• 제목/요약/키워드: Cardiac pacing

검색결과 45건 처리시간 0.027초

흰쥐의 심장을 이용한 Modified Isolated Working Heart Perfusion Technique (Perfusion Techniques Using the Modified Isolated Working Rat Heart Model)

  • 이종국;최형호
    • Journal of Chest Surgery
    • /
    • 제13권4호
    • /
    • pp.338-345
    • /
    • 1980
  • We have modified an isolated perfusion rat heart model of cardiopulmonary bypass, with which we are able to screen the effects of various cardioplegic solutions and hypothermia upon the ability of the heart to survivie during and recover from period of ischemic arrest. The modified experimental model was differed from the original as follow : a heat coil chamber of atrial and aortic reservoir provided temperature control, and the perfusate was gassed with each pure oxygen and pure carbon dioxide in 95:5 ratio. The Langendorff perfusion was initiated for a 10 minute period by introducing perfusate at $37^{\circ}C.$ into the aorta from the aortic reservoir located 100 cm above the heart. The isolated perfused working rat heart model was a left heart preparation in which oxygenated perfusion medium (at $37^{\circ}C.$) entered the cannulated left atrium at a pressure of 20 cm $H_{2}O$ and was passed to the ventricle, from which it was sponeously elected(no electrical pacing) via an aortic cannula, against a hydrostatic pressure of 100cm $H_{2}O$. during this working period various indices of cardiac functin were measured. The cardiac functions were stable for over 3 hour with perfusion of Krebs-Henseleit bicarbonate buffer solution containing only glucose (11.1 mM/L). The percentage of cardiac functins were maintained about 94% on heart rate, 80.6% on peak aortic pressure, 87.7% on coronary flow and 76.3% on aortic flow rate after 3 hour of working heart perfusion at a pressure of 20 cm $H_{2}O$. We believe this preparation to be a good biochemical model for the human heart which offers many advantages including economic, speed of preparation, reproducibility, and the ability to handle large numbers.

  • PDF

Testing of Common Electromagnetic Environments for Risk of Interference with Cardiac Pacemaker Function

  • Tiikkaja, Maria;Aro, Aapo L.;Alanko, Tommi;Lindholm, Harri;Sistonen, Heli;Hartikainen, Juha E.K.;Toivonen, Lauri;Juutilainen, Jukka;Hietanen, Maila
    • Safety and Health at Work
    • /
    • 제4권3호
    • /
    • pp.156-159
    • /
    • 2013
  • Background: Cardiac pacemakers are known to be susceptible to strong electromagnetic fields (EMFs). This in vivo study investigated occurrence of electromagnetic interference with pacemakers caused by common environmental sources of EMFs. Methods: Eleven volunteers with a pacemaker were exposed to EMFs produced by two mobile phone base stations, an electrically powered commuter train, and an overhead high voltage transmission lines. All the pacemakers were programmed in normal clinically selected settings with bipolar sensing and pacing configurations. Results: None of the pacemakers experienced interference in any of these exposure situations. However, often it is not clear whether or not strong EMFs exist in various work environments, and hence an individual risk assessment is needed. Conclusions: Modern pacemakers are well shielded against external EMFs, and workers with a pacemaker can most often return to their previous work after having a pacemaker implanted. However, an appropriate risk assessment is still necessary after the implantation of a pacemaker, a change of its generator, or major modification of its programming settings.

완전방실차단을 동반한 감염성 심내막염 환자에서 판막치환술 후 관정맥동을 통해 좌심실을 조율하는 심박조율기 시술 (Implantation of a permanent pacemaker through the coronary sinus in a patient who underwent mechanical valve replacement for infective endocarditis with a complete atrioventricular block)

  • 조관훈;김인호;안서희;오용석
    • Journal of Yeungnam Medical Science
    • /
    • 제31권2호
    • /
    • pp.113-116
    • /
    • 2014
  • A 52-year-old man was referred to our hospital due to fever and myalgia that occurred 2 weeks earlier. He showed a complete atrioventricular block on his electrocardiogram, and his vital signs were unstable. On his transthoracic echocardiograph, the 1.5 cm vegetation in the aortic valve with severe aortic regurgitation suggested infective endocarditis. His transesophageal enchocardiograph showed abscess in his mitral-aortic intervalvular fibrosa and vegetation was suspected on his anterior mitral valve leaflet. The patient underwent an emergent operation for valve replacement with temporary epicardial pacing. Intraoperatively, the septal leaflet of his tricuspid valve was injured during the debridement of the abscess pocket that was extended to the membranous septum. The aortic, mitral, and tricuspid mechanical valves were replaced with annular reconstruction without complications. After 14 days of intravenous antibiotics, we successfully changed the epicardial pacemaker into a transvenous DDD-type permanent pacemaker by placing a left ventricular lead via the coronary sinus and an atrial lead in the right atrium appendage. The patient was discharged in a tolerable state and was examined uneventfully in our hospital's outpatient clinic for 8 months.

영구 경정맥 심박조율기 도자에 의한 우심실 천공과 좌측 혈흉 -1예 보고- (Right Ventricular Perforation and Left Hemothorax by Permanent Transveneous Pacemaker Lead - Report of 1 Case-)

  • 김재현;김근직;오삼세;백만종;김종환;나찬영
    • Journal of Chest Surgery
    • /
    • 제38권4호
    • /
    • pp.312-315
    • /
    • 2005
  • 심내막 심박조율기 이식 후 도자에 의한 심장 천공으로 출혈이 발생하는 경우는 드물다. 본원에서는 영구 경정맥 심박조율기 이식 후 우심실 천공에 의한 좌측 혈흉이 발생하였던 환자를 경험하였기에 보고하는 바이다. 수술 소견 상 심박조율기 도자가 우심실 천공 후 심낭막과 흉막을 차례로 관통하였으나 혈심낭 소견은 관찰되지 않았다.

약물의 염전성 부정맥 유발 예측 지표로서 심장의 전기생리학적 특징 값들의 검증 (Verification of Cardiac Electrophysiological Features as a Predictive Indicator of Drug-Induced Torsades de pointes)

  • 유예담;정다운;;임기무
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권1호
    • /
    • pp.19-26
    • /
    • 2022
  • The Comprehensive in vitro Proarrhythmic Assay(CiPA) project was launched for solving the hERG assay problem of being classified as high-risk groups even though they are low-risk drugs due to their high sensitivity. CiPA presented a protocol to predict drug toxicity using physiological data calculated based on the in-silico model. in this study, features calculated through the in-silico model are analyzed for correlation of changing action potential in the near future, and features are verified through predictive performance according to drug datasets. Using the O'Hara Rudy model modified by Dutta et al., Pearson correlation analysis was performed between 13 features(dVm/dtmax, APpeak, APresting, APD90, APD50, APDtri, Capeak, Caresting, CaD90, CaD50, CaDtri, qNet, qInward) calculated at 100 pacing, and between dVm/dtmax_repol calculated at 1,000 pacing, and linear regression analysis was performed on each of the 12 training drugs, 16 verification drugs, and 28 drugs. Indicators showing high coefficient of determination(R2) in the training drug dataset were qNet 0.93, AP resting 0.83, APDtri 0.78, Ca resting 0.76, dVm/dtmax 0.63, and APD90 0.61. The indicators showing high determinants in the validated drug dataset were APDtri 0.94, APD90 0.92, APD50 0.85, CaD50 0.84, qNet 0.76, and CaD90 0.64. Indicators with high coefficients of determination for all 28 drugs are qNet 0.78, APD90 0.74, and qInward 0.59. The indicators vary in predictive performance depending on the drug dataset, and qNet showed the same high performance of 0.7 or more on the training drug dataset, the verified drug dataset, and the entire drug dataset.

Late Outcomes of Pediatric and Congenital Heart Disease Patients Following Cardiac Resynchronization Therapy

  • Jeong Eun Ahn;Susan Taejung Kim;Hye Won Kwon;Sang Yun Lee;Gi Beom Kim;Jae Gun Kwak;Woong Han Kim;Mi Kyoung Song;Eun Jung Bae
    • Korean Circulation Journal
    • /
    • 제52권12호
    • /
    • pp.865-875
    • /
    • 2022
  • Background and Objectives: Cardiac resynchronization therapy (CRT) is an effective treatment for heart failure. However, in pediatric and congenital heart disease (CHD) patients, current adult indications cannot be directly applied because of heterogeneity in anatomy and diagnosis. Therefore, CRT responses and clinical outcomes in these patients were investigated to derive possible candidates for CRT. Methods: This study retrospectively analyzed 16 pediatric and CHD patients who underwent CRT implantation at a single center in early (0.7±0.2 year) and late (4.7±0.3 years) follow-up period after CRT. Results: The median age at CRT implantation was 2.5 (0.3-37.2) years, and median follow-up duration was 6.3 (0.1-13.6) years. Thirteen had non-transvenous CRT. Two had congenital complete atrioventricular (AV) block with previous right ventricular pacing, 5 had dilated cardiomyopathy (DCM) with left bundle branch block, and 9 had CHD. The mean ejection fraction of the systemic ventricle increased from 28.1±10.0% to 44.3±21.0% (p=0.003) in early and 51.8±16.3% (p=0.012) in late outcome. The mean functional class improved from 3.1±0.9 to 1.8±1.1 after CRT (p=0.003). Twelve patients (75%) showed improvement in ventricular function or functional class after CRT. Proportion of responders differed between patients without CHD (2/2 patients with complete AV block and 5/5 with DCM, 100%) and those with CHD (5/9, 56%), although statistical significance was not reached (p=0.088). Conclusions: CRT improved ventricular function and functional status according to the underlying condition in pediatric and CHD patients. However, further large and longer-term studies are needed to establish the guideline for the patient selection of CRT in these patients.

승모판치환술 후에 발생한 아미오다론에 의한 급성호흡곤란증훈군 -1례 보고- (Amiodarone-Induced ARDS after MVR -A case report-)

  • 이기복;김응중;지현근;신윤철
    • Journal of Chest Surgery
    • /
    • 제35권8호
    • /
    • pp.594-598
    • /
    • 2002
  • 아미오다론은 일반적인 항부정백 약물로 잘 치료되지 않는 상심실성 부정맥이나 심실성 부정맥의 치료에 효과적이라고 알려져 있는 요오드화된 벤조푸루란 유도체이다. 아미오다론으로 치료받은 환자들에게서, 속발되는 수술적 치료는 흔히 동반되는 과정이지만, 애석하게도 아미오다론으로 수술중과 수술후에 야기될 수 있는 합병증에 대해서 정확한 자료를 가지고 있지 못한 것이 현실이다. 일부 보고들에 따르면, 아미오다론으로 치료받던 환자들에게서 알파 교감 수용체와 베타 교감 수용체에 차단을 야기하고, 이는 수술후 혈역학적 지지에 더 많은 심근 자극과 에피네프린등의 약물을 필요로 하게 된다고 알려져 있다. 또한, 심각한 사망률과 유병율을 야기하는 아주 심각한 형태의 급성호흡부전증을 야기하게 된다고 알려져 있다. 본 교실은 승모판막치환술 후에 아미오다론으로 인하여 유발된 급성호흡부전증으로 사망한 환자를 경험하였기에 간략한 문헌고찰과 함께 보고하는 바이다.

활로 4징증의 근치수술후의 원격 방실전도 차단 (Complete A-V Block 3 Months after Total Correction of Tetralogy of Fallot)

  • 송요준
    • Journal of Chest Surgery
    • /
    • 제11권3호
    • /
    • pp.326-332
    • /
    • 1978
  • There appears some conduction defects frequently after total correction of Tetralogy of Fallot. Common defect is right bundle branch block due to surgical intervention. We experienced complete A-V block which occured 3 months later after total correction of Tetralogy of Fallot in a 8 year old boy. The patient was completely free of any A-V block after the operation for 3 months, and sudden onset of A-V block with coupled premature ventricular contractions resulted him in shock state during the attack of severe bronchopneumonia for 4 days prior to the second visit. Emergency implantation of Cordis demand type temporary pacemaker was necessary to control the complete heart block with bradyarrhythmia and frequent ventricular fibrillation. Permanent cardiac pacemaker was implanted two weeks later as indicated with Cordis Stanicor lambda demand pacemaker, and the patient was discharged uneventfully on the 8th post implantation day with the heart rate of 72/min. Another 3 months after the implantation, the patient was transported to this hospital as dead on arrival after an accidental fall from a 2 meter height, and all possible cardiopulmonary resuscitation was performed for 60 minutes at the emergency room in vain. Autopsy was done to find out the cause of sudden death and the etiology of complete heart block. Microscopic focal infarctions with scar formation were noted along the course of conduction system in the interventricular septum, which might be the main cause of complete heart block during the attack of severe bronchopneumonia complicated with acute bacterial endocarditis. The tip of the pacemaker wire was slipped from the granulation scar at the apex of the right ventricular cavity, and this might be the direct cause of pacing failure and death.

  • PDF

노출된 영구 심박조율기의 치험례 (Clinical Experience of Exposed Pacemakers)

  • 오득영;김태형;이종원;이백권;한기택;안상태;최윤석
    • Archives of Plastic Surgery
    • /
    • 제32권6호
    • /
    • pp.753-756
    • /
    • 2005
  • In the cases of severe arrythmia and conduction failure, a permanent implanted pacemaker is considered an essential treatment modality with less complication rate, broad indications and low morbidity. However, some pacemakers needs to be removed or replaced due to infection, in need of a lead upgrade, elective replacement, conduction failure or insulation failure. The most common indication for pacemaker extraction is infection. Conservative treatments such as administration of intravenous antibiotics and limitation of debridement are not effective and the removal of the entire pacing system is considered to be the best approach to pacemaker pocket infection. Although a locking stylet, a laser sheath and other newer methods of transvenous lead extraction have been proven to be effective, all leads cannot be removed. Moreover, major complications such as, cardiac tamponade and respiratory arrest during leads extraction procedure should not be ignored. We experienced two cases of exposed pacemakers in the subclavicular region. After removing the pacemaker body, exposed proximal lead was pulled out and cut off. The end of remnant external insulation tube was tied to prevent infection propagation between external insulation tube and inner metalic coil. Wounds were covered by local flap coverage. No other problems were detected during the one-year follow-up. Since there are few reports on lead-preserving method of treating limited infection of exposed pacemakers, we would like to present our new method for treating exposed pacemakers.

단심실 -III C Solitus 형의 수술치험- (Surgical Repair of Single Ventricle (Type III C solitus))

  • naf
    • Journal of Chest Surgery
    • /
    • 제12권3호
    • /
    • pp.281-288
    • /
    • 1979
  • For years, physicians and anatomists have been interested in the heart that has one functioning ventricle. Various terms have been suggested for this entity including single ventricle, common ventricle, double-inlet left ventricle, cor biatriatum triloculare, and primitive ventricle. In this report, the term "single ventricle" is utilized as suggested by Van Praagh, and is defined as that congenital cardiac anomaly in which a common or separate atrioventricular valves open into a ventricular chamber from which both great arterial trunks emerge. An outlet chamber, or infundibulum, may or may not be present and give rise to the origin of either of the great arteries. This definition excludes the entity of mitral and tricuspid atresia. An 11 year old cyanotic boy was admitted chief complaints of exertional dyspnea and frequent upper respiratory infection since 2 weeks after birth. He was diagnosed as inoperable cyanotic congenital heart disease, and remained without any corrective treatment up to his age of 11 year when he suffered from aggravation of symptoms and signs of congestive heart failure for 2 months before this admission. On 22nd of May 1979, he was admitted for total corrective operation under the impression of tricuspid atresia suggested by a pediatrician. Physical check revealed deep cyanosis with finger and toe clubbing, and grade V systolic ejection murmur with single second heart sound was audible at the left 3rd intercostal space. Development was moderate in height [135 cm] and weight[28Kg]. Routine lab findings were normal except increased hemoglobin [21.1gm%], hematocrit [64 %], and left axis deviation with left ventricular hypertrophy on EKG. Cardiac catheterization and angiography revealed 1-transposition of aorta, pulmonic valvular stenosis, double inlet of a single ventricle with d-loop, and normal atriovisceral relationship [Type III C solitus according to the classification of Van Praagh]. At operation, longitudinal incision at the outflow tract of right ventricle in between the right coronary artery and its branch [LAD from RCA] revealed high far anterior aortic valve which had fibrous continuity with mitral annulus, and pulmonic valve was stenotic up to 4 mm in diameter positioned posterolaterally to the aorta. Ventricular septum was totally defective, and one markedly hypertrophied moderator band originated from crista supraventricularis was connected down to the imaginary septum of the ventricular cavity as a pseudoseptum of the ventricle. Size of the defect was 3X3 cm2 in total. Patch closure of the defect with a Teflon felt of 3.5 x 4 cm2 was done with interrupted multiple sutures after cut off of the moderator band, which was resutured to the artificial septum after reconstruction of the ventricular septum. Pulmonic valvotomy was done from 4 mm to 11 mm in diameter thru another pulmonary arteriotomy incision, and right ventriculotomy wound was closed reconstructing the right ventricular outflow tract with pericardial autograft of 3 x 4 cm2. Atrial septal defect of 2 cm in diameter was closed with 3-0 Erdeck suture, and atrial wall was sutured also when rectal temperature reached from 24`C to 35.5`C. Complete A-V block was managed with temporary external pacemaker with a pacing rate of 110/min. thru myocardial wire, and arterial blood pressure of 80/50 mmHg was maintained with Isuprel or Dopamine dripping under the CVP of 25-cm saline. Consciousness was recovered one hour after the operation when his blood pressure reached 100 /70 mmHg, but vital signs were not stable, and bleeding from the pericardial drainage and complete anuria were persisted until his heart could not capture the pacemaker impulse, and patient died of low output syndrome 320 min after the operation.

  • PDF