Aortic Valve Papillary Fibroelastoma Triggering Chest Pain -A case report- (흉통을 유발한 대동맥판막의 유두상 섬유탄력종 -1예 보고-)

  • Yeo, In-Gwon;Jung, Yo-Chun;Cho, Kwang-Ree;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.39 no.11 s.268
    • /
    • pp.858-860
    • /
    • 2006
  • Papillary fibroelastoma is the second most common benign cardiac tumor, usually involving the cardiac valve. Papillary fibroelastoma attached at the right coronary cusp of the aortic valve was found in a 51-year-old woman, who was presented with chest pain and dyspnea. During the operation, the tumor mass was excised without causing damage on the aortic valve leaflet.

Hemodynamic Evaluation of St. Jude Medical Prosthesis (센 쥬드 판막의 혈류 역학적 고찰)

  • 문광덕
    • Journal of Chest Surgery
    • /
    • v.28 no.12
    • /
    • pp.1122-1131
    • /
    • 1995
  • One hundred eighty-eight patients[August.23,1988,through July.30,1994 underwent aortic[AVR , mitral[MVR , or double [DVR valve replacement with the St.Jude Medical prosthesis. The author analyzed 100 patients with valvular heart disease,who underwent valve replacement with the St.Jude Medical prothesis from 1990 to 1994, at Hanyang University hospital Cardiovascular department. Information on volume and functional change of the heart chamber can be obtained by cardiac echocardiography and cartheterization. Out of 100 patients, 40 patients were male[40% and 60 patients were female [60% . Age ranged from 13 years to 68 years, with mean age of 42.6 years. Mean height was 160.3cm and mean body weight was 54.9Kg. According to NYHA functional classification, class III is most frequent and 60 patients could be classfied under it. MVR [involved Redo MVR was performed in 40 patients, AVR [involved Redo AVR was performed in 18 patients, and DVR [involved Redo DVR was performed in 42 patients. Warfarin [Coumadin anticoagulation was recommended for all patients. Life long warfarin anticoagulation was necessary to all patients who underwent valve replacement with St.Jude Medical prosthesis. Ideal prothrombin time was maintained about 30% during warfarinization. There were no case of mechanical failure. It followed a comparison of echocardiography before and after valve replacement at Hanyang University hospital [30 patients and a preoperative evaluation of cardiac catheterization and angiography [64 patients . The St.Jude Medical cardiac valve is a viable alternative in the surgical therapy of valvular heart disease.

  • PDF

Minimally Invasive Procedure versus Conventional Redo Sternotomy for Mitral Valve Surgery in Patients with Previous Cardiac Surgery: A Systematic Review and Meta-Analysis

  • Muhammad Ali Tariq;Minhail Khalid Malik;Qazi Shurjeel Uddin;Zahabia Altaf;Mariam Zafar
    • Journal of Chest Surgery
    • /
    • v.56 no.6
    • /
    • pp.374-386
    • /
    • 2023
  • Background: The heightened morbidity and mortality associated with repeat cardiac surgery are well documented. Redo median sternotomy (MS) and minimally invasive valve surgery are options for patients with prior cardiac surgery who require mitral valve surgery (MVS). We conducted a systematic review and meta-analysis comparing the outcomes of redo MS and minimally invasive MVS (MIMVS) in this population. Methods: We searched PubMed, EMBASE, and Scopus for studies comparing outcomes of redo MS and MIMVS for MVS. To calculate risk ratios (RRs) for binary outcomes and weighted mean differences (MDs) for continuous data, we employed a random-effects model. Results: We included 12 retrospective observational studies, comprising 4157 participants (675 for MIMVS; 3482 for redo MS). Reductions in mortality (RR, 0.54; 95% confidence interval [CI], 0.37-0.80), length of hospital stay (MD, -4.23; 95% CI, -5.77 to -2.68), length of intensive care unit (ICU) stay (MD, -2.02; 95% CI, -3.17 to -0.88), and new-onset acute kidney injury (AKI) risk (odds ratio, 0.34; 95% CI, 0.19 to 0.61) were statistically significant and favored MIMVS (p<0.05). No significant differences were observed in aortic cross-clamp time, cardiopulmonary bypass time, or risk of perioperative stroke, new-onset atrial fibrillation, surgical site infection, or reoperation for bleeding (p>0.05). Conclusion: The current literature, which primarily consists of retrospective comparisons, underscores certain benefits of MIMVS over redo MS. These include decreased mortality, shorter hospital and ICU stays, and reduced AKI risk. Given the lack of high-quality evidence, prospective randomized control trials with adequate power are necessary to investigate long-term outcomes.

One Stage Correction of the Pectus Excavatum with Marfan Syndrome (Marfan증후군의 수술 교정 1례)

  • Lee, Seung-Yeol;Nam, Yeong-Su;Kim, Hyeong-Muk
    • Journal of Chest Surgery
    • /
    • v.28 no.1
    • /
    • pp.65-68
    • /
    • 1995
  • Pectus excavatum occasionally occurs in patients who have underlying cardiac disease, especially Marfan syndrome. This report describes a patient with pectus excavatum who had ascending aortic aneurysm with aortic regurgitation and anterior leaflet prolapse of mitral valve. This patient underwent replacement of aortic valve and ascending aorta with 25 mm SJM valved conduit graft[Bentall operation with Cabrol shunt , and mitral valve replacement with SJM 31 mm, the pectus excavatum was corrected at the time of completion of the intracardiac operation with the modified sternal turnover. This procedure offered excellent operative exposure for the inracardiac operation with prevention of low cardiac output after operation due to depressed sternum and maintained chest wall stability resulting good cosmetic chest wall appearance. This patient recovered and discharged in good postoperative result with minimal temporary peroneal nerve palsy in his left leg.

  • PDF

Clinical Results of the Mechanical Cardiac Valves (기계판막의 임상적 평가)

  • 박창권
    • Journal of Chest Surgery
    • /
    • v.24 no.2
    • /
    • pp.161-170
    • /
    • 1991
  • Clinical results with the Mechanical cardiac valves were reviewed for 261 patients who underwent cardiac valve replacement from September, 1985 to July, 1990. of the Mechanical valves used, 156 were Carbomedics, 109 Duromedics, 52 St. Jude and 11 Bjork-Shiley. Overall hospital mortality was 14 out of 261[5,36%]: 9 out of 159[5.66%] for MVR, 1 out of 35[2.86%] for AVR and 4 out of 67[5.96%] for DVR[AVR+MVR]. Two hundred and forty seven operative survivors were followed up for a total 466.8 patient-years, ranged from 1 month to 4.9 years [a mean 1.8 years] and the follow up was 96.0%. There were 12 valve-related complications: three from thromboembolism, three from valve thrombosis, three from prosthetic valve endocarditis, two from paravalvular leak and the other one from hemorrhage. Actuarial rate free from all valve-related complication at 4.9 years was 96$\pm$1.3%. There were 11 late deaths: two from thromboembolism, one from valve thrombosis, one from prosthetic valve endocarditis, one from hemorrhage and the others 6 from non-valve-related complications. Actuarial survival rate at 4.9 years was 94$\pm$2.0%. 96$\pm$3.0% for MVR, 94$\pm$4.2% for AVR and 91$\pm$3.7% for DVR[AVR+MVR]. And there are 7 reoperations: three from paraprosthetic leak, two from prosthetic valve endocarditis and two from valve thrombosis. Actuarial rate free from reoperation at 9 years was 96$\pm$2.9%. On the basis of this 4.9 years of experience, the pyrolytic carbon mechanical valves appears to be an excellent mechanical prosthesis for cardiac valve replacement, in terms of hemodynamic performance, low mortality and low thrombogenecity.

  • PDF

Aortic Valve Replacement Using Continuous Suture Technique in Patients with Aortic Valve Disease

  • Choi, Jong Bum;Kim, Jong Hun;Park, Hyun Kyu;Kim, Kyung Hwa;Kim, Min Ho;Kuh, Ja Hong;Jo, Jung Ku
    • Journal of Chest Surgery
    • /
    • v.46 no.4
    • /
    • pp.249-255
    • /
    • 2013
  • Background: The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Materials and Methods: Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. Results: There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. Conclusion: The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.

Effects of Autotransfusion using Cell Saver in Cardiac Surgery (개심술시 자가 수혈체계[Cell Saver]의 이용 효과)

  • 안욱수
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1312-1317
    • /
    • 1992
  • Autologous blood transfusion is a common method of reducing the need for homologous blood transfusion during cardiac operations. Between June 1991 and May 1992, 12 cases [Group I] were experienced autologous blood transfusion using Cell Saver undergoing double valve replacement or redo-valve replacement. Control group [N=12, Group II] was selected to above similar operation during same period. The Cell Saver system [Haemonetics Corp.] was employed for autologous blood transfusion. The blood shed in the operative field before and after cardiopulmonary bypass and remained cardiotomy reservior was aspirated by means of a locally heparinized collecting system. After centrifused salvaged blood, the resulting red cell concentrate reinfused subsequently. The patient receiving autologous blood transfusion required significantly less homologous blood transfusion than their control group. [Group I; 3519 $\pm$ 869, Group II; 4622 $\pm$ 856, Respectively; P=0.005] There were no clinical infections in the autotransfusion group. And there was no apparent intergroup difference of the clinical findings, hematologio datas and coagulation parameters. We conclude the autotransfusion using Cell Saver is effective for reducing of the hom-ologlous blood transfusion in cardiac surgery.

  • PDF

Annual Open Heart Surgery: Report of 416 Cases in 1980 (연간 개심술 416례 보고 [1980 년도])

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.14 no.1
    • /
    • pp.17-25
    • /
    • 1981
  • In 1980, 416 cases of open heart surgery were done in this Department with over all operative mortality of 12.3%. 1. There were 288 congenital anomalies consisting of 174 acyanotic and 114 cyanotic varieties, which showed operative mortality of 6.9% and 25.4% respectively. 2. There were 128 cases of acquired lesions, 124 valvular disease and 3 myxoma being the main lesions. 3. There were 128 cases of valve replacement with operative mortality of 7.8%. 4. The most frequently operated anomaly was VSD, 90 pure VSD and 21 cases were associated with one or 2 cardiac anomalies. Over all operative mortality in 111 VSD cases was 8.1% but in 90 pure VSD cases it was 6.7%. 5. Tetralogy of Fallot showed the highest incidence in cyanotic group with 88 cases, consisting of 68 pure and 20 with other cardiac anomalies. Over all mortality in 88 cases was 19.3% but in pure form 16.2%. 6. In 128 valve replacement cases over all mortality was 9.4%. There were 85 mitral, 11 aortic, 2 tricuspid, 21 mitral with aortic, 6 mitral with tricuspid, 3 mitral, aortic, and tricuspid valve replacement cases. For mitral valve replacement operative mortality was 5.9%. 7. Twenty-one cases of babies under 10kg body weight were operated on with over all operative mortality of 28.6%. Sixteen cases of VSD were found with operative mortality of 25%. 8. Among 128 cases of valve replacement 7 were under the age of 15 years and 12 were between 15 and 20 years old. Five pediatric cases underwent mitral valve replacement without mortality, 9 year old boy was the youngest among them. In this Department open heart surgery for infancy and complex anomalies showed still hip operative risk which should be improved in the coming years. For open heart surgery Shiley oxygenators and 2 sets of A-O de-lux 5 head roller pump were utilized exclusively. For valve replacement Ionescu-Shiley bovine pericardial xenografts were mainly used. In pediatric and rural patients Persantin with aspirin regimen was satisfactorily administered for anticoagulation after valve replacement. Routinely Coumadin was administered for one year after valve replacement* In patients who had thrombus on valve sites, chronic atrial fibrillation, and giant left atrium Persantin-Aspirin regimen was used when one year coumadin administration was discontinued.

  • PDF

Long Term Clinical Results of Duromedics Valve (Duromedics 판막의 장기 임상 성적 고찰)

  • Jeong, Dong-Seop;Lim, Chung;Kim, Kyung-Hwan;Kim, Ki-Bong;Aun, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.686-691
    • /
    • 2001
  • Background: The Duromedics valve has been used in Korea since 1982, however, but there were no long term clinical results that have been reported. This paper presents the long term clinical results of Duromedics valve implanted in Seoul National University Hospital. Material and method: Between 1987, 23 patients underwnet cardiac valve replacement with Duromedics mechanical valve. There were 8 mitral valve replacements, 5 aortic valve replacements, one tricuspid valve replacement, 6 aortic and mitral valve replacements, and one mitral and tricuspid valve replacement. There were 12 men and 11 women. The mean age was 35$\pm$10(15~52) years. We evaluated the clinical performance of Duromedics cardiac prosthesis. Result: The early operative mortality was 4.3%(1/23) and the late morlatity was 4.3%(1/23). Causes of death were low cardiac output syndrome and structural valvular failure. The mean follow-up duration was 133$\pm$43(8~157) months. There were 3 reoperations. The causes of reoperations were thrombosis and structural failure and nonstructural valvular failure. The actuarial survival rate at 10 years was 90.9%. Conclusion: Although the number of patients was not sufficient for effective clinical study, the long term clinical results of Duromedics valve was relatively good and there was no structural defect in this mechanical valve. However, more research is needed in the future.

  • PDF

Left Atrial Myxoma (좌심방 점액종 1례 보고)

  • 오세웅
    • Journal of Chest Surgery
    • /
    • v.20 no.4
    • /
    • pp.809-814
    • /
    • 1987
  • Myxoma is a benign growth constituting nearly 50% of all primary cardiac tumors. It is important because in can be abolished by surgical therapy and is usually fatal if unrecognized and untreated. Primary cardiac tumors are uncommon in all age group. In contrast, tumors metastatic to the heart are significantly more common. The diagnosis is made by echocardiography and cardiac angiography. Recently a wider use of echocardiogram as the screening test of valve lesions can be expected to increase the number of myxomas found preoperatively. We report the two cases of left atrial myxomas which were removed successfully by surgery in the thoracic and cardiovascular surgery department, Marryknoll Hospital.

  • PDF