• Title/Summary/Keyword: Capacity value

Search Result 2,852, Processing Time 0.026 seconds

An Experimental Study on the Flexural Strength and Ductility Capacity of Reinforced High Performance Concrete Beams (고성능 철근콘크리트 보의 휨강도 및 연성능력에 관한 실험적 연구)

  • 김용부;고만영;김상우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.501-506
    • /
    • 1998
  • This paper is an experimental study on the flexural strength and ductility capacity of reinforced high performance concrete beams with the concrete which has compressive strength of 600~700kg/$\textrm{cm}^2$, slump value of 20~25cm and slump-flow value of 60~70cm. Total 8 beams with different tensile reinforcement ratio and pattern of loading were tested. Form the results of reinforced high performance concrete beams, the equivalent stress block parameters proposed by MacGregor et al. or New Zealand code are recommended to use. Also, an extreme fiber concrete compressive strain of reinforced high performance concrete beams are distributed 0.0033~0.0048. In reinforced high performance concrete beams, reinforcement ratio in order to insure curvature ductility index 2 and 4 propose by ACI code should be less than those of reinforced normal strength concrete beams.

  • PDF

Fracture Behavior of CIP Anchor in Cracked Concrete (균열 콘크리트 면에서의 CIP앵커의 파괴거동)

  • 김호섭;윤영수;윤영수;박성균
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.169-174
    • /
    • 2001
  • This study concerns crack effect on concrete anchor system and prediction of tensile capacity, as governed by concrete cone failure, of single anchors located at center of concrete specimen. To Investigate crack effect three different types of crack such as crack width of 0.2mm and 0.5nm, crack depth of loom and 20cm, and crack location of center and biased point were simulated. The static tensile load was subjected to 7/8 in. CIP anchor embedded in concrete of strength 280kg/$cm^{2}$. Tested pullout capacity was compared to prediction value by each current design method (such as ACI 349-97, ACI 349 revision and CEB-FIP which is based on CC Method), In these comparison CC Method and ACI revision showed almost same value in uncracked concrete specimen, however in cracked concrete CC Method showed conservativeness. Therefore the design by ACI 349 revision is recommended for the safe and economic design.

  • PDF

A Model for Determining the Minimum Number of High Speed Exits and Their Locations for Airports (고속탈출유도로 최소 갯수 및 위치 결정 모형)

  • 김병종
    • Journal of Korean Society of Transportation
    • /
    • v.13 no.3
    • /
    • pp.53-65
    • /
    • 1995
  • Proposed are model and its solution algorithm for determining the minimum number of high speed exits and their locations. While the previous researches on exit location aimed to minimize the average runway occuancy time (ROT) of an aircraft mix, the proposed approach is to find the minimum number of exits required to meet maximum allowable ROT. The rationale behind the approach is that the capacity of a runway increases as the ROT decreases down to some value, but not any more even though the ROT keep decreasing below the value. Hence, a maximum allowable ROT might be set up without declining the capacity. The problem is transformed into a shortest path problem on a specially constructed network and Dijkstra's labeling algorithms is employed to solve the problem A hypothetical example is provided to illustrate how the algorithms solves the problem.

  • PDF

Design of High Capacity Rectifier by Parallel Driving of MOSFET (MOSFET 병렬 구동을 이용한 대용량 정류기 구현)

  • Sun, Duk-Han;Cho, Nae-Su;Kim, Woo-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.4
    • /
    • pp.227-233
    • /
    • 2007
  • In case of design of a rectifier to supply high current, To select switching frequency of semiconductor switches affect absolutely the design of the LC filter value in an power conversion circuit. The conventional rectifier by using MOSFET is no use in high current equipments because of small drain-source current. To solve this problem, this paper proposes to design of high capacity rectifier by parallel driving of MOSFET in the single half bridge DC-DC converter. This method can be able to develop high current rectifier by distributed drain-source current. The proposed scheme is able to expect a decrease in size, weight and cost of production by decreasing the LC filter value and increasing maximumly the switching frequency. The validity of the proposed parallel driving strategy is verified through computer-aided simulations and experimental results.

  • PDF

The Effect of Treadmill Training with Elastic Bands on the Chest Expansion and Pulmonary Functions of Young Adults

  • Lim, Sang-Wan;Seo, Kyo-Chul
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.2 no.2
    • /
    • pp.301-307
    • /
    • 2011
  • The purpose of this study was an determine whether elastic band on treadmill training might effect the chest expansion and pulmonary function of the 20's men. 40 subjects with experimental group(male: 20) and control group(male: 20) was participated in experiment. During four weeks, each group participated thirty minutes for three times per week. Subjects were assessed using pre-value and post-value measurement chest length(chest length for resting, chest expansion) and pulmonary function(forced vital capacity, forced expiratory volume at one second, FEV1/FVC, peak expiratory flow, vital capacity, tidal volume, expiratory reserve volume, inspiratory reserve volume) by the CardioTouch 3000S(BIONET, USA). These findings suggest that experimental group can be used to improve chest expansion, pulmonary function than control group. In comparison of both groups, post-test was more improved in experimental group. In conclusion, experimental group helped improving function of pulmonary volume and respiratory muscle, and thus it indicates that the functions will be more improved through the continued respiratory exercise program.

Fabrication of Joining of 37 Multi-filamentary BSCCO(2223) Tape (37심 BSCCO(2223) 다심 초전도선재의 접합공정 연구)

  • 김정호;오승진;김규태;김호진;주진호;나완수
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.3-5
    • /
    • 2001
  • We evaluated the electrical properties of 37 multifilamentary jointed tapes processed by superconducting joint. In the superconducting joining method. a lap-joint was used. Tapes were selectively etched and exposed superconducting cores of the two tapes were brought into contact with each other and then only the joined region was uniaxially pressed in the range of 1,000 to 2,500 MPa. The current carrying capacity and n-value of the jointed tape were evaluated as a function of uniaxial pressure. The highest current carrying capacity and n-value were obtained to be 58%, 26% for the jointed tape to the tape itself.

  • PDF

An Experimental Study on the Small Capacity EHD Power Generation (소용량 EHD 발전에 관한 실험적 연구)

  • Jhoun, C.S.;Lee, J.B.;Lim, E.C.
    • Solar Energy
    • /
    • v.9 no.2
    • /
    • pp.58-68
    • /
    • 1989
  • This paper describes an experimental study that was performed to determine the limiting factors on the power output in the closed cycle Electro-Hydro-Dynamic generator of small capacity. A corona discharge for producing unipolar charged particles used as the charging method. The experiment demonstrated that the corona method of charging was an efficient and effective means of producing unipolar charged particles. Four factors having an effect on the power output characteristics of EHD generator are discussed and examined experimentally, using methyl alcohol and kerosene as working fluides; a. The conversion length between attractor and collector. b. The corona current of Emitter. c. The flow velocity of working fluids. d. Load resistance. This results are as follows; 1) There in a critical value in conversion length for its maximum power output. 2) Power output increases almost linearly with corona current and flow velocity. 3) There is the critical value of load resistance producing a maximum power output. 4) Kerosene is known better working fluid than Methyl alcohol in this EHD generator.

  • PDF

Mathematical representation to assess the wind resource by three parameter Weibull distribution

  • Sukkiramathi, K.;Rajkumar, R.;Seshaiah, C.V.
    • Wind and Structures
    • /
    • v.31 no.5
    • /
    • pp.419-430
    • /
    • 2020
  • Weibull distribution is a conspicuous distribution known for its accuracy and its usage for wind energy analysis. The two and three parameter Weibull distributions are adopted in this study to fit wind speed data. The daily mean wind speed data of Ennore, Tamil Nadu, India has been used to validate the procedure. The parameters are estimated using maximum likelihood method, least square method and moment method. Four statistical tests namely Root mean square error, R2 test, Kolmogorov-Smirnov test and Anderson-Darling test are employed to inspect the fitness of Weibull probability density functions. The value of shape factor, scale factor, wind speed and wind power are determined at a height of 100m using extrapolation of numerical equations. Also, the value of capacity factor is calculated mathematically. This study provides a way to evaluate feasible locations for wind energy assessment, which can be used at any windy site throughout the world.

An analysis of snow melting process for a study of defrosting phenomena (제상 현상 연구를 위한 눈 융해 과정 해석)

  • Lee, K.S;Ko, Y.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.38-47
    • /
    • 1999
  • An improved one-dimensional modeling of snow melting was obtained by considering both the effect of heat capacity and the decreasing influence of porosity. Using the improved model, the effects of initial snow temperature, initial snow density and the heat flux on the snow melting were investigated. It is found that the drainage starting time is delayed and the drainage rate becomes smaller with lower initial snow temperature. ResuIts also show that the drainage starts at the same time when an initial snow density is over a certain value. Melting efficiency increases linearly with an increasing initial snow temperature. With increasing the initial density of the snow and the amount of heat supplied, the melting efficiency increases, then converges to a constant value.

  • PDF

An Improvement for Determining Response Modification Factor in Bridge Load Rating (응력보정계수 산정 방법 개선)

  • Koo, Bong-Kuen;Shin, Jae-In;Lee, Sang-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.1
    • /
    • pp.169-175
    • /
    • 2001
  • Bridge load rating calculations provide a basis for determining the safe load capacity of bridge. Load rating requires engineering judgement in determining a rating value that is applicable to maintaining the safe use of the bridge and arriving at posting and permit decisions. Load testing is an effective means in calculating the rating value of bridge. In Korea, load carrying capacity of bridge is modified by response modification factor that is determined from comparisons of measured values and analysis results. The response modification factor may be corrupted by vehicle location error that is defined as the gap of test vehicle location between load testing and analysis. In this study, the effects of vehicle location error to structural response and response modification factor are investigated, and a new method for evaluating response modification factor is proposed. The random data analysis shows that the proposed method is less sensitive to vehicle location error than the present method.

  • PDF