Effect of Harmonics on the Cast-Resin Transformer Life Cycle (고조파가 몰드변압기 수명에 미치는 영향분석)

  • Kang, Chang-Seob;Lee, Hong-Gee;Lee, Un-Cheol;Yoon, Duck-Ryang
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.118-120
    • /
    • 1996
  • We've been reported recently that increase of installing big power converting equipment which makes harmonics result in damage on transformer for incoming and load. Specially, harmonics that cause overheat and aging is severer in cast-resin transformer a kind of dr type than in oil one. The goal of this paper is to prove the process for aging of transformer that result from harmonics in according to both of theory and actual measurement on site. And we introduce diagnostic methods to estimate aging condition of cast-resin transformer in accordance with simulation.

  • PDF

A Tie-plate Shape Optimization of 24MVA Cast Resin Transformer for Reduction of Stray Loss (24MVA 몰드 변압기의 손실저감을 위한 Tie-Plate의 형상 최적설계 연구)

  • Kim, Yong-Bae;Shin, Pan-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.55-61
    • /
    • 2014
  • This paper presents a method to reduce the stray loss of core Tie-Plate of distribution power transformer. The method combines a 3-dimensional FEM with PSO(Particle Swarm Optimization) algorithm to determine the shape of the Tie-Plate that minimizes eddy current and flux-leakage losses. To verify the method a 24MVA distribution(cast-resin) transformer was simulated using one objective function and two design variables with some constraints. The final optimized Tie-Plate has nine($3{\times}3$) slots of 10mm width, 15mm thickness and 25mm distance. After four iterations, the Tie-Plate loss was reduced to about 21 % of the original.

Measurement and Analysis of Insulation Detects of Cast-resin Transformers using Antenna (안테나를 이용한 몰드변압기 절연결함 측정기법 연구)

  • Choi, Myeong-Il;Kim, Jae-Jin;Han, Ga-Ram;Jeon, Jeong-Chay;Lee, Hyun-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1937-1942
    • /
    • 2016
  • Unlike oil immersed transformers, cast-resin transformers have the solid insulator 'epoxy resin' in sealed structure. Therefore, they reveal a lot of limitations in checking aging conditions and predicting an accident. This study analyzed the characteristics of Cast-resin transformers by the measurement distance and measurement sensitivity with a corona defect sample, using antenna sensor. Therefore, the experiment has proven that the antenna sensor-based measurement method proposed in this study is able to detect the insulation defect location of the cast-resin transformer, unlike conventional measurement methods. It is expected that the result of this study will be used to develop a new type of measuring method in order to measure insulation defects and to use in safety inspection of domestic cast-resin transformers.

Analysis of Heat-transfer on Winding composed with Epoxy-resin (에폭시수지로 몰딩된 권선의 열전달 특성 연구)

  • 이현진;허창수;조한구;이기택;서유진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.402-405
    • /
    • 2002
  • This paper presented the characteristic of Heat-transfer on the winding composed with Epoxy-resin in a 50 kVA cast-resin dry type transformer The resin cast transformer is used widely in supplying electricity systems. However, to know the thermal characteristics of that is very useful in designing, manufacturing, and maintaining, there is no pertinent method to calculate this. In this paper, Based on the results of the physical characteristics and the simulation by commercial software using FEM method, we established the Prototype Model for this. According to that Model, an analysis on a variation of the hottest spot temperature was discussed as a function of thermal conductivity for the individual windings composed with Epoxy-resin. The thermal conductivity of the individual windings with reference to upper way was discussed.

  • PDF

Diagnosis of Insulation Deterioration in Cast Resin Transformer Using Method of AE Measurement (음향 방출 측정법을 이용한 몰드변압기 열화진단)

  • Lee, Sang-Woo;Gu, Kyung-Chul;Kim, Seung-Gyu;Kim, In-Sik;Lee, Dong-In;Kim, Ki-Chai;Park, Won-Zoo;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1936-1938
    • /
    • 2000
  • In this paper, a frequency spectra of AE (acoustic emission) signals detected from the partial discharges of an epoxy resin void and a cast resin transformer in operating were analyzed to offer the proper frequency range of AE signals from the corona discharge for the purpose of AE sensor selection, From these results, a frequency spectra of AE signals emitted from the corona discharges in the void of an epoxy resin sample were about 190[kHz] to 220[kHz] by the FFT(fast fourier transform), A frequency spectra of AE signals emitted from a cast. resin transformer with non-load were appeared to be downward of about 140[kHz] by the FFT, and then a frequency spectra of AE signals emitted from the above of cast resin transformer with load were appeared to increase from about 190[kHz] to 220[kHz] by the FFT.

  • PDF

Analysis on Thermal Transfer Characteristics of 50 kVA Mold-Transformer (50[kVA] 몰드변압기 권선부의 열전달 특성 해석)

  • 이현진;정중일;허창수;조한구
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.47-54
    • /
    • 2002
  • This paper presented the charcteristic of the thermal transfer in a 50[kVA] cast-resin dry type transformer. The conductivity of the primary winding composed were a Plenty of epoxy-resin ard a little of Cu was determined by that rating. Otherwise the conductivity of the secondary winding composed of a plenty of Cu and a little of epoxy-resin was determined by comparing the data of analysis using FEM method with those of temperature tests of the prototype cast-resin transformer. Based on the reults of the physical characteristics and the simulation by commercial using FEM method we established the prototype Model for this test. According to that Model, an analysis on variation of the temperature was discussed as a function of ambient temperature and velocities in the 50[kVA] cast-resin dry type transformer.

Diagnosis of Cast Resin Transformer Using Analysis of Surface Temperature Distribution (표면온도분포 분석을 이용한 몰드 변압기 진단)

  • Lim, Yong-Bae;Chun, Jong-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.444-447
    • /
    • 2003
  • All objects with some temperature above absolute zero radiate in the infrared. The intensity of the infrared radiated from a object defends on the condition and temperature on the surface of the one. The present, these techniques are frequently adopted into diagnosis for electricity equipments. Simply, however, the applied techniques are passive thermal testing for the detection of loosened terminals and overcurrent. In this paper, a infrared thermal imager was applied to high voltage windings of cast resin transformers, and the accumulated value of the result temperatures was used for evaluating remained lifetime of them. At each aging level, dielectric loss tangent test was carried out. The results offered capabilities for deciding the condition of the transformers suffering difficulties to diagnose.

  • PDF

The Condition Assessment of Cast Resin Molded Transformer Windings Using Vertical Analysis of Thermal Distribution

  • Lim Young-Bae;Jung Jong-Wook;Jung Jin-Soo;Cho Seong won;Kim Joon-Bum
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.5
    • /
    • pp.191-195
    • /
    • 2005
  • This paper presents an assessment method in integrity of the windings in cast resin molded transformers by using vertical analysis of thermal distribution. The proposed method is to compare the temperature distribution in a sound specimen with that in the faulted specimen with a layer to layer short circuit. Temperature distribution was acquired by an infrared thermography system, and the Arrhenius equation was adopted to the accelerated test. The proposed method can be used to detect the failures in the transformers.

A Study on PD Detection Methods for Cast-resin Dry-type Transformers (몰드변압기의 부분방전 검출기술에 관한 연구)

  • Park, Chan-Yong;Park, Dae-Won;Choi, Jae-Sung;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.9
    • /
    • pp.786-791
    • /
    • 2009
  • Transformer failures are mostly due to partial discharges (PDs) caused by the deteriorated insulation. It is, therefore, important to monitor PD occurrence in insulation system and prevent their deterioration. The presented paper deals with a PD detection method by a capacitive probe, which easily apply to cast - resin dry - type transformers. The PD detection system consists of a capacitive probe and a low noise amplifier having the frequency bandwidth of 500 $Hz{\sim}30$ MHz. In the experimental set-up, sensitivity of the system is 7.16 mV/pC.