• Title/Summary/Keyword: Cardiopulmonary bypass machine

Search Result 18, Processing Time 0.018 seconds

Acute Cardiac Tamponade, Report of 6 Cases (각종 원인에 의한 급성 Cardiac Tamponade: 6례 보고)

  • 조장환;이명진;홍승록
    • Journal of Chest Surgery
    • /
    • v.5 no.2
    • /
    • pp.97-106
    • /
    • 1972
  • We will report 6 cases of cardiac tamponade treated surgically at Severance Hospital during the past 9 years from 1964 to 1972 and reviewed literatures on cardiac tamponade. The age of patients was from 13 years to 45 years old. The male was 4 cases and the female 2 cases. The sites of injury were right atrium; 1 case, right ventricle; 2 cases, right ventricle and coronary artery; 1 case, left atrium; 1 case, and left ventricle; 1 case. 2 cases of cardiac tamponade developed following chest injury, 2 cases following pericardiocentesis,1 case due to continuous bleeding from sutured cardiotomy wound of left atrium following open mitral commissurotomy using cardiopulmonary bypass machine, and 1 case due to traumatic penetration of polyethylene catheter through right ventricle to pericardial sac, introduced via right jugular vein in order to monitor the central venous pressure. Central venous pressure was checked preoperatlvely in 5 cases. In all cases, central venous pressure was rised [the range of central venous pressure was 240 to 330 mmHg]. Immediately after operation,central venous pressure lowered to normal [the range was 80-100 mmHg]. Recently serial gas analysis of arterial blood were checked pre- and post-operatively for the evaluation of hemodynamic change of cardiac tamponade, but our data was not enough for evaluation. It should be studied further.

  • PDF

Experimental Studies of the Blood Gas Transport during Normothermic Hemodilution Perfusion (상온하 혈액희석 체외순환에 있어서 혈액 GAS 동태에 관한 실험적 연구)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.85-91
    • /
    • 1980
  • Extracorporeal circulation by hemodilution technique has been currently used with its clinical safety and good peripheral tissue perfusion in open heart surgery. There is no doubt that $O_{2}$ carrying capacity of the blood is disturbed by decreased hemoglobin level resulting from hemodilution of the circulating blood. From the view point of the blood gas exchange, these experimental studies were undertaken to determined the sate limit of hemodilution in the condition of cardiopulmonary bypass with a constant perfusion flow rate. Twelve adult mongrel dogs weighing 10 to 13 Kg. were anesthetized with pentobarbital and then respiration was controlled with Harvard volume respirator using room air. The cardiopulmonary by pass was performed by use of Sarns heart lung machine (console 5000, 5 head and 2 roller pumps) and Travenol pediatric bubble oxygenator. The perfusion rate during bypass was maintained at a constant rate of 80 ml/min/Kg of body weight. The ratio of oxygen gas flow to blood flow was kept in 3 to 1 constantly. International hemodilution was attained by serial blood withdrawals and immediate infusion of equal volumes of diluants composed of Ringer's lactate, 5% dextrose in water and 25% mannitol solution, proportionally 60%, 30%, and 10%. Arterial and venous blood samples were obtained between 15 and 20 minutes following each hemodilution. Hematocrits and hemoglobin values, $PO_{2}$, $PCO_{2}$ and pH were measured. Oxygen and carbon dioxide contents oxygen consumption and carbon dioxide elimination were calculated groups according to different hematocrit values and the correlations were evaluated. Result were as follows. 1. the arterial $O_{2}$ tension and $O_{2}$ saturation were maintained at the physiological level irrespective of the hematocrit value. 2. The venous $O_{2}$ tension and $O_{2}$ saturation showed a tendency to decline with the decrease in hematocrit value and positive correlation between them (r = +0.49, r = +0.76), The mean values of venous $O_{2}$ tension and $O_{2}$ saturation, however, were not decreased when the hematocrit levels were lower than 20%. 3. The arterial $O_{2}$ content declined lineally in proportion to the fall of hematocrit level with a positive correlation between them (r = +0.95). 4. The venous $O_{2}$ contents were decreased gradually as the hematocrit value decreased with positive correlation between them ( r =+0.89). The trend of diminution of venous $O_{2}$ content, however, was became low according to progressive decrease of hematocrit level. 5. Systemic oxygen consumption was in higher range than $O_{2}$ requirement of basal metabolism when the hematocrit value was above 20%, but abruptly decreased when the hematocrit value became to below 20%. 6. The arterial $CO_{2}$ tension and $CO_{2}$ content showed trend of increasing with progressive decrease of hematocrit value but exhibited a rather broad range and there was no relationship between those value and the hematocrit value. 7. The venous $CO_{2}$ tension and $CO_{2}$ content have also no correlation with change of Ht. value but related directly to those value of arterial blood with positive correlation between them (r = +0.78, r = +0.95_. 8. A-V difference of $CO_{2}$ content and $CO_{2}$ elimination wasnot significantly influenced by Ht. value. From the results, we obtained that feasible limit in inteneional hemodilution is above the hematocrit value of 20% under the given experimental condition.

  • PDF

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.

A Clinical Evaluatuin on Open Heart Surgery of Congenital and Acquired Heart Disease (선천성 및 후천성 심질환의 개심술)

  • 김근호
    • Journal of Chest Surgery
    • /
    • v.12 no.1
    • /
    • pp.33-42
    • /
    • 1979
  • The present study reports 41 cases of congenital and acquired heart diseases, who received open heart surgery under extracorporeal circulation [ECC] by Sarns Heart-Lung-Machine [HLM] at the Department of Thoracic and Cardiovascular Surgery, Hanyang University Hospital during the` period between July 1975 and February 1979. The priming of pump oxygenator was carried out by the hemodilution method using Hartman`s solution, whole blood, and fresh human plasma. The rate of hemodilution was in the average of 50.8 ml/kg. ECC was performed at the average perfusion flow rate of 85.0 ml/kg/min [2.43 L./ kg/2] and at moderate hypothermia. In the total cardiopulmonary bypass, arterial pressure ranged between 55 mmHg and 90 mmHg, but generally maintaining over 70 mmHg. Patient age ranged between 2 and 54 year old, in congenital heart diseases, between 2 and 28, in acquired heart diseases, between 17 and 54 Sex ratio of male to female was 20:21. The cases include a case of pulmonary valvular stenosis, 4 cases of atrial septal defect, 9 cases of ventricular septal defect, 9 cases of tetralogy of Fallot, 5 cases of pentalogy of Fallot, 3 cases of atypical multiple anomalies 7 cases of mitral stenosis or insufficiency, a case of myxoma in left atrium, and a case of ruptured aneurysm of Valsalva`s sinus. The surgical managements were 16 valvulotomy for pulmonary valvular stenosis, 2 Teflon patch graft closure and 5 simple suture closure of atrial septal defect, 16 Teflon patch graft closure and 5 simple suture closure of ventricular septal defect, 12 pericardial patch graft for infundibular stenosis of right ventricle, one anastomosis between left superior vena cava and right atrium, 2 open mitral commissurotomy, 5 mitral valve replacement using Starr-Edward`s ball valve, porcine xenograft by Hancock, by Carpentier-Edward, or Angell-Shiley, one removal of left atrial myxoma, and a repair of ruptured aneurysm of Valsalva`s sinus. Four [9.7%] out 41 cases expired postoperatively and the rest of 37 cases survived with satisfactory results. The causes of death were one coronary embolism in tetralogy of Fallot, 2 postoperative lower cardiac output in atypical multiple anomalies, and one right heart failure in large: ventricular septal defect with pulmonary hypertension.

  • PDF

Clinical experience of open heart surgery -70 cases- (개심술 70예의 임상경험)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.644-662
    • /
    • 1986
  • Seventy cases of open heart surgery were performed in the department of Thoracic and Cardiovascular Surgery, Pusan Paik Hospital, Inje College, from Oct. 1985 to Oct. 1986. And the results were summarized as follows. 1. Among the 70 cases, there were 48 cases of congenital heart anomalies and 22 cases of acquired rheumatic valvular heart diseases. Age range of the congenital patients was 7 months to 31 years with the mean age of 10 years, and the acquired patients was 18 to 62 years with the mean age of 40 years. 2. The heart-lung machine used for cardiopulmonary bypass was Sarns 7000, 5-head roller pump, and the number and type of oxygenators were 5 of membrane type and 65 of bubble type. For all cases GIK [glucose-insulin-potassium] solution was used as cardioplegic solution for myocardial protection during operation. 3. Among the 48 congenital anomalies, there were 12 cases of ASD group, 29 of VSD group, 3 of ECD, 3 of TOF and one of PDA + MR, and to all of which the appropriate radical operations were applied. 4. Among the 22 acquired valvular diseases, there were 11 cases of mitral valve diseases [MS; 4, MSr; 3, MRs; 4], 3 cases of aortic valve diseases [AR:1, ARs;1, ASr;1], 4 cases of double valve diseases [MRs+TR; 3, MRs+ARs; 1] and 4 cases of triple valve diseases [MSr+ASr+TR; 3, MSr+Ar+TR; 1]. To all the diseased mitral and aortic valves, artificial valve replacement was applied except one [As], in which valve plication was applied. And to all the diseased tricuspid valve, DeVega annuloplasty was applied. 5. The number of replaced artificial valves were 29 in 25 patients [congenital; 3, acquire; 22]. In MVR, 6 of mechanical valves [St. Jude Medical valve; 6] and 15 of tissue valves [Carpentier-Edward valve; 11, lonescu-Shiley valve; 4] were used. In AVR, 6 of mechanical valves [St. Jude Medical valve; 6] and 2 of tissue valves [Carpentier-Edward valve; 2] were used. 6. Postoperative complications were occurred in 12 cases. Among them 11 cases were recovered with intensive cares, but one patient [VSD + Fistula of Valsalva sinus] was expired with low cardiac out put syndrome.

  • PDF

Open Heart Surgery 110 Cases in One Year(1987) (연간 (1987년) 개심술 110례에 대한 검토)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.21 no.2
    • /
    • pp.351-365
    • /
    • 1988
  • During one year[1987], 110 cases of open heart surgeries were performed in the department of Thoracic and Cardiovascular Surgery, Pusan Paik Hospital, Inje Medical College. And the results were summarized as follows. 1. Among the 110 cases, there were 77 cases of congenital heart diseases and 33 cases of acquired heart diseases. Age range of the congenital patients was 8 months to 30 years with the mean age of 8 years, and acquired patients was 16 to 56 years with the mean age was 32 years. 2. The heart lung machine used for cardiopulmonary bypass was Sarns 7000, 5-head roller pump, and the number and type of oxygenators were 50 of membrane type and 60 of bubble type. For all cases GIK[glucose-insulin-potassium] solution was used as cardioplegic solution for myocardial protection during operation. 3. Among the 77 congenital anomalies, there were 67 cases of acyanotic patients[ASD: 12, VSD: 50, PS: 1, AP window: 1, Gerbode defect: 1, ECD: 2] and 10 cases of cyanotic patients[TOF: 10], and to all of which the appropriate radical operations were applied. 4. Among the 33 acquired diseases, there were one case of left atrial myxoma, one of annuloaortic ectasia, 20 of mitral valve diseases[MS: 2, MSr: 8, MR: 2, MRs: 8], 9 of double valve diseases[MRs+AR: 1, MRs+ARs: 2, MRs+TR: 1, MSr+TR: 3, MSr+ASr: 1, MSr+ARs: 1], 2 of triple valve diseases[MSr+AR+TR: 1, MSr+ASr+TR: 1]. The left atrial myxoma was removed well with right atriotomy and atrial septal approach. And to the annuloaortic ectasia, Bentall operation was applied with good result. Mitral valve replacement[MVR] was applied to 20 cases of mitral valve diseases, double valve replacement[MVR+AVR] was applied to 6 cases of double valve diseases, MVR & tricuspid annuloplasty[TVA] was applied to 3 cases of mitral 5. The number of replaced valve were 39 in 31 cases. In MVR, 5 of mechanical valves[St. Jude Medical Valve] and 26 of tissue valves[Carpentier-Edward valve] were used. In AVR, 3 of mechanical valves and 5 of tissue valves were used. 6. Postoperative complications were occurred in 23 cases, and among them 21 cases were recovered with intensive cares, but 2 cases were expired[mortality: 1.8%].

  • PDF

Experimental Studies on Extracorporeal Circulation by Sarns Heart-Lung Machine with Total Prime of Hartman's Solution (Sarns 심폐기의 혈희석 체외순환에 관한 실험적 연구)

  • 김근호
    • Journal of Chest Surgery
    • /
    • v.8 no.2
    • /
    • pp.135-142
    • /
    • 1975
  • Total body perfusion using Sarns Heart-Lung-Machine, five head pump motor system with Travenol disposable bubble oxygenator was attempted in the dogs by the hemodilution method with total prime of buffered Hartman`s solution under moderate hypothermia. The first of all, the functions of Sarns Heart-Lung-Machine and effects of the hemodilution perfusion by buffered Hartman`s solution was studied. At the same time the changes of pressure of artery and vein, gas contents of the blood, and influence on the blood pictures were observed before, during, and after perfusion in 1-2 days. Hemodilution rates were the ranges of 85.0ml/kg to 97.3ml/kg and perfusion flow rates were maintained with the average 80. 5ml/kg/min [the ranges of 73.3ml/kg/min to 92.8ml/kg/min]. Hypothermia was employed between $35^{\circ}C$ and $31^{\circ} of the esophageal temperature. The total body perfusion was continued for 50-60 minutes. In the total cardiopulmonary bypass, atriotomy, ventriculotomy, and atrioventriculotomy were performed respectively. Arterial pressure was ranged approximately between 50 mmHg and 140 mmHg, but generally, it was maintained over 75 mmHg. Venous pressure was measured between 3.8 cm$H_2O$ and 16.0 cm$H_2O$. Optimum oxygenation could be achieved when oxygen flow into the oxygenator was maintained approximately at 5. 5L/min. In this way, the $pO_2$, $pCO_2$, and oxygen saturation were measured before, during, and afterperfusion in 1-2 days. The $pCO_2$ ranged approximately between 26.0 mmHg and 38.5 mmHg, but generally, it was maintained in the average 30.9-32.5mmHg. The $pO_2$ was ranged between 73.0mmHg and 332.2 mmHg, but it was maintained in the average 103.0-219.0 mmHg. Oxygen saturation was measured over 95. 0% during and after extracorporeal circulation respectively. Erythrocyte count, hemoglobin, hematocrit, and leucocyte count were decreased to 49.2%, 49.0%, 49.4%, and 21. 1% of the preoperative value during extracorporeal circulation respectively and these reductions were not recovered until 1-2 days after perfusion. These. resulted from relatively high degree of hemodilution rate and operative bleeding during these experimental studies. The platelets count was also decreased about to 71% during perfusion, on the contrary, it was increased progressively after perfusion and in 1-21 days after perfusion, the value was returned to preoperative contro1 level. Three dogs were all recovered after extracorporeal circulation.

  • PDF

Open Heart Surgery 600 Cases for 5 Years (5년간 개심술 600예에 관한 검토)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.404-420
    • /
    • 1991
  • Surgical treatment of congenital and acquired heart disease preceded the development of accurate techniques for diagnosis, heart lung machine and cardiopulmonary bypass, intraoperative myocardial protection, operative techniques and cardiac anesthesia. For 5 years from Sep. 1985 to Sep. 1990, six hundred cases of open heart surgeries [OHS] were performed in the department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, College of Medicine, Inje University. The results were summarized as follows. 1. The annual number of OHS[cases per year] was above 100 since 1987, and the increasing rate of cases was 23.5% per year since 1986. 2. Among the total 600 cases, there were 470 cases of congenital heart diseases and 130 cases of acquired. Age range of the congenital patients was 8 months to 44 years with the mean age of 10 years, and acquired patients was 16 to 56 years with the mean age of 36 years. 3. Among the 470 congenital anomalies, there were 429 cases of acyanotic and 41 cyanotic patients. Totally, VSD was 286 cases[60.6%], ASD 103 cases[21.9%], TOF 35 cases [7.4%], PS 20 cases [4.1%], ECD 12 cases [2.0%], Ebstein`s anomaly 3 cases [0.6%], Valsalva sinus rupture 3 cases [0.6%] and others. The appropriate one stage radical operations were applied to the all congenital cases with the result of 2.6% immediate postoperative hospital mortality rate. 4. Among the 130 acquired cases, there were 122 cases of valvular heart diseases, 6 of heart tumors [5 myxoma, one malignant histiocytoma], one of LA thrombus and one of annuloaortic ectasia. Cardiac tumors and LA thrombus were removed through the atrial septal approach. Bentall procedure was adopted to the annuloaortic ectasia case. AVR, MVR and TVA [DeVega procedure] were applied to 120 valve diseases, and there were also one of OMC and one of MVA[Jerome-Kay procedure]. 5. Among the 120 valve replacement cases, there were 87 of single valve replacement cases [AVR: 8, MVR: 79], 11 of double valve replacement [AVR+MVR: 11], 12 of MVR+TVR and 10 of MVR+AVR+TVA. The total number of implanted prosthetic valves were 141. In MVR, 45 of St. Jude Medical valves, 63 of Carpentier-Edward valves and 4 of Ionescu-Shiley valves were used. In AVR, 18 of St. Jude Medical valves and 11 of Carpentier-Edward valves were used. in MVR, 29mm and 31mm sized valves were used mostly and In AVR, 23mm sized valves were used mostly. 6. Postoperatively many kinds of complications were occurred. Among them, wound problems [30 cases], low output syndrome [29 cases], arrhythmia [20 cases], pleural effusion and pneumothorax [13 cases] were occurred frequently. The postoperative immediate hospital mortality was 3.0% in total [congenital 2.6%, acquired 4.6%].

  • PDF