• Title/Summary/Keyword: Capillary flow

검색결과 382건 처리시간 0.027초

대체냉매 R-407C의 모세관 선정에 관한 연구 (Investigation on the selection of capillary tube for the alternative refrigerant R-407C)

  • 김용환;김창년;박영무
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.56-65
    • /
    • 1998
  • In this paper, experimental investigation of capillary tube performance for R-407C is performed. The experimental setup is made of real vapor-compression refrigerating system. In this study, mass flow rate is measured for capillary tubes of various diameter and length as inlet pressure and degree of subcooling are changed. These data are compared with the results of a numerical model. The mass flow rates of the numerical model are less than by 14% compared with the measured mass flow rates. It is found that mass flow rate and length for R-407c are less than those of R-22 under the same condition. Also based on this experimental study and the numerical model, a set of capillary tube selection charts for R-407C is constructed.

  • PDF

Suitable Use of Capillary Number for Analysis of NAPL Removal from Porous Media

  • Jeong, Seung-Woo,
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.25-28
    • /
    • 2004
  • The capillary number is used to represent the mobilization potential of organic phase trapped within porous media. The capillary number has been defined by three different forms, according to types of flow velocity and viscosity used in the definition of capillary number. This study evaluated the suitability of the capillary number definitions for representing TCE mobilization by constructing capillary number-TCE saturation relationships. The results implied that the capillary number should be correctly employed, according to interest of scale and fluid flow behavior. This study suggests that the pore-scale capillary number may be used only for investigating the organic-phase mobilization at the pore scale because it is defined by the pore-velocity and the dynamic viscosity. The Newtonian-fluid capillary number using Darcy velocity and the dynamic viscosity may be suitable to quantify flood systems representing Newtonian fluid behavior. For viscous-force modified flood systems such as surfactant-foam floods, the apparent capillary number definition employing macroscopic properties (permeability and potential gradient) may be used to appropriately represent the desaturation of organic-phases from porous media.

  • PDF

$CO_2$ 단열 모세관내 유동 특성 (Flow Characteristics in an Adiabatic Capillary Tube of Carbon Dioxide)

  • 노건상;손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제19권6호
    • /
    • pp.537-544
    • /
    • 2008
  • In this paper, flow characteristics of an adiabatic capillary tube in a transcritical $CO_2$ have been investigated employing the homogeneous model. The model is based on fundamental equations of mass, energy and momentum which are solved simultaneously. Two friction factors(Churchill) and viscosity(McAdams) are comparatively used to investigate the flow characteristics. Supercritical and subcritical thermodynamic and transport properties of $CO_2$ are calculated employing EES property code. Flow characteristics analysis of $CO_2$ adiabatic capillary tube is presented to offer the basic design data for the operating parameters. The operating parameters considered in this study include inlet temperature and pressure of an adiabatic capillary tube, evaporating temperature and inner diameter tube. The main results were summarized as follows : inlet temperature and pressure of an adiabatic capillary tube, evaporating temperature, mass flowrate and inner diameter of $CO_2$ adiabatic capillary tube have an effect on length of an adiabatic capillary tube.

A Generalized Correlation and Rating Charts for Mass Flow Rate through Capillary Tubes with Several Alternative Refrigerants

  • Choi Jong Min;Jang Yong Hee;Kim Yongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.192-197
    • /
    • 2004
  • A capillary tube, which is a common expansion device in small sized refrig-eration and air-conditioning systems, should be redesigned properly to establish an optimum operation cycle of a refrigerating system with alternative refrigerants. Based on experimental data for R-22, R-290, and R-407C, an empirical correlation is developed to predict mass flow rate through capillary tubes. Dimensionless parameters are derived from the Buckingham Pi theorem, considering the effects of operating conditions and capillary tube geometry on mass flow rate. Approximately $97\%$ of the present data are correlated within a relative deviation of $\pm\;10\%.$ The present correlation also predicts the data obtained from open literature within $\pm\;15\%.$ In addition, rating charts of refrigerant flow rate for R-12, R-22, R-134a, R-152a, R-407C, R-410A, R-290, and R-600a are developed.

Identification of venular capillary remodelling: a possible link to the development of periodontitis?

  • Townsend, David
    • Journal of Periodontal and Implant Science
    • /
    • 제52권1호
    • /
    • pp.65-76
    • /
    • 2022
  • Purpose: The present study measured changes in arteriolar and venular capillary flow and structure in the gingival tissues during the development of plaque-induced gingival inflammation by combining dynamic optical coherence tomography (OCT), laser perfusion, and capillaroscopic video imaging. Methods: Gingival inflammation was induced in 21 healthy volunteers over a 3-week period. Gingival blood flow and capillary morphology were measured by dynamic OCT, laser perfusion imaging, and capillaroscopy, including a baseline assessment of capillary glycocalyx thickness. Venular capillary flow was estimated by analysis of the perfusion images and mean blood velocity/acceleration in the capillaroscopic images. Readings were recorded at baseline and weekly over the 3 weeks of plaque accumulation and 2 weeks after brushing was resumed. Results: Perfusion imaging demonstrated a significant reduction of gingival blood flow after 1 and 2 weeks of plaque accumulation (P<0.05), but by 3 weeks of plaque accumulation there was a more mixed picture, with reduced flow in some participants and increased flow in others. Participants with reduced flux at 3 weeks also demonstrated venular-type flow as determined by perfusion images and evidence of the development of venular capillaries as assessed by the velocity/acceleration ratio in capillaroscopic images. After brushing resumed, these venular capillaries were broken down and replaced by arteriolar capillaries. Conclusions: After 3 weeks of plaque accumulation, there was wide variation in microvascular reactions between the participants. Reduced capillary flow was associated with the development of venular capillaries in some individuals. This is noteworthy, as an early increase in venous capillaries is a key vascular feature of cardiovascular disease, psoriasis, Sjögren syndrome, and rheumatoid arthritis-diseases with a significant association with the development of severe gingival inflammation, which leads to periodontitis. Future investigations of microvascular changes in gingival inflammation might benefit from accurate capillary flow velocity measurements to assess the development of venular capillaries.

모세관과 오리피스 팽창장치의 냉매유량 조절특성의 비교 (Comparison of refrigerant flow through capillary with short tube orifice)

  • 김용찬;최종민
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.118-128
    • /
    • 1998
  • Capillary and short tube orifice have been widely used as an expansion device in refrigeration and air-conditioning system. To improve the system performance, expansion devices need to be optimized with the components of a refrigeration system. In the present study, a numerical model for a capillary, which can predict properties along a tube and flow rate through a tube, was developed by assuming homogeneous two-phase flow, A semi-empirical flow model that can be used to evaluate the flow rate through a short tube orifice was also developed by summarizing the experimental data. Finally, the results of the numerical model for capillaries were compared with those of the semi-empirical model for short tube orifices to verify dominant flow factors for the expansion devices.

  • PDF

그루브형 태양열 집열용 히트파이프의 열성능 해석 (Analysis for Thermal Performance of Axially Grooved Heat Pipe for Solar Collector)

  • 홍정규;서정세;변길성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2123-2128
    • /
    • 2004
  • In this study, analysis is made for the effects of groove shape on the thermal performance of a axial groove heat pipe. The mathematical models of two-phase flow in grooved heat pipe are presented for the capillary limitation in steady state. Generally, the heat pipe performance depends on the capillary pressure and liquid flow. The friction force of liquid flow through the groove increases with the groove width decreased, and then the capillary pressure is improved in the gas-liquid interface of groove. Therefore, the optimal groove width shaper exists for the maximum thermal performance of heat pipe. In this paper, the optimal groove shape and scale are presented by considering both capillary pressure and liquid flow.

  • PDF

단열 모세관내 R600a의 유동 특성 (Flow Characteristics of R600a in an Adiabatic Capillary Tube)

  • 구학근
    • 한국산학기술학회논문지
    • /
    • 제11권2호
    • /
    • pp.449-454
    • /
    • 2010
  • 본 논문은 균질유동모델을 적용하여 단열 모세관내 R600a의 유동 특성을 이론적으로 조사하였다. 이 모델은 시뮬레이션 해석에 필요한 기본적인 질량, 에너지, 운동량 방정식에 근거하고 있다. 또한 2개의 마찰인자와 점성계수모델을 이용하여 유동특성을 조사하였다. R600a의 열역학 및 전달 물성치는 EES 물성치 코드를 이용하여 계산하였다. 작동변수들에 대한 기초 설계자료를 제공하고자 단열 모세관내 R600a의 유동 특성을 분석하였다. 본 연구의 작동변수에는 응축온도, 증발온도, 과냉각도, 모세관의 직경이 있다. 주요 결과를 요약하면 다음과 같다. R600a용 단열 모세관내 응축온도, 증발온도, 과냉각도, 관직경은 모세관 전체길이에 영향을 준다. 즉 R600a용 모세관 전체길이는 식(15)와 같은 상관식으로 나타낸다.

대체냉매를 적용한 일반화된 모세관의 유량예측 상관식 (A Generalized Empirical Correlation on the Mass Flow Rate through Adiabatic Capillary Tubes with Alternative Refrigerants)

  • 최종민;장용희;김용찬
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.744-750
    • /
    • 2003
  • The performance of adiabatic capillary tubes are measured to provide the database for a generalized correlation. Test conditions and capillary tube geometries are selected to cover a wide range typically observed in air-conditioning and heat pump applications. Based on extensive experimental data for R22, R290, and R407C measured in this study, a generalized correlation for refrigerant flow rate in adiabatic capillary tubes is developed by implementing dimensionless parameters for tube inlet conditions, capillary tube geometry, and refrigerant properties. The correlation yields good agreement with the present data for R22, R290, and R407C with average and standard deviations of 0.9% and 5.0%, respectively. In addition, approximately 97% of the data for Rl2, R134a, R152a, R410A, and R600a obtained in the open literature are correlated within a relative deviation of $\pm$ 15%.

Investigation on the Selection of Capillary Tube for the Alternative Refrigerant R-407C

  • Kim, Chang-Nyeun;Park, Young-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권1호
    • /
    • pp.40-49
    • /
    • 2000
  • The capillary tube performance for R-407C is experimentally investigated. The experimental setup is a real vapor-compression refrigerating system. Mass flow rate is measured for various diameter and length while inlet pressure and degree of subcooling are changed. These data are compared with the results of a numerical model. The mass flow rate of the numerical model is about 14% less than the measured mass flow rate. It is found that mass flow rate and length for R-407C are less than those for R-22 under the same condition. Based on this experimental study and the numerical model, a set of design charts for capillary tube of R-407C is proposed.

  • PDF