• 제목/요약/키워드: Cardiac magnetic resonance image

검색결과 29건 처리시간 0.026초

Fast Real-Time Cardiac MRI: a Review of Current Techniques and Future Directions

  • Wang, Xiaoqing;Uecker, Martin;Feng, Li
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.252-265
    • /
    • 2021
  • Cardiac magnetic resonance imaging (MRI) serves as a clinical gold-standard non-invasive imaging technique for the assessment of global and regional cardiac function. Conventional cardiac MRI is limited by the long acquisition time, the need for ECG gating and/or long breathhold, and insufficient spatiotemporal resolution. Real-time cardiac cine MRI refers to high spatiotemporal cardiac imaging using data acquired continuously without synchronization or binning, and therefore of potential interest in overcoming the limitations of conventional cardiac MRI. Novel acquisition and reconstruction techniques must be employed to facilitate real-time cardiac MRI. The goal of this study is to discuss methods that have been developed for real-time cardiac MRI. In particular, we classified existing techniques into two categories based on the use of non-iterative and iterative reconstruction. In addition, we present several research trends in this direction, including deep learning-based image reconstruction and other advanced real-time cardiac MRI strategies that reconstruct images acquired from real-time free-breathing techniques.

Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI

  • Chen Cui;Gang Yin;Minjie Lu;Xiuyu Chen;Sainan Cheng;Lu Li;Weipeng Yan;Yanyan Song;Sanjay Prasad;Yan Zhang;Shihua Zhao
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.114-125
    • /
    • 2019
  • Objective: Segmented cardiac cine magnetic resonance imaging (MRI) is the gold standard for cardiac ventricular volumetric assessment. In patients with difficulty in breath-holding or arrhythmia, this technique may generate images with inadequate quality for diagnosis. Real-time cardiac cine MRI has been developed to address this limitation. We aimed to assess the performance of retrospective electrocardiography-gated real-time cine MRI at 3T for left ventricular (LV) volume and mass measurement. Materials and Methods: Fifty-one patients were consecutively enrolled. A series of short-axis cine images covering the entire left ventricle using both segmented and real-time balanced steady-state free precession cardiac cine MRI were obtained. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass were measured. The agreement and correlation of the parameters were assessed. Additionally, image quality was evaluated using European CMR Registry (Euro-CMR) score and structure visibility rating. Results: In patients without difficulty in breath-holding or arrhythmia, no significant difference was found in Euro-CMR score between the two techniques (0.3 ± 0.7 vs. 0.3 ± 0.5, p > 0.05). Good agreements and correlations were found between the techniques for measuring EDV, ESV, EF, SV, and LV mass. In patients with difficulty in breath-holding or arrhythmia, segmented cine MRI had a significant higher Euro-CMR score (2.3 ± 1.2 vs. 0.4 ± 0.5, p < 0.001). Conclusion: Real-time cine MRI at 3T allowed the assessment of LV volume with high accuracy and showed a significantly better image quality compared to that of segmented cine MRI in patients with difficulty in breath-holding and arrhythmia.

Guidelines for Cardiovascular Magnetic Resonance Imaging from the Korean Society of Cardiovascular Imaging (KOSCI) - Part 3: Perfusion, Delayed Enhancement, and T1- and T2 Mapping

  • Im, Dong Jin;Hong, Su Jin;Park, Eun-Ah;Kim, Eun Young;Jo, Yeseul;Kim, Jeong Jae;Park, Chul Hwan;Yong, Hwan Seok;Lee, Jae Wook;Hur, Jee Hye;Yang, Dong Hyun;Lee, Bae-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권1호
    • /
    • pp.1-20
    • /
    • 2020
  • This document is the third part of the guidelines for the interpretation and post-processing of cardiac magnetic resonance (CMR) studies. These consensus recommendations have been developed by a Consensus Committee of the Korean Society of Cardiovascular Imaging (KOSCI) to standardize the requirements for image interpretation and post-processing of CMR. This third part of the recommendations describes tissue characterization modules, including perfusion, late gadolinium enhancement, and T1- and T2 mapping. Additionally, this document provides guidance for visual and quantitative assessment, consisting of "What-to-See," "How-To," and common pitfalls for the analysis of each module. The Consensus Committee hopes that this document will contribute to the standardization of image interpretation and post-processing of CMR studies.

심장 자기공명영상 (Cardiac MRI)

  • 이종민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권1호
    • /
    • pp.1-9
    • /
    • 2007
  • 심장의 영상화에 장애가 되는 요인은 심장 운동, 호흡, 심장 내 혈류 등에 의한 인공물(artifact) 과 심장 조직의 용적이 작음으로 인한 낮은 신호 대 잡음비 등이 있다. 심장 운동에 의한 화질 저하를 막기 위해 신속영상기법(fast imaging technique) 을 이용하여 심장 운동의 특정 위상(phase) 에서만 영상을 얻는 심장동기(cardiac gating) 방법을 이용하고 있다. MRI를 이용한 심장의 검사는 심장의 형태, 심실 기능, 심근 관류, 심근 대사, 관상동맥 영상 등을 대상으로 한다. 심장의 형태적 진단에 있어서 심근내 수분의 정도와 지방조직을 보기 위해 이중(double) 혹은 삼중역전회복기법(triple inversion recovery technique) 을 사용한다. 심근관류검사를 위해서는 조영증강신속경사에코법(contrast-enhanced fast gradient echo technique)을 사용하여 일차통과조영증강(first-pass enhancement) 을 검사한다. 또한 10-15분 지연영상을 얻어 심근내 조영제의 재분포를 검사하여 만성심근경색 등의 심근파괴부위를 확인한다. 심실기능 평가를 위해서는 신속경사에 코법을 이용한 영화영상(cine image) 이 사용되며 심실의 국소적 운동이상 및 심실기능의 정량적 검사가 가능하다. MRI는 관상동맥영상을 제외한 포괄적 심장검사에 실용성이 있다. 특히 지연영상은 다른 검사장비에선 얻을수 없는 유용한 정보이다.

  • PDF

MR PC 영상을 이용한 유체 흐름 분석 (Measurement of Flow Velocity and Flow Visualization with MR PC Image)

  • 김수정;이동혁;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.127-130
    • /
    • 1997
  • Phase-contrast(PC) methods have been used for quantitative measurements of velocity and volume flow rate. In addition, phase contrast cine magnetic resonance imaging (MRI) combines the flow dependent contrast of PC MRI with the ability of cardiac cine imaging to produce images throughout the cardiac cycle. In this method, the through-plane velocity has been encoded generally. However, the accuracy of the flow data can be reduced by the effect of flow direction, finite slice thickness, resolution, pulsatile flow pattern, and so on. In this study we calculated the error caused by misalignment of tomographic plane and flow directon. To reduce this error and encode the velocity for more complex flow, we suggested 3 directional velocity encoding method.

  • PDF

Study on Image Improvement Method for Coronary Artery Imaging

  • 류연철;류승학;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.142-142
    • /
    • 2001
  • 목적: 관상동맥의 이상으로 인해 여러 가지 심장 관련 질환이 발병하기 때문에 관상동맥을 관찰할 수 있는 영상기법의 필요성이 늘어남은 물론 세계적으로 Cardiac 영상 기법 개발이 활발하게 진행되어 지고 있다. MRI System을 이용한 관상동맥(Coronary Artery) Image는 여러 가지 움직임 때문에 사용할 수 있는 영상기법에 제한을 받게 된다 가장 큰 제약은 심장의 움직임에 관한 것인데 이러한 움직임은 ECG Gating을 사용하여 극복할 수 있다. 본 논문에서는 관상 동맥을 촬영하는 영상기법의 개발과 촬영된 영상을 재처리하는 기법을 소개 하고자 한다 ECG Gating을 이용한 영상 기법 및 얻어진 영상을 Morphology, MIP를 이용한 Image processing을 하여 얻어진 영상을 enhance시켜 보았다.

  • PDF

MRI용 심전도/혈류 게이팅 시스템 설계 (Design of ECG/PPG Gating System in MRI Environment)

  • 장봉렬;박호동;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.132-138
    • /
    • 2007
  • MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchronizes the MRI sequence acquisition to the R-wave in order to eliminate image motion artifacts. In this paper, we designed ECG/PPG(photo-plethysmography) gating system which is for eliminating motion artifacts due to moving organ. This system uses nonmagnetic carbon electrodes, lead wire and shield case for minimizing RF(radio-frequency) pulse and gradient effect. Also, we developed a ECG circuit for preventing saturation by magnetic field and a finger plethysmography sensor using optic fiber. And then, gating pulse is generated by adaptive filtering based on NLMS(normalized least mean square) algorithm. To evaluate the developed system, we measured and compared MR imaging of heart and neck with and without ECG/PPG gating system. As a result, we could get a clean image to be used in clinically. In conclusion, the designed ECG/PPG gating system could be useful method when we get MR imaging of moving organ like a heart.

고주파 차폐용 Mesh를 이용한 자기공명영상 분석 (Magnetic Resonance Image Analysis using MESH for High-frequency Shielding)

  • 신운재
    • 한국방사선학회논문지
    • /
    • 제15권7호
    • /
    • pp.975-982
    • /
    • 2021
  • 본 연구는 체내의 식도용 스텐트와 일플란트에 많이 사용되는 티타늄 성분의 금속성 물질을 사용하여 구리와 black metal, polyester로 구성된 머리카락 보다 가늘게 제작된 mesh로 시험관을 부분적으로 RF를 차폐하여 주변에 위치한 자기공명영상용 팬텀에 미치는 영향을 평가하고자 하였다. 3T Achieva X-series의 Cardiac Coil을 사용하여 TR 500 ms, TE 20 ms, NEX 1, slice thickness 5 mm의 Spin Echo T1강조영상에서 field of view(FOV)에 따른 자기공명영상을 분석하였다. FOV 304 mm × 304 mm에서는 발생하지 않았던 aliasing artifact가 발생하지 않았지만 250 mm × 250 mm 과 170 mm × 170 mm에서는 발생되었다. FOV 170 mm × 170 mm에서 mesh를 사용하지 않은 경우는 SNR이 78.23으로 가장 낮았으며, mesh를 가운데 세워 분리한 경우에는 215.05, mesh로 완전히 차폐한 경우에는 366.44로 높게 측정되었다. 또한 mesh로 완전히 감싸고 차폐한 경우에는 aliasing artifact도 제거되었고, 영상의 왼쪽과 가운데, 오른쪽의 신호 대 잡음비가 높으면서 다른 조건과 비교하여 균질한 영상을 획득할 수 있었다. 결론적으로 mesh로 RF를 부분적으로 감싸고 차단하면 aliasing artifact를 제거할 수 있고, 작은 FOV를 사용하여 영상의 해상도와 균질성이 우수한 자기공명영상을 획득할 수 있을 것으로 사료된다.

Feasibility of Free-Breathing, Non-ECG-Gated, Black-Blood Cine Magnetic Resonance Images With Multitasking in Measuring Left Ventricular Function Indices

  • Pengfei Peng;Xun Yue;Lu Tang;Xi Wu;Qiao Deng;Tao Wu;Lei Cai;Qi Liu;Jian Xu;Xiaoqi Huang;Yucheng Chen;Kaiyue Diao;Jiayu Sun
    • Korean Journal of Radiology
    • /
    • 제24권12호
    • /
    • pp.1221-1231
    • /
    • 2023
  • Objective: To clinically validate the feasibility and accuracy of cine images acquired through the multitasking method, with no electrocardiogram gating and free-breathing, in measuring left ventricular (LV) function indices by comparing them with those acquired through the balanced steady-state free precession (bSSFP) method, with multiple breath-holds and electrocardiogram gating. Materials and Methods: Forty-three healthy volunteers (female:male, 30:13; mean age, 23.1 ± 2.3 years) and 36 patients requiring an assessment of LV function for various clinical indications (female:male, 22:14; 57.8 ± 11.3 years) were enrolled in this prospective study. Each participant underwent cardiac magnetic resonance imaging (MRI) using the multiple breath-hold bSSFP method and free-breathing multitasking method. LV function parameters were measured for both MRI methods. Image quality was assessed through subjective image quality scores (1 to 5) and calculation of the contrast-to-noise ratio (CNR) between the myocardium and blood pool. Differences between the two MRI methods were analyzed using the Bland-Altman plot, paired t-test, or Wilcoxon signed-rank test, as appropriate. Results: LV ejection fraction (LVEF) was not significantly different between the two MRI methods (P = 0.222 in healthy volunteers and P = 0.343 in patients). LV end-diastolic mass was slightly overestimated with multitasking in both healthy volunteers (multitasking vs. bSSFP, 60.5 ± 10.7 g vs. 58.0 ± 10.4 g, respectively; P < 0.001) and patients (69.4 ± 18.1 g vs. 66.8 ± 18.0 g, respectively; P = 0.003). Acceptable and comparable image quality was achieved for both MRI methods (multitasking vs. bSSFP, 4.5 ± 0.7 vs. 4.6 ± 0.6, respectively; P = 0.203). The CNR between the myocardium and blood pool showed no significant differences between the two MRI methods (18.89 ± 6.65 vs. 18.19 ± 5.83, respectively; P = 0.480). Conclusion: Multitasking-derived cine images obtained without electrocardiogram gating and breath-holding achieved similar image quality and accurate quantification of LVEF in healthy volunteers and patients.

Blended-Transfer Learning for Compressed-Sensing Cardiac CINE MRI

  • Park, Seong Jae;Ahn, Chang-Beom
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권1호
    • /
    • pp.10-22
    • /
    • 2021
  • Purpose: To overcome the difficulty in building a large data set with a high-quality in medical imaging, a concept of 'blended-transfer learning' (BTL) using a combination of both source data and target data is proposed for the target task. Materials and Methods: Source and target tasks were defined as training of the source and target networks to reconstruct cardiac CINE images from undersampled data, respectively. In transfer learning (TL), the entire neural network (NN) or some parts of the NN after conducting a source task using an open data set was adopted in the target network as the initial network to improve the learning speed and the performance of the target task. Using BTL, an NN effectively learned the target data while preserving knowledge from the source data to the maximum extent possible. The ratio of the source data to the target data was reduced stepwise from 1 in the initial stage to 0 in the final stage. Results: NN that performed BTL showed an improved performance compared to those that performed TL or standalone learning (SL). Generalization of NN was also better achieved. The learning curve was evaluated using normalized mean square error (NMSE) of reconstructed images for both target data and source data. BTL reduced the learning time by 1.25 to 100 times and provided better image quality. Its NMSE was 3% to 8% lower than with SL. Conclusion: The NN that performed the proposed BTL showed the best performance in terms of learning speed and learning curve. It also showed the highest reconstructed-image quality with the lowest NMSE for the test data set. Thus, BTL is an effective way of learning for NNs in the medical-imaging domain where both quality and quantity of data are always limited.