• Title/Summary/Keyword: Catheter Length

Search Result 62, Processing Time 0.024 seconds

Characteristics and Mortality Risk Factors in Geriatric Hospital Patients visiting One Region-wide Emergency Department (일 권역응급의료센터를 방문하는 요양병원 환자들의 특성 및 사망 위험요인)

  • Kim, Kyoung Wan;Jang, Soongnang
    • Research in Community and Public Health Nursing
    • /
    • v.27 no.4
    • /
    • pp.327-336
    • /
    • 2016
  • Purpose: This study was to examine the clinical characteristics and mortality risk factors of geriatric hospital patients who visited one region-wide emergency department (ED). It's basically meant to develop criteria for the patient management of geriatric hospitals and to provide related information. Methods: A retrospective research study was implemented using electronic medical records. The subjects in this study included 484 geriatric hospital patients who were selected from among 15,994 patients that visited one region-wide ED between January 1, 2014, and December 31, 2015. Results: There were significant differences in death, a change for the better and no change for the better, which were results of treatment, according to the length of stay in hospital, hospitalization in a general ward, not having an operation or surgery, the presence or absence of malignant neoplasm, the insertion of foley catheter, intubation, ventilator and the insertion of central venous catheter. Conclusion: The results of this study suggest that a patient management system is necessary in geriatric hospitals and that competent healthcare workers who can properly respond to emergencies are required as well.

A Study on the Control of SMA Actuator for Smart Catheter (지능형 내시경용 SMA 엑츄에이터의 제어에 관한 연구)

  • Kim, Min-Sung;Park, Doo-Hwan;Park, Hyun-Choi;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.223-226
    • /
    • 2001
  • A SMA actuator fabricated in this paper generates the large force and it's structure is very simple. The SMA actuator was fabricated by small size with diameter of 4mm and length of 38mm and also it's actuations toward all the directions can be acquired because of three SMA springs which was fabricated with diameter of 1.2mm and 30 turns. We showed into applicability to smart catheter by analyzing accurately the dynamic characteristics such as heading angle, bending angle, force, displacement. For verifying control capacity of the fuzzy controller, we compared Fuzzy controller with PID controller by simulation.

  • PDF

A Study on the Fabrication of Micro Actuator for Smart Catheter using Shape Memory Alloy

  • Kim, Min-Sung;Park, Doo-Hwan;Sung, Sang-Koo;Jung, Jong-Won;Lee, Joon-Tark
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.130.3-130
    • /
    • 2001
  • A SMA actuator fabricated in this paper generates the large force and it´s structure is very simple. The SMA actuator was fabricated by small size with diameter of 9mm and length of 27mm and also it´s actuations toward all the directions can be acquired because of three springs which was fabricated with diameter of 2.4mm and 28 turns, We showed into applicability to smart catheter by analyzing accurately the dynamic characteristics such as heading angle, force, displacement.

  • PDF

Fabrication of Bending Actuator for Micro Active Catheter (초소형 작동형 내시경용 Bending 액츄에이터의 제작)

  • Lee, Kwang-Ho;Lee, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.615-617
    • /
    • 1997
  • This paper reports experimental results on the fabrication and analysis of millimeter-sized bending actuators for active catheter by use of the shape memory alloy spring and the flexible beam. The major components of micro actuator are shape memory alloy spring, stainless steel strip and two acryl links. The micro actuator with the diameter of 2.0 mm and the length of 25 mm has been fabricated and characterized for the possible application to the micro active catheters. The measured maximum angle is $60^{\circ}$ and the response time is 5 sec.

  • PDF

Continuous Stellate Ganglion Block for Raynaud'S Disease -A case report- (Catheter를 이용한 지속적 성상신경절 차단 경험 -증례 보고-)

  • Lee, Sang-Ryull
    • The Korean Journal of Pain
    • /
    • v.10 no.2
    • /
    • pp.278-280
    • /
    • 1997
  • Stellate ganglion block has been used to treat diseases such as peripheral vascular disease, sympathetic dystrophy, and various pain syndromes involving the head or arm. Raynaud's disease is a syndrome manifested by attacks of pallor, cyanosis, numbness and pain of the digits in response to cold or emotional change. I report one case who was given Stellate ganglion block using 18G teflon Catheter(4.5 cm in length) for Raynaud's disease. Continuous stellate ganglion block is more convinient to inpatient than repeated needle punctures and may reduce major complications and more useful to patient who needs continuous sympathetic block about one week duration.

  • PDF

A Study on the Fabrication of Micro Shape Memory Alloy Actuator for Smart Catheter (지능형 내시경용 초소형 형상기억합금 엑츄에이터의 제작에 관한 연구)

  • Kim, Min-Sung;Park, Doo-Hwan;Park, Hyun-Chol;Lee, Oh-Keol;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2411-2413
    • /
    • 2001
  • A SMA actuator fabricated in this paper generates the large force and it's structure is very simple. The SMA actuator was fabricated by small size with diameter of 9mm and length of 27mm and also it's actuations toward all the directions can be acquired because of three springs which was fabricated with diameter of 2.4mm and 28 turns. We showed into applicability to smart catheter by analysing accurately the dynamic characteristics such as heading angle, force, displacement.

  • PDF

The Effects of the Routine Mental Care with 10% Betadine on the Reduction of Catheter-Associated Urinary Tract Infection (베타딘을 사용한 외요도구 간호가 유치도뇨관 삽입환자의 요로감염에 미치는 영향)

  • 김필환;김영경
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.3
    • /
    • pp.614-624
    • /
    • 1999
  • The purpose of this study is to determine the effectiveness of routine meatal care on the reduction of catheter-associated urinary tract infection (UTI). The study was carried out on 30 patients with foley catheters in an intensive care unit of a general hospital from September 30 to April 1, 1998. Participants were both male and female. Data were collected from each patients by urinary specimen obtained with aseptic collection technique at the 3rd and the 7th day of the experiment after giving daily mental care with 10% betadine for periods ranging from 1st to 7th day to the experimental group but not to the control group. The results are as follows : 1. The rate of urinary tract infection within the experimental group was 0.0%, at the 3rd day of the experiment and 20.0% at the 7th day, but that of the control group was 20.0% at the 3rd day and 7% at the 7th day. There was a significant difference in urinary tract infection rate between the two groups at the 3rd day but no significant difference at the 7th day. 2. In the control group, the rate of UTI was 0.7% for male and 13.3% for female at the 3rd day, and 6.7% for male and 40% for female at the 7th day. In the experimental group, the rate of UTI was 6.7% for male and 0.0% for female at the 3rd day and 13.3% for male and 20% for female at the 7th day of experiment. There was a no significant difference between male and female. 3. By comparing the rate of UTI to the length of time the urinary catheter was in place, the longer the catheter was in place the more significant was the rate of UTI. 4. Microorganisms isolated in the control group were bacteria for 7 cases and fungus for 3 cases but in the experimental group, only 2 cases of bacteria were isolated.

  • PDF

A Study on the Contamination of Solution with Suction used in Tracheostomy Patients (기관지절개술 환자의 흡인시 사용하는 용액의 오염수준 변화 연구)

  • Lim Yun-Hee;Yu Kwang Soo
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.185-200
    • /
    • 1998
  • It has been contributed to public health that the hospital has multiplied in the aspect of number and has been a large size with development of modern medical science, meanwhile the problem of hospital infection is coming out seriously. Respiratory hospital infection among hospital infections develops, very commonly from patients having taken the operation of intubation or tracheostomy, which results from a big factor that the infection developed from medical appliances used for respiration aids, contamination of solution and infection of medical staff. This study is separated into four steps-the time to use normal saline and distillation water for storaging catheter which are the cause of the infection of solution to store distillation water and catheter, not to say the catheter used when the patient who should get tracheostomy operation takes suction. The purpose of this study is to offer the basic data which are needed to check contamination degree as time goes by and nurse intervention and grope for a new nursing intervention. The target of this study is hospitalized 1D an intensive care unit having 700 sickbeds which is located in IKSAN city and it targeted patients before 7 days passed after an operaion of a tracheostormy. Materials collected were analyzed by SPSS PC+ figures program. The result of this study were as follows ; 1. The gradual contamination levels of the normal saline used In suction are showing that colony increase in proportion to the length of time. 2. while colony increases in normal saline with the lapse of time. distillation water mixed with 5cc of potadine did not show any sign of the formation of colony from its preparation until it was used for 8 hours. 3. Such variables as the period of intubation insertion. the length of hospitalization in I.C.U. the age and the level of contamination of normal saline have no inter-relationship. Therefore. as the length of normal saline used In suction. the contamination level increases with the excelleration of the contamination speed. 4. Regarding the number of suction and the contamination level of the normal saline. We can observe correlation contamination level in the 3 step of suction(mean value:13.4) and the saline which was used for one hours(r=0.702. P=0.00l). four hours(r=0.694. P=0.00l). eight hours(r=0.488. P=0.029). Further we can observe contamination in the 4 step of suction (mean value: 17 .8) well as saline used for eight hours; [for one hours (r=0.64l. P=0.002). four hours (r=0.670. P=0.00l). eight hours (r=0.57 4. P=0.008)]. Thesedays clinics use normal saline by changing it. three times a day. however. the timing of saline change and the current suction methoed should be changed given the one hour used normal saline contamination number 79.850. Regarding the number of suction and the contamination lend of the normal saline.

  • PDF

Use of a Temporary Shunt as a Salvage Technique for Distal Extremity Amputations Requiring Repair by Vessel Grafting during Critical Ischemia

  • Ince, Bilsev;Dadaci, Mehmet;Altuntas, Zeynep
    • Archives of Plastic Surgery
    • /
    • v.43 no.6
    • /
    • pp.544-550
    • /
    • 2016
  • Background Although the use of temporary shunts in proximal extremity amputations has been reported, no study has described the use of temporary shunts in distal extremity amputations that require vein grafting. Moreover, the total volume of blood loss when temporary shunts are used has not been reported. The aim of this study was to investigate the applicability of a temporary shunt for distal extremity amputations requiring repair by vessel grafting with an ischemia time of >6 hours. This study also aimed to determine the total volume of blood loss when temporary shunts were used. Methods Patients who underwent distal major extremity replantation and/or revascularization with a vessel graft and who experienced ischemia for 6-8 hours between 2013 and 2014 were included in the study. A 6-Fr suction catheter was cut to 5 cm in length after the infusion of heparin, and secured with a 5-0 silk suture between the distal and the proximal ends of the artery. While bleeding continued, the bones were shortened and fixed. After the complete restoration of circulation, the arterial shunt created using the catheter was also repaired with a vein graft. Results Six patients were included in this study. The mean duration of ischemia was 7.25 hours. The mean duration of suction catheter use during limb revascularization was 7 minutes. The mean transfusion volume was 7.5 units. No losses of the extremity were observed. Conclusions This procedure should be considered in distal extremity amputations requiring repair by vessel grafting during critical ischemia.

Comparison of Pain Management Strategies to Reduce Opioid Use Postoperatively in Free Flap Breast Reconstruction: Pain Catheter versus Nerve Block in Addition to Refinements in the Oral Pain Management Regime

  • Andrea B. Stefansdottir;Luis Vieira;Arni Johnsen;Daniel Isacson;Andres Rodriguez;Maria Mani
    • Archives of Plastic Surgery
    • /
    • v.51 no.2
    • /
    • pp.156-162
    • /
    • 2024
  • Background Perioperative management in autologous breast reconstruction has gained focus in recent years. This study compares two pain management protocols in patients undergoing abdominal-based free flap breast reconstruction: a past protocol (PP) and a current protocol (CP)-both intended to reduce opioid consumption postoperatively. The PP entails use of a pain catheter in the abdominal wound and the CP consists of an intraoperative nerve block in addition to refinements in the oral pain management. We hypothesize that the CP reduces opioid consumption compared to PP. Methods From December 2017 to January 2020, 102 patients underwent breast reconstruction with an abdominal-based free flap. Two postoperative pain management strategies were used during the period; from December 2017 to September 2018, the PP was used which entailed the use of a pain catheter with ropivacaine applied in the abdominal wound with continuous distribution postoperatively in addition to paracetamol orally and oxycodone orally pro re nata (PRN). From October 2018 to January 2020, the CP was used. This protocol included a combination of intraoperative subfascial nerve block and a postoperative oral pain management regime that consisted of paracetamol, celecoxib, and gabapentin as well as oxycodone PRN. Results The CP group (n = 63) had lower opioid consumption compared to the PP group (n = 39) when examining all aspects of opioid consumption, including daily opioid usage in morphine milligram equivalents and total opioid usage during the stay (p < 0.001). The CP group had shorter length of hospital stay (LOS). Conclusion Introduction of the CP reduced opioid use and LOS was shorter.