• Title/Summary/Keyword: Case Base

Search Result 2,522, Processing Time 0.032 seconds

The Effect of the Chang in Forest Environment on physico-chemical Properhes of Soil Located in Seoul Royal Tomb (서울 왕릉지역의 산림환경변화가 토양 이.화학성에 미치는 영향)

  • Nam, Yi;Yee, Sun;Bae, Sang-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.3
    • /
    • pp.32-37
    • /
    • 2005
  • The soil properties of the royal tombs (managed by cultural properties administration) located in Seoul and suburban Gyonggi area were investigated to see the influence of the change in soil environment on the royal tomb s이I. To compare the soil chemical properties of four royal tombs soil of Changdeokgung, Jongmyo, Seooneung, and Dongguneung, pH, organic content, available phosphate, extractable calcium, extractable potassium, extractable magnesium, cation exchange capacity, degree of base saturation, and total nitrogen content were measured. The concentrations of Cd, Pb, and Cu measured as the degree of heavy metal contamination can be an indication of atmospheric pollution in the soil environment. To estimate the degree of soil compaction, soil hardness, pore space, porosity, bulk density, and soil atmosphere were analyzed. Through these studies, following conclusions were made: 1. The soil hardness and pore space which can be used as indexes of soil compaction, were worse in the soil of Seooneung than in those of Changdeokgung and Dongguneury. These phenomena seem to be the result of increase in visitors in Seooneung and Dongguneung better and soil management in Changdeokgung and Dongguneung. When three different regions of forest area, prohibited area, and soil compaction area in Seooneung soil were compared, the degree of compaction in the forest area was less than compaction area, indicating the need for the employment of soil resting period in the compaction area. 2. The pH measurements of all four royal tombs soil were higher in top soil than sub soil. The higher soil pH values in Jongmyo and Seooneung seem to result from the application of soil conditioner. In the case of Seooneung, the values for soil pH and organic content were higher in the forest area than those in compaction area. It is thought that active soil management was employed in the forest area through application of organic matters and soil conditioners. 3. The heavy metal contents from soil of Changdeokgung and Jongmyo were higher than that from soil of Dongguneung. Since Changdeokgung and Jongmyo are located inside Seoul, it is thought that the high level of heavy metal concentrations in these royal tomb soil is the result of accumulation of pollutants from the city.

Development of Convenience Evaluation Method of Urban Railway Station based on Universal Design - Focusing on Suseo Station - (유니버설디자인 기반 도시철도역사 편의성 평가방법 개발 - 수서역을 대상으로 -)

  • Lee, Sang Hwa;Kim, Hwang Bae;Kim, Hyun Joo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.159-165
    • /
    • 2018
  • In recent years, universal design concepts have been introduced that are designed to make everybody more comfortable and safe to use for products, buildings, environments, services, and so on. In the case of urban railroad history, it is important to maintain facilities that incorporate the universal design concept because it is an important facility that serves as a base of city life and there are various users. This research is the last annual task of 5 years as part of the project of "Development of Technique to Improve the Convenience of Urban Railway History User" by the National Institute of Transportation Technology Promotion Agency. The purpose of this study is to develop criteria and method of facilities convenience evaluation based on UD and to evaluate user convenience by selecting test bed station. For this purpose, the UD principle of the historic facilities of Weihai Urban Railway was established and detailed evaluation criteria were presented. As a result of evaluating the test bed history using the 5-point Likert scale of the joint research institute / railway operating agency / expert, 50.3% of convenience improvement was achieved. As a result of evaluating the applicability according to the UD principle, 48.7% Respectively. The evaluation criteria and methodology based on the UD suggested in this study is a quantitative method for evaluating UD application of urban railway facilities in the future.

Prospective for Successful IT in Agriculture (일본 농업분야 정보기술활용 성공사례와 전망)

  • Seishi Ninomiya;Byong-Lyol Lee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.2
    • /
    • pp.107-117
    • /
    • 2004
  • If doubtlessly contributes much to agriculture and rural development. The roles can be summarized as; 1. to activate rural areas and to provide more comfortable and safe rural life with equivalent services to those in urban areas, facilitating distance education, tole-medicine, remote public services, remote entertainment etc. 2. To initiate new agricultural and rural business such as e-commerce, real estate business for satellite officies, rural tourism and virtual corporation of small-scale farms. 3. To support policy-making and evaluation on optimal farm production, disaster management, effective agro-environmental resource management etc., providing tools such as GIS. 4. To improve farm management and farming technologies by efficient farm management, risk management, effective information or knowledge transfer etc., realizing competitive and sustainable farming with safe products. 5. To provide systems and tools to secure food traceability and reliability that has been an emerging issue concerning farm products since serious contamination such as BSE and chicken flu was detected. 6. To take an important and key role for industrialization of farming or lam business enterprise, combining the above roles.

Effects of four substances requiring preparation for accidents on the survival and reproduction of Paronychiurus kimi (Collembola: Onychiuridae) (사고대비물질 4종이 김어리톡토기의 사망 및 번식에 미치는 영향)

  • Wee, June;Lee, Yun-Sik;Son, Jino;Ko, Euna;Cho, Kijong
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.4
    • /
    • pp.749-758
    • /
    • 2019
  • The aim of this study is to provide a scientific basis for decision making regarding environmental damage in case of future chemical accidents by evaluating the ecotoxicity of 4 substances requiring preparation for accidents. For this purpose, acute and chronic toxicities of nitric acid, sulfuric acid, hydrogen peroxide, and ammonia solution, which can change the physical and chemical properties of soil to Paronychiurus kimi(Collembola) were investigated. The pH of artificial soil spiked with a series of test chemical concentrations was also measured. The pH of soil spiked with 10,000 mg kg-1 of soil nitric acid, sulfuric acid, hydrogen peroxide, and ammonia solution were 2.86, 2.72, 7.18 and 9.69, respectively. The 28-d LC50 of nitric acid, sulfuric acid, hydrogen peroxide and ammonia solution were 2,703, 5,414, 3,158 and 859 mg kg-1 soil dry wt., respectively and 28-d EC50 were 587, 2,148, 1,300 and 216 mg kg-1 soil dry wt., respectively. These results indicated that the mortality and juvenile production of P. kimi were influenced by not only the soil pH but also by the reduced organic content and products produced by the reaction of soil with the tested chemicals. Given the fact that most substances requiring preparation for accidents can change soil characteristics, assessment and restoration methods that take into account changes in soil properties are needed for accurate decision making after chemical accidents.

Analysis of the Ecological Environment for the Landscape Management of the Heritage Site: -A Case of Dongguneung, Kyunggi Province- (전통 사적공간의 경관관리를 위한 생태환경 분석 -경기도 구리시 동구릉을 중심으로-)

  • Lee, Sun;Jin, Sang-Chul
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.4
    • /
    • pp.366-377
    • /
    • 2002
  • This study investigated the ecological environment of Dongguneung, which royal tombs of the Joseon Dynasty aye in. The aim of this study is to do an effective preservation, management and restoration of the royal tomb and garden of the Joseon Dynasty distributed in Seoul and Kyunggi Province through using the data of Dongguneung. In general, Dongguneung contains the predominant Oak class such as Quercus serrata-Quercus mongolica community, while a flatland surrounding its control office, which is often flooded with the rainy season in summer, is mainly Alnus japonica community, Pinus densiflora community ranges around the royal tomb. The subcommunity of Quercus serrata -Quereus mongolica community is distributed into Robinia pseudo-acacia, Pinus rigida, Pinus koraiensis, Carpinus laxiflora and typical subcommunity and so on. In particular, Robinia pseudo -acacia, Pinus rigida and Pinus koraiensis subcommunity, and Alnus japonica community were forested. The soil class of Dongguneung was mainly a sandy loam and its pH was an average of 4.67 (from 4.36 to 5.68). The content of heavy metals including Cu, Pb and Zn etc. in the soil was about twice as much as the natural content in the forest soil. The content of organism and total nitrogen in the topsoil layer was the average of 4.87% and 0.21% respectively, slightly higher than those (organism; 4.55%, total nitrogen; 0.20%) of the forest soil generated from granite bedrock. Cation exchange capacity as the indicator of soil fertility was 15.0 cmol $kg^{-1}$, higher than that in the granite forest soil. However among base exchangeable cations, contents of $Ca^{2+}$ (2.07 cmol $kg^{-1}$), $Mg^{2+}$ (0.40 cmol $kg^{-1}$) and K+ (0.25 cmol $kg^{-1}$) were slightly lower than that. The above results could reflect the need of soil fertilization and liming for the improvement of nutritional status and buffer process.

Application Cases of Test Construction of Hydro-Seeding Measures on the Slopes Along the National Road Between Gamchon and Yaechon (감천예천구간 국도비탈면 종자뿜어붙이기 시험시공 적용사례)

  • Jeon, Gi-Seong;Woo, Kyung-Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.6
    • /
    • pp.139-151
    • /
    • 2007
  • To protect the surface of ground-cutting slopes and ground-raised slopes and to recover environment-friendly slopes at the national road expansion construction between Gamchon and Yaechon, test-construction work was done using several modes of hydro-seeding measures to select a suitable construction method through the field survey; the results were as follows : As a result of survey on physio-chemical characteristics of soil, the average soil inclination on ground-raised slopes was from 4.73 mm to 5.37 mm; the average soil acidity was from pH 6.47 to 6.73; the average soil humidity was within the scope of 0.57~1.70 %,; the average soil inclination on ground-cutting slopes was 9.17~10.43mm; the average soil acidity was pH 6.67~6.77 and the average soil humidity was within the scope of 0.53~1.27 %; considered overall, they showed generally satisfactory base materials for plant breeding. As a result of the number of sprouting individuals, the average sprouting number of individuals on test spots executed by Coir net with Seed spray construction methods and the average number of sprouting individuals on other test spots executed by furrow-digging with Seed spray and Straw mat-mulching measures were 1,172 number of per square meter and 970 number of per square meter respectively; thus they showed higher numerical value comparing with other test spots. Likewise, the average number of sprouting individuals on test spots of the ground-cutting slopes executed by Coir net with Seed spray method and the average number of sprouting individuals on other test spot executed by furrow-digger with Seed spray and Straw mat-mulching measures were found to be 1,107 number of per square meter and 1,105 number of per square meter respectively, whose numerical value showed rather higher other test spots. As a result of a survey on living plants' breeding index [dried weight], the weight in dried state on test spots executed by Coir net with Seed spray method and other test spots executed by furrow-digger with Seed spray and Straw mat-mulching measures on both ground-raised and ground-cutting slopes was found to be higher and showed similar characteristics statistically. As a result of survey on the surface-covering degree of ground-raised slopes, nine weeks after test construction, test spots executed by Coir net with Seed spray method and other test spots executed by furrow-digger with Seed spray and Straw mat-mulching measures showed commonly more than 70% of surface-covering degree, but other test spots showed only below 35% of surface covering degree; especially in case of test spots by Verdvol seed spray measures, they showed 10% of the lowest surface-covering. Surface-covering degree on the test spot of ground-cutting slopes nine weeks after test construction showed more than 75% both executed by Coir net with Seed spray construction method and executed by furrow-digger with Seed spray and Straw mat-mulching measures. As a result of survey on appearing plants on the test spots, there dominates Eragrostis curvula both on ground-raised slopes and on ground-cutting slopes with other seeding plant life's lower breeding and there appear intruders, such as Setaria viridis Beauv, Digitaria sanguinalis Scop, and Chenopodium album var.centrorubrum Makino. As for water-borne excavation and soil's washing-away on the slopes, there happened less washing-away and water-borne excavation with good breeding of plant life on test spots executed both by Coir net with Seed spray construction method and by furrow-digger with Seed spray and Straw mat-mulching measures, but there happened much more soil's washing-away along with water-home excavation at the test spot executed by Seed spray with measures. After the research results of test construction sites are examined overall, it's presumed that furrow-digger with Seed spray and Straw mat-mulching measures [interval between lines is 40cm, 5cm in depth] will be preferred to prevent erosion and water-home excavation of slopes located within the construction sites.

A Comparative Study on Thermal and Belt Press Dewatering for Waterworks Sludge Rduction (열 탈수와 벨트프레스 탈수장치의 현장적용에 따른 탈수성 비교연구)

  • Lee, Jung-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.10
    • /
    • pp.1016-1023
    • /
    • 2006
  • The water content of dewatered cake produced from belt press dewatering equipment was about 75 wt% which was some high to handle it, so the equipment contained a limit at the economical and environmental aspect. The thermal dewatering equipment built as an alternative to overcome several problems was set up at the sludge treatment field and estimated some feasibility as comparison with the dewatering performance of belt press. First, dewatering properties of waterworks sludge was analyzed by monthly. The sludge of a water shortage season contained a high organic content which led to be difficult to dewater the cake, the other side the sludge of rainwater season was ease to dewater because of low organic content. According to the results to analysis the water content of dewatered cake produced from two equipments on the base of the seasonal dewatering properties, the water content of dewatered cake produced from thermal dewatering for sludge of water shortage season was $41.6{\sim}48.3$ wt% and $71{\sim}84$ wt% from belt press. In the case of rainwater season, the water content of dewatered cake produced from thermal dewatering was $34{\sim}37.7$ wt% and $57{\sim}70$ wt% from belt press. It was understood that thereduction of water content of cake by thermal dewatering was larger than belt press. The economical aspect for two equipments was evaluated on considering the reduction of cake treatment amount as the decrease of water content of cake. When putting the cost index of thermal dewatering into 100, belt press was 121. This meant that thermal dewater was more economical than belt press by about 20% in the side of construction and operation. In conclusion, thermal dewatering equipment was estimated by producing the low water content dewatered cake as well as being operated with low coat.

Digital Hologram Compression Technique By Hybrid Video Coding (하이브리드 비디오 코팅에 의한 디지털 홀로그램 압축기술)

  • Seo, Young-Ho;Choi, Hyun-Jun;Kang, Hoon-Jong;Lee, Seung-Hyun;Kim, Dong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.5 s.305
    • /
    • pp.29-40
    • /
    • 2005
  • According as base of digital hologram has been magnified, discussion of compression technology is expected as a international standard which defines the compression technique of 3D image and video has been progressed in form of 3DAV which is a part of MPEG. As we can identify in case of 3DAV, the coding technique has high possibility to be formed into the hybrid type which is a merged, refined, or mixid with the various previous technique. Therefore, we wish to present the relationship between various image/video coding techniques and digital hologram In this paper, we propose an efficient coding method of digital hologram using standard compression tools for video and image. At first, we convert fringe patterns into video data using a principle of CGH(Computer Generated Hologram), and then encode it. In this research, we propose a compression algorithm is made up of various method such as pre-processing for transform, local segmentation with global information of object image, frequency transform for coding, scanning to make fringe to video stream, classification of coefficients, and hybrid video coding. Finally the proposed hybrid compression algorithm is all of these methods. The tool for still image coding is JPEG2000, and the toots for video coding include various international compression algorithm such as MPEG-2, MPEG-4, and H.264 and various lossless compression algorithm. The proposed algorithm illustrated that it have better properties for reconstruction than the previous researches on far greater compression rate above from four times to eight times as much. Therefore we expect that the proposed technique for digital hologram coding is to be a good preceding research.

A Study on Goryo Celadons of intaglio '○' pattern and '⊙'pattern (고려 음각 '○'문과 '⊙'문청자의 연구)

  • Han, Seong-Uk
    • KOMUNHWA
    • /
    • no.70
    • /
    • pp.133-161
    • /
    • 2007
  • It is judged that celadons with '○' pattern and '⊙' pattern have the indication of manufacturer by engraving mark at the internal center of the bottom. These celadons were produced at No.8.23.27 kiln sites located at Sadang-ri(사당리), Daegu-myon(대구면), Gangjin-gun(강진군), Jeollanamdo(전라남도), Korea and '⊙’ patterned celadon porcelain was found only at No. 23 and 27 kiln sites, so it is assumed that its production sites were limited. Kinds of celadons included bowl, dish, cup, bottle, case and vessel for emptied wine and there were a lot of dishes with a variety of patterns. These celadons were engraved by molded design technique using the same ceramic design as the pattern of celadons in the period of their prosperity and it was appropriate method to produce celadons of a good quality with production method to keep decorative design like pattern or size uniformly. It was also found that inlay method was not universalized in this period and similar celadons were produced with molded design in large quantities. These celadons had partially fire clay temper, but most of them were burnt by supporting the inner bottom of U-type base with quartzite after whole glazing. It was known through relics excavated at Seokreung(석릉) royal tomb of King Heejong(희종) at Ganghwa(강화) and Hyeeumwon(혜음원) temple site at Paju(파주) and military house at Wakamiyaoji(약궁대로) avenue Kamakura(겸창)-city, Japan(일본) that these celadons were manufactured at two quarters of the 13th century centering around 1230s. Therefore, these celadons will be significant materials to fill the gap of the celadons in the 13th century resulted from the record chronologically that green celadons were manufactured in the 12th century. And this period was invaded by Mongolia(몽고), but central control was achieved and green celadons were continuously produced. It was also considered that these celadons were excavated at Gabgot-ri(갑곶리) and Gwanchung-ri(관청리), Ganghwa(강화), Hyeeumwon temple, Paju which played the role of temporary palace, Bu1guksa(불국사) temple at Gyeongju(경주), Silsangsa(실상사) temple at Namwon(남원) and relics of Jangheung(장흥) adjacent to Daeguso(대구소) and these were produced for high class.

  • PDF

Clinical investigation of lipoid pneumonia in adults (성인에서 발생한 지방성 폐렴의 임상적 고찰)

  • Hyun, Jae Geun;Rhee, Chong H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.965-975
    • /
    • 1996
  • Background : Exogenous lipoid pneumonia is caused by inhalation or aspiration of animal, vegetable or mineral oil. Most cases are ascribed to aspiration of oil in laxatives or nose drops Petroleum, another pure hydrocarbon used as a base in various medications, is occasionally involved. Especially animal oil produces severe tissue inflammatory reaction, but most patients present with only abnormal chest X-ray and no specific clinical symptoms or signs. Method: Seven patients, 3 males and 4 females, with exogenous lipoid pneumonia, who was hospitalized or referred to pulmonary division at Samsung Medical Center from December 1994 10 July 1996, were included. They hadn a history of laking shark liver oil(so-called "squalene") for varying period of time. We reviewed clinical, radioloic and pathologic findings. Result: Patients look 7 to 30 capsules of "squalene" a day for at least one month to 5 years. Six cases had chronic disease such as diabetes, hypertension, or cerebrovascular accident. Respiratory symptoms of mild fever, cough and sputum were present in 3 cases and in 3 cases there was no clinical symptoms and signs but abnormal findings by chest X - ray. The major radiologic findings by simple chest X - ray and computed tomography consisted of consolidation, infiltration involving mainly right middle and both lower lobes, and ground-glass opacity. Five of six bronchoscopic examinations demonstrated both lipid droplets floating on the surface of bronchoalveolar lavage fluid and Lipid-laden macrophages in bronchoalveolar lavage fluid or lung tissue. Follow-up chest X -ray showed improvement in 4 cases but no marked interval change in 3 cases after removal of exposure to "squalene". Conclusion: Shark liver oil can induce lipoid pneumonia in adults. In case of high clinical suspicion, confirmation of "squalene" use by careful history taking is required and bronchoscopy is helpful in diagnosis.

  • PDF