• Title/Summary/Keyword: Case 2

Search Result 47,088, Processing Time 0.066 seconds

Comparision of Tidal Current Patterns at Keum River Estuary before and after Construction of Keum River Bank and Coastal Structures (금강하굿둑과 각종 해안구조물 설치 전, 후의 금강하구역 해수유동 양상 비교)

  • Jang, Chang-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.601-610
    • /
    • 2021
  • The tidal current patterns at Keum River Estuary before and after the construction of coastal structures were compared according to the CASES. The depth-integrated and tidal difference treatment applied FLOW2DH numerical model was used for the tidal current predictions. The test conditions consisted of before construction of coastal structures (CASE1), after construction of coastal structures (CASE2), and the addition of watergate operation(CASE1Q and CASE2Q), and present (CASE3). CASE1 showed a stable tidal current pattern, such as a natural estuary. In CASE2, the tidal current velocities and directions of the Keum River Estuary were changed due to the installed coastal structures. In particular, the tidal current velocities of the Gaeya open channel sections (P5~P9) in CASE2 were calculated to be 10~30% larger than that of CASE1. In the case of the Gunsan Inner Harbor (P4), which is closest to the Geum River Estuary, the ebb flow rate was approximately 250~300% faster than that of other CASEs due to the discharge of the watergate operation for 2.7 hours during the ebb of CASE1Q and CASE2Q. This will affect sediment transport, and it is predicted to lead to seabed changes. CASE3 is considered to be entering the stabilization stage according to the simulation of the tidal current velocities and directions of the Keum River Estuary and the surrounding coastal area.

A Study on Prioritizing and Evaluating R & D Alternatives for Fuel Cell Technology (연료전지 기술개발 추진전략간의 비교분석 방법론)

  • 최성수;정근모
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.45-53
    • /
    • 1993
  • This study was directed to an inquiry into a methodology for prioritizing and evaluating R & D alternatives for fuel cell technology, that can provide information for use in future decisions under the current uncertainty. A case study was performed for three cases of fuel cell development under the assumption that basic input data are same. The three cases are the case considering sequential R & D schedule only(Case 1), the case considering equivalent and excluding subprojects(Case 2), and the case allowing parallel efforts for each phase(Case 3). The following results were obtained; the probabilities of success for R & D phases in parallel projects are correlated, the probability of success for each project increases through Case 1, Case 2 and Case 3 successively and the expected dates of commercialization were notably shortened in Case 3.

  • PDF

Effects of Indoor Greening Method on Temperature, Relative Humidity and Particulate Matter Concentration (실내녹화 방법이 온·습도 및 미세먼지 농도에 미치는 영향)

  • Kwon, Kei-Jung;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.4
    • /
    • pp.1-10
    • /
    • 2017
  • This study investigated indoor temperature and humidity control and PM1 and PM10 mitigation effects of a single green wall (Case 1), two green walls (Case 2), and two green walls plus a waterfall (Case 3) in comparison with a control without either a green wall or waterfall. Experiments were conducted in the office of Chungbuk National University from August to September, 2015. Experiments were carried out sequentially in the order of control, Case 1, Case 2, and Case 3. Data collected from August 17 to August 20, 2015 (Experiment 1), and from August 31 to September 3, 2015 (Experiment 2), when outdoor temperature was relatively constant, were analyzed. Plant volume ratios by indoor landscaping of the control, Case 1, Case 2 and Case 3 were 0.0, 0.6, 1.2, and 1.4%, respectively. Compared to the control, average temperatures of Case 1, Case 2 and Case 3 were decreased by 0.3~0.7, 0.7~0.9 and $1.0^{\circ}C$, respectively, and relative humidity was increased by 1.8~8.7, 9.2~14.6 and 14.8~21.9%, respectively. Three hundred minutes after exposure to mosquito repellent incense particles, the ratio of the remaining PM1 of the control, Case 1, Case 2 and Case 3 were 25.0, 22.0%, 21.2%, 17.3%, respectively, in Experiment 1 and 42.3, 28.9, 23.1, and 30.9%, respectively, in Experiment 2. As indoor greening increased the effect of indoor temperature, PM1 and PM10 mitigation were greater, and temperature and humidity were lower. The greater the relative humidity was, the faster PM1 and PM10 mitigation tended to be.

Runoff Analysis of Mokgam Watershed considering the Climate and Landuse Change Scenarios (기후변화 및 토지이용변화 시나리오를 고려한 목감천 유역의 유출특성 분석)

  • Hong, Won-Pyo;Bae, Yong-Hoon;Kim, Mun-Ki;Park, Jong-Beum
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.924-928
    • /
    • 2012
  • 유역통합관리 계획 수립시 하천의 현재 뿐만 아니라 미래에 대한 환경변화도 고려되어야 한다. 즉, 하천 유역에 발생될 미래의 강우량과 토지이용변화, 인구 증가 등도 종합적으로 고려하여 유역통합관리 계획을 마련하여야 한다. 본 연구에서는 미래의 환경변화를 고려한 유역통합관리 계획의 기초 연구로서, 미래의 기후변화 및 토지이용변화 시나리오에 따른 목감천 유역의 유출특성을 분석하였다. 즉, 목감천 유역의 장기유출모의를 2020년~2039년의 20년 동안의 수행하였다. 이때 기후변화 시나리오는 GCM의 A1B, A2를 사용하였고 토지이용변화 시나리오는 ICM의 3단계, 즉, 불투수면적이 변하지 않는 경우(Case 1), 1 단계 증가하는 경우(Case 2), 2단계 증가하는 경우(Case 3)를 고려하였다. 모의 결과를 살펴보면, A1B의 기후변화 시나리오를 이용하였을 경우 최대 유출량은 $177m^3/s{\sim}190m^3/s$이 발생되며, 토지이용변화에 따른 유출 증가율은 Case 1에서 Case 2으로 변할 경우 1.7%, Case 2에서 Case 3으로 변할 경우 5.3% 증가하는 것으로 나타났다. 또한 A2의 기후변화 시나리오를 이용하였을 경우 최대 유출량은 $167m^3/s{\sim}173m^3/s$이 발생되며, 토지이용변화에 따른 유출 증가율은 Case 1에서 Case 2으로 변할 경우 1.2%, Case 2에서 Case 3으로 변할 경우 2.3% 증가하는 것으로 나타났다.

  • PDF

Process Simulation and Economic Feasibility of Upgraded Biooil Production Plant from Sawdust (톱밥으로부터 생산되는 개질 바이오오일 생산공장의 공정모사 및 경제성 분석)

  • Oh, Chang-Ho;Lim, Young-Il
    • Korean Chemical Engineering Research
    • /
    • v.56 no.4
    • /
    • pp.496-523
    • /
    • 2018
  • The objective of this study is to evaluate the economic feasibility of two fast pyrolysis and biooil upgrading (FPBU) plants including feed drying, fast pyrolysis by fluidized-bed, biooil recovery, hydro-processing for biooil upgrading, electricity generation, and wastewater treatment. The two FPBU plants are Case 1 of an FPBU plant with steam methane reforming (SMR) for $H_2$ generation (FPBU-HG, 20% yield), and Case 2 of an FPBU with external $H_2$ supply (FPBUEH, 25% yield). The process flow diagrams (PFDs) for the two plants were constructed, and the mass and energy balances were calculated, using a commercial process simulator (ASPEN Plus). A four-level economic potential approach (4-level EP) was used for techno-economic analysis (TEA) under the assumption of sawdust 100 t//d containing 40% water, 30% equity, capital expenditure equal to the equity, $H_2$ price of $1050/ton, and hydrocarbon yield from dried sawdust equal to 20 and 25 % for Case 1 and 2, respectively. TCI (total capital investment), TPC (total production cost), ASR (annual sales revenue), and MFSP (minimum fuel selling price) of Case 1 were $22.2 million, $3.98 million/yr, $4.64 million/yr, and $1.56/l, respectively. Those of Case 2 were $16.1 million, $5.20 million/yr, $5.55 million/yr, and $1.18/l, respectively. Both ROI (return on investment) and PBP (payback period) of Case 1(FPBU-HG) and Case 2(FPBU-EH) were the almost same. If the plant capacity increases into 1,500 t/d for Case 1 and Case 2, ROI would be improved into 15%/yr.

A Study on Prediction of Inundation Area considering Road Network in Urban Area (도시지역 도로 네트워크를 활용한 침수지역 예측에 관한 연구)

  • Son, Ah Long;Kim, Byunghyun;Han, Kun Yeon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.307-318
    • /
    • 2015
  • In this study, the efficiency of two-dimensional inundation analysis using road network was demonstrated in order to reduce the simulation time of numerical model in urban area. For this objective, three simulation conditions were set up: Case 1 considered only inundation within road zone, while Case 2 and 3 considered inundation within road and building zone together. Accordingly, Case 1 used grids generated based on road network, while Case 2 and 3 used uniform and non-uniform grids for whole study area, respectively. Three simulation conditions were applied to Samsung drainage where flood damage occurred due to storm event on Sep. 21, 2010. The efficiency of suggested method in this study was verified by comparison the accuracy and simulation time of Case 1 and those of Case 2 and 3. The results presented that the simulation time was fast in the order of Case 1, 2 and 3, and the fit of inundation area between each case was more than 85% within road zone. Additionally, inundation area of building zone estimated from inundation rating index gave a similar agreement under each case. As a result, it is helpful for study on real-time inundation forecast warning to use a proposed method based on road network and inundation rating index for building zone.

A Performance Study of Vent Mixer with Geometric Characteristics in Supersonic Flow (초음속 유동 내 벤트 혼합기의 형상적 특성에 따른 성능 연구)

  • Kim, Chae-Hyoung;Jeung, In-Seuck
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.1
    • /
    • pp.69-75
    • /
    • 2009
  • This paper studies the aerodynamic performance that the vent mixer-new conceptual supersonic mixer-showed with its geometric characteristics. The hole is 2 mm with 2 mm's distance from the wall in case 1 and with no distance in case 2. In case 3 die hole is 1 mm. Case 1 and case 2 showed the same total pressure recovery ratio, of which the case 3 was lower than that. While cases 1-3 had the same reattachment length, the shear layer was thicker in cases 1 and 2 than in case 3. Within the recirculation zone, cases 1 and 2 had lower pressure loss and higher velocity gradient difference than case 3-they enhance mixing between air and fuel. Separation bubble which is developed by the inflow into the recirculation zone has a significant effect on the total pressure recovery ratio in the combustor. Also separation bubble influences pressure distributions and recirculation flows in the recirculation zone. Therefore, inflow rate of air into the recirculation zone mainly affects the performance of vent mixer.

A Study on Correlation Between Accelerated Corrosion Test and Long-term Exposure Test According to the Temperature Condition (온도조건에 따른 철근부식 촉진시험과 장기폭로시험의 상관성에 관한 연구)

  • Park, Sang-Soon;So, Byung-Tak
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.2
    • /
    • pp.203-208
    • /
    • 2016
  • In this study, to clarify the differences rebar corrosion beginning, through the actual corrosion accelerated test in corrosion time and laboratory test chamber of the structure of the marine environment results in both environments, it is an object of correlation coefficient derived. The accelerated corrosion test was carried out by two case, I.e., one is $20^{\circ}C$ of low temperaure codition(case 1), and the other is $65^{\circ}C$ of high temperaute codition(case 2). Whether corroions occurs, it was measures using half-cell potential method. The results indicated that case 2 is to acclerate the corrosion of rebar about 1.7~1.8 times as compared with case 1, thenthe corrosion of rebar embadded in concrete occurred according to the order of OPC60, FA, BS, OPC35. Correlation coefficient between acclerated corrosion test and long-term exposure test, case 1 is 2.45 to 2.94, and case 2 is 4.37~4.99.

A Study on Verifying the Effect of Thermal Environment Control of Street Canyons based on Application of Green Wall System (거리협곡 벽면녹화 조성유형에 따른 미기상 변화 및 열환경 평가)

  • Kim, Jeong-Ho;Choi, Won-Jun;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.25 no.2
    • /
    • pp.311-322
    • /
    • 2016
  • This study reduced and built Street Canyons created by skyscrapers in order to verify effect of Street Canyons by green wall within the city centre and analysed influence factors on temperature reduction according to applicative types of green wall in the lab. Applicative types were divided into three types such as non- greening type(Case A), one-side greening type(Case B), both side greening type(Case C). The result of analysis of each types showed that average temperature of Case B and Case C is respectively $1.0^{\circ}C$ and $1.7^{\circ}C$ lower than Case A. The result of analysis of WBGT was that the highest temperature was given by Case A($40.2^{\circ}C$) and second one was from Case B($39.8^{\circ}C$) and third one was from ($39.1^{\circ}C$) and in UTCI Case A records the highest temperature of $34.7^{\circ}C$ and Case B provided the second highest temperature of $33.9^{\circ}C$ and Case B gave the lowest temperature of $32.7^{\circ}C$. In PMV the highest temperature of 2.65 was from Case B and second one of 2.61 was from Case A and third one of 2.54 was from Case C. Duncan analysis of each types based on solar radiation and thermal comfort generated that there was analytical significance between Case A and Case B and Case B in terms of each types of average temperature reduction. The significance of thermal comfort in WBGT, MRT, PMV showed non-significance but, In UTCI it was analysed that there was significance between Case C and Case A.

Analysis of Steady Flow by Main Pipe Arrangement in the Water Distributing Pipe Network (배수관망(配水管網)의 간선배치(幹線配置)에 따른 정류(定流)흐름 해석(解析))

  • Lee, Jeung Seok;Park, Ro Sam;Kim, Jee Hak;Choi, Yun Young;Ahn, Seung Seop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.73-82
    • /
    • 1999
  • In this study, the optimal analysis for pipe network is performed for the combined ideal pipe network system(CASE 1, CASE 2 and CASE 3) which is composed of 25 nodes, 41 elements, and 1 fixed nodal head with evaluating pressure variation distribution of main and branch in grid composed drainage pipe network. The linear analysis technique used as the analysis method in this study, the KYPIPE being used extensively as the linear technique to design and analysis of pipe network is applied. Firstly, in the analysis of pipe network, the CASE 2 and CASE 3 supply same thing(value) in the result of considering the total flow provided each pipeline, but in the general intension in the case of CASE 2, relative width of supply is more large than CASE 1 and CASE 3. Secondly, in the analysis technique of pipe network, CASE 3 is analysed largest as a result of comparing with same heads, and in the order of their size CASE 2 and CASE 1 were determined but the difference doesn't appear to be obvious. Thirdly, as the result of determining main factor, pressure in the design and analysis of net work. CASE 3 is from Node 3 to 25 than CASE 1 and CASE 2 and it is determined in the order of their size, CASE 2 and CASE 1. Finally, in this study, discharge flow distribution is evaluated in the same condition with 3-type CASE in the case of branch position for designing optimal composed drainage pipe network. As the result of that, branch pipe perform. Therefore, it is thought that the efficient and reasonable management of water supply and sewerage design will be possible if it give all our energies to study at the pipe system design in and out of country in the future.

  • PDF