압전특성에 따른 LCD Backlight용 압전 트랜스포머의 출력전력특성 (Output Power characteristics of the Piezoelectric Transformer for LCO Backlight with Piezoelectric and Piezoelectric Properties)

  • 민석규;류주현;정회승;홍재일;윤현상;손은영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.852-856
    • /
    • 2000
  • In this paper, we investigated the output power, step-up ratio and efficiency properties of piezoelectric transformer with dielectric and piezoelectric characteristics of manufactured ceramics. The piezoelectric transformers with $2.0$\times$10$\times$48[$mm^3$] size were fabricated and its electrical properties were measured. When output power of 6W was constantly maintained, T2 piezoelectric transformer showed the minimum temperature rise of $9(^{\circ}C)$ at $150(K\Omega)$ load resistance. However, T1 piezoelecric transformer showed the temperature rise of $7.2(^{\circ}C)$ at $200(K\Omega)$ load resistance. The 6[w] CCFL (Cold Cathode Fluorescent Lamp) was successfully driven by T1 and T2 piezoelectric transformer but, its temperature rise $\Delta$T[$^{\circ}C)$] was generated more than $20(^{\circ}C)$. It is concluded that we have to design the piezoelectric transformers so that its output impedance correspond to the load impeadance, including any stray capacitance.

  • PDF

30kW, 95GHz 자이로트론 구동을 위한 50kV, 100kW 고전압 전원장치 (50kV, 100kW High Voltage Power Supply for 30kW, 95GHz Gyrotron)

  • 장성록;서정호;안석호;김종수;류홍제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.345-346
    • /
    • 2015
  • 본 논문은 30kW, 95GHz 자이로트론을 구동하기 위한 50kV, 100kW 출력의 Cathode Power Supply(CPS) 설계에 대해 기술한다. 자이로트론 구동 시스템의 신뢰성과 효율성 향상을 위해 고효율 공진형 컨버터 토폴로지를 이용한 3개의 컨버터 모듈을 기반으로 출력단이 직렬로 구성된 모듈의 3상 운전을 통해 낮은 출력 전압 리플과 함께 아크 발생 시 부하 단으로 전달되는 에너지를 최소화 할 수 있도록 CPS를 설계한다. 또한 고전압 전원장치의 절연에 대한 신뢰성 확보와 전력밀도 향상을 위한 변압기 및 정류부의 효율적인 절연 설계 및 구현에 대하여 기술한다. 설계된 CPS의 실험결과를 통해 30kW, 95GHz 자이로 트론을 구동하기 위한 전원장치 설계의 타당성과 우수성을 검증한다.

  • PDF

100 kW급 용융탄산염 연료전지 시스템 개발 III (시스템 제어 및 운전모드) (System Development of a 100 kW Molten Carbonate Fuel Cell III (System Control and Operation Mode))

  • 임희천;안교상;서혜경;엄영창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1350-1352
    • /
    • 2003
  • For developing a 100 kW MCFC power generation system, Several design parameters for a fuel cell stack and system analysis results by Cycle Tempo, a processing computer soft ware, were described. Approximately two substacks with 90 cells are required to generate 100 kW at a current density of $125\;mA/cm^2$ with $6000\;cm^2$ of cells. An overall heat balance was calculated to predict exit temperature. The 100 kW power is expected only under pressurized operation condition at 3 atm. Recycle of cathode gas by more than 50% is recommended to run the stack at $125\;mA/cm^2$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition. The fuel cell power generation system was designed conceptually with several choices of utilization of anode exhaust gas. To operate and evaluate the MCFC system, control and measurement system and operation mode are designed before 100 MCFC system construction. In system control schematics, OS, PLC and MMI were consisted and have roles for MCFC system control. For operation of 100 kW MCFC system, NS, PS PR mode were considerated step by step and simulated.

  • PDF