• 제목/요약/키워드: Capillary dimension

검색결과 16건 처리시간 0.023초

Rabbit의 당수치에 따른 모세혈관 혈류의 카오스적 분석에 대한 연구 (A Study of the Chaotic Analysis of Flow of Capillary Blood Vessel by glucose index)

  • 최준영;조승열;김덕훈;임종덕;임재중;남상희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.258-262
    • /
    • 1996
  • The physiological systems have nonlinear complex phenomena. Expecially, the flow of capillary blood vessel has a nonlinear dynamic system. Thus, this study analyzes nonlinear characteristics of the flow of capillary blood vessel in physiological systems using chaotic tools(phase space reconstruction, correlation dimension, largest lyapunov exponent). Experimental data have been acquired from examining 10 rabbits. The results of chaotic analysis showed a decreasing largest lyapunov exponent and correlation dimension according to increasement glocose index. And we also know the chaotic behavior.

  • PDF

Dimension Analysis of Chaotic Time Series Using Self Generating Neuro Fuzzy Model

  • Katayama, Ryu;Kuwata, Kaihei;Kajitani, Yuji;Watanabe, Masahide;Nishida, Yukiteru
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1993년도 Fifth International Fuzzy Systems Association World Congress 93
    • /
    • pp.857-860
    • /
    • 1993
  • In this paper, we apply the self generating neuro fuzzy model (SGNFM) to the dimension analysis of the chaotic time series. Firstly, we formulate a nonlinear time series identification problem with nonlinear autoregressive (NARMAX) model. Secondly, we propose an identification algorithm using SGNFM. We apply this method to the estimation of embedding dimension for chaotic time series, since the embedding dimension plays an essential role for the identification and the prediction of chaotic time series. In this estimation method, identification problems with gradually increasing embedding dimension are solved, and the identified result is used for computing correlation coefficients between the predicted time series and the observed one. We apply this method to the dimension estimation of a chaotic pulsation in a finger's capillary vessels.

  • PDF

고로슬래그 미분말 혼입 시멘트 페이스트의 프랙탈 특성에 관한 기초적 분석 (Basic Analysis on Fractal Characteristics of Cement Paste Incorporating Ground Granulated Blast Furnace Slag)

  • 김지영;최영철;최성철
    • 콘크리트학회논문집
    • /
    • 제29권1호
    • /
    • pp.101-107
    • /
    • 2017
  • 본 연구는 시멘트계 재료의 프랙탈 특성에 관한 기초적 연구로써, 고로슬래그 미분말 혼입 시멘트 페이스트의 공극 구조를 수은압입법을 이용하여 측정하였고, 측정된 결과를 프랙탈 모델에 적용하여 그 특성을 분석하였다. 분석 결과, 고로슬래그미분말 혼입 시멘트 페이스트의 공극 구조는 그 범위가 나노미터부터 밀리미터 단위까지 다양하게 분포하는 불규칙한 조직이기 때문에, 전체 영역에 대한 프랙탈 차원을 산정했을 때 각 공극 영역의 특성을 반영할 수 없다. 따라서 프랙탈 차원 산정 시 공극 영역을 나누어서 분석하였다. Zhang and Li (1995) model을 적용했을 때, 시멘트와 GGBFS의 수화반응 결과 생성된 C-S-H 내의 gel pores 및 small capillary pores에 해당하는 micro 영역과 large capillary pores에 해당하는 macro 영역에서 각각 프랙탈 특성이 나타나는 결과를 보였다. 또한 macro 영역보다 micro 영역의 공극 표면이 더 불규칙한 형상을 나타내었다. Ji et al. (1997) model을 적용할 경우, micro 영역이 C-S-H 내의 gel pores에 해당하는 micro I과 small capillary pores에 해당하는 micro II로 구분되었으며, 각각의 프랙탈 특성이 산정되었다. 또한 Zhang and Li (1995) model을 결과와 유사하게, macro, micro II, micro I의 순서대로 공극 크기가 작아질수록 VFD 결과 값이 감소하였으며, 이는 곧 공극의 복잡성이 증가함을 나타낸다.

Pits Role in Embolism Repair of Populus tomentiglandulosa T. Lee

  • Chun, Su-Kyoung;Ahmed, Sheikh Ali
    • 한국가구학회지
    • /
    • 제18권2호
    • /
    • pp.147-151
    • /
    • 2007
  • This report explains the intervessel pit dimension of Populus tomentiglandulosa and its role in embolism repair according to proposed mechanism by Zwieniecki and Holbrook, 2000. It was found that mean contact angle ( ) of water droplets on the inner surface of vessels was $56^{\circ}$. Openings into the bordered pits were typically elliptical. The angle of the bordered pit chamber ($2{\alpha}$) was found $142.17^{\circ}$. From the capillary equation $Pmax\;=\;Gcos\;(\;+{\alpha})$, it was found that mathematically the maximum pressure 0.08MPa created by pits, can be employed to force the air within the embolized vessel into solution.

  • PDF

간헐포기 소화슬러지의 개량과 탈수 특성에 관한 비교 연구 (A Comparative Study on the Conditioning and Dewaterability of Digested Sludge from Intermittent Aerobic Digestion)

  • 김성홍;최영균;정태학
    • 한국물환경학회지
    • /
    • 제20권4호
    • /
    • pp.370-375
    • /
    • 2004
  • Synthetic organic polyelectrolytes can be used to condition sludges to enhance their dewaterability. When conditioning biological sludges, the charge on the polymer has a significant impact on the effectiveness of the polymer as a conditioner. The objectives of this investigation were to determine the most effective type and dosage of polymer for conditioning digested sludge prior to dewatering, and to investigate the relationship between dewaterability and particle size. 3 types of digested sludge were used under the different digestion processes like anaerobic digestion, aerobic digestion and intermittent aerobic digestion. CST(capillary suction time), TTF(time-to-filter) and SRF(specific resistance to filtration) were tested as a dewaterability index and the number of particle distribution was analyzed using particle size analyzer. The results indicate that cationic polymer appears to be required for effective conditioning of these 3 types digested sludge and the optimal polymer dosage is about 0.6% of SS. CST and TTF are well correlated with mean particle diameter of which the dimension order is 1.7.

稀薄溶液에서의 Polymer의 機械的 切斷 (제3보). 混合溶媒의 영향 (Mechanical Degradation of Polymers in Dilute Solution (III). The Influence of the Mixed Solvents)

  • 원영무
    • 대한화학회지
    • /
    • 제17권3호
    • /
    • pp.207-212
    • /
    • 1973
  • 毛細灌法을 利用하여 여러가지 混合溶媒系(dioxane-n-butanol, dioxane-sec-butanol, dioxane-ethyleneglycol, dioxane-kerosene)중에서 polyvinylacetate의 희박용액을 機械的으로 切斷하여 그 결과로 얻어진 平均切斷速度定數(k) 및 極限重合度(g)를 moleculare dimension이 동일한 조건하에서 比較검토하였다. 그 결과 k보다는 g의 값이 사용하는 solvent의 종류에 따라 크게 영향을 받음을 알았으며 이에 關하여 考察하였다.

  • PDF

稀搏溶液에서의 Polymer의 機械的 切斷. 混合溶媒의 영향 Ⅱ (Mechanical Degradation of Polymers in Dilute Solution. The Influence of the Mixed Solvents II.)

  • 원영무
    • 대한화학회지
    • /
    • 제16권1호
    • /
    • pp.50-55
    • /
    • 1972
  • The mechanical degradation of $poly(\alpha-methyl$ styrene) in several mixed solvents (chlorobenzene-n-butyl alcohol, chlorobenzene-sec-butyl alcohol, chlorobenzene-Kerosene, chlorobenzene-methylketone) was studied using the capillary flow method. The velocity constant of scission reaction (K) and the limited degree of polymerization (g) were compared at the same value of [${\eta}$], which is considered as the parameter of molecular dimension of polymers in solution. As results, (K) did not change much, even if the species and the volume fraction of poor(non-) solvents changed, while the value of (g) changed according to the species of poor (non-) solvents and the value of [${\eta}$] these results were discussed.

  • PDF

PEM연료전지의 수분전달에 있어서 1차원 해석을 수행한 동적모델에 관한 연구 (Analysis on a Dynamic Model with One Dimension in Water Transportation of PEM Fuel Cell)

  • 아궁박티르;홍부표;유진광;김영복;윤정인;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.118-123
    • /
    • 2012
  • Water balance has a significant impact on the overall fuel cell performance. Maintenance of proper water management should provide an adequate membrane hydration and avoidance of water flooding in the catalyst layer and gas diffusion layer. Considering the important of advanced water management in PEM fuel cell, this study proposes a simple one dimensional water transportation model of PEM fuel cell for use in a dynamic condition. The model has been created by assumption that the output is the water liquid saturation difference. The liquid saturation change is the total difference between the additional water and the removal water on the system. The water addition is obtained from fuel cell reaction and the electro osmotic drag. The water removal is obtained from capillary transport and evaporation process. The result shows that the capillary water transport of low temperature fuel cell is high because the evaporation rate is low.

Polydimethylsiloxane 채널과 indium tin oxide 전극을 이용한 일회용 전기화학적 검출 시스템 (Disposable Microchip-Based Electrochemical Detector Using Polydimethylsiloxane Channel and Indium Tin Oxide Electrode)

  • 이인제;강치중;김용상;김주호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.227-231
    • /
    • 2005
  • We have developed a microsystem with a capillary electrophoresis (CE) and an electrochemical detector (ECD). The microfabricated CE-ECD systems are adequate for a disposable type and the characteristics are optimized for an application to the electrochemical detection. The system was realized with polydimethylsiloxane (PDMS)-glass chip and indium tin oxide electrode. The injection and separation channels (80 um wide$\ast$40 um deep) were produced by moulding a PDMS against a microfabricated master with relatively simple and inexpensive methods. A CE-ECD systems were fabricated on the same substrate with the same fabrication procedure. The surface of PDMS layer and ITO-coated glass layer was treated with UV-Ozone to improve bonding strength and to enhance the effect of electroosmotic flow. For comparing the performance of the ITO electrodes with the gold electrodes, gold electrode microchip was fabricated with the same dimension. The running buffer was prepared by 10 mM 2-(N-morpholino)ethanesulfonic acid (MES) titrated to PH 6.5 using 0.1 N NaOH. We measured olectropherograms for the testing analytes consisted of catechol and dopamine with the different concentrations of 1 mM and 0.1 mM, respectively. The measured current peaks of dopamine and catechol are proportional to their concentrations. For comparing the performance of the ITO electrodes with the gold electrodes, electropherograms was measured for CE-ECD device with gold electrodes under the same conditions. Except for the base current level, the performances including sensitivity, stability, and resolution of CE-ECD microchip with ITO electrode are almost the same compared with gold electrode CE-ECD device. The disposable CE/ECD system showed similar results with the previously reported expensive system in the limit of detection and peak skew. When we are using disposable microchips, it is possible to avoid polishing electrode and reconditioning.

4차원 TRICKS 자기공명혈관조영술과 기존 TOF 자기공명혈관조영술의 비교 및 유용성 (The Value of Comparison with Four Dimension Time Resolved Imaging of Contrast Kinetics(TRICKS) MRA by Time of Flight(TOF) MRA)

  • 배성진;임청환;박병래;신운재;김정삼
    • 한국콘텐츠학회논문지
    • /
    • 제10권3호
    • /
    • pp.215-221
    • /
    • 2010
  • Time Resolved Imaging of Contrast Kinetics 기법을 이용한 4차원 자기공명혈관조영술 (TRICKS-MRA)영상과 기존 TOF-MRA영상을 비교하여 임상적 유용성에 대해 알아보고자 하였다. 총17명 중 뇌혈관 질환이 의심되는 11명과 뇌종양을 의심하는 6명을 대상으로 TOF-MRA와 TRICKS-MRA을 시행한 후 17 대상자 중 11명에서 DSA를 추가적으로 시행하였다. TOF-MRA는 공간해상력보다 시간해상력이 부족하였고, TRICKS-MRA에서는 TOF-MRA보다 공간분해능은 부족한 점이 많지만 영상판독에 큰 영향은 없었고 모든 대상자에서 동맥과 정맥의 구별이 가능하여 시간분해능이 우수한 것을 나타났다. 또한 종양과 혈관과의 관계성 평가에서 TOF-MRA보다 좋은 것으로 나타났다. TRICKS-MRA방법은 시간대별로 동맥, 모세혈관, 정맥기를 신속하면서 쉽게 4차원적으로 영상화가 가능하여 앞으로 임상에서 이용도가 더욱 증가 할 것으로 사료된다.