• Title/Summary/Keyword: Cardiac Valve Surgery

Search Result 476, Processing Time 0.017 seconds

Mid-term Follow-Up Results of Cryopreserved Valved Conduit in RVOT Reconstruction (우심실 유출로에 사용된 냉동 동종 판막도관의 중기성적)

  • 장윤희;전태국;민호기;한일용;성기익;이영탁;박계현;박표원
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.384-390
    • /
    • 2003
  • Background: Since Ross and Sormeville first reported the use of aortic homograft valve for correction of pulmonary atresia in 1966, homograft valves are widely used in the repair of congenital anomalies as conduits between the pulmonary ventricle and pulmonary arteries. On the basis of these results, we have used it actively. In this report, we describe our experience with the use of cryopreserved valved homograft conduits for infants and children requiring right ventricle to pulmonary artery connection in various congenital cardiac anomalies. Material and Method: Between January, 1996 and December 2001, 27 infants or children with a median age of 16 months(range 9days to 18years) underwent repair of RVOTO using homograft valved conduit by two surgeons. We studied 22 patients who have been followed up at least more than one year. The diagnosis at operation included pulmonary atresia with ventricular septal defect (n=13), truncus arteriosus (n=3), TGA or corrected TGA with RVOTO (n=6). Homograft valved conduits varied in size from 15 to 26 mm (mean, 183.82 mm). The follow-up period ranged from 12 to 80.4 months (median, 48.4 months). Result: There was no re-operation due to graft failure itself. However, early progressive pulmonary homograft valve insufficiency developed in one patient, that was caused by dilatation secondary to the presence of residual distal pulmonary artery stenosis and hypoplasia after repair of pulmonary atresia with ventricular septal defect. This patient was required reoperation (conduit replacement). During follow-up period, there were significant pulmonary stenosis in one, and pulmonary regurgitation more than moderate degree in 3. And there were mild calcifications at distal anastomotic site in 2 patients. All the calcified homografts were aortic in origin. Conclusion: We observed that cryopreserved homograft conduits used in infant and children functioned satisfactorily in the pulmonic position at mid-term follow-up. To enhance the homograft function, ongoing investigation is required to re-establish the optimal strategy for the harvest, preservation and the use of it.

An Animal Study on Electrohydraulic Type Ventricular Assist Device (전기 유압식 심실보조장치의 동물실험 연구)

  • 백완기;심상석
    • Journal of Chest Surgery
    • /
    • v.29 no.7
    • /
    • pp.689-699
    • /
    • 1996
  • An animal experiment was designed for the evaluation of in vivo performance of the newly developed electrohydraulic type ventricular assist device and its influence on the left ventricular function during pal- satile left ventricular assist. Eight adult sheep were incorporated into the study and data were collected from seven sheep. Total as- sist time ranged from 69 minutes to 7 days. The performance of the device was satisfactory both in asyn- chr nous and synchronous mode within the range of given native heart rate. More than 4 liters of device output could be reached within the range of normal left atral pressure without development of negative pressure in the left atrium. Moderate to severe degree of hemolysis was noted as evidenced by significant increase of plasma free hemoglobin level after 3 days of left ventricular support along with the presence of the small amount of thrombi around the floating disc type polymer valve apparatus reflecting that further study and refinement of the device need to be done in regard of biocompatibility and thromboresistance. The hemodynamics showed increase in heart rate (p < 0.05), cardiac output and left ventricular minute work (p < 0.05) after placement of the device at the flow rate of 2.0∼2.5 Llmin. The left atrial pressure, left ventricular pressure and LV dpldt were decreased after the device placement(p < 0.05). The endocardial viability ratio and oxygen contents of the mixed ven us blood and coronary venous blood were all increased (p < 0.05) after the device placement suggesting effective unloading of the left ventricle was accomplished. The myocardial perfusion was thought improved in synchronous counterpulsation as suggested by sig- nificant increase in endocardial viability ratio and coronary venous blood oxygen content in synchronous assist mode comparing with asynchronous mode.

  • PDF

Coronary Artery Bypass Surgery with Radial Artery -Early Results (요골동맥을 이용한 관상동맥우회술 -조기성적)

  • 나찬영;이영탁;박국양;이해영;김욱성;박?현;홍민수;심재천;권오춘
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.275-281
    • /
    • 1997
  • The radial artery as a graft for myocardial revascularization was introduced by Carpentier in the early 1970s. Mid-term results were unfortunately discoura ing, and the clinical experience with this graft was interrupted. At the end of the 1980s, these authors reproposed the same arterial conduit with more satisfying results, because of improved technique and pharmacological management of the graft. Between October 1994 and July 1995, 36 patients underwent myocardial revascularization with a radial artery graft in Seiong General Hospital. Left internal mammary artery was concomitantly used as a pedicled Vift in 34 patients. Fifteen patients (42%) had a complete arterial waft revascularization. A total of 12) distal anastomoses were performed (average 3.4 per patient), including 36 left internal mammary artery wafts (two sequential in 2 patients), and 23 saphenous vein grafts. The remaining 64 distal anastomoses were perFormed with radial artery grafts (mean 1.8 per patient). The radial arteries were anastomosed to the circumflex (n=38), diagonal (n= 18), right coronary(n=G), and left anterior descending coronary artery(n=2). The percent ge of radial artery graft anastomoses (64) to the total anastomoses(123) was 52%. The radial artery was used as a single graft in 10 patients, as a sequential graft in 25 patients, and two grafts in 1 patient. Twenty patients underwent associated procedures coronary endarterectomy (14), coronary artery patch angioplasty (4), mitral valve repair (1), and repair of ventricular septal rupture (1). One patient died of low cardiac output syndrome and the others had no perioperative myocardial infarction. There are no ischemic and functional complications in the arm or hand aftcr removal of the radial artery. Only 1 patient required reexploration of the am, for the hematoma evacuation, and 2 patients complained transient thumb dysesthesia of the side of the havested arm. This dysesthesia improved within one month. Postoperative angiovaphic controls were obtained in 11 patients(31%) postoperative 79 to 210 days (mean 126 days). The patency rate were as follows : left internal mammary artery (100%), saphcnous vein (100%), and radial artery(95%). We concluded that the radial artery is useful alternative graft, but long term clinical and angiographic studies are required to derterminc whether wider application is warranted.

  • PDF

Clinical features and surgical results of ruptured sinus of valsalva aneurysm (발살바동 동맥류 파열의 임상적 고찰)

  • Lee, Tae Ho;Lee, Dong Won;Cho, Joon Yong;Hyun, Myung Chul;Lee, Sang Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.3
    • /
    • pp.287-291
    • /
    • 2006
  • Purpose : Aneurysms of sinus valsalva are rare anormalies thought to be primarily congenital in origin, progressing into death by acute heart failure in cases of rupture. Surgical correction is the only method of treatment. With these clinical implications, we reviewed the clinical characteristics and surgical results of patients with ruptured sinus of valsalva aneurysm. Methods : Between January 1991 and February 2004, 17 patients with ruptured sinus of valsalva aneurysm were retrospectively reviewed for their clinical symptoms, physical findings, past history, coexistent cardiac anormalies, surgical results, and mid-term prognosis. Results : The 17 patients included 13 men and four women, with a mean age of 30 years(10-59 years). Preoperatively accompanying cardiac anormalies were ventricular septal defect(VSD, eight cases of doubly committed juxta-arterial VSD) and aortic insufficiency(11 cases). During operations, patterns of fistulous tracts were found to be right colonary sinus-right ventricle in 13 patients, right coronary sinus-right atrium in one, noncoronary sinus - right ventricle in two, noncoronary sinus - right atrium in one, and VSD was noticed in 14 patients(all were doubly committed juxta-arterial in type). The defects were closed with a patch in 13 patients, without a patch in four, with concommitant aortic valve replacement in four and with aortic valvuloplasty in two. There were no mortalities during operations or the mid-term follow-up periods($40{\pm}49$ months). Conclusion : Because, at least in Orientals, VSD(especially doubly committed juxta-arterial) was accompanied in large numbers of patients with aneurysms of sinus valsalva, preoperative evaluations of this congenital heart disease should be made very careful. And we may need to revise the algorithm of treatment policy in small sized doubly committed juxta-arterial VSD.

Mid-Term Results of 292 cases of Coronary Artery Bypass Grafting (관상동맥 우회술 292례의 중기 성적)

  • 김태윤;김응중;이원용;지현근;신윤철;김건일
    • Journal of Chest Surgery
    • /
    • v.35 no.9
    • /
    • pp.643-652
    • /
    • 2002
  • As the prevalence of coronay artery disease is increasing, the surgical treatment has been universalized and operative outcome has been improved. We analyzed the short and mid-term results of 292 CABGs performed in Kangdong Sacred Heart Hospital. Material and Method: From June 1994 to December 2001, 292 patients underwent coronary artery bypass grafting. There were 173 men and 119 women and their ages ranged from 39 to 84 years with a mean of $61.8{\pm}9.1$ years. We analyzed the preoperative risk factors, operative procedures and operative outcome. In addition, we analyzed the recurrence of symptoms, long-term mortality and complications via out-patient follow-up for discharged patients. Result: Preoperative clinical diagnoses were unstable angina in 137(46.9%), stable angina in 34(11.6%), acute myocardial infarction in 40(13.7%), non-Q myocardial infarction in 25(8.6%), postinfarction angina in 22(7.5%), cardiogenic shock in 30(10.3%) and PTCA failure in 4(1.4%) patients. Preoperative angiographic diagnoses were three-vessel disease in 157(53.8%), two-vessel disease in 35 (12.0%), one-vessel disease in 11(3.8%) and left main disease in 89(30.5%) patients. We used saphenous veins in 630, internal thoracic arteries in 257, radial arteries in 50, and right gastoepiploic arteries in 2 distal anastomoses. The mean number of distal anastomoses per patient was $3.2{\pm}1.0$ There were 18 concomitant procedures ; valve replacement in 8(2.7%), left main coronary artery angioplasty in 6(2.1%), patch closure of postinfarction ventricular septal defect(PMI-VSD) in 2(0.7%), replacement of ascending aorta in 1(0.3%) and coronary endarterectomy in 1(0.3%) patient. The mean ACC time was $96.6{\pm}35.3 $ minutes and the mean CPB time was $179.2{\pm}94.6$ minutes. Total early mortality was 8.6%, but it was 3.1% in elective operations. The most common cause of early mortality was low cardiac output syndrome in 6(2.1%) patients. The stastistically significant risk factors for early mortality were hypertension, old age($\geq$ 70 years), poor LV function(EF<40%), congestive heart failure, preoperative intraaortic balloon pump, emergency operation and chronic renal failure. The most common complication was arrhythmia in 52(17.8%) patients. The mean follow-up period was $39.0{\pm}27.0$ months. Most patients were free of symptoms during follow-up. Fourteen patients(5.8 %) had recurrent symptoms and 7 patients(2.9%) died during follow-up period. Follow-up coronary angiography was performed in 13 patients with recurrent symptoms and they were managed by surgical and medical treatment according to the coronary angiographic result. Conclusion: The operative and late results of CABG in our hospital, was acceptable. However, There should be more refinement in operative technique and postoperative management to improve the results.

Changes in Immunogenicity of Preserved Aortic Allograft (보존된 동종동맥편 조직의 면역성 변화에 관한 연구)

  • 전예지;박영훈;강영선;최희숙;임창영
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1173-1181
    • /
    • 1996
  • The causes of degenerative changes in allograft cardiac valves are not well known to this day. Today's preserved allografts possess highly viable endothelial cells and degeneration of allografts can be facilitated by immune reaction which may be mediated by these viable cells. To test the antigenicity of endothelial cells, pieces from aortic wall were obtained from fresh and cryo-preserved rat allograft. Timings of sampling were prior to sterilization, after sterilization, after 1, 2, 7, 14 days of fresh preservation and cryopreservation. Endothelial cells were tested by immunohistochemical methods using monoclonal antibodies to MHC class I(MRC OX-18), class II(MRC OX-6) and ICAM-1 antigens. After transplantation of each group of aortic allograft at the subcutaneous layers of rats, population of CD4$^{+}$ T cell and CD8$^{+}$ T cell were analyzed with monoclonal antibodies after 1, 2, 3, 4, 6 and 8 weeks. MHC class I expression was 23.95% before preservation and increased to 35.53~48.08% after preservation(p=0.0183). MHC Class II expression was 9.72% before preservation and 10.13~13.39% after preservation(P=0.1599). ICAM-1 expression was 15.02% before preservation and increased to 19.85~35.33% after preservation(P=0.001). The proportion of CD4$^{+}$ T-cell was 42.13% before transplantation. And this was 49.23~36.8% after transplantation in No treat group (p=0.955), decreased to 29.56~32.80% in other group(p=0.0001~0.008). In all the groups, the proportion of CD8$^{+}$ T-cell increased from 25.57% before transplantation to 42.32~58.92% after transplantation(p=0.000l~0.0002). The CD4$^{+}$/CD8$^{+}$ ratio decreased from 1.22~2.28 at first week to 0.47~0.95 at eighth week(p=0.0001). The results revealed that the expression of MHC class I and ICAM-1 in aortic allograft endothelium were increased but that of MHC class II were not changed, despite the different method of preservation. During 8 weeks after transplantation of aortic allograft, the subpopulations of CD4$^{+}$ T cell were not changed or only slightly decreased but those of CD8$^{+}$ T cell were progressively increased.ely increased.

  • PDF