• Title/Summary/Keyword: Catheter insertion

Search Result 154, Processing Time 0.021 seconds

Reliability of Standardized Patients as Raters in Objective Structured Clinical Examination (객관 구조화 절차 기술 평가에서 채점자로서의 표준화환자의 신뢰도)

  • Son, Hee-Jeong;Moon, Joong-Bum;Lee, Hyang-Ah;Roh, Hye-Rin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.318-326
    • /
    • 2011
  • The purpose of this study is to investigate whether standardized patient(SP) can be used as a reliable examiner in Objective Structured Clinical Examination(OSCE). 4 SPs and 4 faculties who have more than 2 years experience of OSCE scoring were selected. For 1 assignment 2 members of faculty and 2 SPs were designated as raters. SPs were educated for assessing 2 technical skills, male Foley catheter insertion and wound dressing, for 8 hours (4 hours / day, each topic). The definition, method, cautions and complications for each of procedural skills were covered in the education. Theoretical lectures, video learning, faculty demonstration and practical training on mannequins were employed. The 8 raters were standardized for an hour with simulated OSCE scoring using previous videos on the day before the OSCE. Each assessment was composed of 14 checklists and 1 global rate. The allotted time for each assignment was 5minutes and for evaluation time 2 minutes per student. The evaluation from the faculty and SPs were compared and analyzed with the GENOVA program. The overall generalizability coefficient (G coefficient) was 0.839 from two cases of OASTS. The reliability of the raters was high, 0.946. The inter-rater agreement between faculty group and SP group was 0.949 for checklist and 0.908 for global rating. Therefore SPs can play a role of raters in OSCE for procedural skills, if they are given the appropriate training.

Development of Micro Wired pH Electrode for Real-Time Monitoring for Gastroesophageal Reflux (위식도 역류 실시간 모니터링 마이크로 와이어 pH 전극 개발)

  • Kim, Eung-Bo;Lee, Kyu-Jin;So, Sang-Kyun;Joung, Yeun-Ho;Park, Jung Ho;Kim, Nam Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.277-284
    • /
    • 2017
  • This paper presents an implantable pH measurement electrode for wireless gastroesophageal reflux measurement. Usually, gastroesophageal reflux is diagnosed by a catheter-type wire connection between the esophagus and the diagnostic device which brings many side effects such as restriction of daily living, pain, and discomfort in the nasal cavity and pharynx of patients. In order to solve these issues, researchers have been studied a wireless measurement method and a micro-sized pH electrode for human body insertion is necessary. Commercial glass packaged pH meter is formed by a sensing and a reference electrodes in a KCl solution. However, if the glass meter is inserted into the human body, there are risks of leakage of the solution, breakage of the glass package, injury of the body elements. Therefore, the solution should be solidified on the micro-sized noble metal wire which has a characteristic of biocompatible. After solidified wire fabrication, the designed meter was tested for feasibility of measurement and the result was well agreed with pH values of commercial pH meter. Potentials in pH 1 to 12 solution was measured to obtain the sensitivity of the sensor with linearity. And we have designed a simulation of gastroesophageal reflux with symptom frequency, interval, and duration time in pH 2 solution. The proposed sensor has capable to get the same potential for 24 measurements in 3 days, and it has sensed same pH values of 2 for one hour with every 10 minutes. Furthermore, the sensor was survived for 48 hours with reasonable potentials in the acid solution.

Laminotomy with Continuous Irrigation in Patients with Pyogenic Spondylitis in Thoracic and Lumbar Spine

  • Kim, Sung-Hyun;Lee, Jung-Kil;Jang, Jae-Won;Seo, Bo-Ra;Kim, Tae-Sun;Kim, Soo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.332-340
    • /
    • 2011
  • Objective : Pyogenic spondylitis often results in acute neurological deterioration requiring adequate surgical intervention and appropriate antibiotic treatment. The purpose of this study was to conduct an analysis of the clinical effect of continuous irrigation via laminotomy in a series of patients with pyogenic spondylitis in thoracic and lumbar spine. Methods : The authors conducted a retrospective investigation of 31 consecutive patients with pyogenic thoracic and lumbar spondylitis who underwent continuous irrigation through laminotomy from 2004 to 2008. The study included 22 men and 9 women, ranging in age from 38 to 78 years (mean 58.1 years). The average follow-up duration was 13.4 months (range, 8-34 months). We performed debridement and abscess removal after simple laminotomy, and then washed out epidural and disc space using a continuous irrigation system. Broad spectrum antibiotics were administered empirically and changed according to the subsequent culture result. Clinical outcomes were based on the low back outcome scale (LBOS), visual analogue scale (VAS) score, and Frankel grade at the last follow-up. Radiological assessment involved plain radiographs, including functional views. Results : Common predisposing factors included local injection for pain therapy, diabetes mellitus, chronic renal failure, and liver cirrhosis. Causative microorganisms were identified in 22 cases (70.9%) : Staphylococcus aureus and Streptococcus spp. were the main organisms. After surgery, LBOS, VAS score, and Frankel grade showed significant improvement in most patients. Spinal stability was maintained during the follow-up period, making secondary reconstructive surgery unnecessary for all patients, except one. Conclusion : Simple laminotomy with continuous irrigation by insertion of a catheter into intervertebral disc space or epidural space was minimally invasive and effective in the treatment of pyogenic spondylitis. This procedure could be a beneficial treatment option in patients with thoracolumbar spondylitis combined with minimal or moderate destructive change of vertebrae.

A Comparative Study on Effective Factors Related to Home Nursing Care in Hospital and Community-based Care in Korea (한국 가정간호사업의 유형별 비교분석)

  • Kim, Sung-Sil
    • Research in Community and Public Health Nursing
    • /
    • v.9 no.1
    • /
    • pp.181-199
    • /
    • 1998
  • This study was designed to examine Home Nursing Care in Hospital-based and Community-based programs. This study investigates actual conditions of nursing needs and demands of clients and their family and the state of home nursing services. We hope that this study will improve upon the current home nursing care system. In Korea Home-Nursing Care programs are still developing and only now becoming a part of the health care delivery system. The data was collected by a questionaire the clients developed and modified through literature review by this writer and through 10 nurses who are members of 4 hospital and 3 community- based agencies. In this study 173 clients were selected. The study lasted from Oct. 1997 to March of 1998. The results show that the average age was 64.3, years older than most women clients (63.0%), the average age of a caregiver was 50.9 years old and most were female(77%). Two types of agency clients with a significant difference between social conditions [25.7%] used some form of insurance; 54.3% had the spouse pay expenses; pay 58.5% son and daughters of Hospital-based agencies: patients of social workers were 24.0%, the highest in the community agency. The condition of patients was 63.2% of the foley and nelaton catheter insertion at hospital based agencies. The range of nursing services offered is one of the highest among the 34 kinds of servies including nasogastric tube management basic nursing, ROM exercise, bladder irrigation, wound and sore dressing. For an effective care service factors that disturb each program such as a non-cooperatative family as well as patients themselves need to be lessened. Further more, the following must be emphasized, supportive counsel 27.0%, steady care for patient, 13.3%maintain a sense of security(11.7%), dressing sores and nutrition(10.0%). Although there were a large number of home nursing care services in the community, policy changes have gathered momentum. Fortunately, the scope and level at legal support will be increased in the future. The program should intergrate and link the district or community together. A project to develop a community based home nursing system as soon as possible should be developed. In conclusion, home nursing care nurses training curriculum should be strengthened.

  • PDF

Comparison of Methods to Confirm the Cervical Epidural Space (경추 경막외강 확인법의 비교 연구)

  • Ok, Si Young;Chun, Hae Rim;Baek, Young Hee;Kim, Sang Ho;Kim, Soon Im;Kim, Sun Chong;Park, Wook;Song, Dan
    • The Korean Journal of Pain
    • /
    • v.22 no.2
    • /
    • pp.158-162
    • /
    • 2009
  • Background: The loss of resistance (LOR) method is most commonly used to identify the epidural space. This method is thought to rely on the penetration of the ligamentum flavum. Unfortunately the exact morphology of the ligamentum flavum is variable at different vertebral levels. Especially, it has been pointed out that the lower cervical ligamentum flavum may be discontinuous in the midline in up to 50% of patients. Thus, the LOR method may be inaccurate to confirm the cervical epidural space. The aim of this study is to determine which method is the safest and most exact for confirming the cervical epidural space. Methods: 100 adult, chronic renal failure patients who were undergoing an arteriovenous bridge graft for hemodialysis at the upper arm under cervical epidural anesthesia were recruited for this study. During the cervical epidural puncture, we identified the cervical epidural space by subjectively feeling the resistance with using a finger just through the ligamentum flavum, and we also used the drip infusion method, the loss of resistance method using air, and the hanging drop method. By using 5 grades, we classified the extent of whether or not the techniques were effective. Results: Using the drip infusion method, we identify the epidural space in all the patients as +/++ grade. The catheter insertion method was also successful in identifying those epidural spaces over a ${\pm}$ grade. The pseudo LOR was over ${\pm}$ grade in 47 patients. Conclusions: The combined LOR/hanging drop with drip infusion method is useful for confirming the cervical epidural space.

Minimally Invasive Treatment of Falciform Ligament Abscess in a 25-Day-Old Neonate: A Case Report (생후 25일 신생아에서 발생한 겸상인대 농양에 대한 최소 침습적 치료: 증례 보고)

  • Lee, Min Ah;Lee, Jeong Sub;Lee, Mu Sook;Kim, Seung Hyoung;Lee, Kyung Ryeol;Kim, Yoon Joo;Kang, Ki Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.5
    • /
    • pp.271-275
    • /
    • 2018
  • The falciform ligament is a hepatic suspensory ligament that extends from the umbilicus to the diaphragm, containing the ligamentum teres and a vestigial remnant of the umbilical vein. Among the rarely-occurring pathologies of the falciform ligament, which include ligament cyst, tumor, abnormal vascularization, and congenital ligament defect, a falciform ligament abscess is even more sporadic. Accordingly, the definitive diagnosis of the falciform ligament abscess is rather challenging and may easily be misinterpreted as an infected choledochal cyst or a liver abscess. We present a 25-day-old infant with the falciform ligament abscess, which developed after the umbilical venous catheter insertion and was successfully treated with percutaneous drainage and antibiotic administration.

A Study on the Implementation and Development of Image Processing Algorithms for Vibes Detection Equipment (정맥 검출 장비 구현 및 영상처리 알고리즘 개발에 대한 연구)

  • Jin-Hyoung, Jeong;Jae-Hyun, Jo;Jee-Hun, Jang;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.463-470
    • /
    • 2022
  • Intravenous injection is widely used for patient treatment, including injection drugs, fluids, parenteral nutrition, and blood products, and is the most frequently performed invasive treatment for inpatients, including blood collection, peripheral catheter insertion, and other IV therapy, and more than 1 billion cases per year. Intravenous injection is one of the difficult procedures performed only by experienced nurses who have been trained in intravenous injection, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Nurses who frequently perform intravenous injections may also make mistakes because it is not easy to detect veins due to factors such as obesity, skin color, and age. Accordingly, studies on auxiliary equipment capable of visualizing the venous structure of the back of the hand or arm have been published to reduce mistakes during intravenous injection. This paper is about the development of venous detection equipment that visualizes venous structure during intravenous injection, and the optimal combination was selected by comparing the brightness of acquired images according to the combination of near-infrared (NIR) LED and Filter with different wavelength bands. In addition, an image processing algorithm was derived to threshehold and making blood vessel part to green through grayscale conversion, histogram equilzation, and sharpening filters for clarity of vein images obtained through the implemented venous detection experimental module.

A Study on the Comparison of Detected Vein Images by NIR LED Quantity of Vein Detector (정맥검출기의 NIR LED 수량에 따른 검출된 정맥 이미지 비교에 관한 연구)

  • Jae-Hyun, Jo;Jin-Hyoung, Jeong;Seung-Hun, Kim;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.485-491
    • /
    • 2022
  • Intravenous injection is the most frequent invasive treatment for inpatients and is widely used for parenteral nutrition administration and blood products, and more than 1 billion procedures are used for peripheral catheter insertion, blood collection, and other IV therapy per year. Intravenous injection is one of the difficult procedures to be performed only by trained nurses with intravenous injection training, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Accordingly, studies on auxiliary equipment capable of visualizing the vein structure of the back of the hand or arm are being published to reduce errors during intravenous injection. This study is a study on the performance difference according to the number of LEDs irradiating the 850nm wavelength band on a vein detector that visualizes the vein during intravenous injection. Four LED PCBs were produced by attaching NIR filters to CCD and CMOS camera lenses irradiated on the skin to acquire images, sharpen the acquired images using image processing algorithms, and project the sharpened images onto the skin. After that, each PCB was attached to the front end of the vein detector to detect the vein image and create a performance comparison questionnaire based on the vein image obtained for performance evaluation. The survey was conducted on 20 nurses working at K Hospital.

Comparative Evaluation for the Effect of SUV's Due to a Residual Radio-activity Location Inside Vascular Insert Devices During PET/CT Scans (PET/CT 검사 시 혈관삽입기구 내 잔여 방사능 위치에 따른 표준섭취계수의 영향 비교 평가)

  • Sim, Woo Yong;Kim, Jung Yul;Cho, Suk Won;Oh, Shin Hyun;Lim, Han Sang;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.94-97
    • /
    • 2014
  • Purpose: Standardized uptake value (SUV) is a simple semi-quantitative method that can measure the ratio of the tissue radioactivity between the tumor and normal. SUV is commonly used in PET/CT, however, SUV is affected by various factor. The purpose of this study was to evaluate the impact of the residual activity on SUV depending on the location of catheter insertion device post injection. Materials and Methods: NEMA IEC Body Phantom was imaged using a Discovery 600 PET scanner. In 22 mm diameter sphere, the different activity of $^{18}F-FDG$ (7.4, 14.8, 22.2, 29.6, 37, 55.5 MBq) was filled and background was filled with $^{18}F-FDG$ (5.7 kBq/mL). We scaned the phantom on the assumption that the radioactivity in sphere was residual activity in insertion device. Simulation of PET was divided into three groups based on the location of sphere in Scan FOV (SFOV); inclusion, 1/2 inclusion and exclusion group. Results: Among three groups, the group of excluded sphere showed the highest SUV regardless of the amount of $^{18}F-FDG$ activity. In case of 7.4 MBq, average SUV of inclusion group, 1/2 inclusion and exclusion group was 0.780, 0.840 and 0.896 respectively. However, average SUV of 55.5 MBq showed 0.372, 0.460 and 0.508 with same order. Depend on residual radioactivity in the sphere and position of sphere, the SUV was different minimum of 10.4%, maximum of 62.8%. Conclusion: This study showed that SUV is underestimated as the residual radio-activity is increased. In addition, SUV was a changed according to the position of residual radio-activity. And among the position, exclusion group showed the difference of SUV was lowest. If we measure the residual radio-activity of inserting devices and radio-activity from extra-vasation in the patients, it seems to be more useful in clinical field.

  • PDF

A Clinical Characteristics of Systemic Candidiasis in Neonatal Intensive Care Unit : Comparison with Systemic Bacterial Infection (신생아 집중치료실 입원아에 있어서 전신성 칸디다증의 임상적 특징 : 전신성 세균 감염증과 비교)

  • Lim, Jung Hwa;Park, Kyung Pil;Kim, Jin Kyung;Kim, Heng Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.7
    • /
    • pp.847-854
    • /
    • 2002
  • Purpose : Long term hospitalized infants in neonatal intensive care units(NICUs) are prone to systemic infection. It is important to differentiate systemic candidiasis from systemic bacterial infection early in the course. Thus, in this study, we have compared clinical characteristics of systemic candidiasis and systemic bacterial infection, in premature low birth weight infants. Methods : Retrospective chart review of the medical records of 20 patients with systemic candidiasis and 23 patients with systemic bacterial infection was performed. Results : Among the risk factors of systemic candidiasis, total parenteral nutrition(TPN), the use of broad spectrum antibiotics, central catheter insertion, endotracheal intubation and the use of H2 blockers were more frequent in neonates with systemic candidiasis than neonates with systemic bacterial infection. Apnea with bradycardia developed more frequently in neonates with systemic candidiasis compared with systemic bacterial infection(75% vs 39%). In laboratory findings at symptom onset, seven cases(35%) of systemic candidal infections and two cases(9%) of systemic bacterial infections showed leukopenia and thrombocytopenia(P=0.03). Blood was the most frequent isolation site of candida and bacteria. Conclusion : In neonates with systemic candidiasis, apnea with bradycardia, pneumonia and thrombocytopenia were prone to develop more frequently. The use of TPN, antibiotics and central catheters was strongly associated with systemic candidiasis. Empirical treatment with antifungal agent should be considered in critically ill neonates with above findings.