• Title/Summary/Keyword: Casualties

Search Result 784, Processing Time 0.025 seconds

Aspect of the chief of state guard EMP (Electro Magnetic Pulse) protection system for the consideration (국가원수 경호적 측면에서의 EMP(Electro Magnetic Pulse) 방호 시스템에 대한 고찰)

  • Jung, Joo-Sub
    • Korean Security Journal
    • /
    • no.41
    • /
    • pp.37-66
    • /
    • 2014
  • In recent years, with the development of computers and electronics, electronics and communication technology in a growing and each part is dependent on the cross-referencing makes all electronic equipment is obsolete due to direct or indirect damage EMP. Korea and the impending standoff North Korea has a considerable level of technologies related to the EMP, EMP weapons you already have or in a few years, the development of EMP weapons will complete. North Korea launched a long-range missile and conducted a nuclear test on several occasions immediately after, when I saw the high-altitude nuclear blackmail has been strengthening the outright offensive nuclear EMP attacks at any time and practical significance for the EMP will need offensive skills would improve. At this point you can predict the damage situation of Korea's security reality that satisfy the need, more than anything else to build a protective system of the EMP. The scale of the damage that unforeseen but significant military damage and socio-economic damage and fatalities when I looked into the situation which started out as a satellite communications systems and equipment to attack military and security systems and transportation, finance, national emergency system, such as the damage elsewhere. In General, there is no direct casualties reported, but EMP medical devices that rely on lethal damage to people who can show up. In addition, the State power system failure due to a power supply interruption would not have thought the damage would bring State highly dependent on domestic power generation of nuclear plants is a serious nuclear power plant accident in the event of a blackout phenomenon can lead to the plant's internal problems should see a forecast. First of all, a special expert Committee of the EMP, the demand for protective facilities and equipment and conduct an investigation, he takes fits into your budget is under strict criteria by configuring the contractors should be sifting through. He then created the Agency for verification of performance EMP protection after you have verified the performance of maintenance, maintenance, safety and security management, design and construction company organized and systematic process Guard facilities or secret communications equipment and perfect for the EMP, such as protective equipment maneuver system should take.

  • PDF

A Comparative Study of Rain Intensities Retrieved from Radar and Satellite Observations: Two Cases of Heavy Rainfall Events by Changma and Bolaven (TY15) (장마와 볼라벤(태풍 15호)에 동반된 집중호우 레이더관측과 위성관측 자료로부터 도출한 강우강도의 비교연구)

  • Lee, Dong-In;Ryu, Chan-Su
    • Journal of the Korean earth science society
    • /
    • v.33 no.7
    • /
    • pp.569-582
    • /
    • 2012
  • The heavy rainfalls caused large property damages and human casualties. For example, Changma caused 0.25 billion dollars in damages and 57 deaths and 112 missing by accompanying the torrentially convective heavy rainfall in Seoul, 2011. In addition, TY15 (Bolaven) caused a small damage by bringing a relatively small amount of rainfall and strong wind in Gwanju, 2012. The investigation and analyses of these mesoscale processes of rainfall events for different physical properties using KLAPS for weather environments of the above cases were performed. These typical and ideal meoscale systems by better and more favorable cloud systems were chosen to retrieve rain intensity from Radar and Chullian data. The quantitative rain intensities of Radar and Chullian differ greatly from the ground-based gauge values with underestimating over 50 mm/hr at the peak time of hourly maximum rain intensity about over than 85 mm/hr. However, the Radar rain intensity demonstrated approximately lower than 35 mm/hr, and the Chullian rain intensity less than 60 mm/hr for Changma in Seoul, 2011. For typhoon (TY15, Bolaven) in Gwangju, similarly, the quantitative rain intensities of Radar and Chullian differ from the ground-based gauge values. At the peak time, the hourly maximum rain intensity of ground-based gauge was more than 15 mm/hr. However, the Radar rain intensity showed lower than 5 mm/hr, and the Chullian rain intensity lower than 10 mm/hr. Regarding the above two cases of typhoon and Changma, even though Radar and Chullian rain intensities have been underestimated when compared to the ground-based rain intensity, the distributions of time scale features of both Radar and Chullian rain intensities still delineated a similar tendency of rain intensity distribution of the ground-based gauge data.

A Study Consequence Management System of the Terrorism (테러리즘의 대응관리체제에 관한 고찰 - "9. 11 테러"를 중심으로 -)

  • Kim, Yi-Soo;Ahn, Byung-Soo;Han, Nam-Soo
    • Korean Security Journal
    • /
    • no.7
    • /
    • pp.95-124
    • /
    • 2004
  • It can be said that 'the September 11th Terrorist Attacks' in 2001 were not only the indiscriminate attacks on innocent people but also the whole - political, economical and military - attacks on human life. Also, 'the September 11th Terrorist Attacks' can be regarded as the significant events in the history of world, which were on the peak of the super-terrorism or new-terrorism that had emerged from the 1980s. However, if one would have analysed the developments of terrorism from the 1970s, they could have been foreknown without difficulty. The finding from this study can be summarized as the followings, First, in spite that the USA responsive system against terrorism had been assessed as perfect before 'the September 11th Terrorist Attacks', the fragilities were found in the aspects of the response on the new-terrorism or super-terrorism. The previous responsive system before 'the September 11th Terrorist Attacks' had the following defects as the followings: (1) it was impossible to establish the integrated strategy, because the organizations related to the response against terrorism had not integrated; (2) there were some weakness to collect and diffuse the informations related to terrorism; (3) the security system for the domestic airline service in USA and the responsive system of air defense against terrors on aircraft were very fragile. For these reasons, USA government established the 'Department of Homeland Security' of which the President is the head so that the many organizations related to terrorism were integrated into a single management system. And, it legislated a new act to protect security from terrors, which legalized of the wiretapping in spite of the risk of encroachment upon personal rights, increased the jail terms upon terrorists, froze the bank related to terrorist organization, and could censor e-mails. Second, it seem that Korean responsive system against terrors more fragile than that of USA. One of the reasons is that people have some perception that Korea is a safe zone from terrors, because there were little attacks from international terrorists in Korea. This can be found from the fact that the legal arrangement against terrorism is only the President's instruction No. 47. Under this responsive system against terrorism dependent on only the President's instruction, it is expected that there would be a poor response against terrors due to the lack of unified and integrated responsive agency as like the case of USA before 'the September 11th Terrorist Attacks'. And, where there is no legal countermeasure, it is impossible to expect the binding force on the outside of administrative agencies and the performances to prevent and hinder the terrorist actions can not but be limited. That is to say, the current responsive system can not counteract effectively against the new-terrorism and super-terrorism. Third, although there were some changes in Korean government's policies against terrorism. there still are problems. One of the most important problems is that the new responsive system against terrorism in Korea, different from that of USA, is not a permanent agency but a meeting body that is organized by a commission. This commission is controled by the Prime Minister and the substantial tasks are under the National Intelligence Service. Under this configuration, there can be the lack of strong leadership and control. Additionally, because there is no statute to response against terrorism, it is impossible to prevent and counteract effectively against terrorism. The above summarized suggests that, because the contemporary super-terrorism or new-terrorism makes numerous casualties of unspecified persons and enormous nationwide damages, the thorough prevention against terrorism is the most important challenge, and that the full range of legal and institutional arrangements for the ex post counteraction should be established. In order to do so, it is necessary for the government to make legal and institutional arrangements such as the permanent agency for protection from terrorism in which the related departments cooperates with together and the development of efficient anti-terror programs, and to show its willingness and ability that it can counteract upon any type of domestic and foreign terrorism so that obtain the active supports and confidence from citizens.

  • PDF

Islamist Strategic Changes against U.S. International Security Initiative (미국(美國)의 대외안보전략(對外安保戰略)에 대응한 이슬람Terrorism의 전술적(戰術的) 진화(進化))

  • Choi, Kee-Nam
    • Korean Security Journal
    • /
    • no.14
    • /
    • pp.517-534
    • /
    • 2007
  • Since the beginning of human society, there have always been struggles and competitions for survival and prosperity, terrorism is not a recent phenomenon, however in modern times it has progressed to reflect the advances in civilization and power structures. At the time of the 9.11 terrorist attacks in the U.S. A., a new world order was in the process of being established after the breakdown of the Cold War era. The attacks drove both the Western and the Islamic worlds into heightened fear of terrorism and war, which threatened the quality of life of the whole mankind. Through two war campaigns against the Islamic world, it seems the U.S. has been pushing its own militaristic security road map of the Greater Middle East democratic initiative, justifying it as a means to retaliate and eradicate the terrorist threats towards themselves. However, with its five-year lopsided victories that cost the nation almost four thousand military casualties, and the war expenses that could match the Vietnam war, the U.S. does not yet seem to be totally emancipated from the fears of terrorism. Terrorism, in itself, is a means of resisting forced rules a form of alternative competition by the weak against the strong, and a way of expressing a dismissive response against dictatorial ideas or orders which allow for no normal changes. Intrinsically, the nature of terrorism is a reaction opposing power logics. Confronted with the absolute military power of the U.S., the Islamic strategies of terrorism have begun to rapidly evolve into a new stage. The new strategies take advantage of their civilization and circumstances, they train and inspire their front-line fighters on the Internet, and issue their orders through the clandestine network of the Al Qaeda operatives. These spontaneously generated strategies have been gained speed among the second, and third Islamic generations, many of whom are now spread throughout western societies. This represents a failure of the power-driven, one-sided overseas security initiatives by the U.S., and is creating a culture of fear and distrust in western societies. It is feared that the U.S. war campaigns have made the clash of religions far worse than before, and may ever lead to global ethnic separations and large-scale population movements. Eventually, it may result in the terrorist groups, enlarged and secretly supported by the huge sums of oil money, driving all mankind into a series of irreparable catastrophes.

  • PDF

Experimental Evaluation of Bi-directionally Unbonded Prestressed Concrete Panel Impact-Resistance Behavior under Impact Loading (충돌하중을 받는 이방향 비부착 프리스트레스트 콘크리트 패널부재의 충돌저항성능에 대한 실험적 거동 평가)

  • Yi, Na-Hyun;Lee, Sang-Won;Lee, Seung-Jae;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.5
    • /
    • pp.485-496
    • /
    • 2013
  • In recent years, frequent terror or military attacks by explosion or impact accidents have occurred. Examplary case of these attacks were World Trade Center collapse and US Department of Defense Pentagon attack on Sept. 11 of 2001. These attacks of the civil infrastructure have induced numerous casualties and property damage, which raised public concerns and anxiety of potential terrorist attacks. However, a existing design procedure for civil infrastructures do not consider a protective design for extreme loading scenario. Also, the extreme loading researches of prestressed concrete (PSC) member, which widely used for nuclear containment vessel, gas tank, bridges, and tunnel, are insufficient due to experimental limitations of loading characteristics. To protect concrete structures against extreme loading such as explosion and impact with high strain rate, understanding of the effect, characteristic, and propagation mechanism of extreme loadings on structures is needed. Therefore, in this paper, to evaluate the impact resistance capacity and its protective performance of bi-directional unbonded prestressed concrete member, impact tests were carried out on $1400mm{\times}1000mm{\times}300mm$ for reinforced concrete (RC), prestressed concrete without rebar (PS), prestressed concrete with rebar (PSR, general PSC) specimens. According to test site conditions, impact tests were performed with 14 kN impactor with drop height of 10 m, 5 m, 4 m for preliminary tests and 3.5 m for main tests. Also, in this study, the procedure, layout, and measurement system of impact tests were established. The impact resistance capacity was measured using crack patterns, damage rates, measuring value such as displacement, acceleration, and residual structural strength. The results can be used as basic research references for related research areas, which include protective design and impact numerical simulation under impact loading.

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.

Coverage Patterns of the Internet News Media on the'US-Iraq War'and its Discourse Structure: With an emphasis of analysing time and discourse structure of the 'Oh My News' news items (인터넷 미디어의 '미국.이라크' 전쟁 보도 경향과 담론구조: <오마이뉴스>보도의 시간구조와 담론구조 분석을 중심으로)

  • Baek, Seon-Gi
    • Korean journal of communication and information
    • /
    • v.33
    • /
    • pp.115-167
    • /
    • 2006
  • The purpose of this study was to investigate coverage patterns of the Korean internet news media on 'US-Iraq War' and its meaning and discourse structure. The internet news media was recently established and become a popular news media to compete with old news media in Korea. The author selected the 'Oh My News' as a representative internet news media for his analysis, and collected its news items from Mar. 20, 2003 to Dec. 17, 2003. on the basis of 4 different phases of the war. He analysed the whole of news items with various semiotic and discourse analytic methods, especially applying for Bell's concepts of time and discourse structure. As a result of this study, first of all, it was found that the 'Oh My News' tended to cover this war so different ways as the old news media did. It did not pay attention to the procedure of war, especially, battlefields, fighting between US and Iraq, damages and casualties. But, instead, it paid attention to many doubts about intention of US government and the President, Bush, dichotomous shift between pro-America and anti-America, rightness of dispatching Korean army into Iraq, etc. Secondly, it functioned as a kind of alternative media to speak up different voices comparing with those of old media. It tended to suggest different perspectives and opinions, while the old media tended to follow American perspectives and opinions. Thirdly, it became as a kind of new media setting agendas for this war in Korean society. It played a very important role for setting agendas for various issues related with this war. In conclusion, the internet news media has recently become a kind of new news media for suggesting alternative or different opinions, setting agendas, initiating discourses, etc., even though it still has may problems of becoming so called orthodox news media.

  • PDF

Evaluating Impact Resistance of Externally Strengthened Steel Fiber Reinforced Concrete Slab with Fiber Reinforced Polymers (섬유 보강재로 외부 보강된 강섬유 보강 콘크리트 슬래브의 충격저항성능 평가)

  • Yoo, Doo-Yeol;Min, Kyung-Hwan;Lee, Jin-Young;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.293-303
    • /
    • 2012
  • Recently, as construction technology improved, concrete structures not only became larger, taller and longer but were able to perform various functions. However, if extreme loads such as impact, blast, and fire are applied to those structures, it would cause severe property damages and human casualties. Especially, the structural responses from extreme loading are totally different than that from quasi-static loading, because large pressure is applied to structures from mass acceleration effect of impact and blast loads. Therefore, the strain rate effect and damage levels should be considered when concrete structure is designed. In this study, the low velocity impact loading test of steel fiber reinforced concrete (SFRC) slabs including 0%~1.5% (by volume) of steel fibers, and strengthened with two types of FRP sheets was performed to develop an impact resistant structural member. From the test results, the maximum impact load, dissipated energy and the number of drop to failure increased, whereas the maximum displacement and support rotation were reduced by strengthening SFRC slab with FRP sheets in tensile zone. The test results showed that the impact resistance of concrete slab can be substantially improved by externally strengthening using FRP sheets. This result can be used in designing of primary facilities exposed to such extreme loads. The dynamic responses of SFRC slab strengthened with FRP sheets under low velocity impact load were also analyzed using LS-DYNA, a finite element analysis program with an explicit time integration scheme. The comparison of test and analytical results showed that they were within 5% of error with respect to maximum displacements.

A Study on the Impact of Human Factors for the Students Pilot's in ATO -With Respect to Korea Aviation Act and ICAO Human Factors Training Manual- (항공법규에 의거 지정된 조종사 양성 전문교육기관의 학생조종사에 대한 휴먼팩터 영향 연구)

  • Lee, Kang-Seok
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.26 no.2
    • /
    • pp.149-179
    • /
    • 2011
  • Statistics of aviation accident in Korea show that safety level of training flights is high. However, more than 80% of aviation accidents happen owing to human factors. And because most reasons of them are concerned with pilot error, it is very important for student pilots who will transport a lot of passengers to develop the knowledge of safety and abilities of risk management for preventing accidents. In this study, in order to investigate the Human Factors which affect safety in training student pilots for flight, verified the correlationbetween experiences of accident, the differences according to the experience level of training flight and the differences between college student pilots and ordinary student pilots on the basis of human factors that composes the SHELL models. For the study, Using SPSS 17.0, conducted Correlation Analysis, Analysis of Variance(ANOVA) and t-test. To sum up the result of this study, student pilot's ability and equipment in the cockpit are the important factors for safety when pilots are training flight. Also the analysis of the differences between human factors according to the characters of student pilots' groups shows that college student pilots are affected by immanent factors and organizational cultures. So far, there haven't been any accidents which is related with human casualties when training at the ATO(Approved Training Organization). But accidents can occur at any time and anywhere. Especially the human factors which comprises most of aviation accident have a wide reach and are impossible to be eliminated, therefore, it is best to minimize them. Because ATO is the starting point to lead the aviation industry of Korea, we will have to be aware of problems and improve education/training of human factors.

  • PDF

An Experimental Study on the Pore Structure and Thermal Properties of Lightweight Foamed Concrete by Foaming Agent Type (기포제 종류에 따른 경량기포콘크리트의 기포구조 및 열적특성에 관한 실험적 연구)

  • Kim, Jin-Man;Choi, Hun-Gug;Park, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.63-73
    • /
    • 2009
  • Recently, the use of lightweight panels in building structures has been increasing. Of the various lightweight panel types, styrofoam sandwich panels are inexpensive and are excellent in terms of their insulation capacity and their constructability. However, sandwich panels that include organic material are quite vulnerable to fire, and thus can numerous casualties in the event of a fire due to the lack of time to vacate and their emission of poisonous gas. On the other hand, lightweight foamed concrete is excellent, both in terms of its insulation ability and its fire resistance, due to its Inner pores. The properties of lightweight concrete is influenced by foaming agent type. Accordingly, this study investigates the insulation properties by foaming agent type, to evaluate the possibility of using light-weight foamed concrete instead of styrene foam. Our research found thatnon-heating zone temperature of lightweight foamed concrete using AP (Aluminum Powder) and FP (animal protein foaming agent) are lower than that of light-weight foamed concrete using AES (alkyl ether lactic acid ester). Lightweight foamed concrete using AES and FP satisfied fire performance requirements of two hours at a foam ratio 50, 100. Lightweight foamed concrete using AP satisfied fire performance requirements of two hours at AP ratio 0.1, 0.15. The insulation properties were better in closed pore foamed concrete by made AP, FP than with open pore foamed concrete made using AES.