Effects of Electric Current and Potential on the Electrokinetic Removal of Heavy Metals from an Abandoned Mine Tailings

  • Shin, Hyun-Moo;Lee, Chang-Eun
    • Journal of Environmental Science International
    • /
    • v.13 no.2
    • /
    • pp.149-159
    • /
    • 2004
  • In the removal of heavy metals from the mine deposit using electrokinetic processes, the effects of operation under both constant current and constant potential conditions were estimated. The results of soil pH distributions for DDW-20 V and DDW-100 mA cases after the electrokinetic remediation tests were observed. In the former case, soil pH was not much changed and kept to almost constant value just little higher than initial soil pH of 3.52, except near the cathode, which was about pH 5. While in the latter case, soil pHs of anode and the cathode regions were less than pH 3 and about 6, respectively. The electroosmotic flow to the cathode increased rapidly till 10 hrs and decreased steadily and then maintained to constant rate until the end of operation at constant current condition. Electric potential gradient was continuously increased to as much as 34.375 V/cm. At the steady state, values of the apparent electric conductivity for DDW-20 V and DDW-100 mA were around 40 ${\mu}\textrm{s}$/cm and 30 ${\mu}\textrm{s}$/cm, respectively. In the DDW-100mA test, Cu, Cd, and Zn except Pb showed the tendency of moving toward the cathode. While in the DDW-20 V case, it was observed that Cu, Zn, and Pb except Cd were not moved to any directions. The results of the tests demonstrated that the electrokinetic soil remediation process could be operated better under constant current condition than constant electric potential condition.

Preparation and Characteristics of Li/$V_6O_{13}$ Secondary Battery (Li/$V_6O_{13}$ 2차전지의 제조 및 특성)

  • Moon, S.I.;Jeong, E.D.;Doh, C.H.;Yun, M.S.;Yum, D.H.;Chung, M.Y.;Park, C.J.;Youn, S.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.136-140
    • /
    • 1992
  • The purpose of this research is to develop the lithium secondary battery. This paper describes the preparation, electrochemical properties of nontstoichiometric(NS)-$V_6O_{13}$ and characteristics of Li/$V_6O_{13}$ secondary battery. NS-$V_6O_{13}$ was prepared by thermal decomposition of $NH_4VO_3$ under Ar stream of 140ml/min~180ml/min flow rate. And then, this NS-$V_6O_{13}$ was used for cathode active material. Cathode sheet was prepared by compressing the composite of NS-$V_6O_{13}$, acetylene black(A.B) and teflon emulsion (T.E). Characteristics of the test cell are summarised as follows. Oxidation capacity of NS-$V_6O_{13}$ was about 20% less than its reduction capacity. A part of NS-$V_6O_{13}$ cathode active material showed irreversible reaction in early charge-discharge cycle. This phenomena seems to be caused by irreversible incoporation/discoporation of lithium cation to/from NS-$V_6O_{13}$ host. Discharge characteristics curve of Li/$V_6O_{13}$ cell showed 4 potential plateaus. Charge-discharge capacity was declined in the beginning of cycling and slowly increased in company with increasing of coulombic efficiency. Energy density per weight of $V_6O_{13}$ cathode material was as high as 522Wh/kg~765Wh/kg.

  • PDF

Performance evaluation by flow channel effect for a passive air-breathing Direct Methanol Fuel Cell (수동급기 직접 메탄올 연료전지의 유로에 따른 성능 평가)

  • Chang, Ikw-Hang;Ha, Seung-Bum;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.45-48
    • /
    • 2008
  • This paper presents a passive air-breathing direct methanol fuel cell (DMFC) which has been designed and tested. The single cell is fuelled by methanol vapor that is supplied through flow channel from a methanol reservoir at the anode, and the oxygen is supplied via natural air-breathing at the cathode. The methods for supplying the methanol vapor to the single cell were parallel channel and chamber. This research investigates various methods to identify the effects of using flow channels for providing the methanol vapor at the anode, and the opening ratio between the inlet and outlet ports for the methanol flow at the anode. The best flow channel condition for passive DMFC was a chamber, and the opening ratio was 0.8. Under these conditions, the peak power was 10.2mW/$cm^2$ at room temperature and ambient pressure. The key issues for the Passive DMFCs for using methanol vapor are that sufficient methanol needs to be supplied using a large as possible opening ratio. However, it is shown that the performance of the passive DMFC, which has a channel at the anode,is low due to the low differential pressure and insufficient methanol supply rate.

  • PDF

Design and Optimization of Glow Discharge Atomic Absorption Spectrometry System (글로우방전 원자흡수시스템의 구성 및 최적화에 관한 연구)

  • Kim, Hyo Jin;Jang, Hye Jin;Lee, Gae Ho;Jo, Jeong Hwan
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.3
    • /
    • pp.214-220
    • /
    • 1994
  • A glow discharge atomic absorption system for the direct analysis of conducting solid samples has been designed and constructed. An arrestor made of machinable ceramic which is a main component for confining the discharge between cathode and anode is modified to have a better stability in discharge. Discharge voltage or current, shape of arrestor, pressure, and gas flow rate can be controlled by an ADC/DAC board with a personal computer. The effect of discharge parameters such as discharge voltage, pressure, and gas flow rate on the sample loss rate, absorbance, and the surface morphology of sample by SEM has been studied to find optimum discharge conditions.

  • PDF

A Study on Thermal Management of Stack Supply Gas of Solid Oxide Fuel Cell System for Ship Applications (선박 전원용 고체산화물형 연료전지(SOFC) 시스템의 스택 공급 가스의 열관리 문제에 관한 연구)

  • Park, Sang-Kyun;Kim, Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.765-772
    • /
    • 2011
  • In this research, the fuel cell system model capable of generating codes in real time was developed to construct of a HIL (Hardware-In-the-Loop) for a SOFC-powered ship. Moreover, the effects of the distribution of the exhaust gas flow rates in a stack, the flow rates of fuels and temperature of air supplied on the temperature characteristics of fuels supplied to the cathode and the anode, the output power of the stack and system efficiency are examined to minimize the temperature difference between fuels supplied to the stack used in a 500kW SOFC system using methane as a fuel. As a result, the temperatures of fuels supplied to the cathode and the anode maintain at 830K when the opening factor of three-way valve located at outlet of turbine is 0.839. Also the process for optimization of methane flow rate considering the fuel cell stack and system efficiency is required to increase the temperatures of fuels supplied to the stack.

Characterization of Cold Hollow Cathode Ion Source by Modification of Electrode Structure (전극 구조 변화에 따른 Cold Hollow Cathode Ion Source의 특성 변화)

  • Seok, Jin-Woo;Chernysh, V.S.;Han, Sung;Beag, Young-Hwoan;Koh, Seok-Keun;Yoon, Ki-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.10
    • /
    • pp.967-972
    • /
    • 2003
  • The inner-diameter 5 cm cold hollow cathode ion source was designed for the high current density and the homogeneous beam profile of ion beam. The ion source consisted of a cylindrical cathode, a generation part of magnetic field, a plasma chamber, convex type ion optic system with two grid electrode, and DC power supply system. The cold hollow cathode ion sources were classified into standard type (I), electron output electrode modified type (II). The operation of the ion source was done with discharge current, ion beam potential and argon gas flow rate. The modification of electron output electrode resulted in uniform plasma generation and uniform area of ion beam was extended from 5 cm to 20 cm. Improved ion source was evaluated with beam uniformity, ion current, team extraction efficiency, and ionization efficiency.

A PRELIMINARY STUDY ON THE EFFECT OF SLANTED GROOVE MIXER (SGM) ON THE PERFORMANCE OF A PEM FUEL CELL (기울어진 그루브 믹서가 고분자 전해질 연료전지 성능에 미치는 영향에 대한 기초연구)

  • Yun, S.C.;Park, J.W.;Kang, K.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.93-96
    • /
    • 2009
  • In the cathode channel of a PEM fuel cell, the local concentration of oxygen near the gas diffusion layer (GDL) decreases in streamwise direction due to chemical reactions, which degrades the efficiency of the oxygen consumption and overall fuel cell efficiency. We numerically studied the influence of the swirling flow generated by a slanted groove mixer (SGM) on the concentration distribution of oxygen. We found that the swirling flow can increase the concentration of oxygen near the GDL, and subsequently improves the oxygen consumption rate.

  • PDF

Development of 4 Types of Fuel Cell's Blower (연료전지 블로어 4기종 국산화 개발)

  • Tak, Bong-Yeol;Kim, Chan-Gyu;Lee, So-A;Jang, Chun-Man
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.91-91
    • /
    • 2011
  • This paper describes development procedure of the four types of fuel cell's blowers: pressurized fuel blower, selective oxidation air blower, cathode air blower, and burner air blower. Diaphragm blowers having two heads are selected to maintain force balance when the rotating arms are moving by the driving motor. Dimensions of a diaphragm cavity is designed according to the optimal design procedure using numerical simulation and experimental measurement. Experimental apparatus is designed by considering the bower characteristics having low flow rate and high pressure. Test blower is operated by a diaphragm, which has suction and discharge port on the top of the blower. For analyzing the internal flow of the blower, three-dimensional Navier-Stokes analysis is introduced in the present study. Throughout the optimal design of the blowers, blower performance is enhanced by reducing the unbalance motion of the rotating arm and loss region in the diaphragm cavity.

  • PDF

Dry-out conditions of free-breathing PEMFC with dry $H_2$ gas (자연급기 무가습 연료전지의 Dry-out조건)

  • Park, Sang-Kyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.225-230
    • /
    • 2006
  • This study investigates drying condition when a small fan is added to a operating the free-breathing proton exchange membrane fuel cells (PEMFCs) with dry $H_2$ and Air. Polarization tests were conducted on PEMFCs at cell temperatures between 30 and $50^{\circ}C$ under dry operation. In the results, the cell performance strongly depended on the cell temperature and the cathode gas stoichiometric flow rates. The cell performance increases as cell temperature decreases from 50 to $30^{\circ}C$. In the domain where the stoichiometry of air is quite large, reduction of the concentration overpotential compensated the increased internal resistance due to drying. The maximum performance was obtained at the small air flow rate beyond which flooding occurs. This indicates that the fan should be operated in the stoichiometry domain with a well designed cell structure to avoid flooding.

2차원 토양 실험장치에서 동전기-펜턴 공정의 이해

  • 양지원;박지연;김상준;이유진;기대정
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.310-313
    • /
    • 2003
  • Removal of phenanthrene by electrokinetic method combined with Fenton-like process was studied in a model system. The scale of reactor was 120 cm in length, 10 cm in width, and 50 cm in height. Sand was selected as a model soil. Bentonite was filled in the space between reservoir and contaminated soil to control the flow rate of water. When constant voltage of 100 V was applied to this system, current varied from 1000 mA to 290 mA for 28 days. pH of anode and cathode reservoirs became to 2 and 13, respectively. Removal efficiency of phenanthrene was more than 60 %.

  • PDF