• Title/Summary/Keyword: Cardiac imaging

Search Result 322, Processing Time 0.034 seconds

Vascular ring anomaly with a right patent ductus arteriosus and a left aortic arch in a juvenile cat

  • Aki Takeuchi ;Kazumi Shimada ;Lina Hamabe ;Tomohiko Yoshida;Yusuke Ozai ;Miki Hirose ;Aimi Yokoi ;Momoko Watanabe ;Ikki Mitsui ;Ryou Tanaka
    • Journal of Veterinary Science
    • /
    • v.24 no.4
    • /
    • pp.50.1-50.6
    • /
    • 2023
  • This paper reports the clinical findings and surgical treatment of feline right patent ductus arteriosus (RPDA) with a left aortic arch. A two-month-old female Maine Coon was referred for an investigation of regurgitation after weaning. RPDA with a left aortic arch was diagnosed based on the echocardiographic and computed tomography (CT) findings. A right-fourth intercostal thoracotomy was found to be an appropriate approach to the duct. Preoperative diagnosis is crucial and diagnostic imaging, including radiography, echocardiography, and cardiac CT examination, is essential for determining if the aortic arch is right or left.

Left Atrial Appendage Aneurysm: A Case Report (좌심방 부속기 동맥류: 증례 보고)

  • Young Jae Choi;Jeung Sook Kim;Yoon Ki Cha;Kang Min Han
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1400-1405
    • /
    • 2022
  • Left atrial appendage aneurysm (LAAA) is a rare heart anomaly caused by congenital dysplasia of the pectinate muscle or by an acquired pathological condition of the mitral valve or cardiac muscle. It is often incidentally discovered during chest CT or echocardiography as an abnormal dilatation of the LAA. LAAA is associated with life-threatening complications and most patients require surgical treatment. Therefore, it is important to evaluate associated complications as well as precise diagnoses. This report presents the case of a surgically confirmed LAAA in a 53-year-old female. We also discuss the pathophysiology of LAAA and significant findings related to mortality that can be detected on CT and MRI.

Prognostic Role of Right VentricularPulmonary Artery Coupling Assessed by TAPSE/PASP Ratio in Patients With Acute Heart Failure

  • Youngnam Bok;Ji-Yeon Kim;Jae-Hyeong Park
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.4
    • /
    • pp.200-206
    • /
    • 2023
  • BACKGROUND: Right ventricular (RV) dysfunction is a significant risk of major adverse cardiac events in patients with acute heart failure (AHF). In this study, we evaluated RV-pulmonary artery (PA) coupling, assessed by tricuspid annular plane systolic excursion (TAPSE)/pulmonary artery systolic pressure (PASP) and assessed its prognostic significance, in AHF patients. METHODS: We measured the TAPSE/PASP ratio and analyzed its correlations with other echocardiographic parameters. Additionally, we assessed its prognostic role in AHF patients. RESULTS: A total of 1147 patients were included in the analysis (575 men, aged 70.81 ± 13.56 years). TAPSE/PASP ratio exhibited significant correlations with left ventricular (LV) ejection fraction(r = 0.243, p < 0.001), left atrial (LA) diameter(r = -0.320, p < 0.001), left atrial global longitudinal strain (LAGLS, r = 0.496, p < 0.001), mitral E/E' ratio(r = -0.337, p < 0.001), and right ventricular fractional area change (RVFAC, r = 0.496, p < 0.001). During the median follow-up duration of 29.0 months, a total of 387 patients (33.7%) died. In the univariate analysis, PASP, TAPSE, and TAPSE/PASP ratio were significant predictors of mortality. After the multivariate analysis, TAPSE/PASP ratio remained a statistically significant parameter for all-cause mortality (hazard ratio [HR], 0.453; p = 0.037) after adjusting for other parameters. In the receiver operating curve analysis, the optimal cut-off level of TAPSE/PASP ratio for predicting mortality was 0.33 (area under the curve = 0.576, p < 0.001), with a sensitivity of 65% and a specificity of 47%. TAPSE/PASP ratio < 0.33 was associated with an increased risk of mortality after adjusting for other variables (HR, 1.306; p = 0.025). CONCLUSIONS: In AHF patients, TAPSE/PASP ratio demonstrated significant associations with RVFAC, LA diameter and LAGLS. Moreover, a decreased TAPSE/PASP ratio < 0.33 was identified as a poor prognostic factor for mortality.

Fetal Interventricular Septum Volume Evaluated by Three-Dimensional Ultrasound Using Spatiotemporal Image Correlation and Virtual Organ Computer-Aided Analysis in Fetuses From Pre-Gestational Diabetes Mellitus Pregnant Women

  • Nathalie Jeanne Bravo-Valenzuela;Alberto Borges Peixoto;Rosiane Mattar;Edward Araujo Junior
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.2
    • /
    • pp.125-134
    • /
    • 2022
  • BACKGROUND: To assess the interventricular septum (IVS) volume of fetuses from pre-gestational diabetes mellitus (DM) pregnant women by 3-dimensional ultrasound using spatiotemporal image correlation (STIC) and virtual organ computer-aided analysis (VOCAL) methods. METHODS: This was a prospective cross-sectional study of 45 fetuses from pre-gestational DM and 45 fetuses from healthy pregnant women (controls). Only singleton pregnancies between 20 and 34 + 6 weeks of gestation were included. The fetal IVS volumes were obtained off-line using STIC and VOCAL methods. To analyze differences among variables, the Student's t-test and Mann-Whitney U test were used. The correlation among continuous variables was determine using Spearman's correlation test (r). RESULTS: The median of fetal IVS volume was significantly higher in pre-gestational DM than in healthy pregnant women (0.3 cm3 vs. 0.2 cm3, p = 0.032). A strong positive correlation was observed between fetal IVS volume and gestational age at the time of ultrasound examination (r = 0.75, R2 = 0.48, p < 0.0001) and between fetal IVS volume and estimated fetal weight (r = 0.63, R2 = 0.37, p < 0.0001). No significant correlation was noted between fetal IVS volume and glycated hemoglobin levels (r = -0.16, R2 = 0.01, p = 0.540) in the pre-gestational DM pregnant women. CONCLUSIONS: Significant differences were observed in fetal IVS volumes between pre-gestational and healthy mothers, with higher values in the fetuses of pre-gestational DM pregnant women.

Evaluation of short-term cardiac function by tissue Doppler imaging in pre and postoperative period of congenital heart disease (조직 도플러 영상을 이용한 선천성 심장병 수술 전후의 단기 심기능 평가)

  • Lee, Jun-Hwa;Kim, Yeo-Hyang;Hyun, Myung-Chul;Lee, Sang-Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.5
    • /
    • pp.476-483
    • /
    • 2007
  • Purpose : The objective of this study was to assess ventricular function by tissue Doppler imaging (TDI) in children with congenital heart disease (CHD) who have been undergoing open heart surgery (OHS) using cardiopulmonary bypass. We tried to compare the parameters of tissue Doppler imaging before and after OHS in patients with congenital heart disease. Methods : This study was conducted on 32 patients with CHD after OHS from January 2005 to December 2005 at Kyungpook National University hospital. Patients who underwent 2-D echocardiography before and after their OHS. All patients were divided into three groups, left ventricular volume overloading group (group 1), and right ventricular volume overloading group (group 2), and right ventricular pressure overloading group (group 3). The TDIs were examined before and 1 to 3 months after OHS. Peak early diastolic (E), and peak late diastolic (A) velocity of transmitral flow were measured by pulsed wave Doppler examination. Peak systolic (Sm), peak early diastolic (Em), and peak late diastolic (Am) velocity in apical 4-chamber and 2-chamber views were measured by TDI. The author calculated E/Em ratio. Results : The patients were 14 boys and 18 girls and the average age of patients was 2 years and 3 months. The congenital heart diseases which have to get OHS were ventricular septal defect (13 cases), atrial septal defect (7), atrioventricular septal defect (3), isolated pulmonary stenosis (2) and tetralogy of Fallot (7). There were significant decrease of Sm, Em, Am measured on tricuspid annulus and E/Em measured on mitral annulus in apical 4 chamber view (P<0.05). Conclusion : This study showed significant decrease of Sm, Em, Am measured on tricuspid annulus and E/Em measured on mitral annulus in apical 4 chamber view after OHS. These changes might be due to the effects of cardiopulmonary bypass in OHS and/or hemodynamic changes after correction of congenital heart disease. To clarify these changes, further study on more patients is needed.

Quantitative Analysis of Artifactual Perfusion Defects due to the Cutoff Frequencies of Reconstruction Filters in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT에서 재구성필터의 차단주파수에 의한 인위적 관류결손의 정량적 평가)

  • Kwark, Cheol-Eun;Chung, June-Key;Lee, Myung-Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.231-238
    • /
    • 1995
  • Tc-99m-MIBI (Sestamibi) myocardial SPECT along with TI-201 tomographic Imaging has demonstrated wide application and high image quality sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow. The qualitative values of myocardial SPECT with Tc-99m-MIBI as well ds the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection (FBP) Is the common standard method for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected litter parameters such as cutoff frequencies and order (Butterworth case) The cutoff frequencies used in clinicAl practice partially remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for Identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable threshold of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Wyquist frequency would reveal severe degradation of radioactive distribution near inferior and/or inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

Serum interleukin-6, tumor necrosis factor-α and adiponectin levels in Kawasaki disease (가와사키병 환자의 혈청 interleukin-6, tumor necrosis factor-α, Adiponectin 치에 대한 연구)

  • An, Jung;Kim, Han Gyu;Sohn, Sejung;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.1
    • /
    • pp.41-47
    • /
    • 2010
  • Purpose : Adiponectin is an endogenous modulator of vascular remodeling that suppresses vascular inflammation. However, the role of adiponectin in Kawasaki disease (KD) has not been elucidated. The purpose of this study is to investigate the correlation between serum adiponectin level and several parameters, such as interleukin (IL)-6, tumor necrosis factor $(TNF)-{\alpha}$, lipid profile, and C reactive protein (CRP), and to clarify the association between adiponectin and cardiac function. Methods : Twenty-two KD patients (22 patients in acute phase and 20 patients in subacute phase) were enrolled in the study group. The control group consisted of 31 subjects (13 febrile patients and 18 healthy children). Both groups underwent blood sampling and tissue Doppler imaging (TDI). Results : CRP was significantly increased in the KD group compared with the control group. There were no significant differences in serum $TNF-{\alpha}$, IL-6, and adiponectin levels between groups. However, a negative correlation was found between adiponectin level and CRP level or platelet count. Systolic myocardial velocity and A myocardial velocity measured by TDI were decreased significantly in the acute KD group compared with the subacute KD group and control group. Positive correlations were found between adiponectin level and systolic myocardial velocity or A myocardial velocity. Conclusion : In acute KD patients, low adiponectin level was related to severe inflammatory reactions and decreased left ventricular functions.

MR Technology to 4T

  • Vaughan, Thomas
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.103-105
    • /
    • 2003
  • After fifteen years of development, Magnetic Resonance (MR) technology for human imaging and spectroscopy is reaching a refined state with FDA approved 3T clinical products from Siemens, GE, and Philips. Broker has cleared CE approval with a 4T system. Varian supports a 4T system platform as well. Shielded magnets are standard at 3T from GE, Oxford, Magnex, and IGC. A shielded 4T whole body magnet is available from Oxford. Stronger switched gradients and dynamic shim coils, desired at any field, areespecially useful at higher static magnetic fields B0. In addition to the higher currents required for higher resolution slice or volume selection afforded by higher SNR, whole body gradient coils will be driven at increasing slew rates to meet the needs of new cardiac applications and other requirements. For example 3T and 4T systems are now being equipped with 2kV, 500A gradient coils and amplifiers capable of generating 4G/cm in 200msec, over a 67+/-cm bore diameter. High field EPI applications require oscillation rates at 1 kHz and higher. To achieve a benchmark 0.2 ppm shim over a 30cm sphere in a high field magnet, at least four stages of shimming need to be considered. 1) A good high field magnet will be built to a homogeneity spec. falling in the range of 100 to 150 ppm over this 30cm spherical "sweet spot" 2) Most modern high field magnets will also have superconducting shim coils capable of finding 1.5 ppm by their adjustment during system installation. 3) Passive ferro-magnetic shimming combined with 4) active, high order room temperature shim coils (as many as five orders are now being recommended) will accomplish 0.2 ppm over the 30cm sphere, and 0.1 ppm over a human brain in even the highest field magnets for human studies. Safety concerns for strong, fast gradients at any B0 field include acoustic noise and peripheral nerve stimulation. One or more of the mechanical decoupling methods may lead to quieter gradients. Patient positioning relative to asymmetric or short gradient coils may limit peripheral nerve stimulation at higher slew rates. Gradient designs combining a short coil for local speed and strength with a longer coil for coverage are being developed for 3T systems. Local gradients give another approach to maximizing performance over a limited region while keeping within the physiologically imposed dB0/dt performance limits.

  • PDF

Quantitative Assessment of Myocardial Infarction by In-111 Antimyosin Antibody (In-111-Antimyosin 항체를 이용한 심근경색의 정량적 평가)

  • Lee, Myung-Chul;Lee, Kyung-Han;Choi, Yoon-Ho;Chung, June-Key;Park, Young-Bae;Koh, Chang-Soon;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.37-45
    • /
    • 1991
  • Infarct size is a major determinant of prognosis after acute myocardial infarction. Up to date, however, clinically available tests to estimate this size have not been sufficiently accurate. Twelve lead electrocardiogram and wall motion abnormality measurement are not quantitative, and creatine phophokinase (CPK) measurement is inaccurate in the presence of reperfusion or right ventricular infarction. Methods have been developed to localize and size acute myocardial infarcts with agents that are selectively sequestered in areas of myocardial damage, but previously used agents have lacked sufficient specificity. Antibodies that bind specifically only to damaged myocardial cells may resolve this problem and provide an accurate method for noninvasively measuring infarct size. We determined the accuracy with which infarcted myocardial mass can be measured using single photon emission computed tomography (SPECT) and radiolabeled antimyosin antibodies. Seven patients with acute myocardial infarction and one stable angina patient were injected with 2 mCi of Indium-111 labeled antimyosin antibodies. Planar image and SPECT was performed 24 hours later. None of the patients had history of prior infarcts, and none had undergone reperfusion techniques prior to the study, which was done within 4 days of the attack. Planar image showed all infarct patients to have postive uptakes in the cardiac region. The location of this uptake correlated to the infarct site as indicated by electrocardiography in most of the cases. The angina patient, however, showed no such abnormal uptake. Infarct size was determined from transverse slices of the SPECT image using a 45% threshold value obtained from a phantom study. Measured infarct size ranged from 40 to 192 gr. There was significant correlation between the infarct size measured by SPECT and that estimated from serial measurements of CPK (r=0.73, p<0.05). These date suggest that acute myocardial infarct size can be accurately measured from SPECT Indium-111 antimyosin imaging. This method may be especially valuable in situations where other methods are unreliable, such as early reperfusion technique, right ventricular infarct or presence of prior infarcts.

  • PDF

Comparison of Diagnostic Accuracy for Detecting Coronary Artery Disease of Dipyridamole $^{99m}Tc$-MIBI Myocardial SPECT and It's Defect Map between Men and Women (디피리다몰 부하 $^{99m}Tc$-MIBI 심근 SPECT 극성결손지도를 이용한 관동맥질환 진단의 남녀 비교)

  • Bae, Sang-Kyun;Lee, Dong-Soo;Oh, Byung-Hee;Chung, June-Key;Lee, Myoung-Mook;Park, Young-Bae;Lee, Myung-Chul;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.59-64
    • /
    • 1993
  • To evaluate the usefulness and differences in diagnosing coronary artery disease (CAD) between men and women of intravenous dipyridamole $^{99m}Tc$-MIBI myocardial SPECT, we obtained $^{99m}Tc$-MIBI myocardial SPECT and compared with the findings of coronary angiographies. Ninety eight male and 37 female patients who underwent dipyridamole $^{99m}Tc$-MIBI myocardial imaging within one month of cardiac catheterization were studied. Scans were considered abnormal if perfusion defect was detected and the defect size was more than 12% for left anterior descending artery (LAD) and circumflex (LCX) and 8% for right coronary artery (RCA) territories. Lesions${\geqq}$50% luminal diameter narrowing were considered significant CAD. Overall sensitivity for detection of CAD was 94.3% in men and 96.4% in women; specificity was 70% in men and 52.6% in women (P=not significant, ns). Vessel-matched sensitivity was 75.3% in men and 72.7% in women (P=ns): specificity was 84.6% in men and 67.9% in women (P < 0.025). For individual coronary artery, the sensitivity in men and women was 87.7%, 81.8% for LAD; 78%, 83.3% for RCA and 52.2%, 46.7% for LCX (P=ns): the specificity was 80%, 40% for LAD (P<0.01), 82.5%, 68.4% for RCA, 88.9%, 86.4% for LCX (P=ns). The hemodynamic parameter after intravenous dipyridamole in men and women were significantly changed; the heart rate was increased and systolic, diastolic blood pressure was decreased. Adverse effects were reported in 58.8% of men and 72.7% in women (P=ns). The incidence of chest pain and headache were higher in women. There was no significant difference in the incidences of nausea, abdominal pain, dizziness, facial flushing, dyspnea. In conclusion, dipyridamole $^{99m}Tc$-MIBI myocardial SPECT is a safe, noninvasive test for evaluation of CAD. There was no gender difference to detect CAD, but more false-positive rate in women especially in the territory of LAD.

  • PDF