• Title/Summary/Keyword: Carrier detection

Search Result 286, Processing Time 0.026 seconds

Detection of the Defect on the Metal Surface Using the Modulated Microwave (변조 고주파에 의한 금속표면 결함 검출)

  • Joo, G.T.;Jung, S.H.;Song, K.Y.;Kim, J.O.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.173-179
    • /
    • 1999
  • The defects on the metal surface. such as the ended circular pressed hole. the penetrated circular drilled hole, and the linear hollow lanes have been investigated by means of the microwave. In this experiment, frequency was set at 9.2GHz with 3kHz modulation, and the methods of reflection, transmission, fixed carrier frequency, and mod-demodulated technique have been used for investigating defects. The magnitudes of the microwave signals have been changed at the ended circular pressed hole and the penetrated circular drilled hole. The defect sizes that were estimated from the reflected microwave signals had the dimensions enlarged by twice the original size of the penetrated circular drilled hole and 2.5 times the original size of the ended circular pressed hole. The magnitudes of the reflected microwave signals from the linear hollow lane have increased with expansion of the width of the notch. In the linear hollow lane with the depth of 2.4mm, the reflected microwave signals versus the defect widths had a maximum value at the defect width of 50mm, and in the linear hollow lanes with the depths of 1.2mm and 0.45mm, the reflected microwave signals versus the defects widths had the maximum values each at the defect depths of 55mm.

  • PDF

Antibiotic Resistance Patterns of Staphylococcus aureus Isolated from the Specimen of University Students in Busan in 2004 (2004년 부산시내 일부 대학생의 검체에서 분리된 황색포도상구균의 항생제 내성 양상)

  • Kim, Tae-Un;Kim, Yun-Tae;Kwon, Heon-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.155-163
    • /
    • 2005
  • The purpose of this study is to investigate the carrier rate of S. aureus in the community, antibiotic susceptibility patterns of the organism, detection of MRSA and mecA gene in MRSA. Identification and antibiotic resistance patterns of S. aureus and MRSA were done by MicroScan Panels. MRSA strain was confirmed by disk diffusion method using oxacillin disk. The mecA gene in MRSA was detected by PCR. Eighty-four strains (27.4%) of S. aureus were isolated from the nasal specimens of 307 university students in Busan in 2004. Sixty-eight strains (81.9%) of 83 S. aureus were resistant to penicllin, 16 strains(19.3%) to erythromycin, 15 strains (18.1%) to gentamicin, 12 strains (14.5%) to tetracycline, 6 strains (7.2%) to chloramphenicol, 3 strains (3.6%) to ofloxacin, 2 strains (2.4%) to cefepime, clindamycin, imipenem, meropenem, norfloxacin, respectively. One strain (1.2%) was resistant to ciprofloxacin, cefazolin, cefotaxime, cefuroxime, and oxacillin. And all the strains (100%) of 84 S. aureus were susceptible to amoxicilin/K clavulanate, ticarcillin/K clavulanate, trimethoprim/sulfamethoxazole, rifampin, syncroid, teicoplanin, and vancomycin. One strain of 84 S. aureus isolates was methicillin-resistant Staphylococcus aureus (MRSA). The mecA gene was detected from the MRSA strain.

  • PDF

Blind Adaptive Receiver based on Constant Modulus for Downlink MC-CDMA Systems (하향링크 MC-CDMA 시스템을 위한 CM 기반의 블라인드 적응 수신기)

  • Seo, Bangwon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.5
    • /
    • pp.47-54
    • /
    • 2019
  • In this paper, we consider a constant modulus (CM) based blind adaptive receiver design for downlink multi-carrier code-division multiple access (MC-CDMA) systems employing simple space-time block coding (STBC). In the paper, filter weight vectors used for the detection of the transmitted symbols are partitioned into its subvectors and then, special relations among the optimal subvectors minimizing the CM metric are derived. Using the special relations, we present a modified CM metric and propose a new blind adaptive stochastic-gradient CM algorithm (SG-CMA) by minimizing the modified CM metric. The proposed blind adaptive SG-CMA has faster convergence rate than the conventional SG-CMA because the filter weight vectors of the proposed scheme are updated in the region of satisfying the derived special relations. Computer simulation results are given to verify the superiority of the proposed SG-CMA.

Investigation of chlamydophilosis from naturally infected cats

  • Wasissa, Madarina;Lestari, Fajar Budi;Nururrozi, Alfarisa;Tjahajati, Ida;Indarjulianto, Soedarmanto;Salasia, Siti Isrina Oktavia
    • Journal of Veterinary Science
    • /
    • v.22 no.6
    • /
    • pp.67.1-67.7
    • /
    • 2021
  • Background: Chlamydophila felis, formerly known as Chlamydia psittaci var. felis, is frequently associated with ocular, respiratory, and occasionally reproduction tract infections. Even though the infection is sometimes asymptomatic, it potentially results in a latent immunosuppressive infection. Objective: This study aimed to identify occurrences of feline chlamydophilosis, rarely reported in cats in Indonesia. Methods: The observation was conducted in three cats with clinical signs of Cp. felis infection, particularly relapsing conjunctivitis. The cats' histories were recorded based on owners' information. Conjunctival swabs were sampled for cytology examination and molecular assay detection. A phylogenetic tree was generated using MEGA-X software to reveal group clustering. A post-mortem examination was performed on the cat that died during an examination. Results: Cp. felis was detected in both cytological examination and polymerase chain reaction assay. The phylogenetic tree demonstrated that the Cp. felis isolated in this study clustered with several other isolates from the other countries. Cp. felis can be isolated from cats with different clinical manifestations and levels of severity. The chronic fatal infection demonstrated interstitial broncho-pneumonia under histopathological examination. Conclusions: Molecular assay of Cp. felis is always recommended to obtain a definitive diagnosis of feline chlamydophilosis since the disease can have various clinical manifestations. Even though it may be subclinical and is often not fatal, an infected cat may be a carrier that could spread the pathogen in the surrounding environment. Serious disease management is suggested to avoid high costs associated with regularly relapsing disease.

Steganography Software Analysis -Focusing on Performance Comparison (스테가노그래피 소프트웨어 분석 연구 - 성능 비교 중심으로)

  • Lee, Hyo-joo;Park, Yongsuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.10
    • /
    • pp.1359-1368
    • /
    • 2021
  • Steganography is a science of embedding secret data into innocent data and its goal is to conceal the existence of a carrier data. Many research on Steganography has been proposed by various hiding and detection techniques that are based on different algorithms. On the other hand, very few studies have been conducted to analyze the performance of each Steganography software. This paper describes five different Steganography software, each having its own algorithms, and analyzes the difference of each inherent feature. Image quality metrics of Peak Signal to Noise Ratio (PSNR) and Structural SIMilarity (SSIM) are used to define its performance of each Steganography software. We extracted PSNR and SSIM results of a quantitative amount of embedded output images for those five Steganography software. The results will show the optimal steganography software based on the evaluation metrics and ultimately contribute to forensics.

Development of Real-time and Simultaneous Quantification of Volatile Organic Compounds in Ambient with SIFT-MS (Selected Ion Flow Tube-Mass Spectrometry) (선택적다중이온질량분석기를 이용한 대기 중 휘발성유기화합물 실시간 동시분석법 개발 및 적용)

  • Son, Hyun Dong;An, Joon Geon;Ha, Sung Yong;Kim, Gi Beum;Yim, Un Hyuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.3
    • /
    • pp.393-405
    • /
    • 2018
  • Volatile organic compounds (VOCs) are representative air pollutants due to their detrimental effects on human health and their role in formation of secondary organic aerosols. Assessments and monitoring programs of VOCs using periodic grab sampling like Tedlar bags, canisters, and sorbent traps provide limited information, often with delay times of days or weeks. Selected ion flow tube mass spectrometry (SIFT-MS) is an emerging analytical technique for the real-time quantification of VOCs in air. It relies on chemical ionization of the VOCs molecules in air introduced into helium carrier gas using $H_3O^+$, $NO^+$, and $O_2{^+}$ precursor ions. Real-time monitoring method of 60 VOCs in the ambient air was developed using TO-15 standard gas mixture. Calibration curves, method detection limit, and quantitation reproducibility of the target compounds were tested. Dynamic dilution system was used to dilute standard gas from 0.174 ppbv to 100 ppbv, where calibration curves showed good linearity with $r^2$> 0.95 in all target analytes. Limit of detection (LOD) all compounds were sub ppbv, and some halogenated compounds showed pptv levels. Seven consecutive analyses of target compounds showed good repeatability with relative standard deviation of less than 10%. One day monitoring of VOCs in ambient air was conducted in Geoje. Average concentration of target VOCs in Geoje were relatively lower than other regions, among which formaldehyde showed the highest concentration ($15.4{\pm}5.78ppbv$). SIFT-MS provided good temporal resolution data (1 data per 3.2 minute), which can be used for identifying ephemeral short-term event. It is expected that SIFT-MS will be a versatile monitoring platform for VOCs in ambient air.

Design and Implementation of Receiver Algorithms for VDL Mode-2 Systems (VDL Mode-2 시스템을 위한 수신 알고리듬 설계 및 구현)

  • Lee, Hui-Soo;Kang, Dong-Hoon;Park, Hyo-Bae;Oh, Wang-Rock
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.10
    • /
    • pp.28-33
    • /
    • 2009
  • In this paper, we propose the receiver algorithms suitable for the VHF (Very High Frequency) digital link mode-2(VDL Mode-2) system. Unlike conventional digital communication systems using the root raised cosine filter as a transmit and receive filter, raised cosine filter is used as a transmit filter in the VDL Mode-2 system. Hence, it is crucial to design and implement the optimum lowpass receive filter by considering inter-symbol interference and noise performance. On the other hand, due to the short preamble pattern, it is crucial to develop an efficient packet detection algorithm for reliable communication link for the VDL Mode-2 system. Also, frequency offset due to the carrier frequency difference between transmitter and receiver and doppler frequency shift must be estimated and compensated for reliable communication. In this paper, the optimum receive filter, packet detection and frequency offset compensation algorithms are proposed and the performance of the VDL system employing the proposed algorithms are evaluated.

Amperometric Determination of Histamine using Immobilized Enzyme Reactors with Different Carriers (담체 고정화 효소 반응기를 이용한 Histamine의 전기화학적 측정)

  • Ji, Jung-Youn;Jeon, Yeon-Hee;Kim, Mee-Ra
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.22 no.1
    • /
    • pp.88-94
    • /
    • 2012
  • Histamine is a kind of primary biogenic amine arising from the decarboxylation of the amino acid L-histidine. The toxicology of histamine and its occurrence and formation in foods are especially emphasized in fermented foods. In this study, the biosensor for detection of histamine with functionalized multi-walled carbon nanotubes (MWCNT) was developed. We also searched for an appropriate insoluble substrate to immobilize the enzyme. The developed biosensor showed a detection limit of $0.1{\mu}M$ hydrogen peroxide. The enzyme reactor was prepared with diamine oxidase immobilized on insoluble carriers including CNBr-activated sepharose 4B, calcium alginate, and controlled pore size glass beads. The coupling efficiency of CNBr-activated sepharose 4B, calcium alginate, and controlled pore size glass beads were 48.5%, 40.3%, and 51.0%, respectively. In addition, the response currents on histamine with each immobilized enzyme reactor prepared with CNBr-activated sepharose 4B, calcium alginate, and controlled pore size glass beads were 120 nA, 110 nA, and 140 nA at $100{\mu}M$ of histamine concentration, respectively. Therefore, it is suggested that controlled pore size glass beads are the best carriers for immobilizing diamine oxidase to detect histamine in this biosensor.

ELISA Development for the residue of the organophosphorus insecticide acephate (ELISA에 의한 유기인계 살충제 Acephate 잔류물 분석법 개발)

  • Lee, Jae-Koo;Ahn, Ki-Chang;Stoutamire, Donald W.;Gee, Shirley J.;Hammock, Bruce D.
    • The Korean Journal of Pesticide Science
    • /
    • v.5 no.2
    • /
    • pp.1-12
    • /
    • 2001
  • A competitive indirect enzyme-linked immunosorbent assay (ci ELISA) for the organophosphorus insecticide acephate, O,S-dimethyl acetylphosphoramidothioate, was developed using a polyclonal antibody. Three different haptens mimicking the analyze and containing hexanoic acid moiety as a linker were synthesized, and then conjugated with the carrier proteins bovine serum albumin and keyhole limpet hemocyanin by the N-hydroxysuccinimide active ester method. Polyclonal antibodies raised against hapten-KLH conjugates in rabbits and the hapten-BSA conjugates as coating antigens were screened and selected for the assay in the homologous and/or heterologous ELISA system. The effects of various assay conditions, including blocking reagents, detergent content, organic solvents, pH, and preincubation of tile mixture of the polyclonal antibody and the analyze on the sensitivity were evaluated. The $IC_{50}$ value of acephate of 110 ng/mL was obtained in an optimized heterologous system using hapten-3-BSA as a coating antigen and a polyclonal antibody 8377, showing the detection range of 10-1000 ng/mL and the lowest detection limit of 4 ng/mL. The cross-reactivities of the structurally related insecticides, including methamidophos were less than 0.02%. These results indicate that the ELISA could be a convenient and alternative tool for monitoring acephate residues in agricultural products and environmental samples.

  • PDF

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.