• Title/Summary/Keyword: Carbon ion beam

Search Result 140, Processing Time 0.043 seconds

Review of the Existing Relative Biological Effectiveness Models for Carbon Ion Beam Therapy

  • Kim, Yejin;Kim, Jinsung;Cho, Seungryong
    • Progress in Medical Physics
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • Hadron therapy, such as carbon and helium ions, is increasingly coming to the fore for the treatment of cancers. Such hadron therapy has several advantages over conventional radiotherapy using photons and electrons physically and clinically. These advantages are due to the different physical and biological characteristics of heavy ions including high linear energy transfer and Bragg peak, which lead to the reduced exit dose, lower normal tissue complication probability and the increased relative biological effectiveness (RBE). Despite the promising prospects on the carbon ion radiation therapy, it is in dispute with which bio-mathematical models to calculate the carbon ion RBE. The two most widely used models are local effect model and microdosimetric kinetic model, which are actively utilized in Europe and Japan respectively. Such selection on the RBE model is a crucial issue in that the dose prescription for planning differs according to the models. In this study, we aim to (i) introduce the concept of RBE, (ii) clarify the determinants of RBE, and (iii) compare the existing RBE models for carbon ion therapy.

Electro-Optical Characteristics of the Ion-Beam-Aligned FFS-LCD on a Diamond-like-Carbon Thin Film

  • Hwang, J.Y.;Park, C.J.;Seo, D.S.;Jeong, Y.H.;Kim, K.C.;Ahn, H.J.;Baik, H.K.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1132-1136
    • /
    • 2004
  • In this paper, we intend to make FFS mode cell with LC alignment used non-rubbing method, ion beam alignment method on the a-C:H thin film, to analyze electro-optical characteristics in this cell. We studied on the suitable inorganic thin film for FFS-LCD and the aligning capabilities of nematic liquid crystal (NLC) using the new alignment material of a-C:H thin film as working gas at rf bias condition. A high pretilt angle of about 5$^{\circ}$ by ion beam(IB) exposure on the a-C:H thin film surface was measured. An excellent voltage-transmittance (V-T) and response time curve of the ion-beam-aligned FFS-LCD was observed with oblique ion beam exposure on the DLC thin films.

  • PDF

Non-contact mode measurement of high aspect ratio tip (High aspect ratio 팁의 비접촉모드에서의 측정)

  • Shin Y.H.;Han C.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.463-464
    • /
    • 2006
  • This paper present experimental results by non-contact mode Atomic Force Microscopy using high aspect ratio tips (HAR-T). We fabricated the carbon nanotube tip based on dielectrophoresis and the carbon nano probe by focused ion beam after dielectrophoretic assembling. In this paper, we measure AAO sample and trench structure to estimate HAR-T's performance and compared with conventional Si tip. We confirmed that results of HAR-T's performance in non contact mode was very superior than conventional tip.

  • PDF

Measurement of Neutron Production Double-differential Cross-sections on Carbon Bombarded with 430 MeV/Nucleon Carbon Ions

  • Itashiki, Yutaro;Imahayashi, Youichi;Shigyo, Nobuhiro;Uozumi, Yusuke;Satoh, Daiki;Kajimoto, Tsuyoshi;Sanami, Toshiya;Koba, Yusuke;Matsufuji, Naruhiro
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.344-349
    • /
    • 2016
  • Background: Carbon ion therapy has achieved satisfactory results. However, patients have a risk to get a secondary cancer. In order to estimate the risk, it is essential to understand particle transportation and nuclear reactions in the patient's body. The particle transport Monte Carlo simulation code is a useful tool to understand them. Since the code validation for heavy ion incident reactions is not enough, the experimental data of the elementary reaction processes are needed. Materials and Methods: We measured neutron production double-differential cross-sections (DDXs) on a carbon bombarded with 430 MeV/nucleon carbon beam at PH2 beam line of HIMAC facility in NIRS. Neutrons produced in the target were measured with NE213 liquid organic scintillators located at six angles of 15, 30, 45, 60, 75, and $90^{\circ}$. Results and Discussion: Neutron production double-differential cross-sections for carbon bombarded with 430 MeV/nucleon carbon ions were measured by the time-of-flight method with NE213 liquid organic scintillators at six angles of 15, 30, 45, 60, 75, and $90^{\circ}$. The cross sections were obtained from 1 MeV to several hundred MeV. The experimental data were compared with calculated results obtained by Monte Carlo simulation codes PHITS, Geant4, and FLUKA. Conclusion: PHITS was able to reproduce neutron production for elementary processes of carbon-carbon reaction precisely the best of three codes.

탄소 음이온 빔에 의해 증착된 DLC 필름의 특성 평가

  • 김인교;김용환;이덕연;최동준;한동원;백홍구
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.59-59
    • /
    • 1999
  • DLC(diamond-like carbon)필름은 다이아몬드와 유사한 강도, 낮은 마차계수, 높은 Optical band gap, NEA(negative electron affinity)등의 우수한 특성을 가지고 있어, 내마모 코팅이나 정보저장 매체의 윤활 코팅, FED(field emission display)의 전계방출소자등 다양한 분야에의 응용이 연구되고 있다. DLC 필름은 PECVD(plasma enhanced chemical vapor deposition), IBAD(ion beam assisted deposition), Laser ablation, Cathodic vacuum arc등의 process를 이용하여 증착되고 있다. 특히 이러한 필름의 물성은 입사되는 이온의 에너지에 의해 좌우되는데, Lifshitz 등의 연구에 의하여 hyperthermal species를 이용한 DLC 필름의 성장은 초기에 subsurface로의 shallow implantation이 일어난 후 높은 sp3 fraction을 갖는 필름이 연속적으로 성장한다는 subplantation model이 제시 되었다. 본 연구에서는 기판과 subplantation 영역이 이후 계속하여 증착되는 순수 DLC 필름의 특성 변호에 미치는 영향에 대하여 관심을 가지고 실험을 행하였다. 본 실험에서는 상기 제시되어 있는 방법보다도 더욱 정확하고도 독립적으로 탄소 음이온의 에너지와 flux를 조절할 수 있는 Cs+ ion beam sputtering system을 이용하여 탄소 음이온의 에너지를 40eV에서 200eV까지 변화시키며 필름을 증착하였다. Si(100) 웨이퍼를 기판으로 사용하였고 증착 압력은 5$\times$10-7torr 였으며 인위적인 기판의 가열은 하지 않았다. 또한 Ion beam deposited DLC film의 growth process를 연구하기 위하여 200eV의 탄소 음이온을 시간(증착두께)을 변수로 하여 증착하였고, 이 때에는 Kaufman type의 gas ion beam을 이용하여 500eV의 Ar+ ion으로 pre-sputering을 행하였다. 탄소 음이온의 에너지와 증착두께에 따라 증착된 film 내의 sp3/sp2 ratio 의 변화를 XPS plasmon loss 와 Raman spectra를 이용하여 분석하였다. 또한 증착두께에 따른 interlayer의 결합상태를 관찰하기 위하여 AES와 XPS 분석을 보조로 행하였다.

  • PDF

Development and Applications of TOF-MEIS (Time-of-Flight - Medium Energy Ion Scattering Spectrometry)

  • Yu, K.S.;Kim, Wansup;Park, Kyungsu;Min, Won Ja;Moon, DaeWon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.107.1-107.1
    • /
    • 2014
  • We have developed and commercialize a time-of-flight - medium energy ion scattering spectrometry (TOF-MEIS) system (model MEIS-K120). MEIS-K120 adapted a large solid acceptance angle detector that results in high collection efficiency, minimized ion beam damage while maintaining a similar energy resolution. In addition, TOF analyzer regards neutrals same to ions which removes the ion neutralization problems in absolute quantitative analysis. A TOF-MEIS system achieves $7{\times}10^{-3}$ energy resolution by utilizing a pulsed ion beam with a pulse width 350 ps and a TOF delay-line-detector with a time resolution of about 85 ps. TOF-MEIS spectra were obtained using 100 keV $He^+$ ions with an ion beam diameter of $10{\mu}m$ with ion dose $1{\times}10^{16}$ in ordinary experimental condition. Among TOF-MEIS applications, we report the quantitative compositional profiling of 3~5 nm CdSe/ZnS QDs, As depth profile and substitutional As ratio of As implanted/annealed Si, Ionic Critical Dimension (CD) for FinFET, Direct Recoil (DR) analysis of hydrogen in diamond like carbon (DLC) and InxGayZnzOn on glass substrate.

  • PDF

The preparation of ultra hard nitrogenated DLC film by $N_2^+$ implantation

  • Olofinjana, A.O.;Chen, Z.;Bell, J.M.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.165-166
    • /
    • 2002
  • Hydrogen free diamond like carbon (DLC) films were prepared on steel substrates by using a single ion beam in a configuration that allowed sputtering of a graphite target and at the same time allowed to impact the substrate at a grazing angle. The DLC films so prepared have improved properties with increased disorder and with modest hardness that is slightly higher than previously reported values. We have studied the effects of $N_2^+$ ions implantation on such films. It is found that the implantations of nitrogen ions into DLC films lead to chemical modifications that allowed N atoms to be incorporated into the carbon network to produce a nitrogenated DLC. Nano-indentation experiments indicated that the nitrogenated films have consistently higher hardnesses ranging from 30 to 45GPa, which represents a considerable increase in surface hardness, compared with non-nitrogenated precursor films. The investigations by XPS and Raman spectroscopy suggests that the $N_2^+$ implanted DLCs had undergone both chemical and structural modifications through the incorporation of N atoms and the increased ratio of $sp^3/sp^2$ type bonding. The observed high hardness was therefore attributable to these structural and chemical modifications. This result has implication for the preparation of super hard wear resistant films required for tribological functions in devices.

  • PDF

Carbon-ion radiotherapy in osteosarcoma of the mandible: a case report

  • Ha, Tae-Wook;Park, Slmaro;Youn, Min Yeong;Kim, Dong Wook;Kim, Hyung Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.4
    • /
    • pp.315-320
    • /
    • 2021
  • Carbon-ion radiotherapy (CIRT) is on the rise as a treatment choice for malignant tumor. Compared to conventional radiotherapy, particle beams have different physical and biological properties. Particle beam provides a low entry dose, deposits most of the energy at the endpoint of the flight path, and forms an asymptotic dose peak (the "Bragg peak"). Compared to protons, carbon with its larger mass decreases beam scattering, resulting in a sharper dose distribution border. We report a 50-year-old male who underwent CIRT without surgical resection on osteosarcoma of the mandible. After CIRT, the patient's pain was gone, and the malignant mass remained stable with accompanying necrosis. Nine months later, however, magnetic resonance imaging demonstrated progression of the left mandibular osteosarcoma with pulmonary metastases. After multidisciplinary discussion, concurrent chemoradiotherapy was conducted. While necrotic bone segments came out of the mandible during subsequent periodic outpatient visits, the tumor itself was stable. Thirty months after his first visit and diagnosis, the patient is waiting for chemotherapy. Although CIRT is superior in treating radioresistant hypoxic disease, CIRT is in its infancy, so care must be taken for its indications and complications.

Liquid Crystal Alignment Effects Using a Carbon Nitride Thin Film (Carbon Nitride 박막을 이용한 액정배향 효과)

  • Park, Chang-Joon;Hwang, Jeong-Yeon;Kang, Hyung-Ku;Seo, Dae-Shik;Ahn, Han-Jin;Kim, Kyung-Chan;Kim, Jong-Bok;Baik, Hong-Koo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.23-26
    • /
    • 2004
  • We studied the nematic liquid crystal (NLC) aligning capabilities using the new alignment material of a Carbon Nitride (NDLC) thin film. NDLC thin film exhibits high electrical resistivity and thermal conductivity that are similar to the properties shown by diamond-like carbon (DLC) thin films. The diamond-like properties and nondiamond-like bonding make NDLC an attractive candidate for applications. A high pretilt angle of about $9.9^{\circ}$ by ion beam (IB) exposure on the NDLC thin film surface was measured. A good LC alignment is achieved by the IB alignment method on the NDLC thin film surface at annealing temperature of $200^{\circ}C$. The alignment defect of the NLC was observed above annealing temperature of $250^{\circ}C$. Consequently, the high pretilt angle and the good LC alignment by the IB alignment method on the NDLC thin film surface can be achieved.

  • PDF