• 제목/요약/키워드: Carried over

검색결과 4,880건 처리시간 0.032초

탄성 및 점성 부하시 공기압 실린더 시스템의 디지털 위치 제어 (Digital Positioning Control of Pneumatic Cylinder System with Elastic and Viscous Load)

  • 박명관;문영진;편창관
    • 한국정밀공학회지
    • /
    • 제15권1호
    • /
    • pp.137-144
    • /
    • 1998
  • For a model system consisted of four pneumatic cylinders with strokes of 10, 20, 40 and 80 mm, investigation was carried out experimentally and numerically about the reliability of system with elastic and viscous load. The elastic load affects the performance of each cylinder in cylinder series, and changes the time lag and the velocity of the piston which makes the positioning control rather difficult. Taking the effects of the elastic load into consideration, positioning can be carried out comparatively smoothly by only adjusting the driving timing. The effect of a viscous load reduces the vibration of each moving body in the cylinder series and also reduces the over-travelled distance which happens when several cylinders move at the same time. For reasons, a positioning with a viscous load can be relatively smoothly carried out even without the timing control.

  • PDF

새로운 Over-the-Cell 배선시스템 (A New Over-the-Cell Routing System)

  • 이승호;정정화
    • 대한전자공학회논문지
    • /
    • 제27권11호
    • /
    • pp.135-143
    • /
    • 1990
  • 본 논문에서는 채널의 배선 밀도 뿐만 아니라 셀 영역 내의 배선 밀도도 효과적으로 감소시키는 새로운 over-the-cell배선 시스템을 제안한다. over-the-cell 배선 시스템은, 일반적으로 셀 영역에서의 배선 과정, 채널에서 배선될 터미널의 선택 과정, 그리고 채널 배선 과정으로 구성된다. 본 논문에서는 셀 영역에서 배선할 신호선을 효율적으로 선택하기 위하여 intersection graph 상에 채널의 배선 밀도와 다른 신호선과 교차 관계를 고려한 웨이트를 부여한다. 선택된 신호선이 feedthrough나 셀 내부 로직을 형성하는 메탈층과 교차할 경우, maze 알고리듬을 사용하여 셀 영역에 배선한다. 또한 minimum weight spanning tree를 이용하여 채널에 배선할 터미널들을 효율적으로 선택하여 채널 밀도를 감소시킨다. 채널 배선은 HAN-LACADMG의 채널 배선기를 사용한다. Benchma가 데이타를 사용한 실험과 게이트 어레이 레이아웃 시스템에 적용함으로써 본 over-the-cell 배선 시스템의 효용성을 보인다.

  • PDF

분산전원 연계 계통에서의 과전류계전기 오동작에 관한 연구 (A Study on the Over Current Relay Misoperation in Power System with Distributed Generations)

  • 박종일;이계병;박창현
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1705-1710
    • /
    • 2018
  • This paper deals with an analysis of the causes of over current relay(OCR) misoperation in power system with distributed generations(DG). In general, Y-D and Y-Y-D transformer connections are used for grid interconnection of DG. According to the interconnection guideline, the neutral point on Y side should be grounded. However, these transformer connections can lead to OCR misoperation as well as over current ground relay(OCGR) misoperation. Several researches have addressed the OCGR misoperation due to the interaction between transformer connections and zero-sequence voltage of distribution system. Recently, a misoperation of OCR at the point of DG interconnection to the utility system has been also reported. With increasing the interconnections of DG, such OCR as well as OCGR misoperations are expected to increase. In this paper, PSCAD/EMTDC modeling including DG interconnection transformer was performed and various case studies was carried out for identifying the cause of OCR misoperation.

박리전단층이 축대칭 하향단흐름에 미치는 영향 (Effect Of The Separating Shear Layer on the Flow Over an Axisymmetric Backward-Facing Step)

  • 부정숙;김경천;양종필
    • 대한기계학회논문집
    • /
    • 제19권4호
    • /
    • pp.1102-1115
    • /
    • 1995
  • An experimental study on the flow over the axisymmetric backward-facing step was carried out. The purpose of the present study is to investigate the effect of the boundary layer thickness at the separation point on the reattachment length and to understand the structure of the recirculating flows. Local mean and fluctuating velocity components were measured in the separating and reattaching axisymmetric turbulent boundary layer over the wall of convex cylinder placed in a water tunnel by using 2-color 4-beam fiber optics laser Doppler velocimetry. The study demonstrated that the reattachment length increases with increasing boundary layer thickness. It was also observed that the reverse flow velocity and turbulent kinetic energy decrease with an increase in the momentum thickness at the separation point. The measured velocity field suggests that the boundary layer thickness at the separation can affect definitely on the formation of corner eddy.

후드겸용 전자렌지 시로코홴의 소음특성에 관한 연구 (A study on the aeroacoustic characteristics of the sirocco fan of over the range)

  • 전완호;송성배;손상범;류호선
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.123-128
    • /
    • 2002
  • Over the range(OTR) has been applied for cooking and ventilation functions especially in northern Amarica. Because flow rate and operating rpm of the double sided sirocco fan for ventilation are much higher and than the microwave oven system, the major noise source is the sirocco fm. Recently, the quiet fan development is one of very important issues for amenity. In this study, the noise source identification using multi-microphone array system was carefully carried out and numerical simulations for understanding the aerodynamic and aeroacoustic of the fan were peformed. The sound level of tonal noise is predicted with a good accuracy but that of the broadband shows some discrepancy. In order to reduce the broadband noise, the inlet region of sirocco fan have to be modified that the secondary flow should be suppressed. Based on these results, new low noise fan and OTR is now developing.

  • PDF

마그네트 천장크레인의 최적설계와 직교배열을 이용한 민감도 분석 (The Optimum Design of Magnet Over Head Crane and the Sensitivity Analysis for Orthogonal Array)

  • 노영희;홍도관;최석창;안찬우;한근조
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.786-790
    • /
    • 2002
  • In this study, structural optimum design was applied to the girder of magnet over head crane. The optimization was carried out using ANSYS Code for the deadweight of girder, especially focused on the thickness of its upper, lower, side and reinforced plates. The weight could be reduced up to around 15% with constraints of its deformation, stress, natural frequency and buckling strength. The structural safety was also verified by the buckling analysis of its panel structure. It might be thought to be very useful to design the conventional structures for the weight save through the structural optimization. The objective function and restricted function were estimated by the orthogonal array, and the sensitivity analysis of design variable fur that was operated.

  • PDF

지표면 변화와 인공열이 바람장에 미치는 영향에 관한 수치 시뮬레이션 (Numerical Simulation of Effect of Urban Land-use Type and Anthropogenic Heat on Wind Field)

  • 홍정혜;김유근
    • 한국대기환경학회지
    • /
    • 제16권5호
    • /
    • pp.511-520
    • /
    • 2000
  • The urban atmosphere is characterized by th difference in surface and atmospheric environment between urban and more natural area. To investigate th climatic effect of land use type and anthropogenic heat of urban on wind field, numerical simulations were carried out under typical summer synoptic condition. The wind model PNU_MCM(Pusan National University Mesoscale Circulation Model) is based on the three-dimensional Boussinesq equations, taking into account the hydrostatic assumption . Since lane-use differs over every subdivision on Pusan the surface energy budget model includes sub0grid parameterization scheme which can calculate the total heat flux over a grid surface composed of different surfaces. The simulated surface wind agrees well with the observed value, and average over 6 days which represent typical summer lan-sea breeze days, August 1998, i.e. negligible gradient winds and almost clear skies. Urbanization makes sea-breeze enhance at day and reduce land-breeze at night. The results show that contribution of land-use type is much larger than that of anthropogenic heat in Pusan.

  • PDF

언덕이 있는 하상유동 계측을 통한 PTV기법의 수력학적 적용연구 (Assessment of PIV to Measure the Flow Field Over a Fixed Dune Bed)

  • 현범수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.217-220
    • /
    • 2002
  • The assessment of PIV to measure the mean velocity and turbulence was carried out over a train of fixed two-dimensional dunes. The agreement between the PIV and LDV is good enough even in regions of flow reversals and high shear. Though limited in the wall normal direction field-of-view, PIV provides instantaneous flow fields, which reveal the complex nature of flow over dunes, as well as more sophisticated analyses such as two-point space correlation and quadrant analysis with a reasonable accuracy.

  • PDF

Catalytic Upgrading of Geodae-Uksae 1 over Mesoporous MCM-48 Catalysts

  • Jeon, Ki-Joon;Jin, Sung Ho;Park, Sung Hoon;Jeon, Jong-Ki;Jung, Sang-Chul;Ryu, Changkook;Park, Young-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권7호
    • /
    • pp.1951-1955
    • /
    • 2014
  • Catalytic pyrolysis of Geodae-Uksae 1, a kind of miscanthus found in Korea, was carried out over mesoporous MCM-48 catalysts. For rapid product analysis and catalyst evaluation, pyrolysis-gas chromatography/mass spectrometry was used. X-ray diffraction, nitrogen sorption, pyridine adsorbed Fourier transform infrared, and NH3 temperature programmed desorption were utilized to analyze the properties of the catalysts. Compared to non-catalytic reaction, catalytic upgrading over mesoporous Al-MCM-48 catalysts produced a higher-quality bio-oil with a high stability and low oxygen content. Al-MCM-48 exhibited higher deoxygenation ability than Si-MCM-48 due to its higher acidity.

고효율 신광원 시스템의 특성에 관한 연구 (A Study of High Efficiency Electrodeless lamp Properties)

  • 김현숙;이세현;신상욱;임종민;허성국;황명근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1717-1720
    • /
    • 2002
  • Electrodeless discharge lamps have been objects of interest and research for several decades, mainly because of their potential for extremely long life, high lamp efficacies and smaller than standard fluorescent lamps size. A series of measurements and observations concerning variables has yielded optical and electrical characteristics for electrodeless discharge lamp like incandescent lamp and circular lamp feature. Last experiment were carried out to determine the lamp temperature at several surface points during operation. Light output levels in excess over 60,000 cd/$m^2$ have been measured in electrodeless discharge lamp for a general of conditions. At lamp surface temperatures have been measured over $80^{\circ}C$, and starting current have been measured over ${\sim}A$.

  • PDF