• 제목/요약/키워드: Capillary performance

검색결과 233건 처리시간 0.027초

Experimental Study of Thermal Performance of Heat Pipe with Axial Trapezoidal Grooves (축방향 사다리꼴 그루브 히트파이프의 열성능에 대한 실험적 연구)

  • Suh, Jeong-Se;Lee, Woon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제27권4호
    • /
    • pp.407-414
    • /
    • 2003
  • Analysis and experiment are performed to investigate the thermal performance of a heat pipe with axial grooves. The heat pipe was designed in a 6.5 mm I.D., 17 axial trapezoidal grooves. 1000 mm long tube of aluminium, and ammonia as working fluid. A mathematical equations fur heat pipe with axial grooves is formulated to obtain the capillary limitation on heat transport rate in a steady state. As a result, heat transport factor of heat pipe has the maximum at the operating temperature of 293K in 0m elevation. As the elevation of heat pipe increases. the heat transport factor of the heat pipe is reduced markedly, comparing with that of horizontal elevation of the heat pipe. It may be considered that such behavior of heat pipe is caused by the working fluid swarmed back to the condenser port due to gravity force and supercooled by a coolant of heat exchanger. Analytical results of heat transport factor are in a good agreement with those of experiment.

Effects of the Mass of Working Fluid on the Thermal Performance of Heat Pipe with Axial Grooves (그루브형 히트파이프에서 작동유체량이 히트파이프 성능에 미치는 영향)

  • Suh, Jeong-Se;Park, Young-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2003
  • An analytical and experimental study of the thermal performance of axial heat pipe with axial groove is conducted to determine the optimal mass of working fluid for the maximum heat transport capacity of heat pipe with axial grooves. Generally, the mass of working fluid has been fully charged by considering only a geometrical shape of axial grooves embedded in a heat pipe. When the heat pipe is operated in a steady state, the meniscus re-cession phenomena of working fluid is occurred in the evaporator region. In this work, the optimal mass of working fluid was obtained from the axial variation of capillary pressure, the radius of curvature and wetting angle of meniscus of liquid-vapor interface. Experimental results were also obtained by varying the mass of working fluid within a heat pipe, and presented for the maximum heat transport capacity corresponding to the operating temperature and the elevation of heat pipe. Finally, the analytical results of the optimal mass of working fluid were compared with those of the experimental mass of working fluid.

Parameter identification for the bubble point measurement of Liquid Acquisition Device (액체포집장치의 기포점 측정을 위한 변수식별)

  • Jeon, Sang-Eon;Park, Soo-Hyung;Byun, Yung-Hwan;Jung, Young-Suk;Oh, Seung-Hyub
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.416-423
    • /
    • 2012
  • Liquid acquisition device in the liquid propellant supply system is required to protect entrance of gas bubble into the propulsion system. The device exploits the capillary effect of micro-sized poles in a screen and supplies pure liquid-phase propellant to the propulsion system. The bubble point is the most important performance parameter in the design of a liquid acquisition device. In this paper, performance parameters affecting the bubble point are identified through literature survey, in order to develop the experimental setup for the bubble point measurement.

  • PDF

A Study on the Manufacturing Technology for the Development of Heat Pipes with a Sintered Metal Wick (소결 금속 윅 히트파이프 개발을 위한 제조 기술 연구)

  • Choi, Jee-Hoon;Kim, Sung-Dae;Sung, Byung-Ho;Roo, Seong-Ryou;Park, Hyung-Ki;Kim, Chul-Ju;Ko, Han-Seo
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.479-482
    • /
    • 2006
  • The most the electronic industry has recently accelerated the modularization, the miniaturization and the high integrated trend of electronics fields such as electronics components, appliances and etc., the most increasingly the heat generation problem rises. Even though the conventional cooling technologies are widely used in order to reduce the heat loads, the technologies are not easy to meet the present trends due to the fact that most of many conventional methods are relative to external form environments such as size, design and so on. With regardless of those environments, however, a heat pipe is one of the most efficient systems to improve the heat transfer performance. And then the performance of the heat pipe depends on a wick structure. Of various wick structures, sintered metal wick is known so that it has some advantages such as smaller pore size, increasing porosity as well as high reliability. In this study sintered metal wicks, thickness 0.7 mm, 0.8 mm and 0.9 mm, were manufactured as of $100{\mu}m$ copper powder to obtain the manufacturing technology of heat pipes mounted with a sintered metal wick. Furthermore, experiments for the operational performance factors such as capillary limit, thermal resistance were not only performed but also compared with a theoretical model simultaneously. Experimental results agreed with the theoretical model, and then it seems to be required to study various development processes of sintered metal wicks for the high performance of a heat pipe system.

  • PDF

Effects of Capillary Water Interruption Layer on the Growth of Zoysiagrasses and Cool-season Turfgrasses in Reclaimed Land (염해지에서 모세관수 차단층 설치 유무에 따른 한국잔디 및 한지형 잔디류의 생육)

  • Kim, Jun-Beom;Yang, Geun-Mo;Choi, Joon-Soo
    • Asian Journal of Turfgrass Science
    • /
    • 제23권1호
    • /
    • pp.35-44
    • /
    • 2009
  • This study was carried out to examine the growth performance of 4 species of cool-season grasses and 4 species of zoysiagrasses under salt injury in Seo-san reclaimed area. Grasses were grown on the plots with capillary water interruption layer (WCWIL) and without capillary water interruption layer (WOCWIL) soil systems. Cool-season grass and seeding-type zoysiagrass plots were seeded on 6 Jun, 2006. Vegetative zoysiagrass 'Junggi' was established by sprigging and 'Senock' and 'Millock' were plugged. Electric conductivities of irrigation water (ECw) ranged from 0.28 to $3.3\;dS{\cdot}m^{-1}$. Electric conductivities (ECe) of the soil with capillary water interruption layer and without capillary water interruption layer ranged from 0.55 to $9.4\;dS{\cdot}m^{-1}$ and from 1.84 to $9.4\;dS{\cdot}m^{-1}$ respectively. Leaf color, turf quality, coverage rates, and growth rates were rated visually for 2 years. Zoysiagrass 'Junggi', creeping bentgrass, zoysiagrass 'Senock' and 'Millock' showed acceptable growth at salty fairway condition, while Kentucky bluegrass, perennial ryegrass, Kentucky bluegrass mixed with perennial ryegrass, and seeded zoysiagrass 'Zenith' showed establishment rates below 70%. These results will be useful when choosing turf grass species and cultivars for the golf courses in reclaimed land area.

Performance Analysis of the Soft Ice-cream Maker Having Two Evaporators Operating at Different Temperatures (두개의 증발기가 장착된 소프트 아이스크림 제조기의 성능 해석)

  • Kim, Jeong-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제14권2호
    • /
    • pp.517-522
    • /
    • 2013
  • Small size ice-cream maker has two evaporators having different evaporating temperatures of $4^{\circ}C$ and $-8^{\circ}C$. In such case, ice-cream maker system design becomes complicated because multiple capillary tubes affects one another. In this study, performance analysis was conducted for the soft ice-cream maker having two evaporators operating at different temperatures. The compressor was analyzed using efficiency models, the capillary tube was modeled assuming one-dimensional flow, the condenser and the evaporators were modeld based on UA-LMTD method. The refrigeration cycle simulation program was developed applying the enthalpy, pressure and mass balance on each component. Comparison of the test data with the simulated results for R404A revealed that evaporator temperatures of refrigerator and freezer agreed within $3^{\circ}C$.

Performance analysis of a cold-air forced circulation type showcase (냉기 강제순환형 공랭식 쇼케이스 성능 해석)

  • Kim, Jeong-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제14권3호
    • /
    • pp.1003-1010
    • /
    • 2013
  • In this study, a simulation program was developed, which predicts the performance of cold-air forced circulation type air cooled showcase. The showcase has an excellent display effect in addition to preserving the grocery. In the program, the compressor was analyzed using performance data supplied by the manufacturer and the capillary tube pressure drop was analyzed using a homogeneous model. The evaporator and condenser were analyzed by dividing the heat exchangers into small elements, where energy balance and appropriate heat transfer correlations were used. A showcase model with two 3/4 HP compressors, capillary tubes of 1.6 mm inner diameter, a fin-and-tube evaporator and condenser was tested, and the results are compared with the predicted values. It is shown that both evaporation and condensation temperatures are adequately predicted by the program.

Pulse wave Measurement System by analyzing a Moving Pulse Image in the Capillary Tube (모세관 맥동파 영상을 이용한 맥파 측정 시스템)

  • Lee, Woo-Beom;Choi, Chang-Yur;Hong, You-Sik;Lee, Sang-Suk;Nam, Dong-Hyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • 제12권2호
    • /
    • pp.145-151
    • /
    • 2012
  • The pulsimeter is a representative device in the oriental medicine, which can analysis a risk factor in a cardiovascular diseases. However, most of the previous methods have the limit by the contacted sate of the brachial pulse and sensor in the measuring time, the inaccuracy of detected pulse, and the difficulty of pulse analysis. Accordingly, we propose the moving pulse image analysis based pulsimeter that can acquire a pulse of patient in real time by analyzing a moving image. then this video is shot the state change of the T.S. occurred by a pulse in capillary. In order to evaluate the performance of the our pulsimeter, we measured a respective detecting-rate about the essential 5 feature-points in the pulse analysis from the detected original pulse. As a result, the proposed method is very successful.

Performance of self-compacting concrete made with coarse and fine recycled concrete aggregates and ground granulated blast-furnace slag

  • Djelloul, Omar Kouider;Menadi, Belkacem;Wardeh, George;Kenai, Said
    • Advances in concrete construction
    • /
    • 제6권2호
    • /
    • pp.103-121
    • /
    • 2018
  • This paper reports the effects of coarse and fine recycled concrete aggregates (RCA) on fresh and hardened properties of self-compacting concrete (SCC) containing ground granulated blast-furnace slag (GGBFS) as cement replacement. For this purpose, three SCC mixes groups, were produced at a constant water to binder ratio of 0.38. Both fine and coarse recycled aggregates were used as natural aggregates (NA) replacement at different substitution levels of 0%, 25%, 50%, 75% and 100% by volume for each mix group. Each group, included 0, 15% or 30% GGBFS as Portland cement replacement by weight. The SCC properties investigated were self-compactability parameters (i.e., slump flow, T500 time, V-funnel flow time, L-box passing ability and sieve stability), compressive strength, capillary water absorption and water penetration depth. The results show that the combined use of RCA with GGBFS had a significant effect on fresh and hardened SCC mixes. The addition of both fine and coarse recycled aggregates as a substitution up to 50% of natural aggregates enhance the workability of SCC mixes, whereas the addition from 50 to 100% decreases the workability, whatever the slag content used as cement replacement. An enhancement of workability of SCC mixes with recycled aggregates was noticed as increasing GGBFS from 0 to 30%. RCA content of 25% to 50% as NA replacement and cement replacement of 15% GGBFS seems to be the optimum level to produce satisfactory SCC without any bleeding or segregation. Furthermore, the addition of slag to recycled concrete aggregates of SCC mixes reduces strength losses at the long term (56 and 90 days). However, a decrease in the capillary water absorption and water permeability depth was noticed, when using RCA mixes with slag.

Theoretical Analysis of Heat Pipe Thermal Performance According to Nanofluid Properties (나노유체 특성에 따른 히트파이프 성능해석)

  • Lim, Seung Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제39권7호
    • /
    • pp.599-607
    • /
    • 2015
  • In this study, we theoretically investigate the thermal performances of heat pipes that have different nano-fluid properties. Two different types of nano-particles have been used: $Al_2O_3$ and CuO. The thermal performances of the heat pipes are observed for varying nano-particle aggregations and volume fractions. Both the viscosity and the conductivity increase as the volume fraction and the aggregation increase, respectively. Increasing the volume fraction helps increase the capillary limit in the well-dispersed condition. Whereas, the capillary limit is decreased under the aggregate condition, when the volume fraction increases. The dependence of the heat pipe thermal resistance on the volume fraction, aggregation, and conductivity of the nano-particles is analyzed. The maximum thermal transfer of the heat pipe is highly dependent on the volume fraction because of the high permeability of the heat pipe. For the proposed heat pipe, the optimum volume fraction of the nano-particle can be seen through 3D graphics.