• Title/Summary/Keyword: Carbon dioxide (CO2)

Search Result 1,976, Processing Time 0.038 seconds

Development of Gas Treatment System for Passenger Cabins (객차용 가스처리장치 개발)

  • Lee, Ju-Yeol;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1302-1306
    • /
    • 2007
  • Malfunction or inappropriate management of ventilation system in public transportation may cause unpleasant atmosphere or health problems to the old or feeble passengers. In this work, adsorption/desorption system for gaseous carbon dioxide is developed and tested under the various indoor conditions. Finally an optimum design specification for the indoor $CO_2$ control will presented.

  • PDF

Thermodynamic Properties of Caffeine in Compressed Gas

  • Kim, Jeong Rim;Gyeong, Jin Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.5
    • /
    • pp.432-436
    • /
    • 1995
  • The solubility of caffeine in compressed carbon dioxide has been measured to determine its fugacity coefficient between 330 and 410 K up to 500 bar. The result allows the calculation of the thermodynamic excess functions such as the molar excess enthalpy, the molar excess free energy, and the molar excess entropy. The pressure variations of the molar excess functions of caffeine in the caffeine-CO2 mixture were discussed and also compared them with those in the caffeine-NH3 mixture.

New Analytical Method Using Polar Modifiers in Supercritical Fluid Chromatography and Its Application to the Separation of Fatty Alcohol Ethers

  • 표동진;이규선;이학주;김호현;Milton L. Lee
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.6
    • /
    • pp.496-498
    • /
    • 1996
  • Fatty alcohol ethers, nonionic surfactants which are used as general purpose emulsifiers were separated by use of water-modified carbon dioxide mobile phase in capillary supercritical fluid chromatography. Much greater peak intensities and improved separation were observed in the chromatogram with on-line modified mobile phase than with pure CO2. A simple method for the preparation of on-line modified mobile phase is also introduced.

Effect of Supercritical Carbon Dioxide on Physicochemical Properties and Microbial Reduction of Freeze-Dried Bovine Liver (초임계 이산화탄소 처리가 동결 건조된 소간의 이화학적 특성 및 미생물 저감화에 미치는 영향)

  • Kim, Hye-Min;Woo, Sung-Woon;Kim, Ah-Na;Heo, Ho-Jin;Chun, Ji-Yeon;Choi, Sung-Gil
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.12
    • /
    • pp.1847-1855
    • /
    • 2015
  • Supercritical carbon dioxide ($SC-CO_2$) treatment has been becoming an important method for substituting the use of organic solvents for samples extraction prior to analysis due to its low toxicity, ease of handling, low cost of disposal etc. Freeze-dried bovine liver was treated with $SC-CO_2$ under different pressures (200, 300, and 450 bar) in order to investigate effects on physicochemical properties and reduction of microbial load. The yield of lipid extraction from bovine liver by $SC-CO_2$ treatment increased with increasing pressure, with values of 84, 86, and 90% in response to 200, 300, and 450 bar, respectively. Results of high performance liquid chromatography analysis showed that vitamin A and coenzyme $Q_{10}$ ($CoQ_{10}$), which is soluble in lipid, were almost removed from bovine liver by $SC-CO_2$ treatment. Saturated fatty acids ratio of bovine liver decreased with increasing pressure, whereas polyunsaturated fatty acids increased with increasing pressure. Total content of amino acids in bovine liver treated by $SC-CO_2$ was less than that of the control sample without treatment. The number of aerobic bacteria in bovine liver, which was stored at $5^{\circ}C$ for 5 days and freeze-dried, decreased from 6.2 to 4.2 log CFU/g by $SC-CO_2$ treatment at 100 bar for 3 h. Interestingly, coliform bacteria were not found in the bovine liver sample by $SC-CO_2$ at 100 bar for 3 h under all storage conditions. This indicates that $SC-CO_2$ treatment can effectively reduce coliform bacteria in the food matrix even at low moisture. In conclusion, freeze-dried bovine liver by proper $SC-CO_2$ treatment may be used as a potential high protein source, with increasing microbial safety and stability of lipid oxidation.

Electrocatalytic Reduction of CO2 by Copper (II) Cyclam Derivatives

  • Kang, Sung-Jin;Dale, Ajit;Sarkar, Swarbhanu;Yoo, Jeongsoo;Lee, Hochun
    • Journal of Electrochemical Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.106-110
    • /
    • 2015
  • This study investigates Cu(II) complexes of cyclam, propylene cross-bridged cyclam (PCB-cyclam), and propylene cross-bridged cyclam diacetate (PCB-TE2A) as homogeneous electrocatalysts for CO2 reduction in comparison with Ni(II)-cyclam. It is found that Cu(II)-cyclam can catalyze CO2 reduction at the potential close to its thermodynamic value (0.75 V vs. Ag/AgCl) in tris-HCl buffer (pH 8.45) on a glassy carbon electrode. Cu(II)-cyclam, however, suffers from severe demetalation due to the insufficient stability of Cu(I)-cyclam. Cu(II)-PCB-cyclam and Cu(II)-PCB-TE2A are revealed to exhibit much less demetalation behavior, but poor CO2 reduction activities as well. The inferior electrocatalytic ability of Cu(II)-PCB-cyclam is ascribed to its redox potential that is too high for CO2 reduction, and that of Cu(II)-PCB-TE2A to the steric hindrance preventing facile contact with CO2 molecules. This study suggests that in addition to the redox potential and chemical stability, the stereochemical aspect has to be considered in designing efficient electrocatalysts for CO2 reduction.

Experimental Studies of the Blood Gas Transport during Normothermic Hemodilution Perfusion (상온하 혈액희석 체외순환에 있어서 혈액 GAS 동태에 관한 실험적 연구)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.85-91
    • /
    • 1980
  • Extracorporeal circulation by hemodilution technique has been currently used with its clinical safety and good peripheral tissue perfusion in open heart surgery. There is no doubt that $O_{2}$ carrying capacity of the blood is disturbed by decreased hemoglobin level resulting from hemodilution of the circulating blood. From the view point of the blood gas exchange, these experimental studies were undertaken to determined the sate limit of hemodilution in the condition of cardiopulmonary bypass with a constant perfusion flow rate. Twelve adult mongrel dogs weighing 10 to 13 Kg. were anesthetized with pentobarbital and then respiration was controlled with Harvard volume respirator using room air. The cardiopulmonary by pass was performed by use of Sarns heart lung machine (console 5000, 5 head and 2 roller pumps) and Travenol pediatric bubble oxygenator. The perfusion rate during bypass was maintained at a constant rate of 80 ml/min/Kg of body weight. The ratio of oxygen gas flow to blood flow was kept in 3 to 1 constantly. International hemodilution was attained by serial blood withdrawals and immediate infusion of equal volumes of diluants composed of Ringer's lactate, 5% dextrose in water and 25% mannitol solution, proportionally 60%, 30%, and 10%. Arterial and venous blood samples were obtained between 15 and 20 minutes following each hemodilution. Hematocrits and hemoglobin values, $PO_{2}$, $PCO_{2}$ and pH were measured. Oxygen and carbon dioxide contents oxygen consumption and carbon dioxide elimination were calculated groups according to different hematocrit values and the correlations were evaluated. Result were as follows. 1. the arterial $O_{2}$ tension and $O_{2}$ saturation were maintained at the physiological level irrespective of the hematocrit value. 2. The venous $O_{2}$ tension and $O_{2}$ saturation showed a tendency to decline with the decrease in hematocrit value and positive correlation between them (r = +0.49, r = +0.76), The mean values of venous $O_{2}$ tension and $O_{2}$ saturation, however, were not decreased when the hematocrit levels were lower than 20%. 3. The arterial $O_{2}$ content declined lineally in proportion to the fall of hematocrit level with a positive correlation between them (r = +0.95). 4. The venous $O_{2}$ contents were decreased gradually as the hematocrit value decreased with positive correlation between them ( r =+0.89). The trend of diminution of venous $O_{2}$ content, however, was became low according to progressive decrease of hematocrit level. 5. Systemic oxygen consumption was in higher range than $O_{2}$ requirement of basal metabolism when the hematocrit value was above 20%, but abruptly decreased when the hematocrit value became to below 20%. 6. The arterial $CO_{2}$ tension and $CO_{2}$ content showed trend of increasing with progressive decrease of hematocrit value but exhibited a rather broad range and there was no relationship between those value and the hematocrit value. 7. The venous $CO_{2}$ tension and $CO_{2}$ content have also no correlation with change of Ht. value but related directly to those value of arterial blood with positive correlation between them (r = +0.78, r = +0.95_. 8. A-V difference of $CO_{2}$ content and $CO_{2}$ elimination wasnot significantly influenced by Ht. value. From the results, we obtained that feasible limit in inteneional hemodilution is above the hematocrit value of 20% under the given experimental condition.

  • PDF