• Title/Summary/Keyword: Capillary Pipe

Search Result 87, Processing Time 0.026 seconds

Operating Characteristics of a Sintered-Metal Wick/Methanol Loop Heat Pipe Having a Bypass Line (소결금속 윅과 메탄올을 사용하며 바이패스라인이 부착된 루프히트파이프의 작동 특성)

  • Boo, Joon-Hong;Jung, Eui-Guk
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2130-2135
    • /
    • 2007
  • Operating characteristics of a loop heat pipe (LHP) having a bypass line was investigated experimentally. The LHP had a sintered metal wick as a capillary structure and methanol as a working fluid. The sintered metal wick was made of stainless steel of which the average pore size was 5 ${\mu}m$and porosity of 47%. A bypass line of a small diameter was attached between the vapor escape passage and the liquid reservoir. The dimension of the flat evaporator was $50(L){\times}40(W){\times}30(H)$ mm and that of the condenser was $50(L){\times}40(W){\times}11(H)$ mm. Wall and pipe material of the LHP was stainless steel and heating area was 35(W) mm${\times}$35(L) mm. The inner diameters of vapor and liquid transport lines were 4.0 mm and 2.0 mm, and the lengths of the two lines were both 0.5 m. The LHP was tested for three different tilt angles of horizontal, favorite tilt, and adverse tilt. The thermal load range was up to 290 W at the condenser above evaporation position. Furthermore, the effect of a bypass line on the start-up transient as well as steady-state operation was presented and discussed.

  • PDF

Performance of a Heat pipe with Axial Grooves Formed from Corrugated Plate (접힌 板材 로 만든 그루우브 를 갖는 熱파이프 에 관한 硏究)

  • 김태현;김기현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.1
    • /
    • pp.47-55
    • /
    • 1985
  • Heat pipe with axial grooves formed from corrugated plate in the adiabatic section is studied. The axial grooves made of thin corrugated plate decrease considerably the flow resistance in the adiabatic section without increasing the thermal resistance of the heat pipe, resulting in the increase of the capillary limit, especially in the cases of heat pipes that have long adiabatic section. In the theoretical analysis, it is assumed that the liquid flow in each section laminar and fully developed and Darcy's equation can be applied to each section neglecting the end-effects associated with each transitionary region. A heat pipe which consists of axially corrugated rectangular grooves in the adiabatic section and bronze mesh in the evaporator and codenser sections was made and tested. Comparison of the experimental results, using acetone as the working fluid, with the theoretical result shows satisfactory agreement.

An Experimental Study on the Heat Transfer Characteristics of a High-temperature Sodium Heat Pipe Depending on the Thermal Transport Conditions (고온 나트륨 히트파이프에서 열이송 조건에 따른 열전달 특성에 대한 실험 연구)

  • Park, C.M.;Boo, J.H.;Kim, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2340-2345
    • /
    • 2008
  • Cylindrical stainless-steel/sodium heat pipe for a high-temperature application was manufactured and tested for transient and steady-state operations. Two layers of Stainless-steel screen mesh wick was inserted as a capillary structure. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 mm. As thermal transport conditions, the effective transport length, the heat flux, the tilt angle and the operating temperature were varied. The heat was supplied by an electric furnace up to 1 kW and the cooling was performed by forced convection of air. The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and vapor temperature. Typical range of the total thermal resistance was as low as $0.036^{\circ}C/W$ at $175.8\;kW/m^2$ of heat flux and $700^{\circ}C$ of operating temperature.

  • PDF

Development of mLHP by using Various Size of Wick (다양한 크기의 윅(wick)을 이용한 mLHP의 개발)

  • Ha, Jeong-Seok;Choi, Young-Don;Ahn, Deuk-Kuen
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.175-180
    • /
    • 2008
  • This paper is dedicated to the development of cooling devices such as mLHP with Fan-Fin system limited by noise and vibration. As we know, Heat pipe has the limitation of cooling capability to cool down the electronics. It is bounded by capillary and thermal limitation but heat load that it has to deal with is increasing. Especially Today's electronic technology has a tendency to integrate lots of function into the small piece of a processor like Dual core having 35W heat load for mobile and desktop computer respectively. There is an optimum operating condition of temperature, below $70^{\circ}C$, during the maximum heat load, 35W. There is the motivation needed to develop the new type of cooling devices and we can discuss about the new challenge beyond heat pipe.

  • PDF

Study on a Operating Characteristics of Loop Heat Pipe Using a Brass Sintered Metal Wick-Water (황동소결윅-물 LHP의 작동 특성에 관한 연구)

  • Lee, Wook-Hyun;Lee, Ki-Woo;Park, Ki-Ho;Lee, Kye-Jung;Noh, Seung-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1528-1533
    • /
    • 2004
  • In this study, we have manufactured the LHP(Loop Heat Pipe) with sintered metal wick and investigated the working characteristics of LHP experimentally.Water was used as a working fluid and fill charge rate was changed. LHP basically consist of the separated vapor/liquid channels, evaporator having sintered metal wick(effective pore diameter :$16{\sim}19{\mu}m$), and condenser cooled by water. The diameter of vapor/liquid line tube are 3.2mm/6.35mm, respectively. Heat transfer rate and thermal resistance was represented to study the basic characteristics of LHP at each conditions

  • PDF

The Effect of Powder Characteristics on the Permeability of Copper Powder Wicks in Heat Pipe Applications

  • Lin, Yueh-Ju;Hwang, Kuen-Shyang
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.318-319
    • /
    • 2006
  • The thermal dissipation performance of sintered heat pipes is usually determined by the capillarity and permeability of the Cu powder wicks. Since the capillary provided by the Cu powder is usually large enough to draw water from the condenser end to the evaporator end, the permeability has become the controlling factor. In this study, Cu powders with different particle sizes and shapes were loosely sintered, and their permeabilities were compared. The results show that more complicated shapes, finer particle sizes, lower porosities, and rougher pore surfaces give lower permeability and thermal dissipation.

  • PDF

An Experimental Study on the Thermal Performance of a Flat-Ship Heat Pipe with Inner Grooves and Screen Mesh Cover (내부에 그루브와 스크린 메쉬를 갖는 평판 스트립형 히트파이프의 열성능에 대한 실험적 연구)

  • Park Soo Yong;Boo Joon Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.805-813
    • /
    • 2005
  • The thermal performance of a flat-strip heat pipe with inner grooves and the screen mesh cover was investigated experimentally. The heat pipes were made of 2024 aluminum alloy of which the dimensions were 30 (W) $\times$ 4 (T) $\times$ 150 (L) mm. The cross sectional dimensions of inner groove were 0.4$\times$0.9 mm and the space between grooves was 0.6 mm. To enhance the capillary force, foe screen meshes were attached to cover the grooved inner surface. In the grooved heat pipes without screen mesh cover, the maximum thermal load of 180 W (12 W/$cm^2$) was achieved for operating temperature below $130^{\circ}C$ at horizontal position. The heat pipes with screen mesh cover showed the thermal resistances less than one third of those without screen mesh cover, and showed less fluctuation in the thermal resistance values. Furthermore, the thermal performance of the former exhibited less dependence on the tilt angle and the fill charge ratio.

Design and Development of Thermoacoustic Rdfrierator : I. Acoustic Analysis of Resonator and Prediction of Energy Conversion (열음향 냉동기의 설계 및 개발 : I. 내부공간의 음향해석 및 에너지 변환 예측)

  • Park, Chul-Min;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.44-52
    • /
    • 1996
  • Acoustical characteristics of internal pipe structures and a loudspeaker of the thermoacoustic refrigerator are analyzed by using the transfer matrix method. The resonator system is dismantled into verious basic acoustic elements, and then linearized transfer matrices are serially combined with the dynamical system of linearized loudspeaker model, that the total system of thermoacoustic refrigerator can be analyzed in terms of frequency characteristics and acoustic field shape. Additionally, by using equations for energy flow through the capillary stack, the temperature distribution over the stack is numerically estimated. After expressing the acoustic work flow, thermoacoustic flow, and energy loss per unit length in a single capillary duct by using the transverse functional variations, overall energy flow rate and energy balance are obtained for the whole capillary stack. The final expression for energy flow through the stack is numerically evaluated by varying physical parameters obtained from the sound field analysis. After confirming good agreements between predicted and experimental results for the interior sound field of a refrigerator model, the thermoacoustic characteristics of Hofler's apparatus is analyzed by the proposed method and it is observed that the results agree well with Hofler's experimental results.

  • PDF