• Title/Summary/Keyword: Capacity value

Search Result 2,852, Processing Time 0.03 seconds

A study on improvement of fisheries resources management through analysis of fishing capacity of coastal and offshore fisheries (연근해어업의 어획능력 분석을 통한 수산자원관리 개선방안)

  • JUNG, Ki-Won;LEE, Kwang-Nam;LEE, Yoo-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.57 no.4
    • /
    • pp.342-350
    • /
    • 2021
  • Although Korea operates various systems and policies for the management of fisheries resources, it is judged that a more systematic resource management policy is needed due to the continuous decrease in the production of coastal and offshore fisheries. In this study, the catch capacity was analyzed using the DEA technique for coastal and offshore fisheries. As a result, despite the decrease in the amount of fisheries resources and the number of fishing vessels, there was a trend of increasing fishing capacity. As of 2019, the total maximum catch of offshore fishery was estimated at 820,007 tons. The actual catch was 548,159 tons and the CU was measured to be about 66.8%, which was analyzed to be an excess of about 33.2% of the catch. The total maximum catch of coastal fisheries was estimated at 187,887 tons. The actual catch was also the same value and the CU was measured to be about 100.0%. Thus, it was analyzed that there was no excess in catch. For the management of fisheries resources, it is necessary to manage the fishing capacity. To this end, policies such as scientific TAC should be promoted as well as expanding the reduction of fishing vessels.

Comparison between Sperm Acrosome Reaction following Ionophore Challenge and Sperm Penetration Assay as Assessment of fertilizing Capacity of Human Spermatozoa (인간 정자의 생식력 평가에 있어 첨제반응율과 햄스터 난자 침투 분석법의 비교연구)

  • Moon, Shin-Yong;Ryu, Buom-Yong;Oh, Sun-Kyung;Suh, Chang-Suk;Kim, Seok-Hyun;Choi, Young-Min;Shin, Chang-Jae;Kim, Jung-Gu;Chang, Yoon-Seok;Lee, Jin-Yong
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.22 no.2
    • /
    • pp.131-141
    • /
    • 1995
  • This study was designed to determine the relationship between sperm acrosome reaction following ionophore challenge(ARIC) and hamster ovum sperm penetration assay(SPA) as assessment of fertilizing capacity of male. ARIC test and SPA were performed in 23 fertile and 19 subfertile men. The results were as follows; Sperm concentration was significantly higher in fertile group compared with subfertile group: $114.6{\pm}64.40$ vs $61.3{\pm}46.50{\times}10^6/ml$. However, there were no significantly differences in seminal volume, motility and motility index, respectively. There was a significantly correlation between spontaneous and induced AR in fertile and subfertile group, respectively. ARIC value was significantly higher in fertile group, compared with subfertile group: $12.0{\pm}5.57%$ vs $2.6{\pm}4.96%$. Both Penetration rate(PR) and Penetration index(PI) were significantly higher in fertile group, compared with subfertile group: $97.4{\pm}7.40%$ vs $64.9{\pm}36$. 20% and $5.4{\pm}2.88$ vs $1.5{\pm}1.47$, respectively. The Positive predictive value(PPV), Negative predictive value(NPV), sensitivity and specificity of ARIC test (cut-off: 8.5) and SPA(PI cut-off : 3.0) in predicting fertility were 95.0%, 81.8%, 82.6%, 94.7% and 95.2%, 85.7%, 87.0% and 94.7%, respectively. There was no significantly difference in predicting fertility between ARIC test and SPA. In conclusion, ARIC test was shown to have a predictive value for fertilizing capacity comparable to that of the hamster ovum sperm penetration assay. Therefore, ARIC test may be a simple and cost-effective addition to existing semenology instead of SPA.

  • PDF

Development of a Torrefaction Unit for Food and Agricultural Wastes (음식물·농업폐기물 열분해장치 개발)

  • Song, Dae-Bin;Lim, Ki-Hyeon;Jung, Dae-Hong
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.73-79
    • /
    • 2018
  • In this study, a torrefaction unit with a capacity of 50 kg/hr was developed and experimented to produce of solid fuel by reuse of the food and agricultural wastes. Dried food wastes and agricultural wastes were used for the experiments and the heated-air torrefaction characteristics were investigated by the raw materials, torrefaction air temperature, and torrefaction time. For the dried agricultural wastes, measured torrefaction capacity and lower heating values were 55.35 kg/hr and 3,333 kcal/kg, respectively. As the lower heating values of the treated samples were greater, by around 7.8%, than those of the non-treated samples, torrefaction process was a very effective method to increase the heating value of the agricultural waste. In case of the dried food waste, torrefaction capacity and lower heating value was measured 88.27 kg/hr and 4,016 kcal/kg, respectively. As the lower heating value of treated ones showed around 9.0% higher than that of non treated ones, torrefaction process is very effective method to increase the heating value of the agricultural waste also. It will be assumed that the heating value shows more higher as increase the air temperature and decrease the moisture content of torrified matter.

Physicochemical Characteristics and Antioxidant Capacity in Yogurt Fortified with Red Ginseng Extract

  • Jung, Jieun;Paik, Hyun-Dong;Yoon, Hyun Joo;Jang, Hye Ji;Jeewanthi, Renda Kankanamge Chaturika;Jee, Hee-Sook;Li, Xiang;Lee, Na-Kyoung;Lee, Si-Kyung
    • Food Science of Animal Resources
    • /
    • v.36 no.3
    • /
    • pp.412-420
    • /
    • 2016
  • The objective of this study was to investigate characteristics and functionality of yogurt applied red ginseng extract. Yogurts added with red ginseng extract (0.5, 1, 1.5, and 2%) were produced using Lactobacillus acidophilus and Streptococcus thermophilus and stored at refrigerated temperature. During fermentation, pH was decreased whereas titratable aicidity and viable cell counts of L. acidophilus and S. thermophilus were increased. The composition of yogurt samples was measured on day 1, an increase of red ginseng extract content in yogurt resulted in an increase in lactose, protein, total solids, and ash content, whereas fat and moisture content decreased. The pH value and cell counts of L. acidophilus and S. thermophilus were declined, however titratable acidity was increased during storage period. The antioxidant capacity was measured as diverse methods. During refrigerated storage time, the value of antioxidant effect was decreased, however, yogurt fortified with red ginseng extract had higher capacity than plain yogurt. The antioxidant effect was improved in proportion to concentration of red ginseng extract. These data suggests that red ginseng extract could affect to reduce fermentation time of yogurt and enhance antioxidant capacity.

Study on the Social Carrying Capacity in the Mega-Event - The Case of the International Kwangju Biennale, Korea - (공간 집약적 관광지에서 사회적 수용력 연구)

  • 김진선;정성태
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.31 no.2
    • /
    • pp.28-35
    • /
    • 2003
  • This study was conducted to identify the characteristics of social carrying capacity at mega-events, especially the 2000 Kwangju Biennale in Korea. In particular, this paper has proposed some management policies for mega events taking into account the relations between social carrying capacity, satisfaction and crowding. The research method was to look into the general characteristics and distributive forms of the location, and then to confirm the possibility of sampling the factors involved in satisfaction degree; last, A factor analysis for causal analysis of perceived crowding was performed. The study needed correlation analysis in order to compare expected crowding and perceived crowding, and performed regression to examine the causality of perceived crowding and satisfaction. The research results were as follows: the correlation of expected crowding, perceived crowding, and the total satisfaction was very low or meaningless. The relation between satisfaction and elements for factor analysis such as convenient facilities and value experience showed partial meaningfulness. The factors of convenient facilities, entrance fee, parking lot use, toilet convenience, and exhibit room use had meaningful results; on the other hand, the factors of value experience showed a meaningful result in the guide service of an event place. In conclusion when those holding an event make a basic project, they should consider management measures for convenience of facilities, proper education for guide service, and systematic guidance. Also, as a method for perceived crowding lower than expected crowding, the study has proposed that it is possible to lower expected crowding by providing appropriate information on the number of tourists expected on the weekends and weekdays. Future research should control variables such as personal characteristics, seasons proper for vacation and holidays, and carefully consider their investigation and design. Moreover, it is necessary to study variables involved in expected crowding of more various space-intensive sightseeing places (mesa-events).

Calculation of Thermal Conductivity and Heat Capacity from Physical Data for Some Representative Soils of Korea

  • Aydin, Mehmet;Jung, Yeong-Sang;Lee, Hyun-Il;Kim, Kyung-Dae;Yang, Jae-E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • The thermal properties including volumetric heat capacity, thermal conductivity, thermal diffusivity, and diurnal and annual damping depths of 10 representative soil series of Korea were calculated using some measurable soil parameters based on the Taxonomical Classification of Korean Soils. The heat capacity of soils demonstrated a linear function of water content and ranged from 0.2 to $0.8cal\;cm^{-3}^{\circ}C^{-1}$ for dry and saturated medium-textured soil, respectively. A small increase in water content of the dry soils caused a sharp increase in thermal conductivity. Upon further increases in water content, the conductivity increased ever more gradually and reached to a maximum value at saturation. The transition from low to high thermal conductivity occurred at low water content in the soils with coarse texture, and at high water content in the other textures. Thermal conductivity ranged between $0.37{\times}10^{-3}cal\;cm^{-1}s^{-1}^{\circ}C^{-1}$ for dry (medium-textured) soil and $4.01{\times}10^{-3}cal\;cm^{-1}s^{-1}^{\circ}C^{-1}$ for saturated (medium/coarse-textured) soil. The thermal diffusivity initially increased rapidly with small increases in water content of the soils, and then decreased upon further increases in the soil-water content. Even in an extreme soil with the highest diffusivity value ($1.1{\times}10^{-2}cm^2s^{-1}$), the daily temperature variation did not penetrate below 70 cm soil depth and the yearly variation not below 13.4 m as four times of damping depths.

Seismic behavior of composite walls with encased steel truss

  • Wu, Yun-tian;Kang, Dao-yang;Su, Yi-ting;Yang, Yeong-bin
    • Steel and Composite Structures
    • /
    • v.22 no.2
    • /
    • pp.449-472
    • /
    • 2016
  • This paper studies the seismic behavior of reinforced concrete (RC) walls with encased cold-formed and thin-walled (CFTW) steel truss, which can be used as an alternative to the conventional RC walls or steel reinforced concrete (SRC) composite walls for high-rise buildings in high seismic regions. Seven one-fourth scaled RC wall specimens with encased CFTW steel truss were designed, manufactured and tested to failure under reversed cyclic lateral load and constant axial load. The test parameters were the axial load ratio, configuration and volumetric steel ratio of encased web brace. The behaviors of the test specimens, including damage formation, failure mode, hysteretic curves, stiffness degradation, ductility and energy dissipation, were examined. Test results indicate that the encased web braces can effectively improve the ductility and energy dissipation capacity of RC walls. The steel angles are more suitable to be used as the web brace than the latticed batten plates in enhancing the ductility and energy dissipation. Higher axial load ratio is beneficial to lateral load capacity, but can result in reduced ductility and energy dissipation capacity. A volumetric ratio about 0.25% of encased web brace is believed cost-effective in ensuring satisfactory seismic performance of RC walls. The axial load ratio should not exceed the maximum level, about 0.20 for the nominal value or about 0.50 for the design value. Numerical analyses were performed to predict the backbone curves of the specimens and calculation formula from the Chinese Code for Design of Composite Structures was used to predict the maximum lateral load capacity. The comparison shows good agreement between the test and predicted results.

Transmit Antenna Selection for Dual Polarized Channel Using Singular Value Decision

  • Lee Sang-yub;Mun Cheol;Yook Jong-gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.9A
    • /
    • pp.788-794
    • /
    • 2005
  • In this paper, we focus on the potential of dual polarized antennas in mobile system. thus, this paper designs exact dual polarized channel with Spatial Channel Model (SCM) and investigates the performance for certain environment. Using proposed the channel model; we know estimates of the channel capacity as a function of cross polarization discrimination (XPD) and spatial fading correlation. It is important that the MIMO channel matrix consists of Kronecker product dividable spatial and polarized channel. Through the channel characteristics, we propose an algorithm for the adaptation of transmit antenna configuration to time varying propagation environments. The optimal active transmit antenna subset is determined with equal power allocated to the active transmit antennas, assuming no feedback information on types of the selected antennas. We first consider a heuristic decision strategy in which the optimal active transmit antenna subset and its system capacity are determined such that the transmission data rate is maximized among all possible types. This paper then proposes singular values decision procedure consisting of Kronecker product with spatial and polarize channel. This method of singular value decision, which the first channel environments is determined using singular values of spatial channel part which is made of environment parameters and distance between antennas. level of correlation. Then we will select antenna which have various polarization type. After spatial channel structure is decided, we contact polarization types which have considerable cases It is note that the proposed algorithms and analysis of dual polarized channel using SCM (Spatial Channel Model) optimize channel capacity and reduce the number of transmit antenna selection compare to heuristic method which has considerable 100 cases.

Assessment of Criteria for selecting Rainwater Management Strategies (도시 물순환 건전화를 위한 빗물관리 계획요소 평가)

  • Lee, Tae-Goo;Han, Young-Hae
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.9-17
    • /
    • 2010
  • The purpose of this study is to draw out objective bases for selecting various applicable facilities in case of the establishment of rainwater management strategies. To do so, sixteen facilities were selected from decentralized rainwater management systems that induce rainwater infiltration and detention as well as centralized end-of-pipe type infiltration and detention facilities in local areas. With these facilities, it attempted to evaluate them in terms of sustainability, pollutant elimination, flood control capacity and costs and subsequently analyzed correlations between each characteristic. The outcomes of the analysis were as follows: First was the analysis of characteristics between decentralized rainwater management systems and end-of-pipe rainwater management systems. From the decentralized rainwater management systems, the mulden-rigolen system and grass swale at street level had the highest in the total of the four items while the totals of the underground detention tank and temporary detention site were highest in end-of-pipe rainwater management systems. After analyzing the correlation between different types of facilities and each variable, it can be said that decentralized rainwater management systems have a higher correlation than end-of-pipe rainwater management systems in terms of sustainability whereas the latter are better in flood control capacity than the former. Second, the analysis of correlation in variables of each facility is as follows: first, there is a negative correlation between sustainability value and flood control capacity value; and there is a positive correlation between flood control capability and pollutants elimination. In addition, it revealed that the higher the flood control and pollutant elimination capability the higher the facility costs. Based on these assessments, it is possible to use them as objective selection criteria for facility application in case of site development project or complex plan.

Synthesis of Multifunctional AN-co-(MMA/IA) Fibrous ion-exchanger by Hydrolysis and Adsorption Properties for Trace Transition Elements (가수분해에 의한 AN-co-(MMA(IA) 다관능성 섬유이온교환체의 합성 및 미랑 전이금속 흡착특성)

  • 황택성;이선아;황계순
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.765-773
    • /
    • 2001
  • In In order to remove harmful trace elements such as $Co^{2+}$, $Ni^{2+}$ , $Cr_2O_7\;^{2-}$ from water, we synthesized AN-co-(MMA/IA) according to various mole ratio of monomers and spun by wet-spinning. And multi-functional PAN ion exchangers were prepared by hydrolysis. We observed structure, degree of functionalization, ion exchange capacity, distribution coefficient and mechanical properties for ion exchanger. Anion exchange capacity decreased in 4.5 ~ 4.2 meq/g with increasing of IA content and cation exchange capacity increased in 1.8 ~ 2.2 meq/g. Tensile strength of the ion exchanger increased up to 0.008 mol% IA content and appeared maximum value by 216$kg/cm^2$Distribution coefficient for AN-co-(MMA/IA) ion exchanger appeared maximum value for Co(II), Ni(II) in pH 5-6 range and for Cr(III) in pH 3-4 range. And the adsorption capacity was in the order of Cr(III) > Co(II) > Ni(II) for multicomponent in continuous process.

  • PDF