• 제목/요약/키워드: Capacity of heat exchanger

검색결과 286건 처리시간 0.022초

1 kW급 LNG 스털링 엔진 연소실 수치해석 (CFD STUDY ON THE COMBUSTION CHAMBER OF A 1 kW CLASS STIRLING ENGINE)

  • 안준;이윤식;김혁주
    • 한국전산유체공학회지
    • /
    • 제16권3호
    • /
    • pp.88-94
    • /
    • 2011
  • The availability of the thermal energy has been deeply recognized recently to encourage the cascade usage of thermal energy from combustion. Within the framework, a 1 kW class Stirling engine based cogeneration system has been proposed for a unit of a distributed energy system. The capacity has been designed to be adequate for the domestic usage, which requires high compactness as well as low emission and noise. To develop a highly efficient system with satisfying these requirements, a premixed slot type short flame burner has been proposed and a series of numerical simulation has been performed to establish a design tool for the combustion chamber. The thermal radiation model has been found to highly affect the computational results and a proper resolution to analyze the heat transfer characteristics of the high temperature heat exchanger. Finally, the combustion characteristics of the premixed flame with the metal fiber type burner has been studied.

태양열 이용 비프레온계 $CF_3CH_2F$(R-134a)적용 열펌프시스템에 의한 학교교실 난방에 관한 연구(II) (The performance of solar heat pump with non-freon refrigerant $CF_3CH_2F$(R-134a) for school classroom heating[II])

  • 선경호;정현채;김기선
    • 태양에너지
    • /
    • 제17권1호
    • /
    • pp.3-15
    • /
    • 1997
  • 본 연구는 R-12($CF_2Cl_2F$) 대체냉매인 R-134a($CF_3CH_2F$) 적용 태양열 열펌프시스템에 의하여 학교교실($20{\sim}25$평형)이나 학교 화장실($13{\sim}17$평형)의 난방에 관한 것으로서 대체냉매 적용할 때 시스템의 안정성과 성능에 관해 실험되어졌다. 학교교실 난방을 위한 방법 중에서 온풍난방을 택하여 실험하였는데 대체냉매 적용 실제와 모형시스템의 난방성능을 비교 해석하였다. 이 결과를 근거로 R-22($CHClF_2$)와 그 대체냉매들에 대한 성능을 예측하였다. 서울지방 봄 가을철, 겨울철의 외기 온도에서 실내온도가 $18{\sim}20^{\circ}C,\;23{\sim}25^{\circ}C$로 유지할 수 있도록 설계 제작되었다.

  • PDF

사이클 해석을 통한 GHP 성능 예측 (Prediction of GHP Performance Using Cycle Analysis)

  • 차우호;최송;정백영;김병순;전시문
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권1호
    • /
    • pp.15-21
    • /
    • 2015
  • 가스 엔진 히트 펌프는 가스 엔진의 축동력으로 압축기를 구동하는 시스템으로 전력을 거의 사용하지 않고, 엔진 폐열을 활용하기 때문에 하절기와 동절기에 전력 Peak 를 억제하는 공조기로 주목을 받고 있는 제품이다. 제품 개발 시 시스템 성능 예측이 중요하므로 이를 위해 초기 설정한 운전점에서 열교환기 및 압축기의 특성을 반영하여 반복 계산을 수행하면 최종적인 운전점을 도출할 수 있고, 가스 엔진의 성능 데이터를 활용하면 가스 엔진 히트 펌프의 정확한 효율을 예측할 수 있다. 난방 성능을 예측할 때에는 엔진 폐열이 시스템에 공급되기 때문에 외부 열을 흡입하는 구간과 엔진 폐열을 흡입하는 구간을 동시에 고려해야 예측의 정확도를 높일 수 있다. 25 마력 가스 엔진 히트 펌프의 성능을 예측한 값은 실제 측정한 값과 비교하였을 경우 5% 정도의 오차가 발생하며 향후 성능 예측 모델을 구성되는 부품 특성을 반영하면 오차의 폭이 감소될 것으로 예상된다.

광센서를 이용한 제상제어 방법에 대한 타당성 검토 (Feasibility Study on a Defrost Control Method by Using a Photoelectric Sensors)

  • 전창덕;김동선;이승준
    • 한국산학기술학회논문지
    • /
    • 제15권6호
    • /
    • pp.3389-3395
    • /
    • 2014
  • 제상제어 수단으로 사용하고 있는 일정 시간 제어방식, 온도차 제어방식 등은 종종 제상 오작동과 에너지 낭비를 가져오므로 좀 더 정확하게 제상을 제어할 수 있는 방법이 요구되고 있다. 수광부와 발광부로 구성된 광센서를 실외 열교환기 전방에 설치하여 서리의 유무에 따른 출력전압의 변화를 관찰함으로서 정확하게 제상제어를 할 수 있다. 본 연구에서는 기존의 일정시간 제상 방법을 사용하는 경우 나타나는 시스템 성능 및 특성 곡선을 광센서를 사용하여 재현가능한지 판단하기 위해 KS C 9306에 따른 난방 제상능력 시험조건(건구온도 $2^{\circ}C$/습구온도 $1^{\circ}C$)에서 실험을 수행하였다. 실험을 통해 측정한 난방능력, 소비전력, 열교환기 표면온도와 광센서 수광부 출력전압을 비교, 분석한 결과 제상 제어수단으로 광센서의 사용가능성을 확인하였다. 일정시간 제상방법을 통해 구한 제상 제어 단속 주기는 광센서를 통해 측정한 출력 전압의 단속 주기와 잘 일치하였다.

50 MPa급 대용량 수소압축기 사이클 해석 (Hydrogen Compressor Cycle Analysis for the Operating Pressure of 50 MPa and High Charging Capacity)

  • 송병희;명노석;장선준;권정태
    • 한국산학기술학회논문지
    • /
    • 제21권2호
    • /
    • pp.66-73
    • /
    • 2020
  • 현재 개발되고 있는 수소 압축 사이클에서는 압축기를 통해 초고압으로 압축된 수소를 고압용기 내에 저장하여 사용한다. 이러한 충전과정 중 용기내의 수소의 압력 및 온도 상승으로 인하여 고압용기에서 열응력이 발생할 수 있다. 고압용기의 신뢰성을 확보하기 위해서는 용기내의 수소의 온도를 예측하고 제어하는 것이 중요하다. 본 논문에서는 이러한 고압용기의 신뢰성 해석을 위하여 50 MPa급 수소압축시스템에서 고압용기를 충전하는 과정에서의 압력상승에 따른 용기 내의 수소온도 변화 및 외부와의 열평형까지 걸리는 시간, 감압밸브를 지날 때의 수소온도 변화, 고압용기 냉각을 위한 열교환기의 요구능력 등에 대하여 이론적인 방법과 수치적인 방법으로 해석을 수행하였다. 이론해석 결과, 고압용기의 내부 온도는 충전하기 전에 40 ℃에서 충전 후 1st cycle, 2nd cycle에서 평균적으로 126.675 ℃, 62.1 ℃가 증가하였다. 또한, 고압용기의 충전량은 1st cycle, 2nd cycle에서 각각 7.9 kg, 8.9 kg으로 계산되었다. 본 연구의 결과는 수소충전소와 같이 수소압축시스템이 필요한 현장의 인프라 설계 및 구축 등에 유용하게 활용 될 것이다.

Design Considerations on the Standby Cooling System for the integrity of the CNS-IPA

  • Choi, Jungwoon;Kim, Young-ki
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.104-104
    • /
    • 2015
  • Due to the demand of the cold neutron flux in the neutron science and beam utilization technology, the cold neutron source (CNS) has been constructed and operating in the nuclear research reactor all over the world. The majority of the heat load removal scheme in the CNS is two-phase thermosiphon using the liquid hydrogen as a moderator. The CNS moderates thermal neutrons through a cryogenic moderator, liquid hydrogen, into cold neutrons with the generation of the nuclear heat load. The liquid hydrogen in a moderator cell is evaporated for the removal of the generated heat load from the neutron moderation and flows upward into a heat exchanger, where the hydrogen gas is liquefied by the cryogenic helium gas supplied from a helium refrigeration system. The liquefied hydrogen flows down to the moderator cell. To keep the required liquid hydrogen stable in the moderator cell, the CNS consists of an in-pool assembly (IPA) connected with the hydrogen system to handle the required hydrogen gas, the vacuum system to create the thermal insulation, and the helium refrigeration system to provide the cooling capacity. If one of systems is running out of order, the operating research reactor shall be tripped because the integrity of the CNS-IPA is not secured under the full power operation of the reactor. To prevent unscheduled reactor shutdown during a long time because the research reactor has been operating with the multi-purposes, the introduction of the standby cooling system (STS) can be a solution. In this presentation, the design considerations are considered how to design the STS satisfied with the following objectives: (a) to keep the moderator cell less than 350 K during the full power operation of the reactor under loss of the vacuum, loss of the cooling power, loss of common electrical power, or loss of instrument air cases; (b) to circulate smoothly helium gas in the STS circulation loop; (c) to re-start-up the reactor within 1 hour after its trip to avoid the Xenon build-up because more than certain concentration of Xenon makes that the reactor cannot start-up again; (d) to minimize the possibility of the hydrogen-oxygen reaction in the hydrogen boundary.

  • PDF

암반 대수층에서 개방형 지열 시스템의 개발 및 적용 (Development of a Groundwater Source Heat Pump in a Fractured Rock Aquifer)

  • 심병완;김성균;최한나;이수형;하규철;김용철
    • 신재생에너지
    • /
    • 제17권3호
    • /
    • pp.32-41
    • /
    • 2021
  • A groundwater source heat pump (GWHP) was developed in this study by adapting a borehole heat exchanger with closed-loop and open-loop systems in a new building. In the pilot test building, the air-conditioning on the second floor was designed to employ a closed-loop system and that on the third floor had an open-loop system. The GWHP design is based on the feasibility of groundwater resources at the installation site. For the hydrogeological survey of the study site, pumping and injection tests were conducted, and the feasibility of GWHP installation was evaluated based on the air-conditioning load demand of the building. The site was found to be satisfactory for the design capacity of the thermal load and water quality. In addition, the effect of groundwater movement on the performance of the closed-loop system was tested under three different operational scenarios of groundwater pumping. The performance of the system was sustainable with groundwater flow but declined without appropriate groundwater flow. From long-term observations of the operation, the aquifer temperature change was less than 2℃ at the observation well and 5℃ at the injection well with respect to the initial groundwater temperature. This pilot study is expected to be of guidance for developing GWHPs at fractured rock aquifers.

흡열연료를 이용한 고속비행체 냉각기술 동향 (A Technical Review of Endothermic Fuel Use on High Speed Flight Cooling)

  • 김중연;박선희;전병희;김성현;정병훈;한정식
    • 한국추진공학회지
    • /
    • 제14권2호
    • /
    • pp.71-79
    • /
    • 2010
  • 극초음속 비행체의 속도증가와 엔진효율의 향상으로 비행체와 엔진의 열적부하가 증가하게 되었다. 극초음속 영역에서 공기흐름의 온도는 매우 높기 때문에 공냉방식을 이용한 냉각이 불가능하므로, 비행체 연료를 주 냉각제로써 이용하는 것은 필수적이다. 흡열연료(Endothermic fuels)는 열분해 또는 촉매분해와 같은 흡열반응(Endothermic reaction)을 통해 열을 흡수하는 액체 탄화수소 비행체 연료이다. 흡열반응은 촉매를 이용하여 전환율과 생성물 분포를 변화시킴으로써 개선될 수 있다. 고온의 액체 탄화수소는 코킹 생성을 유발하여 열교환기의 효율을 저하시키고 촉매 비활성을 촉진시킬 수 있기 때문에, 흡열연료의 흡열능력은 코킹생성(Coke formation)이 발생하기 전까지의 온도로 제한한다. 본 연구 에서는 흡열연료를 적용한 주요 냉각기술동향과 흡열연료의 특성이 기술되었다.

상업용 대형 가스오븐 시스템의 최적 설계 (Optimization Design of Commercial Large Gas Oven Systems)

  • 김도현;유병훈;금성민;이창언
    • 에너지공학
    • /
    • 제25권2호
    • /
    • pp.21-28
    • /
    • 2016
  • 본 연구는 국내 상업용 대형 가스오븐 시스템 개발을 목표로 연소기의 연소조건에 대한 수치해석 및 실험을 통해 적정 당량비를 결정한 후 공급열량(20,000 kcal)에 적합한 열교환기를 설계하고 대류 팬 제어방법을 검토하여 상업용 대형 가스오븐 시스템 설계 및 최적운전조건을 도출하는 것이다. 실험결과 당량비는 0.82가 가장 적절하였고 오븐 내부 중앙지점의 온도가 $200^{\circ}C$까지 도달하는데 걸리는 시간은 대류 팬의 회전방향이 반시계방향일 때 시계방향 보다 단축되었다. 또한 오븐 내부의 온도를 균일하게 유지하기 위해서는 대류 팬 제동장치가 필요하였다. 오븐 내부의 승온구간과 온도유지구간 동안 배출되는 배기가스의 열량을 통해 시스템 효율을 비교한 결과 전열면적이 큰 열교환기를 설치한 시스템의 효율이 높게 나타났다.

벤치급 CO2 포집공정에서 흡수반응기의 내부구조에 따른 K-계열 고체흡수제의 성능평가 (Performance Evaluation of K-based Solid Sorbents Depending on the Internal Structure of the Carbonator in the Bench-scale CO2 Capture Process)

  • 김재영;임호;우제민;조성호;문종호;이승용;이효진;이창근;이종섭;민병무;박영철
    • Korean Chemical Engineering Research
    • /
    • 제55권3호
    • /
    • pp.419-425
    • /
    • 2017
  • 본 연구에서는 벤치급 건식 $CO_2$ 포집 성능평가 장치에서 흡수반응기 내부의 구조와 형태에 따른 K-계열 흡수제(KEP-CO2P2, 한국전력공사 전력연구원)의 성능특성을 확인하였다. 흡수반응기 혼합영역(mixing-zone)에 구조와 형태가 다르게 제작된 두 종류의 열교환기가 적용되었으며, 각각 CASE 1과 CASE 2로 나뉘어 동일한 조업조건으로 연속운전을 수행하였다. 연속운전동안 흡수반응 온도는 $75{\sim}80^{\circ}C$, 재생반응 온도는 $190{\sim}200^{\circ}C$, 그리고 반응기체($CO_2$) 농도는 12~14 vol%으로 설정하였다. 특히 흡수제의 흡수능 비교를 위해 흡수반응기 혼합영역의 차압을 400~500 mm$H_2O$로 유지하며 운전하였다. 또한 반응 후 채집한 시료는 반응성 비교를 위해 TGA를 이용하여 물성분석을 하였다. CASE 1 실험에서 $CO_2$ 제거효율과 동적흡수능은 각각 64.3%, 2.40 wt%으로 산출 되었고, CASE 2 실험에서 $CO_2$ 제거효율과 동적흡수능은 각각 81.0%, 4.66 wt%으로 산출되었다. 또한 반응 후 흡수제에 대한 TGA 측정 결과의 무게감량을 이용하여 흡수제의 동적흡수능을 계산한 결과, CASE 1과 CASE 2 실험에서 반응 후 흡수제의 동적흡수능은 각각 2.51 wt%와 4.89 wt%으로 산출되었다. 결론적으로 동일한 조업조건에서 흡수반응기 내부에 삽입되는 열교환기의 구조와 형태에 따라 흡수제의 성능 차이가 있는 것을 확인하였다.