Efficacy and Cost-Effectiveness of Portable Small-Bore Chest Tube (Thoracic Egg Catheter) in Spontaneous Pneumothorax

  • Joh, Hyon Keun;Moon, Duk Hwan;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • v.53 no.2
    • /
    • pp.49-52
    • /
    • 2020
  • Background: Primary spontaneous pneumothorax is commonly treated with chest tube insertion, which requires hospitalization. In this study, we evaluated the efficacy, costs, and benefits of a portable small-bore chest tube (Thoracic Egg; Sumitomo Bakelite Co. Ltd., Tokyo, Japan) compared with a conventional chest tube. Methods: We retrospectively analyzed all primary spontaneous pneumothorax patients who underwent treatment at Gangnam Severance Hospital between August 2014 and May 2018. Results: A total of 279 patients were divided into 2 groups: the conventional group (n=236) and the Thoracic Egg group (n=43). Of the 236 patients in the conventional group, 100 were excluded because they underwent surgery during the study period. The efficacy and cost were compared between the 2 groups. There was no statistically significant difference between the groups regarding recurrence (conventional group, 36 patients [26.5%]; Thoracic Egg group, 15 patients [29.4%]; p=0.287). However, the Egg group had statistically significantly lower mean medical expenses than the conventional group (433,413 Korean won and 522,146 Korean won, respectively; p<0.001). Conclusion: Although portable small-bore chest tubes may not be significantly more efficacious than conventional chest tubes, their use is significantly less expensive. We believe that the Thoracic Egg catheter could be a less costly alternative to conventional chest tube insertion.

A method of bedside urethrography before catheterization in pelvic trauma in Korea: a case report

  • Hojun Lee;Sung Yub Jeong;Kun Hwang
    • Journal of Trauma and Injury
    • /
    • v.36 no.4
    • /
    • pp.451-453
    • /
    • 2023
  • We introduce a convenient method of urethrography before catheterization for patients with pelvic trauma that can be used in a resuscitation area. A 10-mL syringe without a needle was used. X-ray contrast medium (Iohexol, 300 mg I/mL) was administered through the urethral orifice using a 10-mL syringe without needle and a simple pelvic anteroposterior film was taken (70 kilovolt [peak], 50 mAs). A 36-year-old soldier with a saddle injury from a gun barrel was taken to a trauma center. He had a pelvic fracture and complained of hematuria. Bedside urethrography above described was performed. The anterior urethra showed nonspecific findings, but dye leaked from the posterior urethra. Bedside Foley catheter insertion was attempted, but the catheter could not be advanced past the membranous urethra. Thereafter, suprapubic catheterization was performed. On the day of the injury, iliac artery embolization was carried out. The dislocated sacroiliac joint was also treated using open reduction and internal fixation. On hospital day 7, guidewire Foley insertion was performed. This bedside urethrography technique is simple and useful for pelvic fractures in which urethral injury is suspected.

Effect of advanced life support (ALS) on recovery of spontaneous circulation in out-of-hospital cardiac arrest patients (병원 밖 심정지 환자의 전문소생술이 자발순환 회복에 미치는 영향)

  • Soeun Park;ByoungGil Yoon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.28 no.2
    • /
    • pp.47-62
    • /
    • 2024
  • Purpose: This retrospective study analyzed the effects of advanced life support on the recovery of spontaneous circulation (SC) in patients with out-of-hospital cardiac arrest. Methods: The subjects of this study were out-of-hospital cardiac arrest patients transferred to the hospital by 119 paramedics in Gyeongsangbuk-do from January 1, 2021, to December 31, 2022, amounting to a total of 2,524 patients. Results: The younger the age, the higher the probability of recovery of spontaneous circulation, and it was higher when cardiac arrest occurred in a public place or was witnessed. If the patient's initial electrocardiogram rhythm is defibrillable, the probability of recovery from spontaneous circulation is high. The recovery of the spontaneous circulation rate decreased with time between the time of report and the time of contact with the patient. Recovery of the spontaneous circulation rate was high when mechanical chest compression devices and advanced airways were not used. Additionally, this study had positive effects on defibrillation, peripheral intravenous catheter insertion, and epinephrine infusion. Conclusion: Paramedics should actively perform peripheral intravenous catheter insertion and epinephrine infusion, and it should be possible to clearly determine whether defibrillation should be applied through electrocardiographic education.

The Central Venous Catheter-related Infection of Chlorhexidine-silver Sulfadiazine Coated Catheters in Medical ICU (내과계 중환자실 환자에서 Chlorhexidine-silver Sulfadiazine Coated Catheter의 중심정맥관 감염에 대한 연구)

  • Jung, Young Ju;Koh, Younsuck;Lim, Chae-Man;Lee, Jae Seung;Yu, Mi Hyun;Oh, Yeon Mok;Shim, Tae Sun;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.4
    • /
    • pp.389-396
    • /
    • 2005
  • Background : Central venous catheters(CVCs) area major source of nosocomial infection. Chlorhexidine-silver sulfadiazine coated catheters (CHSS) were developed to reduce the rate of CVC infection. However, the clinical effectiveness of CHSS in comparison wth non-coated catheter (NCC) remains to be evaluated. Methods : From January 2004 to December 2004 in medical intensive care unit (ICU) of Asan Medical Center, CVCs were inserted in 446 cases. We retrospectively analyzed characteristics of patients and catheterization,the catheter-related infection rate and colonization, microbiologic findings, and insertion sites (subclavian, jugular, femoral) according to the type of inserted CVCs (NCC: 187 cases, CHSS: 259 cases). Catheter related infection is defined as catheter related bacteremia and catheter related non-bacteremic sepsis. Results : 1) The mean age of the patients in each group was $62{\pm}16$ years, $63{\pm}15$ years (p=0.42), and sex ratio 94:50, 141:69 (p=0.9) in NCC and CHSS. Duration of ICU admission ($29{\pm}37$, $26{\pm}44$ p=0.42), duration of mechanical ventilation ($17{\pm}22$, $15{\pm}19$ p=0.17), and APACHE III score at the time of CVC insertion ($81{\pm}34$, $82{\pm}37$ p=0.61) were not different between both groups. 2) Mean duration of catheterization was 118 in NCC and 119 in CHSS (p=0.98). Number of catheter-days was 2176 days in NCC and 3035 days in CHSS. Catheter-related infection occurred in 9 (4.8%) cases receiving NCC and 4 cases (1.5%) receiving CHSS. Catheterrelated infection incidence per 1000 catheter-days was 4.1 and 1.3, respectively (p=0.04). CHSS was associated with a significant reduction of infection in jugular catheters regarding to insertion sites (p=0.01). 3) Microorganisms causing infection were Staphylococcus aureus (n=3), Candida (n=3), coagulase-negative Staphylococci (n=2), and Klebsiella (n=1) in NCC, and Candida species (n=2), coagulase-negative Staphylococci (n=2), Proteus (n=1) in CHSS. Conclusion : CHSS has significantly reduced the episodes of infection compared to NCC in jugular catheterization in medical ICU.

Easy and Safe Catheterization of the Innominate Vein (무명정맥의 쉽고 안전한 삽관)

  • 이흥섭;조창욱
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1401-1404
    • /
    • 1996
  • Central venous line insertion is an essential procedure in a cardiac operation. For this, percuteneous Insertion is usually done in the internal jugular vein or the subclavian vein. However, this method can create such complications as pneumothorax and hemothorax, and repeated failure in inserting the cathet r, especially in infant and child patients, can waste excessive time. Consequently, in our hospital, catheterization of the innominate vein was done after the completion of sternotomy in the cardiac operation of infant and child patients weighing under 1 Okg. During operation, the catheter was placed in the left atrium through the foramen ovate or pulmonary artery to be used for pressure monitoring. When the patient's hemodynamic became stabilized, the catheter was withdrawn to either the right atrium or superior vena casa to be used as the channel for fluid replacement or drug administration. In our hospital, this procedure has been used in 96 cases since 1989. No complications such as pneumothorax and hemothorax occilrred, and neither bleeding after the removal of the catheter was seen.

  • PDF

Selective Bronchial Suction Catheter after Resection Surgery of Lung -Case report- (폐절제술 후 선택적 기관지내 흡인도관 유치 -증례 보고-)

  • 조정수;김종원;김영대
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.884-887
    • /
    • 2004
  • We applied our technique of selective bronchial suctioning (SBS) for the treatment of atelectasis after resection surgery of lung in four patients with refractory atelectasis who were treated successfully. We considered that SBS using hydro-catheter insertion under local anesthesia above fourth tracheal ring is the effective technique for the treatment of refractory atelectasis when conventional respiratory therapy is not effective and a bronchoscopist is not available.

Permanent Transvenous Endocardial Pacemaker Inevitably Implanted Two Electrode Leads (두개의 전극도자를 사용하게 된 Permanent Transvenous Pacemaker Implantation: 1례 보고)

  • Kwack, Moon-Sub;Lee, Hong-Kyun
    • Journal of Chest Surgery
    • /
    • v.14 no.2
    • /
    • pp.168-174
    • /
    • 1981
  • Since cardiac pacemaker was first totally implanted by Chardack, Gage and Greatbatch [1966], the electrical circuity of the cardiac pacemaker has been improved, modified, and refined. The problem of transvenous electrodes, however, is still remained; this may be due to electrode displacement, exit and/or entrance block, lead fracture and insulation defects. In permanent cardiac pacing, Irreversible loss of function of the transvenous electrode catheter eventually requires insertion of new lead. Authors now report one case that disclosed easy displacement of electrode tip in early phase of implantation and then two years and five months later, malfunctioning electrode could not be withdrawn from the cardiovascular system because it has become firmly enclosed by fibrous tissue along its course from the vein tract to the right ventricle. Under such circumstances, the electrode catheter tip was left in tricuspid annulus after being sutured at its entrance and burying the loop of lead in generator pocket. New other one electrode was then reimplantation through left external jugular vein.

  • PDF

Caudal and epidural blocks in infants and small children: historical perspective and ultrasound-guided approaches

  • Kil, Hae Keum
    • Korean Journal of Anesthesiology
    • /
    • v.71 no.6
    • /
    • pp.430-439
    • /
    • 2018
  • In infants and small children, ultrasound (US) guidance provides ample anatomical information to perform neuraxial blocks. We can measure the distance from the skin to the epidural space in the US image and can refer to it during needle insertion. We may also visualize the needle or a catheter during real-time US-guided epidural catheterization. In cases where direct needle or catheter visualization is difficult, US allows predicting successful puncture and catheterization using surrogate markers, such as dura mater displacement, epidural space widening due to drug injection, or mass movement of the drug within the caudal space. Although many experienced anesthesiologists still prefer to use conventional techniques, prospective randomized controlled trials using US guidance are providing increasing evidence of its advantages. The use of US-guided regional block will gradually become widespread in infants and children.

Guidelines for Free-Hand Aspiration(FHA) of Putaminal Hemorrhage (피각부 자발성 뇌내출혈의 혈종흡입술을 위한 지표)

  • Yim, Sin Gil;Oh, Min Suk;Lim, Jun Seob;Kang, Myung Gi;Kwak, Yeon Sang;Park, Seung Gyu;Song, Gyung Bae;Kim, Han Yung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.294-299
    • /
    • 2001
  • Objectives : CT-guided stereotactic evacuation for spontaneous intracerebral hemorrhage can minimize the brain damage and can be performed safely and simply under local anesthesia. But that procedure is time consuming and has a risk of rebleeding because of the stress during head pin fixation. So authors describe easy and precise guidelines for FHA of putaminal hemorrhage without stereotactic instrument. Methods and Materials : We analyzed the data of 298 patients who underwent CT-guided stereotactic aspiration of putaminal hematoma in our hospital between January 1990 and December 2000. We divided the patients into three groups according to the location of hematoma : anterior portion, middle portion and posterior portion of putamen. Total number of catheters inserted into the hematoma were 345 and there were with regard to the direction and depth of catheters. Results : Proposed guidelines of catheter insertion to putaminal hemorrhage in our institution. 1) hematoma at the anterior portion of putamen ; Direction of catheter was the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between external auditory meatus(EOM) and 1cm posterior to EOM. Depth of catheter was 6-6.5cm. 2) hematoma at the middle portion of putamen ; Direction of catheter was the midpupillary line of the the eye and the point intersecting a line drawn from the burr hole to a point between 1cm and 2cm posterior to EOM. Depth of catheter was 6.5-7cm. 3) hematoma at the posterior portion of putamen ; Direction of catheter was 15 degree laterally from the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between 2cm and 3cm posterior to EOM. Depth of catheter was 7-7.5cm. We have performed FHA of putaminal hemorrhage in 48 cases according to this guideline. All catheter were inserted exactly at the center of hematoma and average operation time was about 30 minutes. Conclusion : Our proposed guidelines for putaminal hemorrhage are considered to be safe and simple method with similar accuracy and rapid decompression compared with traditional stereotactic method. Main advantages of this technique were unnecessity of stereotactic frame application and less time requirement for hematoma removal.

  • PDF

Compared the Causes of Problematic Chemo-Ports According to the Types of Chemo-Ports(Valved, vs. Non-Valved) (Valve포트와 Non-Valved포트 사용에 따른 문제점의 비교 분석)

  • You, In-Gyu;Lim, Cheong-Hwan;Han, Beom-Hee;Jung, Hong-Ryang;Joo, Yeong-Cheol
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.35-41
    • /
    • 2011
  • Total implanted central venous port (TIAP, Chemoport) is widely used in oncology patients because it does not require external dressing and restricts patient activity. Chemoport only requires monthly flushes of heparinized saline to keep the patency of the catheter and probably less prone to infectious complications than tunneled catheter. Despite the extensive use of permanent central venous access in oncology patients, there are only few reports about clinical experience of the Groshong catheter. The purpose of this study is to compare the complication rate between the traditional open-ended (non-valved) chemoports and valved chemoports (Groshong catheter connected to TIAP). During 5 years (Jan 2006 to May 2010), 438 patients received chemoport insertion procedure in our interventional radiology department. Among them 30 patients was referred to our department for problematic chemoports. We compared the cause of problematic chemoports between two types of chemoports (valved, vs. non-valved). Valved chemoports had higher referral rates than non-valved chemoports. When there is a need to insert valved port, different method of insertion and maintenance procedure seems to be necessary. More than 20 ml of flusing with heparinized saline after blood sampling could be a good suggestion. Adequate care of chemoport is essential for long patency. Also following the guideline from the manufacturing company is necessary.