• Title/Summary/Keyword: Cardiac valve annuloplasty

Search Result 46, Processing Time 0.027 seconds

Chordae Tendineae Approximation Technique for Severe Tricuspid Regurgitation with Severe Leaflet Tethering Using a Totally Endoscopic Beating-Heart Strategy: A Case Report

  • Dong Hee Jang;Jae Suk Yoo
    • Journal of Chest Surgery
    • /
    • v.56 no.1
    • /
    • pp.56-58
    • /
    • 2023
  • Untreated severe tricuspid regurgitation (TR) is associated with poor outcomes. Functional TR occurs secondary to dilatation of the annulus and tethering of the leaflets. Ring annuloplasty alone can correct most cases, but is insufficient in cases of severe annular dilatation due to severe leaflet tethering. In such cases, a tricuspid edge-to-edge technique may be an option. However, stitching of the leaflet tips alone is likely to result in tearing of the leaflets. Approximation of the durable chordae tendineae is considered helpful for this problem. Herein, we present the case of a 39-year-old man who had undergone open-heart surgery for acute type A aortic dissection 13 months earlier. A right mini-thoracotomy approach with a beating-heart strategy was used, which did not require unnecessary pericardial adhesiolysis and dissection. This technique had the advantage of reducing the operation time and the risk of bleeding. To summarize, we present a case of tricuspid valve repair in a high-risk patient with severe leaflet tethering that was successfully managed using these methods.

Mitral Valve Replacement following Prior Left Pneumonectomy (좌측 전폐절제술을 받았던 환자에서 시행한 승모 판막 치환술)

  • Lee, Geun-Dong;Chung, Cheol-Hyun;Jung, Jae-Seung;Lee, Jae-Hoon;Jung, Sung-Ho
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.759-763
    • /
    • 2008
  • Cardiac surgery in patients with a prior pneumonectomy has a high prevalence of postoperative complications and mortality. We have successfully performed a mitral valve replacement and tricuspid annuloplasty in a 71-year-old man who had a left pneumonectomy 33 years previously due to pulmonary tuberculosis. We report this case with a literature review on the issue of the prevention perioperative pulmonary impairment, the technique of mitral valve exposure during surgery and postoperative rhythm disturbance.

Clinical experience of open heart surgery -70 cases- (개심술 70예의 임상경험)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.644-662
    • /
    • 1986
  • Seventy cases of open heart surgery were performed in the department of Thoracic and Cardiovascular Surgery, Pusan Paik Hospital, Inje College, from Oct. 1985 to Oct. 1986. And the results were summarized as follows. 1. Among the 70 cases, there were 48 cases of congenital heart anomalies and 22 cases of acquired rheumatic valvular heart diseases. Age range of the congenital patients was 7 months to 31 years with the mean age of 10 years, and the acquired patients was 18 to 62 years with the mean age of 40 years. 2. The heart-lung machine used for cardiopulmonary bypass was Sarns 7000, 5-head roller pump, and the number and type of oxygenators were 5 of membrane type and 65 of bubble type. For all cases GIK [glucose-insulin-potassium] solution was used as cardioplegic solution for myocardial protection during operation. 3. Among the 48 congenital anomalies, there were 12 cases of ASD group, 29 of VSD group, 3 of ECD, 3 of TOF and one of PDA + MR, and to all of which the appropriate radical operations were applied. 4. Among the 22 acquired valvular diseases, there were 11 cases of mitral valve diseases [MS; 4, MSr; 3, MRs; 4], 3 cases of aortic valve diseases [AR:1, ARs;1, ASr;1], 4 cases of double valve diseases [MRs+TR; 3, MRs+ARs; 1] and 4 cases of triple valve diseases [MSr+ASr+TR; 3, MSr+Ar+TR; 1]. To all the diseased mitral and aortic valves, artificial valve replacement was applied except one [As], in which valve plication was applied. And to all the diseased tricuspid valve, DeVega annuloplasty was applied. 5. The number of replaced artificial valves were 29 in 25 patients [congenital; 3, acquire; 22]. In MVR, 6 of mechanical valves [St. Jude Medical valve; 6] and 15 of tissue valves [Carpentier-Edward valve; 11, lonescu-Shiley valve; 4] were used. In AVR, 6 of mechanical valves [St. Jude Medical valve; 6] and 2 of tissue valves [Carpentier-Edward valve; 2] were used. 6. Postoperative complications were occurred in 12 cases. Among them 11 cases were recovered with intensive cares, but one patient [VSD + Fistula of Valsalva sinus] was expired with low cardiac out put syndrome.

  • PDF

Clinical Experience of Medtronic-Hall Valve (Medtronic-Hall 기계판막의 임상경험)

  • 김종원;정성운
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1031-1036
    • /
    • 1998
  • Background: Medtronic-Hall mechanical valve is a world widely using prosthesis. But, in Korea, the clinical result from Medtronic-Hall valve replacement is not frequenthy available. Materials and methods: From March 1986 to May 1990, 50 patients underwent valve replacement surgery with Medtronic-Hall valve at Pusan National University Hospital. Seventeen were male and thirty three were female and ra nging in age from 16 to 70 years of age(mean=35 years). Results: The causes of valvular lesion were rheumatic in 43 patients, bicuspid aortic valve in 3 patients, degenerative lesion in three patients and bacterial endocarditis in one patient. The operative procedures were mitral valve replacement(MVR) in 38, aortic valve replacement(AVR) in 5 and double valve replacement(DVR) in 7. The most commonly used valve size was 21mm in AVR, 29mm in MVR. Concomitant surgical procedures were performed in 15 patients; left atrial thrombectomy in 9, left atrial auricle obliteration in 6 and tricuspid annuloplasty in 5(Kay: 2, DeVega: 3). New York Heart Association functional class was mostly Class Ⅲ or Ⅳ(91.5%) preoperatively and ClassⅠor Ⅱ(87.2%) after operation. The findings of postoperative echocardiogram of LAD, LVESD, LVEDD were reduced compared with preoperative period and ejection fraction was increased compared with preoperative period. Postoperative complications were massive bleeding in three, low cardiac output syndrome in two, thromboembolism in one and fulminant hepatitis in one patient. There were three hospital deaths and their causes were low cardiac output syndrome in two and rupture of left ventricle in one patient. The 5 year survival rate was 93.65±0.71% and 10 year actuarial survival rate was 88.27±6.42%. Conclusions: Medtronic-Hall mechanical valve has low valve related complication rate. It's durability and hemodynamic performance is comparable to other mechanical valves.

  • PDF

Mitral Valve Repair for Mitral Regurgitation (승모판막폐쇄부전에 대한 승모판막재건술)

  • 최세영;유영선;박기성;최대융;박창권;이광숙
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.221-225
    • /
    • 1998
  • From February 1996 to May 1997, 18 patients underwent mitral valve repair for mitral regurgitation. There were 9 male and 9 female patients aged from 19 to 68 years(mean, 53). Thirteen patients were in New York Heart Association(NYHA) class III and IV. The cause of mitral regurgitation was degenerative in 12 patients, rheumatic in 5 patients and infective in 1 patient. Fifteen patients were in Carpentier's functional classification II, 2 patients in Carpentier's class III and 1 patient in Carpentier's class I. Surgical procedures included prosthetic ring annuloplasty(16 cases), rectangular resection of posterior leaflet(15 cases), chordal shortening(5 cases), triangular resection of anterior leaflet(2 cases), commissurotomy(2 cases), partial transposition of posterior leaflet(1 case). These procedures were combined in most patients. There was no operative death. These patients have been followed from 1 to 15 months, mean of 6.7 months. There was one late death resulted from low cardiac output following mitral valve replacement. The function of the repaired valve in other 17 patients has remained satisfactory during the observed interval. We consider that mitral valve repair is highly satisfactory in patients with mitral regurgitation.

  • PDF

Clinical Study of Isolated and Combined Aortic Valve Replacement (대동맥판막치환술을 주(主)로 한 판막치환술의 임상성적)

  • 박동욱;황윤호;최강주;최석철;조광현
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.262-269
    • /
    • 1999
  • Background: To review the middle and long term results of aortic valve replacement(AVR) for 11 years, we surveyed and followed up the patients who underwent AVR. Material and Method: Between Feb. 1986 and May 1997, 134 patients underwent AVR. The patients consisted of 71 men and 63 women whose mean age was 38.9 years, ranging from 17 to 70. Result: The concomitant operations were 62 mitral valve replacement(MVR), 14 MVR + tricuspid valve annuloplasty, 10 Cabrol operation, 16 aortic annulus widening, and so forth. We used 119 mechanical(75 St. Jude Medical, 38 CarboMedics, 6 Sorin) and 15 tissue (Carpentier-Edwards) valves. Early postoperative complications occurred in 35 cases; 9 congestive heart failure, 6 low cardiac output, 5 postoperative bleeding, 5 pleural effusion, and so forth. There were 13 early postoperative deaths(9.7%) due to low cardiac output(5), CHF (2), disseminated intravascular coagulopathy(2), and so forth. The cumulative total follow-up period was 452.7 patient-years with a mean of 3.4${\pm}$3.1 years/patient. There were 9 cases of valve-related complications; anticoagulant-related bleeding(4), prosthetic valve endocarditis(2), thromboembolism(2) and prosthetic valve failure(1) occured at rate of 0.9, 0.4, 0.4, 0.2%/ pt-yr, respectively. Late valve-related death occurred in 3 cases(2.0%/pt-yr) associated with anticoagulant-related bleeding(2) and prosthetic valve endocarditis(1). Conclusion: Actuarial survival rate by Kaplan-Meier method was 91.0${\pm}$4.3 % at 11 years.

  • PDF

Mid-Term Results of Mitral Valve Repair Using a Partial Flexible Band and a Completely Rigid Ring in Patients with Degenerative Mitral Regurgitation (퇴행성 승모판막역류 환자에서 Partial Flexible Band와 Complete Rigid Ring을 이용한 승모판막 성형술의 중기 결과 비교)

  • Kim, Kyung-Hwan;Ahn, Hyuk;Hwang, Ho-Young;Choi, Jin-Ho;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.475-481
    • /
    • 2010
  • Background: We evaluated mid-term results of mitral annuloplasty using a flexible band and a completely rigid ring for mitral valve repair in patients with degenerative mitral regurgitation (MR). Material and Method: From January 2004 to September 2008, 71 patients (M:F=36:35, $55{\pm}13$ years) underwent mitral valve repair with mitral annuloplasty for degenerative MR. Ring annuloplasty was done using a Cosgrove-Edwards flexible band (Group I, n=43) or a Carpentier-Edwards classic ring (Group II, n=28). There were no differences in preoperative characteristics of the participants. Average duration of follow-up was 36 months (range: 2~69 mos). Result: There was no in-hospital mortality. Postoperative morbidity, which included atrial fibrillation (n=7) and low cardiac output syndrome (n=5) in groups I and II were similar. There was one late death in group II. The proportion exhibiting freedom from recurrent mitral regurgitation ($\geq$moderate) at 4 years in Groups I and II were, respectively, 94.5 and 91.8%, (p=0.695). Left ventricular ejection fraction decreased in the early postoperative period ($7{\pm}2$ days) and recovered by last follow-up ($25{\pm}16$ mos; p=0.002). The pattern was similar in groups I and II (p=0.905). Re-operation was performed in 3 patients (1 in Group I and 2 in Group II, p=0.316). Four-year event-free survival (free of adverse valve-related events) was 95.2% for Group I and 92.6% for Group II; this difference was not significant, p=0.646). Conclusion: The type of technique used in mitral annuloplasty to repair the mitral valve repair after degenerative MR did not affect mid-term clinical and functional results.

Mitral Valve Repair for Congenital Mitral Regurgitation in Children (선천성 승모판막 페쇄부전증이 있는 소아에서 승모판막 성형술에 대한 임상적 고찰)

  • Kim, Kun-Woo;Choi, Chang-Hyu;Park, Kook-Yang;Jung, Mi-Jin;Park, Chul-Hyun;Jeon, Yang-Bin;Lee, Jae-Ik
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.292-298
    • /
    • 2009
  • Background: Surgery for mitral valve disease in children carries both technical and clinical difficulties that are due to both the wide spectrum of morphologic abnormalities and the high incidence of associated cardiac anomalies. The purpose of this study is to assess the outcome of mitral valve surgery for treating congenital mitral regurgitation in children. Material and Method: From 1997 to 2007, 22 children (mean age: 5.4 years) who had congenital mitral regurgitation underwent mitral valve repair. The median age of the patients was 5.4 years old and four patients (18%) were under 12 months of age. 15 patients (68%) had cardiac anomalies. There were 13 cases of ventricular septal defect, 1 case of atrial septal defect and 1 case of supravalvar aortic stenosis. The grade of the preoperative mitral valve regurgitation was II in 4 patients, III in 15 patients and IV in 3. The regurgitation was due to leaflet prolapse in 12 patients, annular dilatation in 4 patients and restrictive leaflet motion in 5 patients. The preoperative MV Z-value and the regurgitation grade were compared with those obtained at follow-up. Result: MV repair was possible in all the patients. 19 patients required reduction annuloplasty and 18 patients required valvuloplasty that included shortening of the chordae, papillary muscle splitting, artificial chordae insertion and cleft closure. There were no early or late deaths. The mitral valve regurgitation after surgery was improved in all patients (absent=10, grade I=5, II=5, III=2). MV repair resulted in reduction of the mitral valve Z-value ($2.2{\pm}2.1$ vs. $0.7{\pm}2.3$, respectively, p<0.01). During the mid-term follow-up period of 3.68 years, reoperation was done in three patients (one with repair and two with replacement) and three patients showed mild progression of their mitral reguration. Conclusion: our experience indicates that mitral valve repair in children with congenital mitral valve regurgitation is an effective and reliable surgical method with a low reoperation rate. A good postoperative outcome can be obtained by preoperatively recognizing the intrinsic mitral valve pathophysiology detected on echocardiography and with the well-designed, aggressive application of the various reconstruction techniques.

Surgical Treatment of Atrioventricular Septal Defect (방실중격결손증의 외과적 치료)

  • 이광숙
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.990-995
    • /
    • 1989
  • Since 1984, 24 patients underwent repair of atrioventricular septal defect. Nineteen had a partial defect and 5 had a complete atrioventricular septal defect. There were 9 men and 15 women, ranging in age from 1 to 50 years [mean age, 13.3 years]. Four patients had a Downs syndrome. Additional congenital heart defects were present in 11 patients. One patient had palliative operation prior to total correction. In partial defects, the primum atrial septal defect was closed with Xenomedica patch and the mitral valve was repaired with simple closure of the septal commissure. Central incompetence from annular dilatation was repaired by a local annuloplasty. In complete defect, the septal defects were closed with two patches except one. Operative mortality was 5% in partial defects and 60% in complete defects and low cardiac output was the commonest etiology. In a mean follow-up period of 27.9 months [range, 4 to 63 months] there were no late death and no instances of late-onset complete heart block. One patient required reoperation [MVR] for residual mitral regurgitation. The majority of patients were asymptomatic and mean postop. NYHA functional class was 1.2.

  • PDF

Surgical Outcomes of Congenital Atrial Septal Defect Using da VinciTM Surgical Robot System

  • Kim, Ji Eon;Jung, Sung-Ho;Kim, Gwan Sic;Kim, Joon Bum;Choo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.46 no.2
    • /
    • pp.93-97
    • /
    • 2013
  • Background: Minimally invasive cardiac surgery has emerged as an alternative to conventional open surgery. This report reviews our experience with atrial septal defect using the da VinciTM surgical robot system. Materials and Methods: This retrospective study included 50 consecutive patients who underwent atrial septal defect repair using the da VinciTM surgical robot system between October 2007 and May 2011. Among these, 13 patients (26%) were approached through a totally endoscopic approach and the others by mini-thoracotomy. Nineteen patients had concomitant procedures including tricuspid annuloplasty (n=10), mitral valvuloplasty (n=9), and maze procedure (n=4). The mean follow-up duration was $16.9{\pm}10.4$ months. Results: No remnant interatrial shunt was detected by intraoperative or postoperative echocardiography. The atrial septal defects were mainly repaired by Gore-Tex patch closure (80%). There was no operative mortality or serious surgical complications. The aortic cross clamping time and cardiopulmonary bypass time were $74.1{\pm}32.2$ and $157.6{\pm}49.7$ minutes, respectively. The postoperative hospital stay was $5.5{\pm}3.3$ days. Conclusion: The atrial septal defect repair with concomitant procedures like mitral valve repair or tricuspid valve repair using the da VinciTM system is a feasible method. In addition, in selected patients, complete port access can be helpful for better cosmetic results and less musculoskeletal injury.