• Title/Summary/Keyword: Catheter Insertion

Search Result 154, Processing Time 0.027 seconds

Eosinophilic Peritonitis (EP) Complicated with Continuous Ambulatory Peritoneal Dialysis (CAPD) (지속적 외래 복막투석 직후 발생하는 비감염성 호산구성 복막염)

  • Paek Kyung-Hoon;Jeon Yun-Ae;Min Jae-Hong;Park Kyung-Mi;Kim Jung-Su;Ha Il-Soo;Cheong Hae-Il;Choi Yong;Ko Kwang-Wook
    • Childhood Kidney Diseases
    • /
    • v.1 no.2
    • /
    • pp.117-122
    • /
    • 1997
  • Purpose : To clarify the clinical findings, laboratory findings and disease course of EP complicated with CAPD and to find out possible predisposing factors to EP. Methods : The medical records of 34 children who underwent CAPD at our hospital between Jan. '94 and Dec. '96 were retrospectively reviewed. The clinical features and laboratory findings of EP were analyzed, and several parameters were evaluated as predisposing factors of EP. Results : EP developed in 7(21%) out of 34 patients. The major symptom of EP was turbid peritoneal fluid without fever, abdominal pain or disturbance of drainage in all cases. The microbiologic culture studies of the peritoneal fluid resulted negative in all cases. Patients with peripheral blood eosinophilia before insertion of CAPD catheter had higher risk of EP than those without eosinophilia (P=0.002). And peripheral blood eosinophilia, noted after insertion of hemodialysis catheter in cases with previous hemodialysis before CAPD, showed significant correlation with the occurrence of EP (P=0.016), too. However, there was no significant correlation between peripheral blood eosinophilia noted after insertion of CAPD cathter and the occurrence of EP. Identification of eosinophils in peritoneal fluids was more accurate with cytospin analysis. Conclusions : An early and accurate diagnosis of EP in patients with CAPD can prevent unnecessary treatment of antibiotics. Peripheral blood eosinophilia before insertion of CAPD catheter is one of the predisposing factors of EP. And, cytospin analysis of peritoneal fluid is an accurate method for diagnosis of EP.

  • PDF

A Novel Implantable Cerebrospinal Fluid Reservoir : A Pilot Study

  • Byun, Yoon Hwan;Gwak, Ho Shin;Kwon, Ji-Woong;Kim, Kwang Gi;Shin, Sang Hoon;Lee, Seung Hoon;Yoo, Heon
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.5
    • /
    • pp.640-644
    • /
    • 2018
  • Objective : The purpose of this pilot study was to examine the safety and function of the newly developed cerebrospinal fluid (CSF) reservoir called the V-Port. Methods : The newly developed V-Port consists of a non-collapsible reservoir outlined with a titanium cage and a connector for the ventricular catheter to be assembled. It is designed to be better palpated and more durable to multiple punctures than the Ommaya reservoir. A total of nine patients diagnosed with leptomeningeal carcinomatosis were selected for V-Port insertion. Each patient was followed up for evaluation for a month after the operation. Results : The average operation time for V-Port insertion was 42 minutes and the average incision size was 6.6 cm. The surgical technique of V-Port insertion was found to be intuitive by all neurosurgeons who participated in the pilot study. There was no obstruction or leakage of the V-Port during intrathecal chemotherapy or CSF drainage. Also, there were no complications including post-operative intracerebral hemorrhage, infection and skin problems related to the V-Port. Conclusion : V-Port is a safe and an easy to use implantable CSF reservoir that addresses problems of other implantable CSF reservoirs. Further multicenter clinical trial is needed to prove the safety and the function of the V-Port.

Pain Response to Procedural Pain in Premature Infants (미숙아의 시술 관련 통증 반응)

  • Kim, Jung-Sook;Lee, Eun-Jung;Ham, Eun-Ha;Kim, Ji-Hyun;Yi, Young-Hee
    • Child Health Nursing Research
    • /
    • v.16 no.4
    • /
    • pp.352-359
    • /
    • 2010
  • Purpose: To explore premature infants' pain response to routine procedures in the neonatal intensive care unit (NICU). Methods: The participants were 56 preterm infants who showed 149 pain responses to 8 high frequency routine procedures which were evaluated using the Premature Infant Pain Scale (PIPS). Videotaped recording was used for data collection. Data were analyzed with descriptive analysis, paired t-test, and Pearson's correlation coefficient. Results: PIPS scores for each procedure were as follows; for removal of central catheter dressing, 6.17 (2.04), venous sampling, 6.12 (2.87), intramuscular injection, 6.05 (2.38), insertion of a peripheral line, 5.38 (2.16), insertion of feeding tube, 4.40 (1.34), heel stick, 4.33 (1.23), insertion of central line, 4.00 (2.12), and endotracheal suctioning, 2.90 (1.25). PIPS score was negatively correlated with gestational age (r=-.218, p=.007) and birth weight (r=-.249, p=.002) among general characteristics of the infants. Conclusion: The majority of 8 routine procedures were found to be painful for premature infants in the NICU. Therefore, adequate pain management related to procedures should be provided to premature infant in the NICU.

Study on Prolonging Peripheral Intravenous Catheter Indwell Time Based on Phlebitis Rate (정맥염 발생률에 근거한 말초 정맥관의 정규교환 시기 연장에 대한 연구)

  • Yoon, Hee Sook;Park, Mee Ah;Park, Eun Jung;Choi, Jhin Hee;Kim, Mi Young;Lim, Ji Mi;Lee, Seung Ja;Lee, Chang Kwan
    • Journal of Korean Clinical Nursing Research
    • /
    • v.16 no.1
    • /
    • pp.145-153
    • /
    • 2010
  • Purpose: The purpose of this study was to re-assess the replacement time intervals of Peripheral Intravenous Catheters (PICs) by investigating phlebitis rates according to the indwelling times of PICs. Methods: The study was conducted on 340 patients in S hospital by an IV team. After PIC insertion, IV team members evaluated once a day. The PICs were replaced every 96 hours, and let them in situ when the patients wanted to, in the absence of any sign of complications, from 97 hours to 153 hours. Results: Total phlebitis rate was 19.6%. There were no significantly different factors associated with the occurrence of phlebitis. The incidence rates of phlebitis were 12.6% and 7.0% before and after 72 hours of PIC insertion, and recorded zero after 96 hours. Conclusion: It would be recommendable to maintain PIC in situ for longer than 72 hours if there is no sign of complication such as phlebitis in close monitoring of PIC insertion site.

The Management of Malignant Ascites in Terminal Cancer Patients (말기 암환자에서 악성 복수의 치료)

  • Kim, Sun-Hyun;Yeom, Chang-Hwan
    • Journal of Hospice and Palliative Care
    • /
    • v.11 no.3
    • /
    • pp.131-135
    • /
    • 2008
  • The management of malignant ascites can be problematic for physicians and patients. The mass effect of ascites can cause symptoms of painful abdominal distention, nausea, vomiting, and bowel obstruction. Also patients often complain of shortness of breath and lower extremity edema. These symptoms not only are distressing, but also adversely affect quality of life in terminal cancer patients. We will introduce you how to treat ascites based on our cases.

  • PDF

Epidural Hematoma following Continuous Epidural Catheterization for Postherpetic Neuralgia -A case report- (대상포진후 신경통 치료를 위한 지속적 경막외 차단후 발생한 경막외 혈종 -증례 보고-)

  • Cho, Dong-Kyu;Lee, Kang-Chang;Kim, Tai-Yo
    • The Korean Journal of Pain
    • /
    • v.10 no.1
    • /
    • pp.127-130
    • /
    • 1997
  • A 67-year old man with a history of cardiac disease underwent epidural catheterization for pain control of postherpetic neuralgia. Patient had severe back pain and pus discharge at catheter insertion site after dischange from medical part. Patient received anticoagulant therapy with $Aspirin^{(R)}$ and $Coumadin^{(R)}$ prescribed for 15 days in medical part. Magnetic resonance imaging(MRI) showed a diffuse $T_{4-7}$ anterior epidural mass compressing the spinal cord. Emergency surgical exploration revealed a thoracic epidural hematoma without abcess formation. Operation was successful and patient recovered satisfactory without any sequelae.

  • PDF

Educational Simulation Videos for Performing Resuscitative Endovascular Balloon Occlusion of the Aorta

  • Chang, Sung Wook;Kim, Dong Hun;Chang, Ye Rim
    • Journal of Trauma and Injury
    • /
    • v.33 no.3
    • /
    • pp.140-143
    • /
    • 2020
  • Resuscitative endovascular balloon occlusion of the aorta (REBOA) has been accepted as an adjunct procedure for non-compressible torso hemorrhage in patients with hemorrhagic shock. With appropriate indications, REBOA should be performed for resuscitation regardless of the physician's specialty. Despite its effectiveness in traumatized patients with hemorrhagic shock, performing REBOA has been challenging due to physicians' lack of experience. Even though training in endovascular skills is mandatory, many physicians cannot undergo sufficient training because of the limited number of endovascular simulation programs. Herein, we share simulation video clips, including those of a vascular circuit model for simulation; sheath preparation; long guidewire and balloon catheter preparation; ultrasound-guided arterial access; sheath insertion or upsizing; and balloon positioning, inflation, and migration. The aim of this study was to provide educational video clips to improve physicians' endovascular skills for REBOA.

A Case of Complication of Expandible Metallic Stent with Endobronchial Stenosis (결핵성 기관지 협착시 팽창성 금속 스텐트 시행후 발생한 육아종 형성 1예)

  • Lim, Seong-Hee;You, Kwan-Hee;Lee, Yong-Chul;Rhee, Yang-Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.1
    • /
    • pp.47-50
    • /
    • 1994
  • To maintain an adequate airway in a patient with tracheobronchial narrowing coming from various causes, prosthetic tracheobronchial stents provide palliative treatment for narrowed airways where surgical resection is inadvisable. After insertion, previous reported complications were granuloma formation, dysphagia, suction catheter entrapment and fatal massive hemoptysis. We report, a case of complication associated with expandible metallic stent with endobronchial stenosis due to tuberculosis.

  • PDF

Effect of Consecutive Superovulation to Korean Native Cows and Holstein Milk Cows

  • Park, S. J.;I. S. Ryu;Park, S. H.;G. Y. Chung;S. R. Cho;Lee, J. H.;D. S. Son
    • Proceedings of the KSAR Conference
    • /
    • 2004.06a
    • /
    • pp.254-254
    • /
    • 2004
  • The aim of this study was two purpose: to compare recovery of embryos/follicle number from superovulated Holsteins(H) and Korean Native Cows(KNC) by flushing the uterine horns through insertion of the catheter and to evaluate the hormonal and superovulatory response to estradiol benzoate(EB) treatment prior to superovulation. (omitted)

  • PDF

Comparison on the Error Rates of Calibration Modes in Intervention (인터벤션에서 Calibration Mode에 대한 오차율 비교)

  • Kong, Chang gi;Ryu, Young hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.619-626
    • /
    • 2020
  • This study aimed to identify the error rates in Catheter Calibration Mode, Auto Calibration Mode, and Segment Calibration Mode among many calibration modes as a quantitative evaluation tool used for predicting the diameter and length of balloon or stent in percutaneous intravascular balloon dilatation or stent insertion. Our experiment was conducted with Copper Wire of 2 mm × 80 mm (diameter × length) manufactured elaborately for quantitative evaluation in calibration and Metal Ball of 5, 10, 15, 30, and 40 mm and Acryl Phantom of 25 mm, 50 mm, 75mm, 100 mm, 125 mm, 150mm, 175 mm, and 200 mm. At each height, subtraction images were acquired with a cineangiograph and Stenosis Analysis Tool as a software provided by the equipment company was used for measurement. To evaluate the error rates in Catheter Calibration Mode, Copper Wire was put on each acryl phantom before shooting. Copper Wire of 2 mm in diameter was set as a diameter for catheter, and Copper Wire of 8 mm in length was measured with Multi-segments. As a result, the error rates appeared at 1.13 ~ 5.63%. To evaluate the error rates in Auto Calibration Mode, the height of acryl was entered at each height of acryl phantom and the length of 8 mm Copper Wire was measured with Multi-segments and as a result, the error rates appeared at 0 ~ 0.26%. To evaluate the error rates in Segment Calibration Mode, each metal ball on the floor of table was calibrated and the length of 8 mm Copper Wire on each acryl phantom was measured and the length of 8 mm Copper Wire depending on the changes of acryl phantom height was measured with Mutli-segments and as a result, the error rates appeared at 1.05 ~ 19.04%. And in the experiment on OID changes in Auto Calibration Mode, the height of acryl phantom was fixed at 100mm and OID only changed within the range of 450 mm ~ 600 mm and as a result, the error rates appeared at 0.13 ~ 0.38%. In conclusion, it was found that entering the height values in Auto Calibration Mode, among these Calibration Modes for evaluating quantitative vascular dimensions provided by the software was the calibration method with the least error rates and it is thus considered that for calibration using a metal ball or other objects, putting them in the same height as that of treatment sites before calibrating is the method that can reduce the error rates the most.