A Comparison of the Stray Loss in the Form of Tie-Plate of Cast Resin Transformer (몰드 변압기의 Tie-Plate 형태에 관한 손실 비교)

  • Kim, Yong-Bae;Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.691-692
    • /
    • 2015
  • 본 논문은 IEEE에서 제공하는 TEAM Problem 21번 주제를 참고하여 Tie-Plate의 최적설계안에서 기본적인 형태의 변화에 따른 손실 비교를 제시하였다. 기존의 Tie-Plate의 최적설계안은 본 저자의 논문에서 제시하여 Tie-Plate 중간부분에 $3{\times}3$의 형태로 설계되었다. Tie-Plate의 최적 설계안은 앞에서 보는 부분에서의 형태를 띄고 있으며 본 논문에서는 Tie-Plate의 기본 모델에서 적층되는 모델과 슬롯을 파는 모델 등으로 손실비교를 하였다.

  • PDF

A Study on the Confirmation of non-flammabikity of the Cast Resin Mold Transformer in Subway Substation (지하철 변전실용 진공주형형 몰드변압기의 난연성 확인에 관한 연구)

  • 정용기;장성규;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.99-107
    • /
    • 1998
  • This dissertationhas confirmed the non-flam mability of cast mold transformer that is increasingly used lately. As a research progress, the investigation has been performed on the installation status and each line of the subway system which have the most mold transformer accidents, and the impediment status of the transformer for rectifier and the high-voltage distribution transformer per each manufacturer. Then, a high voltage mold of the actual mold transformer has been installed in the horiwntal heating furnace and the heat has been applied by the standard heating temperature curve of KSF 2257(Fireproof testing meth od of the construction structures: 1993). Accordingly, the combustibility of the mold transformer based on the test results has been found that 78 minutes has been required for the complete burning per the KSF 2257 combustion test curve and that, after stopping the heat application of the horizontal furnace after ignition, the flame progress has not been made but shown as the self-extinguishing characteristics when the flame progress has been checked. Thus, the non-flammability and self-extinguishability of the mold transformer have been confirmed. The result of this dissertation has indicated that the accident involving mold transformer has been progressed and expanded by the dielectric breakdown or void due to the crack in the mold rather than a fire accident caused by a short-circuit or an overload.r an overload.

  • PDF

Measurement and Aalysis of Insulation Defects of Cast-resin Transformer on live wire state (활선상태에서 몰드변압기의 절연결함 측정기법 연구)

  • Choi, Myeong-Il;Lim, Young-Bae;Lee, Saing-Ik;Kim, Dong-Woo;Moon, Hyun-uk
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1569-1570
    • /
    • 2015
  • 몰드변압기는 유입변압기와 달리 구조적으로 복잡하고 밀폐된 구조로 되어 있어서 사용기간 동안 고신뢰성을 확보하기 위해서 예방진단기술이 필요하다. 그러나 공장이나 빌딩 현장에서 몰드변압기의 열화상태 관리하는 방법은 온도관리, 소음진동관리 등의 수준으로 활선상태에서 사고를 예측하기에는 많은 한계가 있다. 이러한 문제점을 해결하고자 본 논문에서는 몰드변압기의 부분방전 측정을 중심으로 활선상태에서 열화 진단기술이 중요하다. 특히, 몰드변압기의 절연열화 진단을 위해서 상호보완적인 측정방법이 필요하고, 몰드변압기의 절연상태의 유무를 판정할 수 있는 분석방법을 개발하고자 하였다.