• Title/Summary/Keyword: Carotid

Search Result 998, Processing Time 0.028 seconds

A Study on Effects of the Transient Compression by Tightly Tied Necktie on Blood Flow in the Internal Jugular Veins Using 2D-PC MRA (2D-PC MRA를 이용한 넥타이의 순간적인 압박(壓迫)이 내경정맥의 혈류에 미치는 영향에 대한 연구(硏究))

  • Kim, Keung-Sik;Chung, Tae-Sub;Park, In-Kook;Lee, Bum-Soo;Kim, Hyun-Soo;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.267-276
    • /
    • 2008
  • The 25 healthy male volunteers aged from 20 to 50years old have been employed in this study. 2D-PC MRA was performed to measure the velocity of the blood flow in the internal carotid artery and internal jugular veins using 3.0T MRI Whole body (signa VH/i GE). ECTRICKS-CEMRA was performed to evaluate the pattern of blood circulation from internal carotid artery to internal jugular vein. Using 2D-PC MRA, the cross-section of the 4th and 5th cervical discs was scanned with 24cm FOV. Then the speed of blood flow was measured for internal carotid artery and internal jugular vein when the subject wears a necktie tightly and no tie. The average of maximum velocity of internal carotid arteries without a necktie was 72.13cm/sec in the right side and 74.96cm/sec in the left side(average 73.54cm/sec in both sides) while the average of maximum velocity of internal jugular veins without a necktie was -34.45cm/sec in the right side and -24.99cm/sec in the left side (-29.72cm/sec in both sides). However, when wearing a necktie tightly, the average of maximum velocity of internal carotid arteries was 61.35cm/sec in the right side and 65.19cm/sec in the left side(average 63.27cm/sec in both sides) while the average of maximum velocity of internal jugular veins was -22.14cm/sec in the right side and -17.93cm/sec in the left side(-20.03cm/sec in both sides). With the necktie tightly knotted, the average blood flow speed of both internal carotid arteries slightly decreased to 86% (63.27/73.54cm/sec) compared to no tie case in which both internal jugularveins significantly went down to 67% (-20.03/-29.72 cm/sec). Thus it is suggested that wearing a necktie affects the circulation of internal jugular veins(33% decrease in blood flow speed) more significantly than that of internal carotid artery(14% decrease in blood flow speed). Without a necktie, ECTRICKS-CEMRA showed natural blood circulation patterns of internal carotid arteries and internal jugular veins without any disturbances or compressions. However, when wearing a necktie tightly, ECTRICKS-CEMRA showed severe compression onto both internal jugular veins in all 25 volunteers. In conclusion, the result of the study showed that the tightly worn necktie instantly presses more internal jugular veins than internal carotid arteries, thereby significantly reducing the blood flow speed and leading to the temporary occlusion. Thus, the defecation or washing the face under the tightly tied necktie situations can cause the unexpected and temporary compression or occlusion of the internal jugular veins, subsequently leading to the occurrences of the stroke due to the secondary intracranial venous hypertension.

  • PDF

Inter-Rater Reliability of Carotid Intima-Media Thickness Measurements in a Multicenter Cohort Study (다기관 코호트 연구에서 경동맥 내막-중막 두께 측정의 측정자간 신뢰도 평가)

  • Lee, Jung Hyun;Choi, Dong Phil;Shim, Jee-Seon;Kim, Dae Jung;Park, Sung-Ha;Kim, Hyeon Chang
    • Journal of health informatics and statistics
    • /
    • v.41 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • Objectives: Carotid intima-media thickness (CIMT) and the presence of carotid artery plaque are widely used as preclinical markers of atherosclerosis. Due to operator dependency in measuring CIMT, it is important to evaluate the reliability of measuring CIMT and plaque between centers in a multicenter study. The purpose of this study is to evaluate the inter-rater reliability of CIMT and plaque presence among three clinical centers of the Cardiovascular and Metabolic Disease Etiology Research Center (CMERC). Methods: Twenty people without known cardiovascular disease (age 37-64) were enrolled during 2014-2015, and their left and right carotid arteries were examined repeatedly with ultrasonography for CIMT measurements at three clinical centers according to a predetermined protocol. Maximum and mean values of CIMT at distal common carotid artery were recorded. Plaque presence at a carotid artery was checked by an operator. The reliability of CIMT and carotid plaque presence was assessed using an intraclass correlation coefficient (ICC) and kappa statistics, respectively. Results: Calculated ICC was 0.647 (95% CI: 0.487-0.779) for maximum CIMT, and 0.758 (95% CI: 0.632- 0.854) for mean CIMT. In Bland Altman plot, most observed values were distributed within mean difference ${\pm}1.96$ SD ranges. Kappa statistics of plaque presence between two centers were 0.304 (center 1 and 2), 0.507 (center 1 and 3), and 0.606 (center 2 and 3), respectively, while Fleiss kappa for overall agreement was 0.445. Conclusions: The inter-rater reliability of CIMT measurements among three clinical centers turned out to be high, and the agreement of measuring carotid plaque presence was fair.

Associations between Carotid Intima-media Thickness, Plaque and Cardiovascular Risk Factors (경동맥 내중막 두께 및 죽종과 심 혈관 질환 위험요인과의 관련성)

  • Lee, Young-Hoon;Cui, Lian-Hua;Shin, Min-Ho;Kweon, Sun-Seog;Park, Kyeong-Soo;Jeong, Seul-Ki;Chung, Eun-Kyung;Choi, Jin-Su
    • Journal of Preventive Medicine and Public Health
    • /
    • v.39 no.6
    • /
    • pp.477-484
    • /
    • 2006
  • Objectives : This study was conducted to examine the association between the carotid artery intima-media thickness (IMT), plaque and cardiovascular risk factors according to gender and age. Methods : The data used for this study were obtained from 1,507 subjects (691 men, 816 women), aged 20-74 years, who participated in 'Prevalence study of thyroid diseases' in two counties of Jeollanam-do Province during July and August of 2004. The body mass index (BMI) and waist hip ratio (WHR) were calculated by anthropometry The blood pressure, pulse rate, pulse pressure, total cholesterol, triglyceride, HDL cholesterol and fasting blood sugar level were also measured. Ultrasonography was used to measure the carotid artery IMT and plaque. IMT measurements were performed at 6 sites, including both common carotid arteries, and the bulb and internal carotid arteries. The definition of the 'mean IMT' was mean value obtained from these 6 sites. Results : The ${\pm}$ standard deviation IMT values were $0.65{\pm}0.14\;and\;0.60{\pm}0.13mm$ in men and women (p<0.001), respectively. The data were analyzed according to gender and the 50 year age groups. In a multiple linear regression analysis, age and hypertension were positively associated with the mean IMT in both men and women, aged<50 years. Age, total cholesterol and smoking (current) were positively associated with the mean IMT in men $(\geq50\;years)$. Age was positively associated with the mean IMT in women $(\geq50\;years)$, but the HDL cholesterol level was negatively associated. The prevalence of plaques was 44.2%(196/443) in men and 19.4%(89/459) in women, for those greater than 50 years of age. In a multiple logistic regression analysis, age (OR=1.090, 95%CI=1.053-1.129), HDL cholesterol (OR=0.964, 95%CI=0.944-0.984), total cholesterol (OR=1.009, 95%CI=1.002-1.017)and BMI (OH=0.896, 95%CI=0.818-0.983) were independently associated with plaques in men; whereas, age (OR=1.057, 95%CI=1.012-1.103), HDL cholesterol (OR=0.959, 95%CI=0.932-0.986), pulse pressure (OR=1.029, 95%CI=1.007-1.050) and triglycerides (OR=0.531, 95%CI=0.300-0.941) were independently associated with plaques in women. Conclusions: There were significant gender and aging differences in the association between the IMT, plaque and cardiovascular risk factors. Therefore, for the prevention of atherosclerosis, selective approaches should be considered with regard to gender and age factors.

Direct Repair of a Dorsal Wall Aneurysm on Supraclinoid Internal Carotid Artery

  • Kim, Young-Gyun;Kim, Young-Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.2
    • /
    • pp.160-162
    • /
    • 2005
  • Aneurysms arising at locations other than arterial division are rare and the incidence of intraoperative bleeding is far higher in such aneurysms than in usual aneurysms. The authors report a case of intraoperative rupture and laceration on internal carotid artery(ICA) wall during dissecting a dorsal wall aneurysm on supraclinoid ICA and successful repair of the laceration on the parent ICA with microsuture and a Sundt clip-graft.

Hyaluronic Acid Filler Injection Guided by Doppler Ultrasound

  • Won Lee
    • Archives of Plastic Surgery
    • /
    • v.50 no.4
    • /
    • pp.348-353
    • /
    • 2023
  • Doppler ultrasound can be used to detect almost all arteries of the face before injecting the hyaluronic acid (HA) filler. The relatively more dangerous sites of filler injection are the glabellar wrinkle, forehead, temple, nose, and nasolabial fold area, and it is recommended to map the vasculature of these areas by Doppler ultrasound before performing filler injection. The Doppler ultrasound detection method is included as a video. Internal carotid arterial branches, the supratrochlear, supraorbital, and dorsal nasal arteries, and external carotid arterial branches, the superficial temporal and facial arteries, are very important arteries when injecting HA filler; thus, Doppler ultrasound detection is recommended.

A Study on High-Resolution Technique in MRI Scan for Cerebral Aneurysm Disease -Comparison between High-Resolution Technique and Standard Technique- (뇌 동맥류 질환 자기공명검사에서 고분해능(High-Resolution) 기법의 관한 연구 - 고분해능기법과 표준기법 비교 -)

  • Choi, Sung-Hyun;Goo, Eun-Hoe;Hwang, Sun-Kwang;Lee, Gang-Won;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.7-12
    • /
    • 2012
  • The purpose of this study was to examine usefulness of 3T equipment-based time-of-flight magnetic resonance angiography (3T-TOF MRA) by comparing standard technique (ST) with high resolution technique (HRT) in evaluation of cerebral blood vessel. The 3T-TOF MRA was performed for 31 patients who were suspected of having cerebrovascular disease from March to July 2010. For evaluation of cerebral blood vessel, classification was conducted randomly: group I that included vertebral artery and basilar artery, group II that ranged from 2.5cm before basin part of common carotid artery to basin part of internal and external carotid arteries and to genu part of internal carotid artery, group III that ranged from vertebral part of internal carotid artery to the first basin art of anterior and middle cerebral through education recognizes the importance of dose reduction and examine if their efforts and further reduce patient dose could achieve optimization of the medical exposure is considered.

  • PDF

Delayed Diagnosis of Cerebral Infarction after Complete Occlusion of ICA due to Blunt Head Trauma: A Case of Report (두부둔상 후 내경동맥손상으로 인한 뇌경색의 지연진단: 증례보고)

  • Yun, Jung-Ho;Ko, Jung Ho;Cho, Chun-Sung
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.190-194
    • /
    • 2015
  • Blunt cerebrovascular injury is defined as a vertebral or carotid arterial structural wall injury resulting from nonpenetrating trauma. Complete traumatic internal carotid artery occlusion is very rare condition accounting for 0.08~0.4 0f all trauma patients and believed to be associated with the greatest risk of ischemic stroke reported in 50~90% in a few small series. A 55-year-male was admitted with drowsy mentality and severe headache after a fall down accident. Brain computed tomography showed a subdural hematoma at the both frontal area with a fracture of the occipital skull bone. Two days after admission, he suddenly complained with a right side hemiparesis of motor grade 2. Brain magnetic resonance diffusion demonstrated multiple high flow signal changes from the left frontal and parietal lesion. Computed tomographic angiogram (CTA) revealed absence of the left ICA flow. Trans femoral cerebral angiography (TFCA) showed complete occlusion of the left internal carotid artery (ICA) at ophthalmic segment in the left ICA angiogram and flows on the left whole hemispheric lesions through the anterior communicating artery in the right ICA angiogram. We decided to conduct close observations as a treatment for the patient because of acute subdural hematoma and sufficient contralateral cerebral flow by perfusion SPECT scan. Two weeks after the accident, he was treated with heparin anticoagulation within INR 2~4 ranges. He recovered as the motor grade 4 without another neurologic deficit after 3 months.

  • PDF

Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting

  • Lee, Jong Hyeok;Sohn, Hee Eon;Chung, Seung Young;Park, Moon Sun;Kim, Seong Min;Lee, Do Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.316-320
    • /
    • 2015
  • Objective : The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. Methods : From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid artery stenosis ${\geq}70%$ were treated with CAS with embolic protection device in single center. All patients underwent post-CAS diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic lesions. We compared clinical outcomes and postprocedural embolization rates. Results : CAS was performed in all 61 patients. Distal filter protection success rate was 96.6% (28/29), whose mean age was 70.9 years, and mean stenosis was 81%. Their preprocedural infarction rate was 39% (11/28). Subsequent DW-MRI revealed 96 new ischemic lesions in 71% (20/28) patients. In contrast, the proximal balloon occlusion device success rate was 93.8% (30/32), whose mean age was 68.8 years and mean stenosis was 86%. Preprocedure infarction rate was 47% (14/30). DW-MRI revealed 45 new ischemic lesions in 57% (17/30) patients. Compared with distal filter protection device, proximal balloon occlusion device resulted in fewer ischemic lesions per patient (p=0.028). In each group, type of stent during CAS had no significant effect on number of periprocedural embolisms. Only 2 neurologic events occurred in the successfully treated patients (one from each group). Conclusion : Transfemoral CAS with proximal balloon occlusion device achieves good results. Compared with distal filter protection, proximal balloon occlusion might be more effective in reducing cerebral embolism during CAS.

Protected versus Unprotected Carotid Artery Stenting : Meta-Analysis of the Current Literature

  • Cho, Young Dae;Kim, Sung-Eun;Lim, Jeong Wook;Choi, Hyuk Jai;Cho, Yong Jun;Jeon, Jin Pyeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.458-466
    • /
    • 2018
  • Objective : To compare peri-operative any symptomatic stroke after carotid angioplasty and stenting (CAS), based on the application or absence of a cerebral protection device. Methods : A systematic literature review using PubMed, Embase, and the Cochrane Central was done across an online data base from January 1995 to October 2016. Procedures which were performed due to carotid dissection or aneurysm, procedures using covered stents or conducted in an emergency, were excluded. The primary endpoint was perioperative any symptomatic stroke within 30 days after the procedure. A fixed effect model was used in cases of heterogeneity less than 50%. Results : In the 25 articles included in this study, the number of stroke events was 326 (2.0%) in protected CAS and 142 (3.4%) in unprotected CAS. The use of cerebral protection device significantly decreased stroke after CAS (odds ratio [OR] 0.633, 95% confidence interval [CI] 0.479-0.837, p=0.001). In the publication bias analysis, Egger's regression test disclosed that the intercept was -0.317 (95% CI -1.015-0.382, p=0.358). Regarding symptomatic patients (four studies, 539 CAS procedures), the number of stroke was six (1.7%) in protected CAS and 11 (5.7%) in unprotected CAS. The protective effect against stroke events by cerebral protection device did not have a statistical significance (OR 0.455, 95% CI 0.151-1.366, p=0.160). Conclusion : The use of protection device significantly decreased stroke after CAS. However, its efficacy was not demonstrated in symptomatic patients. Routine use of protection device during CAS should be critically assessed before mandatory use.