• Title/Summary/Keyword: Catheters, Indwelling

Search Result 38, Processing Time 0.025 seconds

Knowledge and Performance Level of Infection Control Guidelines on Indwelling Urinary Catheter, Central Venous Catheter and Ventilator Among Intensive Care Nurses (중환자실 간호사의 유치도뇨관, 중심정맥관 및 인공호흡기 감염관리에 대한 지식과 수행도)

  • Ha, Hyun-Jung;Park, Jung-Ha;Kim, Myung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.113-120
    • /
    • 2016
  • The purpose of this study is to identify the knowledge of and adherence to the infection control guidelines for indwelling urinary catheters, central venous catheters and ventilators among intensive care nurses. The subjects were 175 intensive care nurses working in 2 upper general hospitals and 3 general hospitals. Data were collected from July 1 to July 31, 2013. The collected data were analyzed by descriptive statistics, t-test and ANOVA using SPSS 18.0 for Windows. The mean scores of the knowledge of the infection control guidelines on indwelling urinary catheters, central venous catheters and ventilators were 0.87, 0.82 and 0.82 points, respectively. The average scores for the adherence to the infection control guidelines for indwelling urinary catheters, central venous catheters and ventilators were 4.18, 4.04 and 4.07 points, respectively. Statistically significant correlations were found between the knowledge of and adherence to the infection control guidelines for indwelling urinary catheters (r=.72, p<.00), central venous catheters (r=.54, p<.001) and ventilators (r=.30, p<.001). The knowledge of and adherence to the infection control guidelines for indwelling urinary catheters differed significantly according to gender, educational status, total career, number of patients, type of hospital, and attendance of seminar. The knowledge of and adherence to the infection control guidelines for central venous catheters differed significantly according to educational status, total career, number of patients, type of hospital, and attendance of seminar. The knowledge level of the infection control guidelines for the ventilator differed significantly according to the total career. The results of this study indicate that education and training programs for improving the knowledge of adherence to the infection control guidelines should be developed.

A Study on Knowledge, Educational Needs and Educational Experience for Indwelling Catheter Management in the Families of Home Care Clients (유치도뇨관 삽입 가정간호대상자 가족의 유치도뇨관 관리에 관한 지식, 교육요구 및 교육경험)

  • Kim, Jung-Soon;Lee, Sang-Ju;Kang, In-Soon
    • Journal of Home Health Care Nursing
    • /
    • v.12 no.1
    • /
    • pp.92-116
    • /
    • 2005
  • Purpose: This study was a predicative survey to provide home care clients with indwelling urinary catheters for furnishing basic educational material to their families by analyzing the family members' knowledge, educational needs and educational experience about indwelling catheter management. Method : The subjects consisted of 108 family members who cared for home care clients with indwelling catheters. Data were collected by home care nurses in nine hospitals in Pusan, who directly interviewed with them through questionnaires from Sep. 6th to 30th in 2004. The questionnaires for data collection were developed through pre-survey and reference review. The collected data was analyzed by using frequency, percentile, mean, variation, t-test, ANOVA on SPSS 10.1 package. Results : There were characters of home care clients with indwelling catheters: women(67.6%) were more than men; the average age of them was $69.60{\pm}14.99$ years old; neurogenic and cerebrovascular diseases(80.0%) were the most common disease group; 81.5% of them were totally dependent on others in terms of level of activity. Home care clients' families had these characters: women(76.9%) were more than men; the average age was $54.5{\pm}13.70$ years old; 46.3% of them were parents or sons or daughters in terms of relation with patient; tl1e average care period was $39.8{pm}34.20$ months. Level of knowledge about indwelling catheter management of the family members were 69.8% and its mean were $20.24{\pm}4.53$. Educational needs were 90.9% and its mean were $14.55{\pm}3.56$. Educational experience were 53.3% and its mean were $8.53{\pm}4.30$. 'Complications in using an indwelling catheter', 'Symptoms to call for a home care nurse' and 'Method to attach an indwelling catheter' were high ranked in both educational needs and educational experience. 'Anatomy of urinary tract', 'Functions of urinary tract' and 'Catheter placement' were low ranked in both educational needs and educational experience Level of knowledge about indwelling catheter management of the families showed a significant difference according to their age(F=5.35, p=0.01). Educational needs showed a significant difference according to care period(F=3.06, p=0.04). Conclusion: the family members' level of knowledge and educational experience about indwelling catheter management and their educational were not sufficient while their educational needs were high. In other words although the family members were acknowledged education needs, but the care for the patients with indwelling catheter weren't performed well because of their lack of related knowledge. Therefore systematic educational programs about indwelling catheter management for home care clients and their families should be made on the base of this study.

  • PDF

Bacteriological Culture of Indwelling Epidural Catheters (경막외 카테터의 장기간 거치시 말단부의 감염 조사)

  • Yang, Seung-Kon;Lee, Hee-Jeon;Kim, Seung-Hee;Lee, Young-Chul;Choi, Whan-Young;Kim, Chan;Kim, Soon-Yul
    • The Korean Journal of Pain
    • /
    • v.8 no.2
    • /
    • pp.308-311
    • /
    • 1995
  • The incidence of contamination of epidural catheters used for pain control was investigated. To prevent epidural infection, all patients with epidural catheters had taken amoxacillin 1.5gm/day orally. Of the cultures of catheters catched from 303 patients undergoing continuous epidrual catheterization, 5 catheters (1.7%) were found to be contaminated; cervical 1/86 (1.2%), thoracic 1/27 (3.7%), and lumbar 3/190 (1.6%). Staphylococcus epidermidis was the most common etiologic agent (60%). To prevent epidural infection, sterilization of the skin around the epidural catheter and prophylactic use of broad-spectrum antibiotics are thought to be beneficial.

  • PDF

Bacteriological Culture of Indwelling Epidural Catheters (지속적 경막외 차단후 카테터 끝의 감염에 대한 검사)

  • Yoon, Duck-Mi;Lee, Youn-Woo;Oh, Hung-Kun
    • The Korean Journal of Pain
    • /
    • v.4 no.1
    • /
    • pp.26-30
    • /
    • 1991
  • Continuous epidural analgesia is widely used in pain management. We investigates the incidence of contamination of epidural catheters used in epidural catheters for pain control. The tips of epidural catheters were examined for bacterial growth after use. In culture from 250 patients undergoing continuous epidural catheterization, 33(13.2%) catheters were found to be contaminated: staphylococcus epidermis 66.9%; staphylococcus aureus 12.1%; alpha streptococcus 12.1%; and others 9.1%. One significant epidural infection occured. One of the most common causes of the epidural infection during long time epidural block is the transmission of the microorganism from the contaminated skin to the epidural space along the epidural catheter. To prevent epidural infection, sterilization of the skin around the epidural catheter is essential.

  • PDF

Prevention of Catheter-related Infections (CRIs) using Ciprofloxacin

  • Jeon Sung Min;Kim Mal Nam
    • Biomedical Science Letters
    • /
    • v.10 no.3
    • /
    • pp.245-251
    • /
    • 2004
  • Microbial infection provokes one of the most serious complications to the patients with indwelling catheters. Ciprofloxacin (CFX) was added into the catheter materials (polyurethane or silicone) during the manufacturing process to avoid the microbial infection. Efficacy of the catheters containing CFX was investigated by using the in vitro zone of growth inhibition test method. The catheters made of polyurethane or silicone exhibited a strong antimicrobial activity against the major catheter-related microorganisms (S. aureus, S. epidermidis, P. aeruginosa and E. coli), when CFX was incorporated into the catheters. Fetal bovine serum (FBS) did not affected antimicrobial activities of the polyurethane catheters with CFX loading of 0.5 and 1.0% (W/W) against S. aureus and S. epidermidis. However, the polyurethane catheters with 1.0% (W/W) of CFX loading showed a significantly (P<0.05) reduced antimicrobial activity against E. coli when the catheters were exposed to FBS. Silicone catheters with 1.0 and 1.5% (W/W) of CFX loading demonstrated effective antimicrobial activity against S. epidermidis for at least 2 weeks. These results suggest that the use of catheters containing ciprofloxacin could be effective in preventing catheter-related infections.

  • PDF

In vitro Retention of Antimicrobial Activity of Ciprofloxacin-incorporated Central Venous Catheters

  • Jeon, Sung-Min;Kim, Mal-Nam
    • Biomedical Science Letters
    • /
    • v.13 no.3
    • /
    • pp.175-182
    • /
    • 2007
  • In vitro ciprofloxacin (CFX)-release study and bioassay using microorganisms were performed to estimate the retention of the antimicrobial activity of the CFX-incorporated central venous catheters (CFX-CVCs). The release experiments were carried out under the optional CFX-release conditions to mimic the in vivo environment. The release of CFX experienced an initial burst followed by a slow and steady matrix-diffusion controlled release. The 1.0CP (polyurethane catheter containing 1.0% (w/w) of CFX) under dynamic condition showed a near zero-order CFX release profile, which is beneficial for the long-tenn antimicrobial activity. The modified Kirby-Bauer method was performed employing S. aureus and E. coli to evaluate the retention of antimicrobial activity of the catheters retrieved from the release experiments. The 1.0CP showed the long-term antimicrobial activity (${\geq}\;21$ days) against both S. aureus and E. coli. These results indicate that 1.0CP is useful as a long-tenn indwelling CVC.

  • PDF

Use of Imaging Agent to Determine Postoperative Indwelling Epidural Catheter Position

  • Uchino, Tetsuya;Hagiwara, Satoshi;Iwasaka, Hideo;Kudo, Kyosuke;Takatani, Junji;Mizutani, Akio;Miura, Masahiro;Noguchi, Takayuki
    • The Korean Journal of Pain
    • /
    • v.23 no.4
    • /
    • pp.247-253
    • /
    • 2010
  • Background: Epidural anesthesia is widely used to provide pain relief, whether for surgical anesthesia, postoperative analgesia, treatment of chronic pain, or to facilitate painless childbirth. In many cases, however, the epidural catheter is inserted blindly and the indwelling catheter position is almost always uncertain. Methods: In this study, the loss-of-resistance technique was used and an imaging agent was injected through the indwelling epidural anesthesia catheter to confirm the position of its tip and examine the migration rate. Study subjects were patients scheduled to undergo surgery using general anesthesia combined with epidural anesthesia. Placement of the epidural catheter was confirmed postoperatively by injection of an imaging agent and X-ray imaging. Results: The indwelling epidural catheter was placed between upper thoracic vertebrae (n = 83; incorrect placement, n = 5), lower thoracic vertebrae (n = 123; incorrect placement, n = 5), and lower thoracic vertebra-lumbar vertebra (n = 46; incorrect placement, n = 7). In this study, a relatively high frequency of incorrectly placed epidural catheters using the loss-of-resistance technique was observed, and it was found that incorrect catheter placement resulted in inadequate analgesia during surgery. Conclusions: Although the loss-of-resistance technique is easy and convenient as a method for epidural catheter placement, it frequently results in inadequate placement of epidural catheters. Care should be taken when performing this procedure.

Synthesis and Characterization of Amphiphilic Polyurethanes as Coating Materials for Urinary Catheters (요도용 카테타 도포용 양친성 폴리우레탄의 합성 및 분석)

  • Park Jae-Hyung;Kim Kwang-Meyung;Chung Hes-Son;Kwon Ick-Chan;Bae You-Han;Jeong Seo-Young
    • Polymer(Korea)
    • /
    • v.30 no.3
    • /
    • pp.247-252
    • /
    • 2006
  • The long-term use of indwelling urinary catheters can allow bacterial adhesion to their surfaces, followed by the catheter-associated urinary tract infection. In an attempt to minimize the bacterial adhesion, various amphiphilic polyurethanes (APUs) were synthesized as potential coating materials for urinary catheters. By varying composition of the soft segments such as PEO, PTMO, and PDMS, four different polyurethanes were synthesized. All the APU-coated urinary catheters had the smooth surfaces and showed higher hydrophilicity, compared to the commercial silicone catheters. In particular, the use of APUs with the higher PEG content significantly augmented hydrophilicity and remarkably reduced the total amount of bacteria adhering to the surface. Overall, the APUs prepared in this study provided the promising potential as coating materials for urinary catheters.

Usefulness of Tunneled Trans-saphenous IVC Catheters for Long Term Venous Access in Pediatric Patients (소아환자에서 대복재정맥을 통한 하대정맥도관법의 유용성)

  • Kim, Seung-Hwan;Kim, Seong-Min;Oh, Jung-Tak;Han, Seok-Joo;Choi, Seung-Hoon
    • Advances in pediatric surgery
    • /
    • v.12 no.2
    • /
    • pp.167-174
    • /
    • 2006
  • Central venous catheter (CVC) for long-term venous access is indispensable for various reasons including hyperalimentation, frequent blood sampling, frequent IV drug use in pediatric patients. We report clinical experience of surgical neonates in whom CVC was inserted primarily via great saphenous vein into suprarenal inferior vena cava. From March 2004 to March 2006, we performed CVC insertion via saphenous vein - contralateral side to main wound - into suprarenal inferior vena cava in surgeries of neonates. 2.7Fr or 4.2Fr, single lumen, tunneled Broviac catheters (Bard Access system, Inc, Salt Lake City, Utah) were used. Skin exit site of tunneled catheter was located in ipsilateral flank area just below edge lower rib. At the end of the procedure, location of the catheter tip was confirmed by plain radiography of abdomen. We retrospectively reviewed the admission records of the patients including nursing staff charts. Nine (50.0 %) patients were male and nine (50.0%) were female. Median gestational age was 38 weeks (range, 29-42 weeks) and median birth weight was 3,105 gm (range, 1,040-3,720 gm). Median age at catheter insertion was 38.5 days (range, 1-236 days). The purpose of CVC insertion was short-and long-term hyperalimentation in nine (50.0 %) patients. CVC insertion was performed in operation room under general anesthesia in sixteen (88.9 %) patients (in these cases, CVC insertion was performed just prior to concurrent operation) and neonatal intensive care unit (NICU) under local anesthesia with adequate sedation in two (11.2%). During the admission period (total catheter-indwelling time: 553 days), CVC functioned well without any significant side effects. Transient swelling of the ipsilateral leg (n=1, 5.6 %) and transient migration of catheter tip (n=1, 5.6 %) were noted, which did not affect function of the indwelled CVC. Mean catheter-indwelling time was 30.7days (range, 3-72 days). All catheters were removed electively except two mortality case. Complications, such as thrombosis, infection, kinking or extravasation of drugs, were not observed in our study period. Tunneled trans-great saphenous vein inferior vena cava catheters are not only comparable to cervical CVCs in terms of function and complication rates, but also very beneficial in selected patients, especially those in whom cervical approach is technically impossible or contraindicated.

  • PDF

Effect of Peripheral Administration of Kisspeptin-10 on Dynamic LH Secretion in Prepubertal Ewes

  • Wang, Jun;Sun, Lei;Zhang, Tao;Zhou, Haizhu;Lou, Yujie
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.6
    • /
    • pp.785-788
    • /
    • 2012
  • The aim of the present study was to clarify the effect of kisspeptin-10 on LH secretion in prepubertal ewes. In experiment 1, prepubertal ewes fitted with indwelling jugular catheters were randomly assigned to receive 0, 0.5, 1 or 2 mg of kisspeptin-10 dissolved in saline, and serial blood samples were collected at 15-min intervals for 180 min to analyze the response curves of LH after injection. In experiment 2, prepubertal ewes fitted with indwelling jugular catheters were injected with 0 or 1 mg of kisspeptin-10 dissolved in saline and the injection was repeated 3 times at 1 h interval and serial blood samples were collected at 15-min intervals for 210 min to analyze the response curves of LH after injection. The results showed that single intravenous administration of 0.5, 1 and 2 mg of kisspeptin-10 all could significantly increased LH secretion in prepubertal ewes, and the effect of 1 and 2 mg of kisspeptin-10 on LH secretion was higher than that of 0.5 mg group. The results also showed that repeated intravenous administration of kisspeptin-10 could effectively increase LH secretion and repeated administration did not influence the effect of kisspeptin-10 on LH secretion in prepubertal ewe. In conclusion, the present study indicated that single or repeated intravenous administration of kisspeptin-10 could effectively increase LH secretion in prepubertal ewes.