• Title/Summary/Keyword: Carbon steel S45C

Search Result 64, Processing Time 0.027 seconds

A Study on the Heat Transfer of the High Temperature Metals in Quenching 1st Reprot; Subcooled Transient Boiling Heat Transfer and Colling Curves (고온 강재의 담금질 열전달에 관한 연구 제1보 : 과냉과도 비등열전달과 냉각곡선)

  • 윤석훈;홍영표;김경근;김용모
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1529-1540
    • /
    • 1993
  • The quenching of steels by water is one of the imprtant problems in the applications of heat treatment, but the fundamental researches by way of theoretical approaches have not been satisfactorily improbed yet. This study aimed at measuring the exact subcooled transient boiling curve for cylindrical specimens and at conducting the analytical researches into the prediction of cooling curves, including the latent heat of phase transformation of steel. Experiments of quenching were made with cylindrical specimens of carbon steel S45C of diameters from 12 to 30 mm and with Cu specimens of 12 mm diameter respectively. The internal temperature of specimens during the quenching process was measured by C-A sheathed thermocouple. The heat fluxes were numerically calculated by the numerical method of inverse heat conduction problem, using the measured inner temperature of specimen as a boundary condition. In case of ${\Delta}T_{sub}=80K$, $q_{s}$ is as follows $q_{s}=2.02{\times}10^{5}{\Delta}T_{set}^{0.05}:{\Delta}T_{set}\le500K.$ And the numerical analysis of unsteady heat conduction during the quenching process was made and the cooling curves were calculated by TDMA method.

Plasma nitriding on chromium electrodeposit

  • Wang Liang;K.S. Nam;Kim, D.;Kim, M.;S.C. Kwon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.29-30
    • /
    • 2001
  • This paper presents some results of plasma nitriding on hard chromium deposit. The substrates were C45 steel and $30~50{\;}\mu\textrm{m}$ of chromium deposit by electroplating was formed. Plasma nitriding was carried out in a plasma nitriding system with $95NH_3{\;}+{\;}SCH_4$ atmosphere at the pressure about 600 Pa and different temperature from $450^{\circ}C{\;}to{\;}720^{\circ}C$ for various time. Optical microscopy and X-ray diffraction were used to evaluate the characteristics of surface nitride layer formed by nitrogen diffusion from plasma atmosphere inward iCr coating and interface carbide layer formed by carbon diffusion from substrate outward Cr coating. The microhardness was measured using microhareness tester at the load of 100 gf. Corrosion resistance was evaluated using the potentiodynamic measurement in 3.5% NaG solution. A saturated calomel electrode (SiCE) was used as the reference electrode. Fig.1 shows the typical microstructures of top surface and cross-section for nitrided and unnitrided samples. Aaer plasma nitriding a sandwich structure was formed consisting of surface nitride layer, center chromium layer and interface carbide layer. The thickness of nitride and carbide layers was increased with the increase of processing temperature and time. Hardness reached about 1000Hv after nitriding while 900Hv for unnitrided hard chromium deposit. X-ray diffraction indicated that surface nitrided layer was a mixture of $Cr_2N$ and CrN at low temperature and erN at high temperature (Fig.2). Anodic polarization curves showed that plasma nitriding can greatly improve the corrosion resistance of chromium e1ectrodeposit. After plasma nitriding, the corrosion potential moved to noble direction and passive current density was lower by 1 to 4 orders of magnitude compared with chromium deposit(Fig.3).

  • PDF

Strengthening of Cutouts in Existing One-Way Spanning R. C. Flat Slabs Using CFRP Sheets

  • Shehab, Hamdy K.;Eisa, Ahmed S.;El-Awady, Kareem A.
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.2
    • /
    • pp.327-341
    • /
    • 2017
  • Openings in slabs are usually required for many different applications such as aeriation ducts and air conditioning. Opening in concrete slabs due to cutouts significantly decrease the member stiffness. There are different techniques to strengthen slabs with opening cutouts. This study presents experimental and numerical investigations on the use of Carbon Fiber Reinforced Polymers (CFRP) as strengthening material to strengthen and restore the load carrying capacity of R.C. slabs after having cutout in the hogging moment region. The experimental program consisted of testing five (oneway spanning R.C. flat slabs) with overhang. All slabs were prismatic, rectangular in cross-section and nominally 2000 mm long, 1000 mm width, and 100 mm thickness with a clear span (distance between supports) of 1200 mm and the overhang length is 700 mm. All slabs were loaded up to 30 kN (45% of ultimate load for reference slab, before yielding of the longitudinal reinforcement), then the load was kept constant during cutting concrete and steel bars (producing cut out). After that operation, slabs were loaded till failure. An analytical study using finite element analysis (FEA) is performed using the commercial software ANSYS. The FEA has been validated and calibrated using the experimental results. The FE model was found to be in a good agreement with the experimental results. The investigated key parameters were slab aspect ratio for the opening ratios of [1:1, 2:1], CFRP layers and the laminates widths, positions for cutouts and the CFRP configurations around cutouts.

Heat Transfer Characteristics of Bulkhead Penetration Piece for A60 Class Compartment II: Fire Resistance Test for Piece Material and Insulation Types (A60급 구획 적용 격벽 관통용 관의 열전달 특성 II: 관 재질 및 단열재 종류에 따른 방화시험)

  • Park, Woo-Chang;Song, Chang Yong
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.340-349
    • /
    • 2019
  • In the case of a fire accident on a ship or an offshore plant, the design of the bulkhead penetration piece must be verified via a fire test procedure (FTP), as specified by the Maritime Safety Committee (MSC). The purpose of this study is to verify both the numerical analysis results and the design specifications for penetration pieces that could be applied to the A60 class bulkhead division. In this study, the FTP was carried out in accordance with the test procedure prescribed in the MSC regulation. In order to review the fire resistance performance according to the material type, bulkhead penetration pieces for the FTP were made from brass, carbon steel for machine structures (S45C), and austenite stainless steel (SUS316). In addition, spray-type insulation and mechanical fastener-type insulation were applied to investigate the fire resistance performance according to the type of insulation. To verify the heat transfer numerical analysis results for the A60 class bulkhead penetrating piece from this test study, the design specifications of the penetrating piece material and the insulation type applicable to a ship and an offshore plant were identified.