Analysis of Capacity Factors and Capacity Credits for Wind Turbines Installed in Korea (국내 풍력발전 설비의 이용률과 용량크레딧 분석)

  • Paik, Chunhyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.4
    • /
    • pp.79-91
    • /
    • 2019
  • The capacity credit (CC) is a key metric for mid- to long-term power system capacity planning. The purpose of this study is to estimate the CCs of domestic wind turbines. Based on hourly capacity factor (CF) data during the seven years from 2011 to 2017, the new so-called probabilistic CF scheme is introduced to effectively reflect the variability of CFs on CC estimation. The CCs are then estimated through the CF-based method and the ELCC (Effective Load Carrying Capability) method reflecting the probabilistic CF scheme, and the results are compared. The results show that the CC value 0.019 for domestic wind turbines proposed in the $8^{th}$ Basic Plan for Electricity Supply and Demand corresponds to the CC with a confidence level slightly lower than 95%.

A Comparative Study on Bearing Capacity of Single Pile Based on Calculation Method (산정방법에 따른 단말뚝의 지지력 비교연구)

  • 이영대;심재현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.2
    • /
    • pp.124-133
    • /
    • 1997
  • Pile load test is good for estimating pile bearing capacity, but using this method is limited by time and cost required. Dynamic and static method is more convenient and economical, but confidence of estimated value by dynamic and static method are lower than that of pile load test. After being compared pile bearing capacity data obtained from pile load test with those of other two methods, the results from this study were summarised as follows. For allowable bearing capacity values greater than 175t per pile, bearing capacity acquired from static method was higher than that acquired from pile load test, whereas bearing capacity acquired from pile load test was higher than that acquired from static method for values under 175 per pile. It was that variance of bearing capacity was large when bearing capacity obtained by dynamic method was higher than 250t. Also bearing capacity based on dynamic method was higher than that based on pile load test. Allowable bearing capacity get from dynamic method suggested that carefull precautions are necessary in application for allowable bearing capacity values higher than 2S0ton per pile.

  • PDF

Data Hiding Using Pixel-Value Modular Operation (픽셀값 모듈러 연산을 이용한 자료은닉 기법)

  • Byun, Jin-Yong;Kim, Pyung-Han;Lee, Joon-Ho;Jung, Ki-Hyun;Yoo, Kee-Young
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.4
    • /
    • pp.483-491
    • /
    • 2015
  • Data hiding is one of protective methods that can authenticate the completeness of digital information and protect intelligent property rights and copyright through secret communications. In this paper, we propose a data hiding method using pixel-value modular operation that has a high capacity while maintaining a good visual quality. The proposed method can embed secret data on the every pixel of a cover image by modular operation. The experiment results demonstrate that the proposed method has a high capacity and good visual quality where the embedding capacity is 91,138 bytes, the PSNR is 47.94dB, and the Q index is 0.968.

Technological Innovation System for Energy Transition in Small Island Developing States: Adaptive Capacity, Market Formation and Policy Direction in the Maldives

  • Mohamed, Shumais
    • Asian Journal of Innovation and Policy
    • /
    • v.11 no.3
    • /
    • pp.293-319
    • /
    • 2022
  • By analyzing the adaptive capacity, market formation and policy direction as functional areas of Technological Innovation System (TIS), the article evaluates the progress of renewable energy transition in the Maldives, with the inclusion of ideas from Mauritius and Cabo Verde. On the policy direction in the Maldives, technology roadmaps produced with assistance from International Renewable Energy Agency (IRENA) and Asian Development Bank (ADB) are evaluated. Although there are inducing factors such as the Solar Risk Management Initiative, the progress of energy transition is hindered by the lack of technical capacity and local value chain. The findings indicate the importance of facilitating and establishing industry and knowledge networks, incorporating innovation policies, greater involvement of the local private sector along with international investors, and taking water-energy nexus to achieve complementary targets. The study adds value to knowledge by offering a simplified TIS framework, with a current insight of the energy transition in Small Island Developing States with a focus on the Maldives.

Effect of Dietary Fiber Level on Meat Quality in Colored Broiler (식이섬유 수준이 유색육용계의 육질에 미치는 영향)

  • Kim, Mi-Suk;Moon, Yoon-Hee;Lim, Sabina;Kim, Dae-Jin
    • Journal of Life Science
    • /
    • v.7 no.4
    • /
    • pp.329-335
    • /
    • 1997
  • This study was conducted to investigate the effect of dietary fiber(DF) levels on the meat quality in colored broiler. Colored broiler were fed on containing corn-soy basal diet(DF 5%) and high level(DF 6,7 and 8%) of dietary fiber diets for 7 weeks. Dietary fiber level of diet was make up by adding some alffalfa meal. Colored broiler meats were stored at 3$\circ$ for 24hr after skaughter, and used to analyze physico-chemical properties. Proximate component, pH, shear force value, myofibril fragmentation index, water holding capacity, cooking loss, protein extractability, fatty acid composition, Hunter's L, a value and palatability of cooked meat were not significantly affected by dietary fiber levels, whereas the Hunter's value of meat was significantly affected bty dietary fiber levels for the final period of feeding. Crude protein content, myofibril fragmentation index, water holding capacity, protein extractability and Hunter's b value of breast meat's were higher than thigh meat's, but crude fat content, pH, shear force value, cooking loss, palmitoleic acid, linolenic acid, and Hunter's a value were lower, regardless of dietary fiber level.

  • PDF

Evaluation of Point Bearing Capacity using Field Model Pile Test (현장 축소모형 말뚝 시험을 이용한 선단지지력 예측)

  • Lee, Chang-Ho;Lee, Woo-Jin;Jeong, Hun-Jun;Han, Shin-In
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.3
    • /
    • pp.47-54
    • /
    • 2005
  • In many practical cases, design methods of pile have been used mainly semi empirical bearing capacity equations. It can be done that confirmation of pile bearing capacities through using of dynamic and static tests during constructing or after constructions. If a prediction of layered point pile bearing capacity could be done through simple tests during field investigation, it could be done that more reliable design of pile than a prediction of using semi empirical equations or static formulations. This paper suggests a method to estimated point bearing capacity during in-situ investigation by using the dynamic rod model pile and verifies the point bearing capacity compare with results of static pile load tests. From test results, the unit ultimate point bearing capacities are relatively similar through a dynamic rod model pile tests and static pile load tests. The unit ultimate point bearing capacity by using N value is shown about 50 % value of measured unit ultimate point bearing capacity from field test result and the prediction of the unit ultimate point bearing capacity by using N value is shown very conservative, illogical and uneconomical pile designs.

  • PDF

Performance of a 2 Room Multi-Heat Pump with a Constant Speed Compressor

  • Kwan Young Chul;Kwon Jeong-Tae;Jeong Ji Hwan;Lee Sang Jae;Kim Dae Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.184-191
    • /
    • 2004
  • In order to improve the performance of a 2 room heat pump with a constant speed compressor, the optimum refrigeration circuit of the heat pump with different cooling and heating capacities is developed by applying capillary tubes. The refrigeration circuit is composed of four parts; a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The performance of the 2 room heat pump are investigated from a rating experiment and a reliability experiment, using the calorimeter. Results of the rating experiment show that the capacity of heat pump is about $93\%$ of the design value. In particular, the capacity of the cooling single operation is about $13\%$ higher than the design value, and the capacity of the heating multi operation is about $5\%$ higher than the design value. From the reliability experi-ment, it is found that the lowest driving voltage of the compressor is about $75\%$ of the rating voltage. Also the compressor is reoperated normally under the flood back and the over load.

Characteristic Measurement for Ready-Deployed Optical Cable and Simulation for SDH and WDM System Existing Conditions (기포설된 광케이블 특성측정과 이 선로조건에 대한 SDH 및 DWDM 광전송장치 전송특성측정과 시뮬레이션)

  • 이성원;김영범
    • Journal of Applied Reliability
    • /
    • v.1 no.2
    • /
    • pp.121-138
    • /
    • 2001
  • Due to large demand for high speed and great capacity for data transfer, WDM, which uses the wavelength division multiplexing technique, is known as alternative way to satisfy those demand for its flexible network operation and management, easy network expansion with existing networks, and enhancement of efficient data transfer rate. For these reasons, a new high capacity WDM optical communication network plan was established. Therefore, the quality of currently deployed optical cables with 81.6 km in length should be assessed to ensure if high capacity WDM system could be implemented on existing optical cables. Two important characteristic parameters, Transfer Loss and PMD (Polarization Mode Dispersion), were measured to evaluate quality of existing optical cable. Transfer Loss was measured at 0.244 dB per kilometer, which is lower than the design standard value at 0.275 dB/km. The measured PMD value gave at 0.030ps/km, and it, therefore, satisfies the value recommended by ITU-T (International Telecommunication Union-T) of 0.5ps/km. In addition, the transfer characteristic for existing 2.5 Gbps and 10 Gbps system were measured and evaluated, and the results showed that error-free transfer is very much feasible. Computer simulation for DWDM system, which is likely be a future backbone network in Korea, to assess the transfer characteristic using the same condition employed for 2.5 Gbps and 10 Gbps was carried out as well. The simulation verified that a stable network operation and reliable service could be provided.

  • PDF

Shear Resistance Capacity Length of Traditional Wooden Frame's Wall divided into Small Frame (세부목골조로 구성된 전통목골조 벽체 전단저항능력)

  • Hwang, Jong-Kook;Kwon, Yang-Hee;Bae, Dong-Hun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.3
    • /
    • pp.11-18
    • /
    • 2019
  • The purpose of this study was to estimate the resistance capacity of a traditional wooden house with shear walls made of wood panel. In order to achieve the purpose of the study, the load - displacement test was carried out and the resistance moment values of the shear walls were proposed. The shear walls were made by placing studs with a nominal dimension of $38mm{\times}89mm$ at intervals of 600 mm, and attaching 12 mm thick plywood with 8-d size pegs at intervals of 150 mm. The type of traditional building wall was classified and showed the moment resistance ability of each wall type. This value is expressed as a proportional value divided by the moment resisting capacity of the standard size shear walls not divided into the divided small frames. Although some frames have proportional values larger than 1.0 even though they have openings, most of them show values smaller than 1.0. Also, even without the openings, it showed a smaller value than 1, such as 0.84 and 0.67.