The capacity credit (CC) is a key metric for mid- to long-term power system capacity planning. The purpose of this study is to estimate the CCs of domestic wind turbines. Based on hourly capacity factor (CF) data during the seven years from 2011 to 2017, the new so-called probabilistic CF scheme is introduced to effectively reflect the variability of CFs on CC estimation. The CCs are then estimated through the CF-based method and the ELCC (Effective Load Carrying Capability) method reflecting the probabilistic CF scheme, and the results are compared. The results show that the CC value 0.019 for domestic wind turbines proposed in the $8^{th}$ Basic Plan for Electricity Supply and Demand corresponds to the CC with a confidence level slightly lower than 95%.
Magazine of the Korean Society of Agricultural Engineers
/
v.39
no.2
/
pp.124-133
/
1997
Pile load test is good for estimating pile bearing capacity, but using this method is limited by time and cost required. Dynamic and static method is more convenient and economical, but confidence of estimated value by dynamic and static method are lower than that of pile load test. After being compared pile bearing capacity data obtained from pile load test with those of other two methods, the results from this study were summarised as follows. For allowable bearing capacity values greater than 175t per pile, bearing capacity acquired from static method was higher than that acquired from pile load test, whereas bearing capacity acquired from pile load test was higher than that acquired from static method for values under 175 per pile. It was that variance of bearing capacity was large when bearing capacity obtained by dynamic method was higher than 250t. Also bearing capacity based on dynamic method was higher than that based on pile load test. Allowable bearing capacity get from dynamic method suggested that carefull precautions are necessary in application for allowable bearing capacity values higher than 2S0ton per pile.
Data hiding is one of protective methods that can authenticate the completeness of digital information and protect intelligent property rights and copyright through secret communications. In this paper, we propose a data hiding method using pixel-value modular operation that has a high capacity while maintaining a good visual quality. The proposed method can embed secret data on the every pixel of a cover image by modular operation. The experiment results demonstrate that the proposed method has a high capacity and good visual quality where the embedding capacity is 91,138 bytes, the PSNR is 47.94dB, and the Q index is 0.968.
By analyzing the adaptive capacity, market formation and policy direction as functional areas of Technological Innovation System (TIS), the article evaluates the progress of renewable energy transition in the Maldives, with the inclusion of ideas from Mauritius and Cabo Verde. On the policy direction in the Maldives, technology roadmaps produced with assistance from International Renewable Energy Agency (IRENA) and Asian Development Bank (ADB) are evaluated. Although there are inducing factors such as the Solar Risk Management Initiative, the progress of energy transition is hindered by the lack of technical capacity and local value chain. The findings indicate the importance of facilitating and establishing industry and knowledge networks, incorporating innovation policies, greater involvement of the local private sector along with international investors, and taking water-energy nexus to achieve complementary targets. The study adds value to knowledge by offering a simplified TIS framework, with a current insight of the energy transition in Small Island Developing States with a focus on the Maldives.
Kim, Mi-Suk;Moon, Yoon-Hee;Lim, Sabina;Kim, Dae-Jin
Journal of Life Science
/
v.7
no.4
/
pp.329-335
/
1997
This study was conducted to investigate the effect of dietary fiber(DF) levels on the meat quality in colored broiler. Colored broiler were fed on containing corn-soy basal diet(DF 5%) and high level(DF 6,7 and 8%) of dietary fiber diets for 7 weeks. Dietary fiber level of diet was make up by adding some alffalfa meal. Colored broiler meats were stored at 3$\circ$ for 24hr after skaughter, and used to analyze physico-chemical properties. Proximate component, pH, shear force value, myofibril fragmentation index, water holding capacity, cooking loss, protein extractability, fatty acid composition, Hunter's L, a value and palatability of cooked meat were not significantly affected by dietary fiber levels, whereas the Hunter's value of meat was significantly affected bty dietary fiber levels for the final period of feeding. Crude protein content, myofibril fragmentation index, water holding capacity, protein extractability and Hunter's b value of breast meat's were higher than thigh meat's, but crude fat content, pH, shear force value, cooking loss, palmitoleic acid, linolenic acid, and Hunter's a value were lower, regardless of dietary fiber level.
In many practical cases, design methods of pile have been used mainly semi empirical bearing capacity equations. It can be done that confirmation of pile bearing capacities through using of dynamic and static tests during constructing or after constructions. If a prediction of layered point pile bearing capacity could be done through simple tests during field investigation, it could be done that more reliable design of pile than a prediction of using semi empirical equations or static formulations. This paper suggests a method to estimated point bearing capacity during in-situ investigation by using the dynamic rod model pile and verifies the point bearing capacity compare with results of static pile load tests. From test results, the unit ultimate point bearing capacities are relatively similar through a dynamic rod model pile tests and static pile load tests. The unit ultimate point bearing capacity by using N value is shown about 50 % value of measured unit ultimate point bearing capacity from field test result and the prediction of the unit ultimate point bearing capacity by using N value is shown very conservative, illogical and uneconomical pile designs.
Kwan Young Chul;Kwon Jeong-Tae;Jeong Ji Hwan;Lee Sang Jae;Kim Dae Hun
International Journal of Air-Conditioning and Refrigeration
/
v.12
no.4
/
pp.184-191
/
2004
In order to improve the performance of a 2 room heat pump with a constant speed compressor, the optimum refrigeration circuit of the heat pump with different cooling and heating capacities is developed by applying capillary tubes. The refrigeration circuit is composed of four parts; a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The performance of the 2 room heat pump are investigated from a rating experiment and a reliability experiment, using the calorimeter. Results of the rating experiment show that the capacity of heat pump is about $93\%$ of the design value. In particular, the capacity of the cooling single operation is about $13\%$ higher than the design value, and the capacity of the heating multi operation is about $5\%$ higher than the design value. From the reliability experi-ment, it is found that the lowest driving voltage of the compressor is about $75\%$ of the rating voltage. Also the compressor is reoperated normally under the flood back and the over load.
Due to large demand for high speed and great capacity for data transfer, WDM, which uses the wavelength division multiplexing technique, is known as alternative way to satisfy those demand for its flexible network operation and management, easy network expansion with existing networks, and enhancement of efficient data transfer rate. For these reasons, a new high capacity WDM optical communication network plan was established. Therefore, the quality of currently deployed optical cables with 81.6 km in length should be assessed to ensure if high capacity WDM system could be implemented on existing optical cables. Two important characteristic parameters, Transfer Loss and PMD (Polarization Mode Dispersion), were measured to evaluate quality of existing optical cable. Transfer Loss was measured at 0.244 dB per kilometer, which is lower than the design standard value at 0.275 dB/km. The measured PMD value gave at 0.030ps/km, and it, therefore, satisfies the value recommended by ITU-T (International Telecommunication Union-T) of 0.5ps/km. In addition, the transfer characteristic for existing 2.5 Gbps and 10 Gbps system were measured and evaluated, and the results showed that error-free transfer is very much feasible. Computer simulation for DWDM system, which is likely be a future backbone network in Korea, to assess the transfer characteristic using the same condition employed for 2.5 Gbps and 10 Gbps was carried out as well. The simulation verified that a stable network operation and reliable service could be provided.
Journal of the Architectural Institute of Korea Structure & Construction
/
v.35
no.3
/
pp.11-18
/
2019
The purpose of this study was to estimate the resistance capacity of a traditional wooden house with shear walls made of wood panel. In order to achieve the purpose of the study, the load - displacement test was carried out and the resistance moment values of the shear walls were proposed. The shear walls were made by placing studs with a nominal dimension of $38mm{\times}89mm$ at intervals of 600 mm, and attaching 12 mm thick plywood with 8-d size pegs at intervals of 150 mm. The type of traditional building wall was classified and showed the moment resistance ability of each wall type. This value is expressed as a proportional value divided by the moment resisting capacity of the standard size shear walls not divided into the divided small frames. Although some frames have proportional values larger than 1.0 even though they have openings, most of them show values smaller than 1.0. Also, even without the openings, it showed a smaller value than 1, such as 0.84 and 0.67.
In this paper, we define the normalized mean square covariance (MIMO) of multiple input multiple output (MIMO) channels and study the relationship between ergodic MIMO channel capacity and the channel NMSV value.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.